Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Comparitive Study of High-Order Positivity-Preserving WENO Schemes

In gas dynamics and magnetohydrodynamics flows, physically, the density ρ and the pressure p should both be positive. In a standard conservative numerical scheme, however, the computed internal energy is The ideas of Zhang & Shu (2012) and Hu et al. (2012) precisely address the aforementioned issue. Zhang & Shu constructed a new conservative positivity-preserving procedure to preserve positive density and pressure for high-order Weighted Essentially Non-Oscillatory (WENO) schemes by the Lax-Friedrichs flux (WENO/LLF). In general, WENO/LLF is obtained by subtracting the kinetic energy from the total energy, resulting in a computed p that may be negative. Examples are problems in which the dominant energy is kinetic. Negative ρ may often emerge in computing blast waves. In such situations the computed eigenvalues of the Jacobian will become imaginary. Consequently, the initial value problem for the linearized system will be ill posed. This explains why failure of preserving positivity of density or pressure may cause blow-ups of the numerical algorithm. The adhoc methods in numerical strategy which modify the computed negative density and/or the computed negative pressure to be positive are neither a conservative cure nor a stable solution. Conservative positivity-preserving schemes are more appropriate for such flow problems. too dissipative for flows such as turbulence with strong shocks computed in direct numerical simulations (DNS) and large eddy simulations (LES). The new conservative positivity-preserving procedure proposed in Hu et al. (2012) can be used with any high-order shock-capturing scheme, including high-order WENO schemes using the Roe's flux (WENO/Roe). The goal of this study is to compare the results obtained by non-positivity-preserving methods with the recently developed positivity-preserving schemes for representative test cases. In particular the more di cult 3D Noh and Sedov problems are considered. These test cases are chosen because of the negative pressure/density most often exhibited by standard high-order shock-capturing schemes. The simulation of a hypersonic nonequilibrium viscous shock tube that is related to the NASA Electric Arc Shock Tube (EAST) is also included. EAST is a high-temperature and high Mach number viscous nonequilibrium ow consisting of 13 species. In addition, as most common shock-capturing schemes have been developed for problems without source terms, when applied to problems with nonlinear and/or sti source terms these methods can result in spurious solutions, even when solving a conservative system of equations with a conservative scheme. This kind of behavior can be observed even for a scalar case as well as for the case consisting of two species and one reaction.. This EAST example indicated that standard high-order shock-capturing methods exhibit instability of density/pressure in addition to grid-dependent discontinuity locations with insufficient grid points. The evaluation of these test cases is based on the stability of the numerical schemes together with the accuracy of the obtained solutions.

Schemes↗

Preliminary Results on Setup Precision of Prone-Lateral Patient Positioning for Whole Breast Irradiation

Purpose: The aim of this study was to develop a rapid and reproducible technique for prone positioning and to compare dose-volume indices in prone and supine positions. Methods and Materials: Eighteen patients underwent computed tomography imaging for radiotherapy planning in prone and supine position. Experience was gained in the first eight patients, which lead to modifications of the Horizon prone breast board (Civco Medical Solutions, Orange City, Iowa, USA) and the patient setup technique. A unilateral breast holder (U-BH) was developed (Van de Velde, Schellebelle, Belgium) to retract the contralateral breast away from the treated breast. The technique was then applied to an additional 10 patients. The setup precision was evaluated using daily cone-beam CT. Results: Modifications to the breast board were made to secure a prone-lateral rather then a pure prone position. We evolved from a classical setup using laser marks on the patients' body to a direct breast setup using marks on the breast only. The setup precision of the direct positioning procedure with the modified breast board and the U-BH is comparable to supine setup data in the literature. Dose-volume indices for heart and lung show significantly better results for prone than for supine position, and dose homogeneity within the treated breast did not differ according to the treatment position. Conclusions: The setup precision of our prone-lateral positioning technique is comparable to supine data in literature. Our data show the advantage of prone radiotherapy to spare the lung and heart. Further research is necessary to reduce the duration of prone setup.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Positional Reproducibility of Pancreatic Tumors Under End-Exhalation Breath-Hold Conditions Using a Visual Feedback Technique

