Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pallet”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Atmospheric emission photometric imaging

A dual-channel video system mounted on a stabilized two-axis gimbal system (mounted on the pallet) with associated optics and data handling electronics described the low light flux observations are required for: (1) investigating ionospheric transport processes by observing Mg+ ions; (2) supporting magnetospheric electron bounce experiments; (3) measuring electron cross sections for selected atmospheric species; (4) detecting small particle contamination; and (5) studying natural auroras.

Mende, S. B.↗

Advanced biostack experiment

The Advanced Biostack Experiment is described. The objectives are: (1) to confirm, complement, and enlarge the information obtained from the previous experiments by applying improved and advanced methods of localization and physical and biological evaluation, performing advanced experiments based on these data, and including additional biological specimens and additional radiation detectors; (2) to determine the biological importance of nuclear disintegration stars; (3) to determine the interference of HZE particle induced effects with those of other space flight factors (e.g., weightlessness); and (4) to determine the distribution of HZE particles and of disintegration stars at different locations inside the module and on the pallet.

Buecker, H.↗

Measurements by the plasma diagnostics package on STS-3

A comprehensive set of measurements about the orbiter environment are provided by the plasma diagnostics package (PDP). Ion and electron particle densities, energies, and spatial distribution functions; ion mass for identification of particular molecular ion species; and magnetic fields, electric fields and electromagnetic waves over a broad frequency range are studied. Shuttle environmental measurements will be made both on the pallet and, by use of the remote manipulator system (RMS), the PDP will be maneuvered in and external to the bay area to continue environmental measurements and to carry on a joint plasma experiment with the Utah State University fast-pulsed electron generator. Results of orbiter environment EMI measurements and S-band field strengths as well as preliminary results from wake search operations indicating wake boundary identifiers are reported.

Shawhan, S. D.↗

Electric power needs in space

The power requirements for specific float zone experiments in space are presented. Power figures for the Space Shuttle and projected available power for advanced vehicles are given. The following power related trends are derived: (1) float zone processing of up to 5 cm diameter silicon and 16.0 cm diameter cadmium telluride can be conducted on a Shuttle pallet mission; (2) float zone processing of up to 8.5 cm diameter silicon for 70% total heating efficiency can be conducted on the initial MEC/space platform; (3) projected available host vehicle power for float zone sample heating; (4) induction heating is found to be the most promising heating method; (5) process control and ease of equipment integration into the host vehicle influence heating method selection.

Waltz, D. M.↗

Investigations in cosmic and gamma ray astronomy and nuclear instruments

The Nuclear Radiation Monitor (NRM) is flying on the Spacelab 2 vehicle as part of a set of instrumentation designed to measure the ambient physical environment on Spacelab in orbit. The NRM measures the natural and induced gamma ray activity. The instrument is constituted of a 25 sq in (NaI (T1)) crystal viewed with a single phototube and surrounded by a plastic anticoincidence shield. It is mounted on a pedestal and placed, with its electronics, on the Spacelab pallet. The detector head was designed and a development model fabricated and tested. Extensive software studies for on board and GSE microprocessors for use with the NRM were also made.

Gregory, J. C.↗

Towards understanding solar flares

Instrumentation and spacecraft payloads developed at Lockheed for solar flare studies are reviewed, noting the significance of the observations for adding to a data base for eventual prediction of the occurrence of flares and subsequent radiation hazards to people in space. Developmental work on the two solar telescopes on board the Skylab pallet was performed at a Lockheed facility, as was the fabrication of very-large-area proportional counter for flights on the Aerobee rocket in 1967. The rocket work led to the fabrication of the Mapping X Ray Heliometer on the Orbiting Solar Observatory and the X Ray Polychromator for the Solar Maximum Mission. The Polychromator consists of a bent crystal spectrometer for high time resolution flare studies over a wide field of view, and a flat crystal spectrometer for simultaneous polychromatic imaging at 7 different X ray wavelengths.

Acton, L. W.↗

U.S. mission plans for Spacelab

Mission configurations, instrumentation, and objectives for Spacelab sorties on board the Shuttle beginning in Sept. 1983 are reviewed. The first two flights will serve to verify the Spacelab systems and will be followed by operational status, including the fifth flight, which will be a reimbursible venture. Scientific investigations in the fields of atmospheric physics and environmental observation, space plasma physics, astronomy and solar physics, materials processing, and life sciences will be performed using the habitable long module, instrument pallets, and/or an instrument igloo mounted in the payload bay. Instrumentation, such as the imaging spectrometric observatory, which was developed in the U.S., will originate in either the U.S. or Europe. Details of the first four Spacelab flights are presented, noting that the OSS-3 through -7 missions will feature the first time that entire NASA payloads have returned to space.

