Advanced Supported Liquid Membranes for Carbon Dioxide Control in Cabin Applications

The development of new, robust, life support systems is critical to NASA's continued progress in space exploration. One vital function is maintaining the carbon dioxide (CO2) concentration in the cabin at levels that do not impair the health or performance of the crew. The carbon dioxide removal assembly (CDRA) is the current CO2 control technology on-board the International Space Station (ISS). Although the CDRA has met the needs of the ISS to date, the repeated cycling of the molecular sieve sorbent causes it to break down into small particles that clog filters or generate dust in the cabin. This reduces reliability and increases maintenance requirements. Another approach that has potential advantages over the current system is a membrane that separates CO2 from air. In this approach, cabin air contacts one side of the membrane while other side of the membrane is maintained at low pressure to create a driving force for CO2 transport across the membrane. In this application, the primary power requirement is for the pump that creates the low pressure and then pumps the CO2 to the oxygen recovery system. For such a membrane to be practical, it must have high CO2 permeation rate and excellent selectivity for CO2 over air. Unfortunately, conventional gas separation membranes do not have adequate CO2 permeability and selectivity to meet the needs of this application. However, the required performance could be obtained with a supported liquid membrane (SLM), which consists of a microporous material filled with a liquid that selectively reacts with CO2 over air. In a recently completed Phase II SBIR project, Reaction Systems, Inc. fabricated an SLM that is very close to meeting permeability and selectivity objectives for use in the Portable Life Support System (PLSS). This paper describes work carried out to evaluate its potential for use in the cabin.

Wickham, David T.↗

Sequential Filtering in the Presence of Uniform Measurement Errors

This paper presents a sequential filtering strategy using observations corrupted with uniform measurement noise. While the Kalman filter remains the best linear estimator of the state, other filtering techniques provide minimum variance optimal estimates, a trait only enjoyed by the Kalman filter when the underlying noises are, in fact, Gaussian. This work develops a new approximate optimal estimator for uniform measurement noises. The resulting recursion requires just slightly more computational time to complete a measurement update than the Kalman filter, which generally cannot be claimed by other optimal strategies such as the particle or Gaussian mixture filters.

James S. McCabe↗

Sequential Filtering in the Presence of Uniform Measurement Errors

This paper presents a sequential filtering strategy using observations corrupted with uniform measurement noise. While the Kalman filter remains the best linear estimator of the state, other filtering techniques provide minimum variance optimal estimates, a trait only enjoyed by the Kalman filter when the underlying noises are, in fact, Gaussian. This work develops a new approximate optimal estimator for uniform measurement noises. The resulting recursion requires just slightly more computational time to complete a measurement update than the Kalman filter, which generally cannot be claimed by other optimal strategies such as the particle or Gaussian mixture filters.

James S McCabe↗

Optical filters made from random metasurfaces using Bayesian optimization

Abstract We theoretically investigate the ability to design optical filters from a single material and a single layer of randomly dispersed resonant dielectric particles, defining a random metasurface. Using a Bayesian and generalized Mie inverse-design approach, we design particle radii distributions that give rise to longpass, shortpass, bandpass, and bandstop spectral bands in the infrared. The optical response is shown to be directly related to electric and magnetic multipole scattering of the constituent particles and their near field coupling. We discuss the effect of the particle size distribution and particle–particle coupling interactions on filter design in random systems lacking long-range order.

Materials Science↗

Characterization of Biological Fallout Particles of Cleanrooms to Measure Spacecraft Cleanliness

NASA cleanrooms are humidity, temperature-regulated, and particle contaminant-controlled environments used for spacecraft assembly. Microorganisms, which are crucial contaminants shed from humans and transported through the environment, can adapt to the oligotrophic cleanroom conditions. These biogenic particles need to be identified to extend our knowledge of biological contamination for future NASA mission use. Here, we devised an aluminum coupon with polycarbonate filter setup to collect fallout particles from an ISO 5 and an ISO 7 cleanroom. We demonstrated the presence of microbial particles, as standalone entities and associated with inert particles in cleanroom environments. The contamination was confirmed as biogenic in virtue of estimating the elemental composition of individual and aggregated particles using an epifluorescence and Field Emission Scanning Electron Microscopy (FESEM) coupled with an energy dispersive X-ray analysis (EDX). Epifluorescence microscopy showed that the particles were stained less (25%) with SYTO 9 and more (75%) with propidium iodide, suggesting that the suspected biogenic particles are membrane-compromised. Remarkably, biological particles such as bacteria and fungal spores/hyphae were observed at sizes ranging from 2 to 70 µm, with abundant C and O elemental signatures and essential tracers (Na, Mg, K, Ca and Cl). Inert particles (2 to 500 µm) that were characterized included compositions such as silica (SiO2), aluminosilicates (Al, Si), and carbonaceous fibers. Furthermore, we designed and illustrated a unique correlative epifluorescence and FE-SEM method to strengthen this approach by acquiring the same biogenic particles in the same filter coupon for a one-to-one comparison. Interestingly, the SYTO 9 stained particles showed abundant C and O elemental signature implying that they are viable microbial particles. Constant evaluation of cleanroom biological and inert particles will help to characterize biological contamination for future NASA missions (e.g. Mars 2020).