Purpose: To assess positional reproducibility of pancreatic tumors under end-exhalation (EE) breath-hold (BH) conditions with a visual feedback technique based on computed tomography (CT) images. Methods and Materials: Ten patients with pancreatic cancer were enrolled in an institutional review board-approved trial. All patients were placed in a supine position on an individualized vacuum pillow with both arms raised. At the time of CT scan, they held their breath at EE with the aid of video goggles displaying their abdominal displacement. Each three-consecutive helical CT data set was acquired four times (sessions 1-4; session 1 corresponded to the time of CT simulation). The point of interest within or in proximity to a gross tumor volume was defined based on certain structural features. The positional variations in point of interest and margin size required to cover positional variations were assessed. Results: The means {+-} standard deviations (SDs) of intrafraction positional variations were 0.0 {+-} 1.1, 0.1 {+-} 1.2, and 0.1 {+-} 1.0 mm in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions, respectively (p = 0.726). The means {+-} SDs of interfraction positional variations were 0.3 {+-} 2.0, 0.8 {+-} 1.8, and 0.3 {+-} 1.8 mm in the LR, AP, and SI directions, respectively (p = 0.533). Population-based margin sizes required to cover 95th percentiles of the overall positional variations were 4.7, 5.3, and 4.9 mm in the LR, AP, and SI directions, respectively. Conclusions: A margin size of 5 mm was needed to cover the 95th percentiles of the overall positional variations under EE-BH conditions, using this noninvasive approach to motion management for pancreatic tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On-Board Imaging Validation of Optically Guided Stereotactic Radiosurgery Positioning System for Conventionally Fractionated Radiotherapy for Paranasal Sinus and Skull Base Cancer

Purpose: To evaluate the positioning accuracy of an optical positioning system for stereotactic radiosurgery in a pilot experience of optically guided, conventionally fractionated, radiotherapy for paranasal sinus and skull base tumors. Methods and Materials: Before each daily radiotherapy session, the positioning of 28 patients was set up using an optical positioning system. After this initial setup, the patients underwent standard on-board imaging that included daily orthogonal kilovoltage images and weekly cone beam computed tomography scans. Daily translational shifts were made after comparing the on-board images with the treatment planning computed tomography scans. These daily translational shifts represented the daily positional error in the optical tracking system and were recorded during the treatment course. For 13 patients treated with smaller fields, a three-degree of freedom (3DOF) head positioner was used for more accurate setup. Results: The mean positional error for the optically guided system in patients with and without the 3DOF head positioner was 1.4 {+-} 1.1 mm and 3.9 {+-} 1.6 mm, respectively (p <.0001). The mean positional error drifted 0.11 mm/wk upward during the treatment course for patients using the 3DOF head positioner (p = .057). No positional drift was observed in the patients without the 3DOF head positioner. Conclusion: Our initial clinical experience with optically guided head-and-neck fractionated radiotherapy was promising and demonstrated clinical feasibility. The optically guided setup was especially useful when used in conjunction with the 3DOF head positioner and when it was recalibrated to the shifts using the weekly portal images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reducing patient posture variability using the predicted couch position

A method is presented in which the couch position is predicted before the treatment instead of obtaining a reference position at the first treatment fraction. This prevents systematic differences in patient posture between preparation and treatment. In literature, only limited data are available on couch positioning. We position our patients at the planned couch position, allowing a small difference between skin marks and lasers, followed by online imaging. For a 3-month period, our standard deviations (mm) in couch position in the vertical, longitudinal, and lateral directions were head and neck—1.6, 2.8, and 2.5; thorax—2.9, 5.5, and 4.5; breast—3.0, 4.1, and 4.0; and pelvis—3.5, 4.0, and 4.7, respectively. We have improved the reproducibility of patient posture in our institute by using the predicted couch position. Our data may serve as a reference for other institutes because the couch position variation is less than that published in literature.

