Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “outdoor lighting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Degradation in PV Encapsulant Strength of Attachment: An Interlaboratory Study Towards a Climate-Specific Test

Reduced strength of attachment of the encapsulant resulting from the outdoor environment, including ultraviolet (UV) radiation, may decrease photovoltaic (PV) module lifetime by enabling widespread corrosion of internal components. To date, few studies exist showing how the adhesion of PV components varies with environmental stress. We have conducted an interlaboratory experiment to provide an understanding that will be used to develop climatic specific module tests. Factors examined in the study included the UV light source (lamp type), temperature, and humidity to be proposed for use in accelerated aging tests. A poly (ethylene-co-vinyl acetate) (EVA) formulation often used in veteran PV installations was studied using a compressive shear test - to quantify the strength of attachment at the EVA/glass interface. Replicate laminated glass/polymer/glass coupon specimens were weathered at 12 institutions using a variety of indoor chambers or field aging. Shear strength, shear strain, and toughness were measured using a mechanical load-frame for the compressive shear test, with subsequent optical imaging and electron microscopy of the separated surfaces.

14 SOLAR ENERGY↗

Perovskite solar cells can take the heat

Solar panels must endure extreme conditions during their service lifetime. There are few other products, let alone pristine semiconductor electronics, that are manufactured today and expected to withstand decades of abuse from full exposure to outdoor elements, including harsh ultraviolet sunlight, rain and hail, and daily and seasonal thermal cycles. Over the past decade, a new class of semiconductors, known as metal halide perovskites, has emerged, which constitutes the light-absorbing material in solar panels and has made incredible advancements, potentially taking photovoltaics in new directions. Perovskite materials have been touted as a potential game changer for solar energy production.

14 SOLAR ENERGY↗

Validating Savings Claims of Cold Climate Zero Energy Ready Homes

This report details the validation methods used to analyze consumption at each of these homes. It includes a detailed end-use examination of consumptions from the following categories: 1) Heating, 2) Cooling, 3) Lights, Appliances, and Miscellaneous Electric Loads (LAMELS) along with Domestic Hot Water Use, 4) Ventilation, and 5) PV generation. A utility bill disaggregation method, which allows a crude estimation of space conditioning loads based on outdoor air temperature, was also performed and the results compared to the actual measured data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A preliminary implementation of metabolic-based pH control to reduce CO 2 usage in outdoor flat-panel photobioreactor cultivation of Nannochloropsis oceanica microalgae

A crucial challenge associated with high-density, commercial-scale, outdoor microalgal cultivation is maintaining pH stability without excessive use of CO 2 buffering. This includes a media-dependent, intracellular metabolic proton imbalance leading to the alkalization or acidification of growth media that results when algae consume, respectively, nitrate or ammonium ions. Feeding these two nitrogen sources can theoretically achieve balanced proton metabolism as well as pH control that is economically more favorable as compared to CO 2 buffering or acid/base addition. To accomplish this, a fed-batch nutrient feeding strategy must be adopted as a component of a model-based pH control system, particularly in the case of ammonium preference. This work represents a preliminary study of the challenges of implementing a nitrogen metabolism based open-loop pH control strategy in the challenging environment of an outdoor photobioreactor at the DOE-ATP 3 testbed facility in Mesa, Arizona during the high solar insolation period of summer 2015. The approach was limited to twice daily fed-batch addition while accounting for ammonium-N preference in a background of nitrate-based algae growth media. Despite these limitations, growth achieved for a photobioreactor operated based on predicted metabolic nitrogen demand (PND) was comparable to ‘CO 2 -on-demand’ (CoD) for pH control. PND reduced CO 2 usage to b10% of CoD control, where the reduced buffering resulted in much greater pH fluctuations due to daily variations in light availability, and a much lower and more consistent media alkalinity (5.73–5.79 mEq/L) as compared to the CoD control (6.51–8.49 mEq/L). While this effort illustrates the utility of feed-forward model-based control, it further illustrates the need for far more sophisticated ‘real time’ monitoring and modeling to accommodate the dynamic outdoor conditions. In conclusion, a need for improved analytics for accurate closure of nitrogen mass balance is also indicated.

