Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical amplifiers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Spectral dispersion of the linewidth enhancement factor and four wave mixing conversion efficiency of an InAs/GaAs multimode quantum dot laser

The spectral dependence of the linewidth enhancement factor (αH-factor) of a multimode InAs/GaAs quantum dot laser is analyzed. Amplified spontaneous and high-frequency modulation methods are used to experimentally retrieve the αH-factor of each longitudinal mode below and above the threshold. A dispersion of the αH-factor is unlocked across the entire optical spectrum, which is further illustrated in the context of four wave mixing experiments. The results show that the induced conversion efficiency is increased at lasing wavelengths where the linewidth enhancement is lower. These results highlight the importance of carefully monitoring the linewidth enhancement factor in quantum dot lasers especially for frequency combs and mode-locking applications in future optical communication systems.

Ding, Shihao (ORCID:0000000346416944)↗

Understanding the temperature and humidity dependence of the SiPM characteristics

A miniature version of the ICAL experiment at the India-based Neutrino Observatory, the mini-ICALis in operation at the IICHEP, Madurai. The commissioning work of a Cosmic Muon Veto detector (CMVD)on top of the mini-ICAL is continued using extruded plastic scintillators with embeddedWLS fibers and the SiPM as a photo-transducer. The CMVD is being built to study thefeasibility of a cosmic muon veto for a shallow-depth neutrino experiment. The SiPM is calibratedusing an ultrafast LED driver andthe same calibration techniques will be used during the data taking period with a simplified LED in thesame readout PCB. An experimental setup wasdesigned to characterise the SiPMs in a temperature controlled environment. The readout electronicsinvolves trans-impedance amplifiers and a voltage followers of combined gain 1.24 mV/$\mu$A and adigital storage oscilloscope for the data collection with a minimal distortion of SiPM signal.Various characteristics of the Hamamatsu SiPM (S13360-2050VE), e.g. signal shape, optically correlatedand uncorrelated noise, recovery time etc were studied as a function of $V_{ov}$, number of photoelectrons,the ambient temperature and the humidity. This paper will cover the details of those results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 40 Gbps Optical Transceiver for Particle Physics Experiments

We present the design and the test results of a quad-channel optical transceiver module (QTRx) possibly for future particle physics experiments. The transmitters of QTRx, each at 10 Gbps, are based on a Quad-channel VCSEL Diode array Driver (QLDD) and 1 x 4 VCSEL array. The receivers of QTRx, with data rates of 2.56 Gbps or 10 Gbps per channel, are based on a Quad-channel Trans-Impedance and limiting Amplifier (QTIA) and 1 x 4 photodiode array of GaAs or InGaAs. QTRx is 20 mm x 10 mm x 5 mm and couples to an MT fiber connector. Test results indicate that QTRx achieves the design goals with a power consumption of 124 mW per transmitter channel at 10 Gbps and 120 mW at 2.56 Gbps for the receiver channel with an on-chip charge pump. The sensitivities of QTIA are -17 dBm at 2.56 Gbps and -8 dBm at 10 Gbps, respectively. Further improvements with a gold-finger interface and a more compact optical lens are being designed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Readout Electronics of the Mu2e Electromagnetic Calorimeter

The Mu2e electromagnetic calorimeter has been designed to measure ~100 MeV electrons with energy resolution σE/E <10%, time resolution σt < 500ps and position resolution σx < 1cm. The detector is composed of 1348 un-doped CsI crystals coupled to two large area Silicon Photomultipliers (SiPMs). Each SiPM is connected to a Front End Electronics (FEE) chip which hosts the shaping amplifier and the high voltage linear regulator. A group of 20 FEE is controlled by one Mezzanine Board (MB) which transmits the amplified signals to one Digitizer ReAdout Controller board (DiRAC). The DiRAC samples the waveforms at 200 MHz with 12-bit ADCs, packs the data according to the Mu2e custom format and transmits them to the event builder through an optical transceiver. To limit the number of pass-through connectors and the length of the cables, the readout and digitization electronics is located inside the detector cryostat and close to the interaction target. The boards will have to sustain a neutron fluence of about 5x10 10 n/cm 2 @ 1 MeVeq (Si)/y and a Total Ionizing Dose of about 12 krad, while working into a 1T magnetic field and a vacuum of 10 (-4) Torr. This harsh operational environment has made the electronics design challenging and required an extended campaign of tests to select and qualify the employed electronic components. In this paper we report on the board architecture and design, on the qualification of the prototypes, as well as on the results of the first vertical slice test of the Mu2e calorimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parallel Broadband Femtosecond Reflection Spectroscopy at a Soft X-Ray Free-Electron Laser