61 RADIATION PROTECTION AND DOSIMETRY↗

High event rate analysis technique for the dual-axis duo-lateral position-sensitive silicon detectors of FAUST

The dual-axis duo-lateral (DADL) position-sensitive silicon detector was developed to obtain precise position and energy information for detected charged particles. The Forward Array Using Silicon Technology (FAUST) is currently equipped with 68 DADL detectors backed by CsI(Tl) scintillators for the study of charged particle correlations in heavy-ion collisions where precise position and energy information is essential. When conventional signal processing electronics were used for the DADL detectors, a position dependence of the measured energy as well as distortions in the calculated particle positions were observed. In previous work, waveforms from the detector after preamplification were studied to better understand the features that give rise to these distortions; therein, a waveform analysis technique was developed to improve the energy resolution and linearity in position reconstruction. However, the reading and writing of waveforms for an entire detector array limits data collection rates and adds significant burden in data storage and analysis speed. In this work, the integrators of a Struck SIS3316 ADC were utilized to process 228 Th source data to develop and optimize a new analysis method that captures the benefits of the waveform analysis technique while circumventing the waveform writing requirement. This integrator method – capable of 59 keV (FWHM) energy resolution – was used in the collection of 35 MeV/nucleon 28 Si + 12 C collision data using FAUST to investigate exotic decays of highly excited highly deformed nuclei. In this data, a position resolution of 0.4 mm (FWHM) was obtained for 25 MeV α-particles; for α-particles near this energy that originate from 8 Be ground state decays, a 8 Be ground state width of 30 keV (FWHM) was obtained. The impact of the energy-dependent DADL position resolution emergent from electronic noise on the quality of excited state measurement was modeled and compared to the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kepler Certified False Positive Table

This document describes the Kepler Certied False Positive table hosted at the Exoplanet Archive1, herein referred to as the CFP table. This table is the result of detailed examination by the Kepler False Positive Working Group (FPWG) of declared false positives in the Kepler Object of Interest (KOI) tables (see, for example, Batalha et al. (2012); Burke et al.(2014); Rowe et al. (2015); Mullally et al. (2015); Coughlin et al. (2015b)) at the Exoplanet Archive. A KOI is considered a false positive if it is not due to a planet orbiting the KOI's target star. The CFP table contains all KOIs in the Exoplanet Archive cumulative KOI table. The purpose of the CFP table is to provide a list of certified false positive KOIs. A KOI is certified as a false positive when, in the judgement of the FPWG, there is no plausible planetary interpretation of the observational evidence, which we summarize by saying that the evidence for a false positive is compelling. This certification process involves detailed examination using all available data for each KOI, establishing a high-reliability ground truth set. The CFP table can be used to estimate the reliability of, for example, the KOI tables which are created using only Kepler photometric data, so the disposition of individual KOIs may differ in the KOI and CFP tables. Follow-up observers may find the CFP table useful to avoid observing false positives.

Kepler↗

Impact of Stress-Activated Positive Holes on the Redox Timing in Organisms Living at the Surface of Rocks: Unlocking Nature's Secrets

Stressing and deforming igneous and/or high-grade metamorphic rocks activates electronic charge carriers known as positive holes, h•, that are defect electrons in the O2–sublattice, e.g. O-states. Like h•in semiconductors, the h•in rocks affect electrical and thermal properties. They produce electrochemical reactions, localized electrical signals, and currents. In this study, we explore the effects of positive holes on the electron flow in the electron transport chain (ETC) of organisms living at the surface of rocks such as gabbro or granite. We found that positive holes, h•, disrupt the in vivotemporal coordination governed by oscillating reduction-oxidation reactions, known as the redox cycle. Positive holes affect the timing of the redox cycle by interacting with essentialmolecules in vivo, leading to the formation of hydroxyl radicals and superoxide anions. We observed that positive holes significantly impede the growth of yeast Saccharomyces cerevisiae(i.e., colony size) and delay the sprouting of broccoli seeds. Additionally, positive holes were found to exert discernible impacts on plant development such as stem length and leaf size. Our findings highlight the intricate interplay between positive holes, redox timing, and biological processes, shedding light on the potentially significant role of positive holes in influencing the growth and development of organisms in tectonically stressed crustal environments. Understanding these effects has implications for a broader understanding of redox biology and of how environmental factors can influence cellular development in natural settings.

hypermutation↗

Position-specific carbon isotope analysis of serine by gas chromatography/Orbitrap mass spectrometry, and an application to plant metabolism