09 BIOMASS FUELS↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LeTID-Affected Cells from a Utility-Scale Photovoltaic System Characterized by Deep Level Transient Spectroscopy

Photovoltaic modules from a utility-scale field experienced power loss by light- and elevated temperature-induced degradation (LeTID). Samples of one of the affected monocrystalline silicon cells were cored and extracted from the module packaging and encapsulation. One of the cell fragments was processed using a regeneration cycle of applying short-circuit-rated current in forward bias at 85 degrees C for 2 weeks, while the other fragment was kept in its outdoor-degraded LeTID state. Both samples were scribed to form 2-mm diameter isolated areas using a femtosecond-pulse-width laser micromachining system. Both isolated areas contained front grid line segments which were wire bonded to larger contact pads, and the samples were probed in a cryostat linked to a deep-level transient spectroscopy (DLTS) system. Using DLTS, a majority-carrier, hole-trap defect was detected on each sample with an activation energy of 0.42 eV. The LeTID-degraded sample, however, had a larger signal corresponding to a trap density of 1.1x10^13 cm-3, which was about five times larger than the 2.1x10^12 cm-3 trap density of the regenerated sample.

charge carrier lifetime↗

The effects of outdoor air-side fouling on frost growth and heat transfer characteristics of a microchannel heat exchanger: An experimental study

Air source heat pumps have the potential to efficiently heat and cool buildings, but their effectiveness in many climates is limited by frost growth on the outdoor heat exchanger in heating mode. These heat exchanger coils are also subject to fouling from fibers and particulates outdoors. Frost and fouling have each independently been studied extensively, and newly available research on fouling provides a method to realistically foul the air-side of coils in the laboratory. The current paper uses this method to conduct the first laboratory study of the important interactions between fouling and frost growth for a heat pump outdoor coil. A microchannel heat exchanger is tested clean and fouled, with variations in fouling level, humidity, and initial face velocity of air. Air flow rate is allowed to vary with resistance, and a surprising result is that light fouling increases heat transfer and frost growth rates, even with a 3.5% reduction in initial airflow caused by the fouling. However, heavier fouling decreases both rates. When frost growth is normalized to heat transfer, it is found to be increased by fouling; i.e. the coil’s sensible heat ratio decreases.

