Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Photocatalytic Degradation of the Nanocomposite Film Comprising Polyvinyl Chloride (PVC) and Sonochemically Synthesized Iron-Doped Zinc Oxide: A Comparative Study of Performances Between Sunlight and UV Radiation

Photocatalytic degradation of a composite film made of PVC and Fe-doped ZnO nanoparticles under both UV and sunlight have been accomplished and compared. The metal-doped semiconductor nanoparticles were previously synthesized using ultrasound. The nanoparticles had average crystal size of 33.67 nm and a bandgap of 2.69 eV. Catalysts loading were varied. Composite film with 0.033 g Fe-ZnO per g PVC was found to be the optimum with respect to degradation and mechanical properties. Degradation was monitored by loss in weight. Under sunlight 12% degradation could be achieved with the composite film in 210 min whereas under UV light the degradation was 10%. For pure PVC film, the corresponding degradations were 4.2 and 4.84% respectively. A plausible mechanism has been suggested and validated with experimental results which fitted the proposed model satisfactorily.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

OpenMP and MPI implementations of an elasto-viscoplastic fast Fourier transform-based micromechanical solver for fast crystal plasticity modeling

Here, we explore several parallel implementations of an elasto-viscoplastic fast Fourier transform (EVPFFT) model using Message Passing Interface (MPI), OpenMP, and a hybrid of MPI and OpenMP to efficiently predict micromechanical response of polycrystals. Performance studies using EVPFFT are performed based on domain decomposition over voxels of a periodic cell, which is a representative volume element (RVE) of polycrystalline copper. We begin by parallelizing the computationally intensive Newton–Raphson (NR) single crystal solver within EVPFFT. Next, we compare the performance of the serial and parallel FFTW (Fastest Fourier Transform in the West) using OpenMP (OpenMP-FFTW) and MPI (MPI-FFTW) with the original Numerical Recipes-based FOURN routine within EVPFFT. In the parallel environment, we find that the FFT calculations are best performed using the MPI version of FFTW. Finally, the remainder of the code, except read/write subroutines, is parallelized. Significant speedups of the original EVPFFT model are achieved using MPI on shared memory multicore workstations. Furthermore, results achieved on a distributed memory Cray supercomputer show promising strong and weak scalability and in some cases even super scalability for the single crystal NR solver in EVPFFT. MPI-FFTW also scales perfectly for microstructure RVEs larger than 64 3 FFT voxels. For example, the MPI-EVPFFT parallel version of the code accelerates the simulations for approximately two orders of magnitude using 64 cores over the old serial code for an RVE size of 128 3 . Finally, the parallel EVPFFT code developed in this work can run massive voxel-based microstructural RVEs taking the advantages of thousands of logical cores provided by more advanced clusters.

42 ENGINEERING↗

Study the performance of photogalvanic cells for solar energy conversion and storage: Rose Bengal-D-Xylose-NaLS system

The Rose Bengal is used as photosensitizer with D-Xylose as reductant and sodium lauryl sulphate (NaLS) as surfactant for the enhancement of the conversion efficiency and storage capacity of photogalvanic cell for its commercial viability. The observed value of the photogeneration of photopotential was 885.0 mV and photocurrent was 460.0 {mu}A whereas maximum power of the cell was 407.10 {mu}W. The observed power at power point was 158.72 {mu}W and the conversion efficiency was 1.52%. The fill factor 0.3151 was experimentally determined at the power point of the cell. The rate of initial generation of photocurrent was 63.88 {mu}A min{sup -1}. The photogalvanic cell so developed can work for 145.0 min in dark on irradiation for 165.0 min, i.e. the storage capacity of the photogalvanic cell is 87.87%. A simple mechanism for the photogeneration of photocurrent has also been proposed. (author)

14 SOLAR ENERGY↗

Thermal performance sensitivity studies in support of material modeling for extended storage of used nuclear fuel

The work reported here is an investigation of the sensitivity of component temperatures of a storage system, including fuel cladding temperatures, in response to age-related changes that could degrade the design-basis thermal behavior of the system. The purpose of these sensitivity studies is to provide a realistic example of how changes in the physical properties or configuration of the storage system components can affect temperatures and temperature distributions. The magnitudes of these sensitivities can provide guidance for identifying appropriate modeling assumptions for thermal evaluations extending long term storage out beyond 50, 100, 200, and 300 years.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A very thin havar film vacuum window for heavy ions to perform radiobiology studies at the BNL Tandem

Heavy ion beams from the BNL Tandem Van de Graaff accelerators will be made available for radiobiology studies on cell cultures. Beam energy losses need to be minimized both in the vacuum window and in the air in order to achieve the ranges required for the cells to be studied. This is particularly challenging for ions heavier than iron. The design is presented of a 0.4-inch diameter Havar film window that will satisfy these requirements. Films as thin as 80 microinches were successfully pressure tested. The final thickness to be used may be slightly larger to help in achieving pin hole free windows. We discuss design considerations and present pressure and vacuum test results as well as tests with heavy ion beams.