Position-specific 13 C/ 12 C ratios within amino acids remain largely unexplored in environmental samples due to methodological limitations. We hypothesized that natural-abundance isotope patterns in serine may serve as a proxy for plant metabolic fluxes including photorespiration. Here we describe an Orbitrap method optimized for the position-specific carbon isotope analysis of serine to test our hypothesis and discuss the generalizability of this method to other amino acids. Position-specific carbon isotope ratios of serine were measured using a Thermo Scientific™ Q Exactive™ GC Orbitrap™. Amino acids were hydrolyzed from Arabidopsis biomass, purified from potential matrix interferences, and derivatized alongside standards. Derivatized serine (N,O-bis(trifluoroacetyl)methyl ester) was isolated using gas chromatography, trapped in a reservoir, and purged into the electron ionization source over tens of minutes, producing fragment ions containing different combinations of atoms from the serine-derivative molecule. The 13 C/ 12 C ratios of fragments with monoisotopic masses of 110.0217, 138.0166, and 165.0037 Da were monitored in the mass analyzer and used to calculate position-specific δ 13 C values relative to a working standard. This methodology constrains position-specific δ 13 C values for nanomole amounts of serine isolated from chemically complex mixtures. The δ 13 C values of fragment ions of serine were characterized with ≤1‰ precisions, leading to propagated standard errors of 0.7–5‰ for each carbon position. Position-specific δ 13 C values differed by up to ca 28 ± 5‰ between serine molecules hydrolyzed from plants grown under contrasting pCO 2 , selected to promote different fluxes through photosynthesis and photorespiration. The method was validated using pure serine standards characterized offline. Here this study presents the first Orbitrap-based measurements of natural-abundance, position-specific carbon isotope variation in an amino acid isolated from a biological matrix. We present a method for the precise characterization of isotope ratios in serine and propose applications probing metabolism in plants. We discuss the potential for extending these approaches to other amino acids, paving the way for novel applications.

59 BASIC BIOLOGICAL SCIENCES↗

Recent use of NSAID and NOAC medications are associated with a positive CT arteriogram

Background: Computed tomography angiography (CTA) is a diagnostic modality utilized in patients with suspected active lower gastrointestinal (GI) bleeding. CTA use in clinical practice is limited by the risk of contrast-induced nephropathy, and the loss of patients from direct physician observation while undergoing the test. Identifying clinical predictors of a positive result would be useful in guiding physician utilization of CTA studies. Methods: We performed a single-center retrospective study to determine which clinical predictors are associated with a positive CTA. Binary logistical regression modeling was used to identify the independent predictors and the results were expressed as adjusted odds ratios with corresponding 95% CI . Results: 262 patients met inclusion criteria and there were 61 (23.3%) positive CTA exams. In unadjusted analysis those who were CTA positive were more likely to require management in the intensive care unit (85.2% vs. 14.8%, p < 0.01) and being CTA positive was associated with a significantly increased in-hospital mortality (14.8% vs. 4.5%, p < 0.01). The use of a novel oral anticoagulant (NOAC) in the week prior to presentation was associated with a positive CTA after adjustment for confounders (adjusted odds ratio = 3.89; 95% CI 1.05–14.43). Similarly, the use of a non-steroidal anti-inflammatory drug (NSAID) was associated with a positive CTA (OR 2.36; 1.03–5.41). Only 8% of patients experienced contrast-induced nephropathy. Conclusion: Use of either NOACs or NSAIDs in the previous week is independently associated with a positive CTA in the setting of acute lower GI bleeding. CTA exams appear to confer a low risk of contrast-induced nephropathy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In vivo dynamics of GFRα1-positive spermatogonia stimulated by GDNF signals using a bead transplantation assay