42 ENGINEERING↗

Improving energy yield in photovoltaic modules with photonic structures

When installed outdoors, Si solar cells typically operate 20 – 30 K above ambient conditions. These elevated operating temperatures lead to diminished performance, reducing efficiency by ~0.4%/K for crystalline Si cells and decreasing module lifetime. Since much of the elevated temperature of the modules derives from parasitic absorption of sub-bandgap sunlight by the contacts, encapsulants, or other materials, reflectors that remove the sub-bandgap radiation from the module before it is absorbed promise to reduce the operating temperature. However, there are many competing strategies to reject this light: selective reflectors could be integrated into the outer module glass, at the textured Si-encapsulant interface, or on the rear. Furthermore, many of these approaches are complex and expensive to fabricate. The issue of heating can be even more critical in bifacial modules: high fractions of rear irradiance can lead to higher operating temperatures. Prior to this project, relatively little was known about the optical strategies for temperature reduction in bifacial modules. The goal of this project was to quantitatively assess optical strategies for improving the energy yield via a combination of improved anti-reflection and sub-bandgap light rejection. We studied two complementary concepts: the performance of ideal structures to determine the upper limits to performance, and low-complexity structures made from standard materials as cost-effective implementations. We also studied the performance of these reflectors in different types of modules, including Al BSF, PERC, and bifacial. Here we build from our prior accomplishments in developing mirror optimization techniques, and make use of simulation methods that accurately capture the optical properties of the modules throughout the visible and near-infrared spectrum. We connect these optical properties to energy yield under realistic, outdoor conditions. We also experimentally fabricated mirrors, incorporated them into mini-modules, and performed outdoor testing of performance at NREL. We found definitively that spectrally-selective mirrors on the outside of the module cover glass offer the best performance, both under ideal conditions and for realistic, low- complexity mirrors. Mirrors at the Si cell/encapsulant interface are limited by the multiple reflections needed to remove sub-bandgap light. Mirrors at the cell surface and mirrors on the rear also cannot remove all the sub-bandgap light, since parasitic absorption also occurs in the cover glass, encapsulant, and front contacts, depending on the module configuration. Also, cell texturing places higher demands on any cell-surface mirror because multiple interactions with the mirror are required to reject sub bandgap light which compounds losses. For bifacial modules, mirrors on the back do provide additional cooling and energy yield improvements, and the mirrors can have the same structure. In the monofacial case up to 3.3K of cooling is possible for mirrors on the front, compared to 2.2K at the cell surface and 1.2K at the rear. For bifacial modules, up to 2.4K of cooling is possible when mirrors are included at both the front and back. Our realistic designs utilize 4 – 6 layers of common photovoltaic materials such as SiO 2 , TiO 2 , and SiN x , making them more cost effective. Finally, we used our models to study thermal management in bifacial modules with different back lamination materials, finding that glass-glass laminated modules operated hotter than equivalent glass-polymer backsheet modules, due solely to the increased absorption of light incident from the rear of the module. Improving the energy yield by 2%, which is achievable with these realistic designs, would lead to LCOE reductions of $0.03/kWh by 2030. These benefits make photovoltaic panels more accessible to the public and may reduce associated maintenance costs.

14 SOLAR ENERGY↗

Fabrics Protect Sensitive Skin from UV Rays

Late Johnson Space Center engineer Dr. Robert Dotts headed a team to develop cool suits for children suffering from life-threatening sun sensitivities. Dotts hoped to develop ultraviolet-blocking technology in a fabric that -- unlike in a bulky space suit -- could remain comfortable, light, and breathable in the sun and heat. The team worked with SPF 4 US LLC (SPF) of Madison, Wisconsin to design ultraviolet-blocking cool suits, which protect sun-sensitive patients and enable them to experience life outdoors safely. Using knowledge gained during the NASA collaboration, SPF created an entire line of ultraviolet-blocking apparel.

