Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “oregon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

SciDAC3 SUPER Performance Institute, University of Oregon Contributions (Final Report)

The SciDAC-3 Institute for Sustained Performance, Energy, and Resilience (SUPER) focused on developing technology and leveraging expertise towards ensuring that computational scientists could successfully exploit existing and emerging DOE high performance computing systems. To achieve this goal, SUPER was organized into research thrusts focusing on performance engineering, auto-tuning, performance tools, energy efficiency, resilience and multi-objective optimization, with a target of facilitating effective utilization of near term HPC systems. As described in this summary document, our teams’ significant insights into both application- and architecture-awareness drove numerous innovations across our stated research areas, while significantly improving the performance, portability, and functionality of numerous SciDAC partnership applications, enabling scientific simulation at unprecedented scale. Additionally, the tools, methodologies, and collaborations developed under this project will continue paying dividends as we face the challenges of forthcoming multi-petascale and exascale computing technologies.

97 MATHEMATICS AND COMPUTING↗

Electrochromic Window Demonstration at the 911 Federal Building, 911 Northeast 11th Avenue, Portland, Oregon

Switchable electrochromic (EC) windows are part of a new class of dynamic, energy-efficient technologies that enable real-time, active load management in response to weather conditions and the unique operating conditions of individual buildings. Owners can now specify a solid-state technology that reacts to various stimuli like the skin of a living entity. The technology can be controlled to address multiple criteria to achieve a more optimal energy-efficient and comfortable indoor environment than one with static or manually operated technologies. Inputs can include data on outdoor solar conditions, utility rates, occupancy status, heating, ventilation, and air conditioning (HVAC), or operating emergency or security mode. The outputs then dictate how the EC window is controlled, whether as a self-contained autonomous unit that achieves specific zonal objectives or as a part of an integrated system designed to address whole building, campus and grid-related goals. Since windows typically have a 30-year life, these dynamic qualities enable the building to be adaptable and more resilient as the environmental, operating and economic context evolves.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Results from Oregon State University 1 MW TRIGA reactor irradiation of uranium-238

We are studying short-lived fission product yields to improve the nuclear databases currently available to the nuclear physics community. There are three general energy groups that are cited in the nuclear databases; thermal neutron spectrum, fission neutron spectrum and mono-energetic 14 MeV. Each neutron energy spectrum produces different fission fragment distributions. The differences between thermal and fission neutron spectrum is several MeV of energy. Thermal represents neutron energies arounds 0.026 eV. Fission neutron spectrum refers to a Watt fission neutron spectrum with a mean energy of approximately 1 MeV. 14 MeV is the result mono-energetic with a small spread in energies (~0.1-0.3 MeV) usually.

42 ENGINEERING↗

Cost Effectiveness of ASHRAE Standard 90.1-2016 for the State of Oregon

This report describes the methodology and results of a state cost-effectiveness analysis of ASHRAE Standard 90.1-2016. Moving to the Standard 90.1-2016 edition from Standard 90.1-2013 is found to be cost-effective for the state. Annual energy cost savings, added construction costs, and life-cycle costs are all described and presented here for various building types and climate zones.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cost-Effectiveness of ANSI/ASHRAE/IES Standard 90.1-2019 for Oregon

This report describes the methodology and results of a state cost-effectiveness analysis of ASHRAE Standard 90.1-2019. Moving to the Standard 90.1-2019 edition from Standard 90.1-2016 is found to be cost-effective for the state. Annual energy cost savings, added construction costs, and life-cycle costs are all described and presented here for various building types and climate zones.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Determining Adult Pacific Lamprey Abundance and Spawning Habitat in the Lower Deschutes River Sub-Basin, Oregon, 2008 Annual Report.

An adult Pacific lamprey (Lampetra tridentata) escapement estimate was generated in the lower Deschutes River during run year 2008. This included a mark-recapture study to determine adult abundance and a tribal subsistence creel. Fish measuring less than 10.5 cm received two marks for the mark-recapture estimate while those measuring greater than 10.5 cm were surgically implanted with radio transmitters to monitor migration upstream of Sherars Falls (rkm 70.4). Radio telemetry was used to determine habitat, focal spawning areas and spawn timing. All fish were collected at the Sherars Falls fish ladder from July-October 2008 using a long handled dip-net. Escapement was generated using a two event mark-recapture experiment. Adult lamprey populations were estimated at 3,471 (95% CI = 2,384-5,041; M = 101; C = 885 R = 25) using Chapman's modification of the Peterson estimate. The relative precision around the estimate was 31.42. Tribal harvest was approximately 806 adult lamprey (95% CI = +/- 74) with a total escapement of 2,669. Fourteen lamprey received radio tags and were released at Lower Blue Hole recreation site (rkm 77.3). Movement was recorded by mobile, fixed site and aerial telemetry methods. Upstream movements of lamprey were documented from July through December 2008 with most lamprey over-wintering in the mainstem Deschutes River.

13 HYDRO ENERGY↗

Determining Lamprey Species Composition, Larval Distribution and Adult Abundance in the Deschutes River Subbasin, Oregon ; 2007 Annual Report.