In mouse testes, spermatogonial stem cells (SSCs), a subpopulation of GFRα1 (GDNF family receptor-α1)-positive spermatogonia, are widely distributed along the convoluted seminiferous tubules. The proliferation and differentiation of the SSCs are regulated in part by local expression of GDNF (glial cell-derived neurotorphic factor), one of major niche factors for SSCs. However, the in vivo dynamics of the GDNF-stimulated GFRα1-positive spermatogonia remains unclear. Here, we developed a simple method for transplanting DiI-labeled and GDNF-soaked beads into the mouse testicular interstitium. By using this method, we examined the dynamics of GFRα1-positive spermatogonia in the tubular walls close to the transplanted GDNF-soaked beads. The bead-derived GDNF signals were able to induce the stratified aggregate formation of GFRα1-positive undifferentiated spermatogonia by day 3 post-transplantation. Each aggregate consisted of tightly compacted A{sub single} and marginal A{sub paired}–A{sub aligned} GFRα1-positive spermatogonia and was surrounded by A{sub aligned} GFRα1-negative spermatogonia at more advanced stages. These data not only provide in vivo evidence for the inductive roles of GDNF in forming a rapid aggregation of GFRα1-positive spermatogonia but also indicate the usefulness of this in vivo assay system of various growth factors for the stem/progenitor spermatogonia in mammalian spermatogenesis. - Highlights: • A novel bead transplantation assay was developed to examine the in vivo effects of growth factors on spermatogonia. • A rapid aggregation of GFRα1-positive spermatogonia was induced by the transplanted GDNF-soaked beads. • Tightly-compacted A{sub single} and marginal A{sub paired}–A{sub aligned} spermatogonia were formed in each GFRα1-positive aggregate.

60 APPLIED LIFE SCIENCES↗

A Prospective Study of Intrafraction Prostate Motion in the Prone vs. Supine Position

Purpose: To prospectively analyze prostate intrafraction motion in the prone vs. supine position and to assess patient satisfaction with these two positions. Methods and Materials: Fifteen prostate cancer patients underwent implantation of five fiducial gold seeds in their prostate for localization. Patients were treated with high-dose-rate brachytherapy to 2,200 cGy followed by intensity-modulated radiation therapy (IMRT) to 5,040 cGy. Patients underwent computed tomography simulation and IMRT in the prone position. For the first five IMRT treatments, an electronic portal imaging system was used to acquire anteroposterior (AP) and lateral images pretreatment and posttreatment. We then repositioned each patient supine and repeated the process, resulting in 600 images. Results: Mean +- standard deviation intrafraction prostate motion was 2.1 +- 1.2 mm and 1.7 +- 1.4 mm (AP, p = 0.47), 2.2 +- 2.0 mm and 1.6 +- 1.8 mm (superoinferior, p = 0.16), and 1.0 +- 1.2 mm and 0.6 +- 0.9 mm (left-right, p = 0.03) in the prone and supine positions, respectively. Eighty percent of patients stated that they were more comfortable in the supine position (p = 0.02). Conclusions: Prone and supine positions resulted in a similar magnitude of AP and superoinferior intrafraction prostate motion (2 mm). Because there was no significant difference in the magnitude of AP and superoinferior prostate motion prone vs. supine and patients were more comfortable in the supine position, patients now undergo IMRT to the prostate and seminal vesicles at our center in the supine position.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nonendemic HPV-Positive Nasopharyngeal Carcinoma: Association With Poor Prognosis

Purpose: To investigate the relationship between human papillomavirus (HPV) and Epstein-Barr virus (EBV) in nonendemic nasopharyngeal carcinoma (NPC) and assess the prognostic implications of viral status. Methods and Materials: Paraffin-embedded tumor specimens from 62 patients with primary NPC diagnosed between 1985 and 2011 were analyzed for EBV and high-risk HPV. EBV status was determined by the use of in situ hybridization for EBV encoded RNA. HPV status was assessed with p16 immunohistochemistry and multiplex polymerase chain reaction MassArray for determination of HPV type. Proportional hazards models were used to compare the risk of death among patients as stratified by viral status. Results: Of 61 evaluable tumors, 26 (43%) were EBV-positive/HPV-negative, 18 (30%) were HPV-positive/EBV-negative, and 17 (28%) were EBV/HPV-negative. EBV and HPV infection was mutually exclusive. HPV positivity was significantly correlated with World Health Organization grade 2 tumors, older age, and smoking (all P<.001). The racial distribution of the study population was 74% white, 15% African American, and 11% Asian/Middle Eastern. Among HPV-positive patients, 94% were white. At a median follow-up time of 7 years, HPV-positive and EBV/HPV-negative tumors exhibited worse outcomes than did EBV-positive tumors, including decreased overall survival (hazard ratio [HR] 2.98, P=.01; and HR 3.89, P=.002), progression-free survival (HR 2.55, P=.02; and HR 4.04, P<.001), and locoregional control (HR 4.01, P=.03; and HR 6.87, P=.001). Conclusion: In our Midwestern population, high-risk HPV infection may play an etiologic role in the development of nonendemic, EBV-negative NPC. Compared with EBV-positive NPC, HPV-positive and EBV/HPV-negative NPC are associated with worse outcomes. A larger confirmatory study is needed to validate these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Machine Learning Enabled Position Detection for 6.78 MHz UAV Wireless Power Transfer System