Source record↗

Performance of Variable Capacity Heat Pumps in a Mixed Humid Climate

Variable capacity heat pumps represent the next wave of technology for heat pumps. In this report, the performance of two variable capacity heat pumps (HPs) is compared to that of a single or two stage baseline system. The units were installed in two existing research houses located in Knoxville, TN. These houses were instrumented to collect energy use and temperature data while both the baseline systems and variable capacity systems were installed. The homes had computer controlled simulated occupancy, which provided consistent schedules for hot water use and lighting. The temperature control and energy use of the systems were compared during both the heating and cooling seasons. Multiple linear regression models were used along with TMY3 data for Knoxville, TN in order to normalize the effect that the outdoor air temperature has on energy use. This enables a prediction of each system's energy use over a year with the same weather. The first system was a multi-split system consisting of 8 indoor units and a single outdoor unit. This system replaced a 16 SEER single stage HP with a zoning system, which served as the baseline. Data was collected on the baseline system from August 2009 to December 2010 and on the multi-split system from January 2011 to January 2012. Soon after the installation of the multi-split system, some of the smaller rooms began over-conditioning. This was determined to be caused by a small amount of continuous refrigerant flow to all of the indoor units when the outdoor unit was running regardless of whether they were calling for heat. This, coupled with the fact that the indoor fans run continuously, was providing enough heat in some rooms to exceed the set point. In order to address this, the indoor fans were disabled when not actively heating per the manufacturer's recommendation. Based on the measured data, the multi-split system was predicted to use 40% more energy in the heating season and 16% more energy in the cooling season than the baseline system, for the typical meteorological year weather data. The AHRI ratings indicated that the baseline system would perform slightly better than the multi-split system, but not by as large of a margin as seen in this study. The multi-split system was able to maintain more consistent temperature throughout the house than the baseline system, but it did allow relative humidity levels to increase above 60% in the summer. The second system was a split system with an inverter driven compressor and a single ducted air handler. This unit replaced a 16 SEER two stage HP with a zoning system. Data was collected on the baseline system from July 2009 to November 2010 and on the ducted inverter system from December 2010 to January 2012. The ducted inverter system did not offer a zone controller, so it functioned as a single zone system. Due to this fact, the registers had to be manually adjusted in order to better maintain consistent temperatures between the two levels of the house. The predicted heating season energy use for the ducted inverter system, based on the measured energy use, was 30% less than that of the baseline system for the typical meteorological year. However, the baseline system was unable to operate in its high stage due to a wiring issue with the zone controller. This resulted in additional resistance heat use during the winter and therefore higher energy use than would be expected in a properly performing unit. The AHRI ratings would indicate that the baseline system would use less energy than the ducted inverter system, which is opposite to the results of this study. During the cooling season, the ducted inverter system was predicted to use 23% more energy than the baseline system during the typical meteorological year. This is also opposite of the results expected by comparing the AHRI ratings. After a detailed comparison of the ducted inverter system's power use compared to that of a recently installed identical system at a retro-fit study house, there is concern that the unit is not operating as intended. The power use and cycles indicate that the unit is performing more like a single stage unit than a variable capacity unit. Analysis of the data indicates that a change in operating behavior occurred during a service call shortly after the installation of the unit. The logbook only indicates that refrigerant charge was added, but does not indicate any other change. This is being investigated further. While the energy comparison results of these two variable capacity heat pumps is generally underwhelming, it is difficult to draw any hard conclusions about the maximum attainable efficiency of these units when optimally installed. Both units appear to have undesirable conditions associated with the installation or operation, which could have had an adverse effect on their energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tests of Solar-Array Encapsulants

Materials tested for degradation by heat and light. Report presents early results of continuing series of photothermal aging tests of some candidate encapsulating materials for solar photovoltaic modules. Objectives of testing program: contribute to development of durable, low-cost encapsulants and predict lifetimes of encapsulated photovoltaic modules placed outdoors. Toward these ends, tests designed to reveal physical and chemical degradation mechanisms that affect encapsulants.

Liang, R. H.↗

Bulb Miser

The Bulb-Miser was developed during NASA's Apollo program to protect the Saturn launch vehicle from electrical current surge. It is now being produced for the commercial market by Bulb-Miser, Inc., Houston, Texas. Technically known as a "temperature compensating thermistor," the Bulb-Miser is a simple, inexpensive device which looks like a washer about the size of a quarter. It is slipped between bulb and socket and can be used with any incandescent bulb that screws into a standard socket. In addition to delaying burnout, the Bulb-Miser also offers some reduction of electrical energy. But the economy of the device goes beyond energy use or bulb cost; to big users of bulbs, it makes possible substantially lower maintenance labor costs. One field test involving an apartment complex showed that it took two men 30 man hours monthly to replace light bulbs; after Bulb-Miser installation only nine man hours a month were needed. Bulb-Misers are used not only in private homes but also by hospitals, schools, hotels and motels, restaurants, banks and firms providing contract maintenance for large outdoor electric signs. The broadest use is in industrial facilities; the list of big companies which have purchased the Bulb-Miser reads like a Who's Who of American industry.

Source record↗

The Impact of Indoor and Outdoor Radiometer Calibration on Solar Measurements

This study addresses the effect of calibration methodologies on calibration responsivities and the resulting impact on radiometric measurements. The calibration responsivities used in this study are provided by NREL's broadband outdoor radiometer calibration (BORCAL) and a few prominent manufacturers. The BORCAL method provides outdoor calibration responsivity of pyranometers and pyrheliometers at a 45 degree solar zenith angle and responsivity as a function of solar zenith angle determined by clear-sky comparisons to reference irradiance. The BORCAL method also employs a thermal offset correction to the calibration responsivity of single-black thermopile detectors used in pyranometers. Indoor calibrations of radiometers by their manufacturers are performed using a stable artificial light source in a side-by-side comparison of the test radiometer under calibration to a reference radiometer of the same type. These different methods of calibration demonstrated 1percent to 2 percent differences in solar irradiance measurement. Analyzing these values will ultimately enable a reduction in radiometric measurement uncertainties and assist in developing consensus on a standard for calibration.