Malli Mohan, Ganesh Babu↗

Method for concentrating solids and removing solids from a filter medium

Disclosed are methods for concentrating solids and removing solids from a filter medium. The method includes the step of concentrating first particles of a first solid by removing a fluid stream through a filter medium in a filter. At least some of the first particles become blocking particles that block pores of the filter medium. The method also includes the step of inserting second particles of a second solid into the filter. These second particles scrape, vibrate, agglomerate, or a combination thereof along the filter medium, thus dislodging at least a portion of the blocking particles.

Frankman, David↗

Insights From Routine Microbiological Monitoring of Air in Astromaterials Curation Cleanrooms

NASA maintains nine separate cleanrooms at the Johnson Space Center to curate and preserve astromaterials samples. Routine microbial monitoring of the surfaces in these cleanrooms began in 20181. Until recently, materials compatibility requirements prevented monitoring airborne biological particles in all but one of these cleanrooms. New astromaterials collections from carbon rich asteroids are more susceptible to biological degradation than previous collections. Therefore, it is important to monitor the bioburden in the air and on surfaces in these labs. Establishing a comprehensive microbial monitoring program will help inform the monitoring and curation plans for Mars sample return which will include samples that are extremely biologically sensitive. In April of 2022 we began routinely collecting air samples in seven of the nine curation cleanrooms (Meteorite ISO 7 equivalent, Lunar ISO 6 equivalent, Stardust, Hayabusa2, OSIRIS-REx ISO 5 equivalent, and Genesis ISO 4 equivalent) using a sampling device that collects airborne biological particles on an electret filter instead conventional sampler that collect cells in a liquid media or onto organic rich Petri dishes. Electret is a generic term for electrostatically charged media. The charge on these materials increases particle trapping when compared to non-charged filters of similar thickness. N95 respirators also use electret filters. This dry sample collection method allows us to meet materials requirements for all the curation labs and reduces the risk of inadvertently introducing contamination as part of our monitoring effort. This method also allows us to preserve a portion of each sample for DNA extraction and next generation sequencing. DNA sequencing helps us to characterize the portion of the cleanroom microbiome that we cannot culture. We will present the results of our first 8 months of monitoring, compare these results to particle counts in the labs and to measurements made directly onto Petri dishes when possible. We will also make recommendations for modifications to the sampling method to improve sampling efficiency and preserve diversity.

A. B. Regberg↗

Correcting for filter-based aerosol light absorption biases at the Atmospheric Radiation Measurement program's Southern Great Plains site using photoacoustic measurements and machine learning

Abstract. Measurement of light absorption of solar radiation by aerosols is vital for assessing direct aerosol radiative forcing, which affects local and global climate. Low-cost and easy-to-operate filter-based instruments, such as the Particle Soot Absorption Photometer (PSAP), that collect aerosols on a filter and measure light attenuation through the filter are widely used to infer aerosol light absorption. However, filter-based absorption measurements are subject to artifacts that are difficult to quantify. These artifacts are associated with the presence of the filter medium and the complex interactions between the filter fibers and accumulated aerosols. Various correction algorithms have been introduced to correct for the filter-based absorption coefficient measurements toward predicting the particle-phase absorption coefficient (Babs). However, the inability of these algorithms to incorporate into their formulations the complex matrix of influencing parameters such as particle asymmetry parameter, particle size, and particle penetration depth results in prediction of particle-phase absorption coefficients with relatively low accuracy. The analytical forms of corrections also suffer from a lack of universal applicability: different corrections are required for rural and urban sites across the world. In this study, we analyzed and compared 3 months of high-time-resolution ambient aerosol absorption data collected synchronously using a three-wavelength photoacoustic absorption spectrometer (PASS) and PSAP. Both instruments were operated on the same sampling inlet at the Department of Energy's Atmospheric Radiation Measurement program's Southern Great Plains (SGP) user facility in Oklahoma. We implemented the two most commonly used analytical correction algorithms, namely, Virkkula (2010) and the average of Virkkula (2010) and Ogren (2010)–Bond et al. (1999) as well as a random forest regression (RFR) machine learning algorithm to predict Babs values from the PSAP's filter-based measurements. The predicted Babs was compared against the reference Babs measured by the PASS. The RFR algorithm performed the best by yielding the lowest root mean square error of prediction. The algorithm was trained using input datasets from the PSAP (transmission and uncorrected absorption coefficient), a co-located nephelometer (scattering coefficients), and the Aerosol Chemical Speciation Monitor (mass concentration of non-refractory aerosol particles). A revised form of the Virkkula (2010) algorithm suitable for the SGP site has been proposed; however, its performance yields approximately 2-fold errors when compared to the RFR algorithm. To generalize the accuracy and applicability of our proposed RFR algorithm, we trained and tested it on a dataset of laboratory measurements of combustion aerosols. Input variables to the algorithm included the aerosol number size distribution from the Scanning Mobility Particle Sizer, absorption coefficients from the filter-based Tricolor Absorption Photometer, and scattering coefficients from a multiwavelength nephelometer. The RFR algorithm predicted Babs values within 5 % of the reference Babs measured by the multiwavelength PASS during the laboratory experiments. Thus, we show that machine learning approaches offer a promising path to correct for biases in long-term filter-based absorption datasets and accurately quantify their variability and trends needed for robust radiative forcing determination.