This paper presents a novel supervised machine learning (SML) approach for accurate position detection of the receiver coil in wireless power transfer (WPT) systems using only secondary-side electrical measurements, with applications in autonomous unmanned aerial vehicle (UAV) charging. The proposed method trains a supervised learning model to map measured secondary-side voltage and current features to the receiver’s spatial position with high precision. This enables an autonomous UAV to determine its location relative to the primary coil center, the optimal position for maximizing wireless charging efficiency. The sensing method is fully integrated into a standard WPT system, utilizing the same primary and secondary coils for both power transfer and position detection, thereby eliminating additional sensing hardware. The use of a 6.78 MHz operating frequency enhances positional sensitivity, as high-frequency near-field electromagnetic fields respond strongly to small spatial variations. Experimental validation is performed on a 30 W scaled prototype featuring a 210 mm × 140 mm primary coil, a 50 mm × 80 mm receiver coil, and a 15 mm air gap. Results demonstrate reliable position estimation and a strong correlation between predicted position and optimal coil alignment. This integrated framework unifying position detection and wireless charging offers a promising foundation for future autonomous electric vertical takeoff and landing (eVTOL) systems, enabling compact, hardware-efficient, and high-accuracy charging solutions.

Colak, Kerim [New York University]↗

SU-C-12A-07: Effect of Vertical Position On Dose Reduction Using X-Care

Purpose: Reduction of absorbed dose to radiosensitive tissues is an important goal in diagnostic radiology. Siemens Medical has introduced a technique (X-CARE) to lower CT dose to anterior anatomy by reducing the tube current during 80° of rotation over radiosensitive tissues. Phantom studies have shown 30-40% dose reduction when phantoms are positioned at isocenter. However, for CT face and sinus exams, the center of the head is commonly positioned below isocenter. This work investigated the effects of vertical patient positioning on dose reduction using X-CARE. Methods: A 16cm Computed Tomography Dose Index phantom was scanned on a Siemens Definition Flash CT scanner using a routine head protocol, with the phantom positioned at scanner isocenter. Optically stimulated luminescent dosimeters were placed on the anterior and posterior sides of the phantom. The phantom was lowered in increments of 2cm and rescanned, up to 8cm below isocenter. The experiment was then repeated using the same scan parameters but adding the X-CARE technique. The mean dosimeter counts were determined for each phantom position, and the difference between XCARE and routine scans was plotted as a function of distance from isocenter. Results: With the phantom positioned at isocenter, using XCARE reduced dose to the anterior side of the phantom by 40%, compared to dose when X-CARE was not used. Positioned below isocenter, anterior dose was reduced by only 20-27%. Additionally, using X-CARE at isocenter reduced dose to the anterior portion of the phantom by 45.6% compared to scans performed without X-CARE 8cm below isocenter. Conclusion: While using X-CARE substantially reduced dose to the anterior side of the phantom, this effect was diminished when the phantom was positioned below isocenter, simulating common practice for face and sinus scans. This indicates that centering the head in the gantry will maximize the effect of X-CARE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-88: Mammography Imaging: Does Positioning Matter?