X-ray absorption spectroscopy (XAS) and the directly linked X-ray reflectivity near absorption edges yield a wealth of specific information on the electronic structure around the resonantly addressed element. Observing the dynamic response of complex materials to optical excitations in pump–probe experiments requires high sensitivity to small changes in the spectra which in turn necessitates the brilliance of free electron laser (FEL) pulses. However, due to the fluctuating spectral content of pulses generated by self-amplified spontaneous emission (SASE), FEL experiments often struggle to reach the full sensitivity and time-resolution that FELs can in principle enable. Here, we implement a setup which solves two common challenges in this type of spectroscopy using FELs: First, we achieve a high spectral resolution by using a spectrometer downstream of the sample instead of a monochromator upstream of the sample. Thus, the full FEL bandwidth contributes to the measurement at the same time, and the FEL pulse duration is not elongated by a monochromator. Second, the FEL beam is divided into identical copies by a transmission grating beam splitter so that two spectra from separate spots on the sample (or from the sample and known reference) can be recorded in-parallel with the same spectrometer, enabling a spectrally resolved intensity normalization of pulse fluctuations in pump–probe scenarios. We analyze the capabilities of this setup around the oxygen K- and nickel L-edges recorded with third harmonic radiation of the free electron laser in Hamburg (FLASH), demonstrating the capability for pump–probe measurements with sensitivity to reflectivity changes on the per mill level.

36 MATERIALS SCIENCE↗

New Advances in Optical Stochastic Cooling

Recently, Optical Stochastic Cooling (OSC) became the first demonstrated method for ultra-high-bandwidth stochastic cooling. The initial experiments at Fermilab’s IOTA ring explored the essential physics of the method and demonstrated cooling, heating and manipulation of beams and single particles. Having been validated in practice, with continued development, OSC carries the potential for dramatic advances in the state-of-the-art performance and flexibility for beam cooling and control. The ongoing program at Fermilab is now focused on the development of an OSC system that includes high-gain optical amplification, which promises a two-order-of-magnitude increase in the strength of the OSC force. In this talk, we briefly review the results of the initial experimental campaign, describe the status of the conceptual and hardware designs for the amplified OSC system, report initial experimental results of our high-gain amplifier development, and explore near-term operational plans and use cases.

43 PARTICLE ACCELERATORS↗

Short Circuit Detection and Voltage Sense for High Voltage Ionization Tube Power Supplies

Fermilab's PIP-II upgrade requires new rack-mounted power supplies for Beam Loss Monitor (BLM) ionization tubes compatible with the microTCA 4.1 standard, supporting high-side current measurement for short circuit detection, voltage sense telemetry, and low-side current measurement for beam loss readout. This work presents the design and preliminary schematic of such a supply. A resistive current sensing approach was chosen over inductive, optical, and Hall-effect alternatives for its independence from cable length and component availability. A 500 mΩ inline shunt steps the 2 kV common mode voltage down to roughly 70 V, producing a ~27 μV pulse during a short, which is amplified 500x, compared against a 14-bit DAC threshold, and latched to drive a fault line. Voltage sense steps the 2 kV output down at a 1V/1000V ratio, buffers it with a low bias current amplifier, and digitizes it via a 24-bit ADC over SPI. Onboard power is regulated from 12 V down to isolated 5 V and 3.3 V rails, with capacitive isolation on FPGA communication lines. Lumped parameter models were developed for the ionization tube (0.327 nF, 20 to 200 GΩ dynamic resistance) and the RG-58 coaxial cable to support the design. Component selection is complete and a preliminary schematic has been drawn in Altium Designer, forming the foundation for future prototyping and validation.

Yu, Kellen [Cornell U.]↗

Real-Time Tracking of Carbon Dioxide Concentration Using an Optical Microsphere Resonator Sensor

Whispering gallery mode resonator sensors are nondisruptive optical sensors that can detect and monitor perturbations in a gaseous environment. Through its resonant properties of peak wavelength, amplitude, and quality factor (Q factor), changes in concentration can be quantified within seconds and monitored over days with great stability. In addition, the small footprint, low cost, and high sensitivity are ideal properties for a disposable sensor that can be utilized in extreme environments. Further, the large Q factor of the resonant cavity enables long interaction lengths and amplifies the effect of small changes in the background refractive index, which is detectable in picometer shifts of the resonance wavelength. However, this measurement is susceptible to changes in other environmental factors such as temperature, pressure, and humidity, which manifest on the picometer wavelength scale, reinforcing the need to decouple the variables. In this work, we compare the spectral response of different diameter resonators to carbon dioxide, nitrogen, and its mixtures, observing the spectral shifting and broadening of the cavity resonance near 1550 nm. In addition, the effect of environmental temperature on spectral shifting due to the thermo-optic effect is characterized and quantified. Lastly, the gas concentrations are changed in real time to showcase the tracking and recovery capabilities of the resonator sensor.