54 ENVIRONMENTAL SCIENCES↗

A summary of air sampler filter performance data: Bladewerx Speclon 5(TM) and Millipore FMLW047 5um

Bladewerx™ LLC (Rio Rancho, NM) manufactures instrumentation, neutron shielding and activation foils for the radiation protection industry. Specializing in portable alpha/beta air monitors and sample counters, Bladewerx is the source of Speclon 5™ PTFE filter media that they recommend for high-resolution alpha spectroscopy. Los Alamos National Laboratory (LANL) utilizes Speclon™ filter material in CAM (Continuous Air Monitor) samplers for workplace air monitoring. Millipore FMLW (5μm) filters are also used at Los Alamos, and a comparison of the two filter types has been requested. For filter face air velocities from 0.066 m/s to 1.5 m/s, the aerosol collection efficiency (for 0.3 μm particle diameters) and the filter pressure drops were measured. The FWHM (full width half maximum) of alpha spectroscopy peaks was also determined, using naturally occurring radon progeny at an alpha energy of 6 MeV.

61 RADIATION PROTECTION AND DOSIMETRY↗

A filtering strategy for the numerical convergence of radiation transport through purely absorbing particle clouds

Radiation transport through particle clouds plays a major role in many engineering applications. Here in this paper, we study this problem by means of solving the radiative transport equation (RTE) on a Eulerian continuous domain. The particle clouds are generated through direct numerical simulation of Navier-Stokes equations coupled with Lagrangian particle transport at different Stokes numbers. We confirm the earlier observation noted in the literature that the solution to the RTE on Eulerian mesh diverges when the Eulerian mesh size is of the order of the particle diameter. This observation is often called the homogenization error stemming from relegation of number density onto the Eulerian domain. In order to circumvent this divergence problem, we propose a filtering strategy that spreads the information of the particles to the neighboring cells in a way that the representation of the particles remains the same even when the mesh size is smaller than that of the particle size. We show through our simulations that our filtering strategy solves the issue of homogenization error for the cases where the Beer-Bouger law is valid.

42 ENGINEERING↗

Coaxial charged particle energy analyzer

A non-dispersive electrostatic energy analyzer for electrons and other charged particles having a generally coaxial structure of a sequentially arranged sections of an electrostatic lens to focus the beam through an iris and preferably including an ellipsoidally shaped input grid for collimating a wide acceptance beam from a charged-particle source, an electrostatic high-pass filter including a planar exit grid, and an electrostatic low-pass filter. The low-pass filter is configured to reflect low-energy particles back towards a charged particle detector located within the low-pass filter. Each section comprises multiple tubular or conical electrodes arranged about the central axis. The voltages on the lens are scanned to place a selected energy band of the accepted beam at a selected energy at the iris. Voltages on the high-pass and low-pass filters remain substantially fixed during the scan.