Sander, M. J.↗

The tethered retrievable platform concept and utilization

Main components of the current configuration of a proposed tethered satellite system (TSS) for deploying instrumentation up to 100 km upward or downward from the Orbiter in LEO are described. The TSS consists of the Deployer Module, the Tether, and the Satellite Module, and remains connected to the equipment in the Orbiter bay for the entire mission. The Deployer Module is mounted on a pallet, and has a boom, a tether control mechanism, and a tether control capability, in addition to data acquisition and control systems. The Satellite Module features a thermal control, electrical power and distribution, data management and communication, attitude determination, propulsion, and payload capability. Deployment is unpowered, taking advantage instead of gravity gradients to move the payload from the Orbiter. Safety features include a cutter mechanism to disengage the tether from the Orbiter if retrieval of the payload is judged to endanger the crew and the Orbiter.

Laue, J. H.↗

Using computer graphics to enhance astronaut and systems safety

The Operator Station Design System (OSDS), a technique of applied computer graphics featuring a flexible interactive software package, is presented in terms of man-machine analyses, flight operations, and systems engineering. In man-machine analyses, the OSDS was used to determine if viewing from the Shuttle Remote Manipulator System was satisfactory and to identify requirements for a pallet-mounted television camera. In another study, extravehicular activity was analyzed using the example of emergency access to latches should they fail in orbit. In terms of flight operations, OSDS can be used to evaluate array monitoring of a solar array power system complex and to provide animated scenarios of mission operations. The most important application of OSDS is in relation to systems engineering, as OSDS can be used to analyze spacecraft and payload design and integration. Payload configurations are included.

Brown, J. W.↗

The OSS-1/STS-3 mission

Integration, test, flight operations, program and science management, and experiment results from the OSS-1/STS-3 flight are reviewed. The experimental pallet, manufactured by ESA members, carried instrumentation for astronomy, space plasma studies, physics, planetology, solar physics, and life sciences. The ability of the equipment to operate in a worst-case Orbiter thermal environment was tested, as was the plasma environment around the Orbiter. The solar UV spectral irradiance monitor microprocessor was found to reset concurrently with start-up of the Shuttle hydraulic pumps. Degradations were also observed in one of the three solar flare X ray polarimeter modules, the thermal cannister experiment microprocessor, and the scientific data recorder no. 2. The Orbiter was determined to perform well during firing of an electron beam. A contamination monitor recorded matter accretion to be dependent on the solar orientation of the Orbiter. Finally, the distribution of the responsibilities and tasks for mission management are reviewed.

Kissin, K.↗

Partial-Payload Support Structure

Partial-payload support structure (PPSS) is modular, bridge like structure supporting experiments weighing up to 2 tons. PPSS handles such experiments more economically than standard Spacelab pallet system.

Mitchell, R.↗

An integrated user-oriented laboratory for verification of digital flight control systems: Features and capabilities

A Digital Flight Control Systems Verification Laboratory (DFCSVL) has been established at NASA Ames Research Center. This report describes the major elements of the laboratory, the research activities that can be supported in the area of verification and validation of digital flight control systems (DFCS), and the operating scenarios within which these activities can be carried out. The DFCSVL consists of a palletized dual-dual flight-control system linked to a dedicated PDP-11/60 processor. Major software support programs are hosted in a remotely located UNIVAC 1100 accessible from the PDP-11/60 through a modem link. Important features of the DFCSVL include extensive hardware and software fault insertion capabilities, a real-time closed loop environment to exercise the DFCS, an integrated set of software verification tools, and a user-oriented interface to all the resources and capabilities.

Defeo, P.↗

OSS-1/contamination monitor

A 20-cm high, 18-cm wide, and 30-cm long (8x7x12 inch) box weighing about 7 kg (15 lbs) and consuming about 7 watts of power was carried on the OSS-1 pallet to monitor the mass build-up or accretion of condensible, volatile materials on surfaces in the shuttle bay during all phases of ascent, on-orbit, and descent. Passively thermally controlled, the box holds two witness samples and four actively temperature controlled quartz crystal microbalances (TQCM) whose temperature can vary from -60 C to +80 C. Graphs show the accretion indicated by the TQCM during the launch and early orbital phase. Conditions during tail to the Sun, nose to the Sun, and bay to the Sun attitudes of the shuttle during STS-3 are reflected in temperatures indicated by the OSS-1 thermistor. These temperatures influence outgassing rates of various materials as well as measurements made by the contamination monitor package. The parameters that bear on TQCM measurements data are shown in graphs and discussed.