47 OTHER INSTRUMENTATION↗

System-on-chip approach microwave imaging reflectometer on DIII-D tokamak

System-on-chip millimeter wave integrated circuit technology is used on the two-dimensional millimeter-wave imaging reflectometer (MIR) upgrade for density fluctuation imaging on the DIII-D tokamak fusion plasma. Customized CMOS chips have been successfully developed for the transmitter module and receiver module array, covering the 55–75 GHz working band. The transmitter module has the capability of simultaneously launching eight tunable probe frequencies (>0 dBm output power each). The receiver enclosure contains 12 receiver modules in two vertical lines. The quasi-optical local oscillator coupling of previous MIR systems has been replaced with an internal active frequency multiplier chain for improved local oscillator power delivery and flexible installation in a narrow space together with improved shielding against electromagnetic interference. The 55–75 GHz low noise amplifier, used between the receiver antenna and the first-stage mixer, significantly improves module sensitivity and suppresses electronics noise. The receiver module has a 20 dB gain improvement compared with the mini-lens approach and better than –75 dBm sensitivity, and its electronics noise temperature has been reduced from 55 000 K down to 11 200 K. Further, the V-band MIR system is developed for co-located multi-field investigation of MHD-scale fluctuations in the pedestal region with W-band electron cyclotron emission imaging on DIII-D tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PV encapsulant formulations and stress test conditions influence dominant degradation mechanisms

Polyethylene-based poly(ethylene-co-vinyl acetate) (EVA), polyolefin elastomer (POE), and thermoplastic polyolefin (TPO) are common polymer candidates for photovoltaic (PV) module encapsulants. The choice of encapsulant must be carefully considered in novel module designs, such as bifacial glass/glass laminates, to limit performance degradation through loss of optical transmittance, mechanical integrity, and corrosion - as well as potential-induced degradation. Encapsulant quality and resilience against environmental stressors are readily influenced by the additives in the encapsulant formulation. Here, we show that, the changes in optical transmittance after UV aging result from the discoloration caused by interactions between additives, and optical scattering from changes in the polymer crystal structure. We observed competing cross-linking and chain scission mechanisms, with their kinetics influenced by the presence of oxygen and elevated temperatures. Increasing chamber temperatures from 55 °C to 85 °C during the UV stress test amplified encapsulant discoloration and promoted polymer cross-linking, causing severe, irreversible damage that remains to be proven field relevant. Damp heat aging was found to be insufficient to produce significant encapsulant degradation; however, combining stress tests sequentially allowed detection of further degradation beyond the limitations of the damp heat test alone. Appropriate degradation screening methods are necessary to uncover potential encapsulant weaknesses.

14 SOLAR ENERGY↗

Generation of gamma radiation by a subterawatt ultrashort laser pulse: optimisation of preplasma and pulse duration

We report an experimental and numerical study of the acceleration of electrons in a plasma interacting with a subterawatt laser pulse (intensity of ∼3 × 10{sup 18} W cm{sup −2} at a pulse duration of 50 fs). A preplasma layer on the surface of a molybdenum target is formed by an additional laser pulse with a duration of 8 ns and an intensity of ∼2 × 10{sup 12} W cm{sup −2}. It is shown that an increase in the laser pulse duration to 1700 fs at a constant energy (and a proportional decrease in intensity) leads to an increase in the yield of bremsstrahlung γ-radiation by more than an order of magnitude when the nanosecond pulse is ahead of the femtosecond one by 15 − 25 ns. Interferometry data and results of diagnostics of optical and γ-radiation of a plasma demonstrate that the collisional ionisation of atoms by electrons oscillating in the field of such a laser pulse plays an essential role in the formation of electron density profile. The sensitivity of the described effect to the level of amplified spontaneous emission is determined, despite the nanosecond pulse impact. Numerical simulations show that at a large pulse duration, the acceleration of electrons is stipulated by the beaking of plasma waves excited during stimulated Raman scattering of laser radiation. (paper)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear interferometer systems and methods

Nonlinear interferometers include a nonlinear optical medium that is situated to produce a conjugate optical beam in response to a pump beam and a probe beam. The pump, probe, and conjugate beams propagate displaced from each other along a common optical path. One of the beams is selectively phase shifted, and the beams are then returned to the nonlinear medium, with the selectively phase shift beam phase shifted again. The nonlinear medium provides phase sensitive gain to at least one of the probe or conjugate beams, and the amplified beam is detected to provide an estimate of the phase shift.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Millimeter-Thick Liquid Crystalline Elastomer Actuators Prepared by-Surface-Enforced Alignment

Here, liquid crystalline elastomers (LCE) are thermally cyclable, compliant actuators with compelling mechanical properties. The large and programmable deformation of LCE has led to numerous functional examinations spanning optics, medical devices, and robotics. A well-established method to prepare complex LCE actuators is to utilize surface-enforced photoalignment. Herein, a facile and scalable approach is reported to circumvent the physical limits of surface-enforced alignment (e.g., samples that are 50 µm or less) to amplify the achievable force output in LCE. Applying an approach termed direct layering, the thermomechanical response of LCE elements prepared with +1 disclination patterns in a range of compositions and thicknesses is contrasted. The design and preparation of +1 disclination patterns and arrays is explored to assess the contribution of sample geometry and overlap to deformation and force output. The methodology detailed in this contribution allows for the preparation of elements ≈1 mm in thickness that are capable of actuating large objects. Furthermore, the fabrication of these elements uniquely enables the realization of mechanical instabilities to hasten the actuation rate in response to thermal change and to enable leaping.