Kelly, Michael A.↗

Collective Analysis of Alpha Particle Losses Due to Self-Absorption by Mass Loading on Radioactive Particulate Glass Fiber Filters

In this study, we derived a relationship between filter mass loading and the percent loss during analysis using the mass loading data collected from six previous studies of self-absorption. Components of mass loading include particulate dust, radioactive particulates, and filter material. In a research report published in 1984, Higby calculated a minimum burial depth for an alpha particle to be lost due to absorption (100% loss) of about 3.7 mg/cm 2 based on calculations for the range of 239-Pu alpha particles in glass fiber filters. From there, Higby concluded that a correction factor of 0.85 assumes approximately 15% losses in the count rate of both alpha and beta particles. In 2000, Luetzelschwab et al. recommended assuming a 40% loss at a loading of 3.3 mg/cm 2 and a 28% loss for a loading of 2.3 mg/cm 2 which included the frontal face mass of the filter. More recently, the 100% losses due to absorption were reported to be in the 10 mg/cm 2 range. Presented here is a trinomial relationship method of relating percent loss due to self-absorption to filter mass loading, based on data reported by Higby, Luetzelschwab et al., Huang et al., Barnett et al., Smith et al., and Hogue et al. Under normal operating conditions at the stacks monitored by Effluent Management, the mass loading of sample filters averages 0.09 ± 0.12 (2s) mg/cm 2 (excluding negative values and outliers) and ranges from 0 mg/cm 2 to 0.24 mg/cm 2 . Based on current mass loading results for Effluent Management stack sample filters, the forced-zero trinomial relationship method estimated self-absorption losses of less than 5%. Because American National Standards Institute/Health Physics Society N13.1-2011 guidelines indicate a correction factor should be used when the penetration of radioactive material into the collection media or self-absorption of radiation by the material collected would reduce the count rate by more than 5%, it is possible continued application of a correction factor to the Effluent Management stack samples is no longer necessary. Nevertheless, continuing to assign a correction factor at the 5% threshold (i.e., 0.95) would be a conservative approach.

36 MATERIALS SCIENCE↗

Chemical and structural characterization of particulate fallout isolated from air-filters

We report particulate nuclear fallout is the radioactive byproduct of a nuclear event formed by the mixture of proximate environmental materials with vaporized bomb debris. The fallout debris can be transported into the atmosphere during cloud rise, raining out locally and dispersing globally constituting a radiation hazard and contributing to the distribution of anthropogenic radionuclides in the environment. Questions remain on how entrainment of environmental material in the fireball affects fallout formation processes and radionuclide incorporation and distribution during cooling. To inform the characterization of fallout including the development of fallout size distributions and how radionuclides are incorporated into fallout debris where entrainment plays a role, we analyzed an archived historic US air-filter collected by aircraft in the aftermath of ground interacting nuclear tests. Particulate fallout collected on the filter was isolated and analyzed using scanning electron microscopy (SEM), transmission electron microscopy (TEM) and NanoSIMS (Secondary Ion Mass Spectrometry) to determine chemistry, structure, morphology, and size of the particles. Results demonstrate that the particles isolated from the filter have spherical shape, display complex internal structures, and are mainly composed of Fe and Si oxides. In these spherical particles, Pu is preferentially associated with Fe-rich composition. The characterization of fallout particulate samples can provide information on nucleation and particle growth from the vapor phase to improve modeling and simulation of fallout hazards.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Ultrafine particle and fiber production in microgravity

In a system and method for producing ultrafine particles and ultrafine fibers of a given source material by evaporating and condensing the material in a gas atmosphere that includes inert gas. A smaller, more narrow size distribution is accomplished by producing the particles and fibers in a microgravity environment in order to reduce particle coalescence caused by convection currents. Particle coalescence also is reduced in an Earth gravity environment by controlling the convection currents. Condensed particles are collected either by providing an electrostatic field or a spatially varying magnetic field or by causing the gas to move through a filter which collects the particles. Nonferromagnetic material fibers are produced and collected by electrodes which produce an electro- static field. Ferromagnetic particles are collected by spatially varying magnetic fields.

Webb, George W.↗

IPN Absorption Coefficients

The dataset contains aerosol light absorption and scattering coefficients measured by three single-wavelength Integrated Photoacoustic Nephelometers (IPN). The absorption coefficients were measured at 405, 721, and 1047 nm, while the scattering coefficients were measured at 405 and 721 nm. The single scattering albedo (SSA) at 405 and 721 nm were also calculated from the IPN measurements. The three IPNs shared a common inlet without impactor/cyclone in July; in August, a PM2.5 cyclone inlet was installed to reduce measurement noise and improve data quality. The 721-nm IPN experienced laser shutdown issues, causing missing of a large fraction of the 721-nm measurements, especially in July. As described before, the 721-nm laser issue was less frequent in August after the cyclone installation, improving the data completeness and quality. The IPN raw data were noisy, making identifying patterns and trends difficult; therefore, the hourly average data are recommended over the raw data. The hourly average data were cross-checked with the filter-based TAP and PSAP measurements, which showed that their patterns, trends, and peaks matched. However, due to the differences in working mechanisms and principles of the filter-based and photoacoustic particle-phase instruments, the IPN measurements are lower than the filter-based measurements despite that they have consistent patterns, trends, and peaks.