36 MATERIALS SCIENCE↗

Field Study of Performance, Comfort, and Sizing of Two Variable-Speed Heat Pumps Installed in a Single 2-Story Residence

With the recent advancements in the application of variable-speed (VS) compressors to residential HVAC systems, opportunities are now available to size heat pumps (HPs) to more effectively meet heating and cooling loads in many of the climate zones in the US with limited use of inefficient resistance heat. This is in contrast to sizing guidance for traditional single-speed HPs that limits the ability to oversize with regard to cooling loads, because of risks of poor dehumidification during the cooling season and increased cycling losses. VS-drive HPs can often run at 30-40% of their rated cooling capacity to reduce cycling losses, and can adjust fan speed to provide better indoor humidity control. Detailed air-side performance data was collected on two VS-drive heat pumps installed in a single unoccupied research house in Knoxville, TN, a mixed-humid climate. One system provided space conditioning for the upstairs, while the other unit provided space conditioning for the downstairs. Occupancy was simulated by operating the lights, shower, appliances, other plug loads, etc. to simulate the sensible and latent loads imposed on the building space by internal electric loads and human occupants according to the Building America Research Benchmark (2008). The seasonal efficiency and energy use of the units are calculated. Annual energy use is compared to that of the single speed minimum efficiency HPs tested in the same house previously. Sizing of the units relative to the measured building load and manual J design load calculations is examined. The impact of the unit sizing with regards to indoor comfort is also evaluated.

Munk, Jeffrey D↗

Building America Case Study: High Performance Ducts in Hot-Dry Climates; Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)

?Ducts in conditioned space (DCS) represent a high priority measure for moving the next generation of new homes to the Zero Net Energy performance level. Various strategies exist for incorporating ducts within the conditioned thermal envelope. To support this activity, in 2013 the Pacific Gas & Electric Company initiated a project with Davis Energy Group (lead for the Building America team, Alliance for Residential Building Innovation) to solicit builder involvement in California to participate in field demonstrations of various DCS strategies. Builders were given incentives and design support in exchange for providing site access for construction observation, diagnostic testing, and builder survey feedback. Information from the project was designed to feed into California's 2016 Title 24 process, but also to serve as an initial mechanism to engage builders in more high performance construction strategies. This Building America project complemented information collected in the California project with BEopt simulations of DCS performance in hot/dry climate regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Solutions Case Study: Hygrothermal Performance of a Double-Stud Cellulose Wall

Moisture problems within the building shell can be caused by a number of factors including excess interior moisture that is transported into the wall through air leakage and vapor drive, bulk water intrusion from leaks and wind-driven rain, capillary action from concrete to wood connections, and through wetted building materials such as siding wetted from rain splash back. With the increasing thickness of walls, moisture issues could increase. Several builders have successfully used “double-wall” systems to more practically achieve higher R-values in thicker framed walls. A double wall typically consists of a load-bearing external frame wall constructed with 2 × 4 framing at 16 in. on center using conventional methods. After the building is enclosed, an additional frame wall is constructed several inches inside the load-bearing wall. Several researchers have used moisture modeling software to conduct extensive analysis of these assemblies; however, little field research has been conducted to validate the results. In this project, the Building America research team Consortium for Advanced Residential Buildings monitored a double-stud assembly in climate zone 5A to determine the accu¬racy of moisture modeling and make recommendations to ensure durable and efficient assemblies.

Building America↗

New Whole-House Solutions Case Study: The Performance House: A Cold Climate Challenge Home, Old Greenwich, Connecticut

By working with builder partners on test homes, researchers from the U.S. Department of Energy’s Building America program can vet whole-house building strategies and avoid potential unintended consequences of implementing untested solution packages on a production scale. To support this research, Building America team Consortium for Advanced Residential Buildings (CARB) partnered with Preferred Builders Inc. on a high-performance test home in Old Greenwich, Connecticut. The philosophy and science behind the 2,700 ft2 “Performance House” was based on the premise that homes should be safe, healthy, comfortable, durable, efficient, and adaptable to the needs of homeowners. The technologies and strategies used in the “Performance House” were best practices rather than cutting edge, with a focus on simplicity in construction, maintenance, and operation. Achieving 30% source energy savings compared with a home built to the 2009 International Energy Conservation Code in the cold climate zone requires that nearly all components and systems be optimized. Careful planning and design are critical. The end result was a DOE Challenge Home that achieved a Home Energy Rating System (HERS) Index Score of 20 (43 without photovoltaics [PV]).

accessibility↗