36 MATERIALS SCIENCE↗

Generation of 3.3-mJ, 2.45-µm, sub-2-cycle laser pulses via hollow-core fiber pulse compression

We demonstrate nonlinear compression of mid-infrared pulses from a Cr:ZnSe chirped-pulse amplifier using a gas-filled stretched hollow-core fiber followed by bulk-material compression. Starting from 90 fs, 2.45 µm pulses with 5.3 mJ energy, spectral broadening in the gas-filled capillary combined with optimized dispersion management enables compression to 15 fs, less than two optical cycles at 2.45 µm, with 3.3 mJ pulse energy, corresponding to a peak power of approximately 0.12 TW. The simplicity of the approach, based on a single hollow-core fiber stage and bulk dispersion compensation, makes it scalable to higher energies and establishes a robust route to mid-infrared drivers for high harmonic generation and attosecond applications.

Britton, Mathew [SLAC National Accelerator Laborat↗

Transition Metal Dichalcogenides: Making Atomic‐Level Magnetism Tunable with Light at Room Temperature

Abstract The capacity to manipulate magnetization in 2D dilute magnetic semiconductors (2D‐DMSs) using light, specifically in magnetically doped transition metal dichalcogenide (TMD) monolayers ( M ‐doped TX 2 , where M = V, Fe, and Cr; T = W, Mo; X = S, Se, and Te), may lead to innovative applications in spintronics, spin‐caloritronics, valleytronics, and quantum computation. This Perspective paper explores the mediation of magnetization by light under ambient conditions in 2D‐TMD DMSs and heterostructures. By combining magneto‐LC resonance (MLCR) experiments with density functional theory (DFT) calculations, we show that the magnetization can be enhanced using light in V‐doped TMD monolayers (e.g., V‐WS 2 , V‐WSe 2 ). This phenomenon is attributed to excess holes in the conduction and valence bands, and carriers trapped in magnetic doping states, mediating the magnetization of the semiconducting layer. In 2D‐TMD heterostructures (VSe 2 /WS 2 , VSe 2 /MoS 2 ), the significance of proximity, charge‐transfer, and confinement effects in amplifying light‐mediated magnetism is demonstrated. We attributed this to photon absorption at the TMD layer that generates electron–hole pairs mediating the magnetization of the heterostructure. These findings will encourage further research in the field of 2D magnetism and establish a novel design of 2D‐TMDs and heterostructures with optically tunable magnetic functionalities, paving the way for next‐generation magneto‐optic nanodevices.

36 MATERIALS SCIENCE↗

Intersubband transitions in nonpolar and semipolar III-nitrides: Materials, devices, and applications

In the last two decades, the third-generation wide bandgap semiconductor III-nitrides have revolutionized a myriad of electronic and photonic devices and applications, including power electronics, extreme-environment electronics, RF amplifiers, and optoelectronics such as light-emitting diodes and laser diodes. Recently, III-nitride heterostructures (e.g., AlGaN/GaN) based intersubband transition (ISBT) has garnered considerable research interest for infrared (IR), terahertz (THz), and ultrafast optoelectronics (e.g., photodetectors and quantum cascade lasers) due to its large conduction band offset, large optical phonon energy, and promising room-temperature operation. This paper presents a comprehensive review on the recent progress and challenges of III-nitrides based ISBT from the perspectives of materials, structures, devices, and applications, with a focus on nonpolar and semipolar III-nitrides. Various device structures have been demonstrated for III-nitrides based ISBT, including quantum wells, dots, and wires, among which AlGaN/GaN quantum wells are the most widely used. The effects of device parameters, crystal orientations, and doping on the ISBT properties of AlGaN/GaN quantum wells are discussed. Although the room-temperature operation is still elusive, theoretical and experimental studies show that nonpolar and semipolar III-nitrides based ISBT exhibits tunable ISBT wavelength from far-IR to THz spectral range with higher efficiency compared with polar c-plane ISBT. This review can serve as a gateway to and an important reference for the recent progress and challenges of III-nitrides based ISBT and its potential applications in sensing, communication, ultrafast optoelectronics, and integrated photonics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