We will report results of an ongoing project in the Deschutes River Subbasin to describe Pacific lamprey (Lampetra tridentata) life history. Project objectives were to determine adult lamprey escapement from Sherars Falls located at Rkm 70.4 and determine lamprey focal spawning areas, spawn timing and habitat through radio telemetry. A mark-recapture study and tribal creel was conducted to determine adult escapement. Lamprey were radio tagged and are currently being mobile, aerial and fixed site tracked to describe spawning. Adult lamprey were collected at Sherars Falls using a long-handled dip net from June-September 2007. The fate of lamprey collected at Sherars Falls was determined based on girth measurements. Fish measuring less than 10.5 cm received two markings for the mark-recapture estimation while those measuring 10.5 cm or greater were implanted with radio transmitters. Two-hundred and nine lamprey were marked during first event sampling, 2,501 lamprey inspected for marks and 64 recaptured during second event sampling. We estimate lamprey abundance to be 8,083 (6,352-10,279) with a relative precision of 19.8. Tribal harvest was 2,303 +/- 88. Escapement was estimated at 5,780 adult lamprey. Thirty-six lamprey received radio transmitters. Lamprey were transported upstream 6.3 Rkm for surgery, held to recover from anesthesia and released. Mobile tracking efforts started mid-July 2007 and are on-going. To date 35 of the 36 lamprey have been detected. Upon release, extensive ground-based tracking was conducted until fish became dormant in mid-October. Since, fixed site downloading and tracking have occurred weekly on the mainstem Deschutes River. Majority of lamprey (88%) are holding in the mainstem Deschutes River. Three lamprey moved upstream more than 70 Rkms into westside tributaries from August-December. Three moved approximately 18 Rkms downstream of the release site. Tracking will continue through the spawning season when redd characteristics will be measured and reported in the 2008-2009 annual report.

13 HYDRO ENERGY↗

Demonstration Assessment of Light-Emitting Diode (LED) Street Lighting Host Site: Lija Loop, Portland, Oregon

This report describes the process and results of a demonstration of solid-state lighting (SSL) technology in a residential street lighting application, under the U.S. Department of Energy GATEWAY Solid-State Lighting Technology Demonstration Program. In this project, eight 100W (nominal) high-pressure sodium cobra head fixtures were replaced with a like number of LED street light luminaires manufactured by Leotek, Inc. The Leotek product achieved an estimated payback in the Lija Loop installation of about 20 years for replacement scenarios and a much shorter 7.6 years for new installations. Much of the associated energy savings (55%) supporting these payback periods, however, were achieved by reducing average horizontal photopic illuminance a similar amount (53%). Examined from a different perspective, the measured performance suggests that the Leotek product is at approximate parity with the HPS cobra head in terms of average delivered photopic illumination for a given power consumption. HPS comprises the second most efficacious street lighting technology available, exceeded only by low pressure sodium (LPS). LPS technology is not considered suitable for most street lighting applications due to its monochromatic spectral output and poor color rendering ability; therefore, this LED product is performing at an efficiency level comparable to its primary competition in this application.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sodar - PNNL Scintec MFAS, Oregon Raceway Park - Reviewed Data

These data provide measurements of wind speed and direction up to 400 m above ground level (AGL) (max). The data are stored in two forms: ASCII and raw (binary). ASCII files contain averaged data (currently: 15 min time step and 10 m range gate). Raw files can be reprocessed with sodar software (APRun by Scintec) to produce ASCII files with different time and/or height averaging settings (highest resolution is approximately 90 sec and 10 m). NOTE: Wind direction is reported with respect to magnetic North.

17 WIND ENERGY↗

Geology of selected lava tubes in the Bend Area, Oregon

Longitudinal profiles representing 5872.5 m of mapped lava tubes and a photogeologic map relating lava tubes to surface geology, regional structure and topography are presented. Three sets of lava tubes were examined: (1) Arnold Lava Tube System (7km long) composed of collapsed and uncollapsed tube segments and lava ponds, (2) Horse Lava Tube System (11 km long) composed of parallel and anastomosing lava tube segments, and (3) miscellaneous lava tubes. Results of this study tend to confirm the layered lava hypothesis of Ollier and Brown (1965) for lava tube formation; however, there are probably several modes of formation for lava tubes in general. Arnold System is a single series of tubes apparently formed in a single basalt flow on a relatively steep gradient. The advancing flow in which the tubes formed was apparently temporarily halted, resulting in the formation of lava ponds which were inflated and later drained by the lava tube system. Horse System probably formed in multiple, interconnected flows. Pre-flow gradient appears to have been less than for Arnold System, and resulted in meandrous, multiple tube networks.

Greely, R.↗

Wind power research at Oregon State University

There have been two primary thrusts of the research effort to date, along with several supplementary ones. One primary area has been an investigation of the wind fields along coastal areas of the Pacific Northwest, not only at the shoreline but also for a number of miles inland and offshore as well. Estimates have been made of the influence of the wind turbulence as measured at coastal sites in modifying the predicted dependence of power generated on the cube of the wind speed. Wind flow patterns in the Columbia River valley have also been studied. The second primary thrust has been to substantially modify and improve an existing wind tunnel to permit the build up of a boundary layer in which various model studies will be conducted. One of the secondary studies involved estimating the cost of building an aerogenerator.

Hewson, E. W.↗