Purpose: In mammography, compression is imperative for quality images and glandular radiation exposure dose. The thickness of the compressed breast directly determines mammography acquisition parameters. The compressed thickness varies due to variation in technologist practice, even for the same patient imaged at different time. This study is to investigate potential effect of the variation in breast positioning on radiation dose and image quality. Methods: Radiation dose at different thicknesses was measured with a BR-12 breast phantom for both conventional craniocaudal view and tomosynthesis in a Hologic Tomosynthesis mammography system. The CIRS stereotactic needle biopsy training phantom embedded dense masses and microcalcification in various sizes were imaged for image quality evaluation. Radiologists evaluated images. Clinical mammograms from the same patient but acquired at different time were retrospectively retrieved to evaluate potential effects of variation in positioning. Results: Acquisition parameters (kVp and mAs) increase with the increased phantom thickness. Radiation exposure increases following an exponential trend. The stereotactic phantom images showed loss of spatial and contrast resolution with inappropriate positioning. The compressed pressure may not be a good indicator for appropriate positioning. The inclusion of different amount of pectoralis muscle may lead to the same compressed pressure but different compressed thickness. The initial retrospective study of 3 patients showed that there were potential large variations in positioning the same patient at different examination time, resulting in large variations in patient radiation dose and image quality. Conclusion: Variations in patient positioning potentially influence patient radiation dose and image quality. The technologist has the critical responsibility to position patient to provide quality images in spite of different breast and body types. To reduce intra and inter practice variations in positioning patient, a training program among each breast imaging center may be a need.

60 APPLIED LIFE SCIENCES↗

SU-E-T-538: Does Abdominal Compression Through Prone Patient Position Reduce Respiratory Motion in Lung Cancer Radiotherapy?

Purpose: This study assesses the effect of physiological abdominal compression from prone positioning by comparing respiratory-induced tumor movements in supine and prone positions. Methods: 19 lung cancer patients underwent repeated supine and prone free-breathing 4DCT scans. The effect of patient position on motion magnitude was investigated for tumors, lymph nodes (9 cases), and subgroups of central (11 cases), peripheral (8 cases) and small peripheral tumors (5 cases), by evaluating the population average excursions, absolute and relative to a carina-point. Results: Absolute motion analysis: In prone, motion increased by ~20% for tumors and ~25% for lymph nodes. Central tumors moved more compared to peripheral tumors in both supine and prone (~22%, and ~4% respectively). Central tumors movement increased by ~12% in prone. For peripheral tumors the increase in prone position was ~25% (~40% and 29% changes on along RL and AP directions). Motion relative to carina-point analysis: Overall, tumor excursions relative to carina-point increased by ~17% in prone. Lymph node relative magnitudes were lower by ~4%. Likewise, the central tumors moved ~7% less in prone. The subgroup of peripheral tumors exhibited increased amplitudes by ~44%; the small peripheral tumors had even larger relative displacements in prone (~46%). Conclusion: Tumor and lymph node movement in the patient population from this study averaged to be higher in prone than in supine position. Results from carina analysis also suggest that peripheral tissues have more physiologic freedom of motility when placed in the prone position, regardless of size. From these observations we should continue to avoid prone positioning for all types of primary lung tumor, suggesting that patients should receive radiotherapy for primary lung cancer in supine position to minimize target tissue mobility during normal respiratory effort. Further investigation will include more patients with peripheral tumors to validate our observations.

60 APPLIED LIFE SCIENCES↗

Results of the long range position-determining system tests

The long range position-determining system (LRPDS) has been developed by the Corps of Engineers to provide the Field Army with a rapid and accurate positioning capability. The LRPDS consists of an airborne reference position set (RPS), up to 30 ground based positioning sets (PS), and a position computing central (PCC). The PCC calculates the position of each PS based on the range change information provided by each Set. The positions can be relayed back to the PS again via RPS. Each PS unit contains a double oven precise crystal oscillator. The RPS contains a Hewlett-Packard cesium beam standard. Frequency drifts and off-sets of the crystal oscillators are taken in account in the data reduction process. A field test program was initiated in November 1972. A total of 54 flights were made which included six flights for equipment testing and 48 flights utilizing the field test data reduction program. The four general types of PS layouts used were: short range; medium range; long range; tactical configuration. The overall RMS radial error of the unknown positions varied from about 2.3 meters for the short range to about 15 meters for the long range. The corresponding elevation RMS errors vary from about 12 meters to 37 meters.

Rhode, F. W.↗