14 SOLAR ENERGY↗

Radiological Scouting, Monitoring and Inspection Using Drones

Human populations and natural ecosystems are bound to be exposed to ionizing radiation from the deposition of artificial radionuclides resulting from nuclear accidents, nuclear devices or radiological dispersive devices (“dirty bombs”). On the other hand, Naturally Occurring Radioactive Material industries such as phosphate production or uranium mining, contribute to the on site storage of residuals with enhanced concentrations of natural radionuclides. Therefore, in the context of the European agreements concerning nuclear energy, namely the European Atomic Energy Community Treaty, monitoring is an essential feature of the environmental radiological surveillance. In this work, we obtain 3D maps from outdoor scenarios, and complete such maps with measured radiation levels and with its radionuclide signature. In such scenarios, we face challenges such as unknown and rough terrain, limited number of sampled locations and the need for different sensors and therefore different tasks. We propose a radiological solution for scouting, monitoring and inspecting an area of interest, using a fleet of drones and a controlling ground station. First, we scout an area with a Light Detection and Ranging sensor onboard a drone to accurately 3D-map the area. Then, we monitor that area with a Geiger–Müller Counter at a low-vertical distance from the ground to produce a radiological (heat)map that is overlaid on the 3D map of the scenario. Next, we identify the hotspots of radiation, and inspect them in detail using a drone by landing on them, to reveal its radionuclide signature using a Cadmium–Zinc–Telluride detector. We present the algorithms used to implement such tasks both at the ground station and on the drones. The three mission phases were validated using actual experiments in three different outdoor scenarios. We conclude that drones can not only perform the mission efficiently, but in general they are faster and as reliable as personnel on the ground.

Pinto, Luís Ramos (ORCID:0000000319975484)↗

Spatial and temporal variations in indoor environmental conditions, human occupancy, and operational characteristics in a new hospital building

The dynamics of indoor environmental conditions, human occupancy, and operational characteristics of buildings influence human comfort and indoor environmental quality, including the survival and progression of microbial communities. A suite of continuous, long-term environmental and operational parameters were measured in ten patient rooms and two nurse stations in a new hospital building in Chicago, IL to characterize the indoor environment in which microbial samples were taken for the Hospital Microbiome Project. Measurements included environmental conditions (indoor dry-bulb temperature, relative humidity, humidity ratio, and illuminance) in the patient rooms and nurse stations; differential pressure between the patient rooms and hallways; surrogate measures for human occupancy and activity in the patient rooms using both indoor air CO₂ concentrations and infrared doorway beam-break counters; and outdoor air fractions in the heating, ventilating, and air-conditioning systems serving the sampled spaces. Measurements were made at 5-minute intervals over consecutive days for nearly one year, providing a total of ~8×10⁶ data points. Indoor temperature, illuminance, and human occupancy/activity were all weakly correlated between rooms, while relative humidity, humidity ratio, and outdoor air fractions showed strong temporal (seasonal) patterns and strong spatial correlations between rooms. Differential pressure measurements confirmed that all patient rooms were operated at neutral pressure. The patient rooms averaged about 100 combined entrances and exits per day, which suggests they were relatively lightly occupied compared to higher traffic environments (e.g., retail buildings) and more similar to lower traffic office environments. There were also clear differences in several environmental parameters before and after the hospital was occupied with patients and staff. Characterizing and understanding factors that influence these building dynamics is vital for hospital environments, where they can impact patient health and the survival and spread of healthcare associated infections.