Kruger, R.↗

Test for contamination of MgF2 - coated mirrors

Graphs show preflight and postflight reflectivities in percent for exposed and covered mirrors carried on the OSS-1 payload pallet during STS-3. No changes greater than 1.8 sigma were observed except for a fingerprint. Weak evidence for degradation at 1216 A and 1600 A was found in several samples. There was no difference between flight mirrors and control mirrors. Covered samples suffered more than samples exposed to the Sun, but the differences are barely significant. The exposed side of the flight mirrors were somewhat dusty. No evidence was found for permanent solar-induced or shuttle-induced deterioration. There also was no evidence on oil-pumped vacuum versus oil-free vacuum during coating.

Bunner, A. N.↗

Vehicle charging and potential on the STS-3 mission

An electron gun with fast pulse capability was used in the vehicle charging and potential experiment carried on the OSS-1 pallet to study dielectric charging, return current mechanisms, and the techniques required to manage the electrical charging of the orbiter. Return currents and charging of the dielectrics were measured during electron beam emission and plasma characteristics in the payload bay were determined in the absence of electron beam emission. The fast pulse electron generator, charge current probes, spherical retarding potential analyzer, and the digital control interface unit which comprise the experiment are described. Results show that the thrusters produce disturbances which are variable in character and magnitude. Strong ram/wake effects were seen in the ion densities in the bay. Vehicle potentials are variable with respect to the plasma and depend upon location on the vehicle relative to the main engine nozzles, the vehicle attitude, and the direction of the geomagnetic field.

Williamson, R.↗

STS-3/OSS-1 Plasma Diagnostics Package (PDP) measurements of the temperature pressure and plasma

Designed to withstand the thermal extremes of the STS-3 mission through the use of heaters and thermal blankets, the plasma diagnostics package sat on the release/engagement mechanism on the OSS-1 payload pallet without a coldplate and was attached to the RMS for two extended periods. Plots show temperature versus mission elapsed time for two temperature sensors. Pressure in the range of 10 to the -3 power torr and 10 to the -7 power torr, measured 3 inches from the skin of the package is plotted against GMT during the mission. The most distinctive feature of the pressure profile is the modulation at the obit period. It was found that pressure peaks when the atmospheric gas is rammed into the cargo bay. Electric and magnetic noise spectra and time variability due to orbiter systems, UHF and S-band transmitter field strengths, and measurements of the ion spectra obtained both in the cargo bay and during experiments are plotted.

Shawhan, S. D.↗

STS-3/OSS-1 Plasma Diagnostics Package (PDP) measurements of Orbiter transmitter and subsystem electromagnetic interference

The plasma diagnostics package receiver system is described to identify the various antennas and to characterize the complement of receivers which cover the frequency range of 30 Hz to 800 Hz and S-band at 2200 + or - 300 MHz. Sample results are presented to show the variability of electromagnetic effects associated with the orbiter and the time variability of these effects. The electric field and magnetic field maximum and minimum field strength spectra observed during the mission at the pallet location are plotted. Values are also derived for the maximum UHF transmitter and S-band transmitter field strengths. Calibration data to convert from the survey plots to actual narrowband and broadband field strengths are listed.

Shawhan, S. D.↗

Results of thermal environment measurements on the thermal cannister experiment and get away special enclosure

Because the OSS-1 pallet contained a variety of instruments with irregular surface geometry and properties which limited predictability, the total absorbed flux on thermal canister radiators was measured to determine heat rejection capability. The instrumentation and sensor cup design and locations for the thermal canister experiment are illustrated. Graphs show flux sensor history in hot and coal orbits. Kapton erosion is also considered. Results show that the flux levels measured in all STS attitudes are higher than predictions. In cold and moderate attitudes, flight results are a factor of two to three higher than predicts. In hot attitude, much better agreement occurred. It is concluded that in cold or moderate attitudes other sources may be contributing to added inputs (albedo, Earth shine, shuttle background). In hot attitude, smaller differences could be attributed to coatings assumptions or calculation uncertainty.

Ollendorf, S.↗