54 ENVIRONMENTAL SCIENCES↗

A novel methodology for assessing the hygroscopicity of aerosol filter samples

Abstract. Due to US regulations, concentrations of hygroscopic inorganic sulfate and nitrate have declined in recent years, leading to an increased importance of the hygroscopic nature of organic matter (OM). The hygroscopicity of OM is poorly characterized because only a fraction of the multitude of organic compounds in the atmosphere is readily measured, and there is limited information on their hygroscopic behaviors. Hygroscopicity of aerosol is traditionally measured using a humidified tandem differential mobility analyzer (HTDMA) or electrodynamic balance (EDB). EDB measures water uptake by a single particle. For ambient and chamber studies, HTDMA measurements provide water uptake and particle size information but not chemical composition. To fill this information gap, we developed a novel methodology to assess the water uptake by particles collected on Teflon filters. This method uses the same filter sample for both hygroscopicity measurements and chemical characterization, thereby providing an opportunity to link the measured hygroscopicity with ambient particle composition. To test the method, hygroscopic measurements were conducted in the laboratory for ammonium sulfate, sodium chloride, glucose, and malonic acid, which were collected on 25 mm Teflon filters using an aerosol generator and sampler. Constant-humidity solutions (CHSs), including potassium chloride, barium chloride dihydrate, and potassium sulfate, were employed in a saturated form to maintain the relative humidity (RH) at approximately 84 %, 90 %, and 97 % in small chambers. Our preliminary experiments revealed that, without the pouch, water uptake measurements were not feasible due to rapid water loss during weighing. Additionally, we observed some absorption by the aluminum pouch itself. To account for this, concurrent measurements were conducted for both the loaded and the blank filters at each RH level. Thus, the dry loaded and blank Teflon filters were placed in aluminum pouches with one side open and in RH-controlled chambers for more than 24 h. The wet loaded samples and wet blanks were then weighed using an ultramicrobalance to determine the water uptake by the respective compound and the blank Teflon filter. The net amount of water absorbed by each compound was calculated by subtracting the water uptake of the blank filter from that of the wet loaded filter. Hygroscopic parameters, including the water-to-solute (W / S) ratio, molality, mass fraction solute (mfs), and growth factors (GFs), were calculated from the measurements. The results obtained are consistent with those reported by the Extended Aerosol Inorganics Model (E-AIM) and previous studies utilizing HTDMA and EDB for these compounds, highlighting the accuracy of this new methodology. This new approach enables the hygroscopicity and chemical composition of individual filter samples to be assessed so that in complex mixtures, such as chamber and ambient samples, the total water uptake can be parsed between the inorganic and organic components of the aerosol.

54 ENVIRONMENTAL SCIENCES↗

Reconstruction of Charged Particle Tracks in Realistic Detector Geometry Using a Vectorized and Parallelized Kalman Filter Algorithm

One of the most computationally challenging problems expected for the High-Luminosity Large Hadron Collider (HL-LHC) is finding and fitting particle tracks during event reconstruction. Algorithms used at the LHC today rely on Kalman filtering, which builds physical trajectories incrementally while incorporating material e ects and error estimation. Recognizing the need for faster computational throughput, we have adapted Kalman-filterbased methods for highly parallel, many-core SIMD and SIMT architectures that are now prevalent in high-performance hardware. Previously we observed significant parallel speedups, with physics performance comparable to CMS standard tracking, on Intel Xeon, Intel Xeon Phi, and (to a limited extent) NVIDIA GPUs. While early tests were based on artificial events occurring inside an idealized barrel detector, we showed subsequently that our mkFit software builds tracks successfully from complex simulated events (including detector pileup) occurring inside a geometrically accurate representation of the CMS-2017 tracker. Here, we report on advances in both the computational and physics performance of mkFit, as well as progress toward integration with CMS production software. Recently we have improved the overall eciency of the algorithm by preserving short track candidates at a relatively early stage rather than attempting to extend them over many layers. Moreover, mkFit formerly produced an excess of duplicate tracks; these are now explicitly removed in an additional processing step. We demonstrate that with these enhancements, mkFit becomes a suitable choice for the first iteration of CMS tracking, and eventually for later iterations as well. We plan to test this capability in the CMS High Level Trigger during Run 3 of the LHC, with an ultimate goal of using it in both the CMS HLT and oine reconstruction for the HL-LHC CMS tracker.

Cerati, Giuseppe↗