54 ENVIRONMENTAL SCIENCES↗

The Space Operations Simulation Center (SOSC) and Closed-loop Hardware Testing for Orion Rendezvous System Design

The Space Operations Simulation Center (SOSC) at the Lockheed Martin (LM) Waterton Campus in Littleton, Colorado is a dynamic test environment focused on Autonomous Rendezvous and Docking (AR&D) development testing and risk reduction activities. The SOSC supports multiple program pursuits and accommodates testing Guidance, Navigation, and Control (GN&C) algorithms for relative navigation, hardware testing and characterization, as well as software and test process development. The SOSC consists of a high bay (60 meters long by 15.2 meters wide by 15.2 meters tall) with dual six degree-of-freedom (6DOF) motion simulators and a single fixed base 6DOF robot. The large testing area (maximum sensor-to-target effective range of 60 meters) allows for large-scale, flight-like simulations of proximity maneuvers and docking events. The facility also has two apertures for access to external extended-range outdoor target test operations. In addition, the facility contains four Mission Operations Centers (MOCs) with connectivity to dual high bay control rooms and a data/video interface room. The high bay is rated at Class 300,000 (. 0.5 m maximum particles/m3) cleanliness and includes orbital lighting simulation capabilities.

D'Souza, Christopher↗

Review of Potential–Induced Degradation in Bifacial Photovoltaic Modules

Bifacial modules are increasingly deployed in the field and are expected to represent half of the market share within 10 years. Their rear structure differs from monofacial modules to allow additional light absorption. However, it brings new reliability challenges to address. In particular, the risk of potential-induced degradation (PID) is increased as both module sides are impacted. Different PID processes have been identified in the literature: shunting type (PID-s), polarization type (PID-p), Na penetration type, and corrosion type (PID-c). Their occurrence depends on the photovoltaic system configuration as well as the module's materials. Apart from PID-s, PID processes are not well understood and extensive research is needed to elucidate the PID scenario and underlying mechanisms. Herein, current knowledge about PID processes and their impact on the main bifacial modules in the market are gathered with the aim to guide future research. Bifacial module technologies and leakage current paths leading to PID are described. Indoor and outdoor PID testing methods are detailed. For each bifacial module technology, the PID processes are investigated with their indicators, mechanism and recovery process. Furthermore, PID-impacting factors and limitation solutions are finally reported and a state of the art on PID modeling is presented.

14 SOLAR ENERGY↗

Glass-particle adhesion-force-distribution on clean (laboratory) and contaminated (outdoor) surfaces

This article explores whether laboratory-clean samples are representative of real outdoor surfaces – often covered in dust and other contaminants – with respect to adhesion properties, which ultimately affect particle resuspension. In this study, Atomic Force Microscopy (AFM) was used to measure the adhesion force between a clean, smooth glass particle (5 µm in diameter) and two glass slides, one prepared according to common laboratory practices (hereafter, clean glass) and a second one left outdoors for six weeks (hereafter, contaminated glass). It was found that the adhesion force distribution was bimodal for the clean glass while it showed three peaks for the contaminated glass. For both surfaces, the adhesion force showed a peak at very low adhesion values (< 100 nN) representing 1.2% of the measurements for the clean glass and 58% for the contaminated glass. This low-adhesion peak is important because it represents the particles that would be resuspended first even in light winds. The low adhesion-force measurements were associated with the presence of contaminants on the surface. Another notable difference between the adhesion force distributions was a long tail at high adhesion forces for clean glass (up to ~1900 nN) and the absence of the tail for the contaminated glass, which had a maximum adhesion force of 950 nN. The mean adhesion force on the contaminated glass was also lower than on the clean glass (206 ± 240 nN vs. 516 ± 354 nN). These observations indicate that the adhesion force distribution between a 5-µm smooth and clean glass sphere and the outdoor contaminated glass surface is quite different from that of the clean glass surface. Hence, one should be cautious when using adhesion force measurements from clean surfaces to estimate particle resuspension from outdoor surfaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