Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Jones's matrix representation of optical instruments. II - Fourier interferometers /spectrometers and spectropolarimeters/.

Our method of matrix synthesis of optical components and instruments is applied to the derivation of Jones's matrices appropriate for Fourier interferometers (spectrometers and spectropolarimeters). These matrices are obtained for both the source beam and the detector beam. In the course of synthesis, Jones's matrices of the various reflectors (plane mirrors; retroreflectors: roofed mirror, trihedral and prism cube corner, cat's eye) used by these interferometers are also obtained.

Fymat, A. L.↗

Wide angle Michelson Doppler imaging interferometer

The optical system, stepping control, phase and modulation depth, array detector, and directions sensor are described for a specialized type of Michelson interferometer which works at sufficiently high resolution to measure the line widths and Doppler shifts of naturally occurring atmospheric emissions. With its imaging capability, the instrument can potentially supply this data independently for each element of the 100 x 100 detector array. The experiment seeks: (1) to obtain vertical profiles of atmospheric winds and temperatures as functions of latitude by observing near the limb; (2) to acquire exploratory wind and temperature data on smaller scale structures in airglow irregularities and in auroral forms; and (3) to collaborate with other Spacelab experiments, such as barium cloud releases, in providing wind and temperature data.

Shepherd, G. G.↗

Modular removable precision mechanism for alignment of an FUV spatial heterodyne interferometer

Spaceflight optical instruments have two conflicting requirements. They need to be both rigid and lightweight. In addition, for interferometric far ultraviolet spectrometers, the requirements for precision positioning are more severe than for conventional spectrometers. To meet the challenge of lightweight optical instruments, a modular adjustment mechanism was developed to position two orthogonal axes of a universal three-axis gimbal support system with a positioning accuracy on the order of 10 arc seconds. The mechanism was designed as a self-contained assembly which can be removed after final alignment of a spacebound optical instrument to reduce its in-flight mass. To demonstrate the concept, a number of these assemblies were made and mounted on two of the positioning axes of a far ultraviolet spatial heterodyne interferometer. A shaft clamp was used on each positioning axis to retain the adjusted position. This paper describes the design of the mechanism and presents optical test results.

Tom, James L.↗

Optical fiber waveguide sagnac interferometer. Phase 1: Multiturn one meter diameter, single mode

A rotating ring interferometer was constructed using a 100 meters of single mode optical fiber wound on a crystal cylinder. A 20 inch diameter fiber interferometer gyroscope was built and its sensitivity was evaluated. Major noise sources were identified and improvements for the next phase of development were determined. The accuracy of .01 of a fringe can be improved to .0001 by the removal of the noise source.

Vali, V.↗

Interferometer for Measuring Acoustic Signals

Optical-fiber interferometer measures wave amplitude without contacting specimen surface. System contains remote detector head. Head includes beam splitter that divides input beam and recombines output beams, while spatial filter filters interference pattern at beam-splitter output; and lens focuses this on detector. Beams focused on specimen surface to record acoustic signals.

Claus, R. O.↗

Gas Sensors Based on Single-Arm Waveguide Interferometers

Various optical technologies can be implemented in chemical sensing. Sensitive, rugged, and compact systems will be more likely built using interferometric waveguide sensors. Currently existing sensors comprise dual-arm systems with external reference arm, dual-arm devices with internal reference arm such as integrated Mach-Zehnder interferometer, and single-arm systems which employ the interference between different waveguide modes. These latter ones are the most compact and rugged but still sensitive enough to monitor volatile pollutants such as NH3 coming out of industrial refrigerators and fertilizer plants and stocks, NO, NO2, SO2, emitted by industrial burning processes. Single-arm devices in planar waveguide configuration most frequently use two orthogonally polarized modes TE (sub i) and TM (sub i) of the same order i. Sensing effect is based on the difference in propagation conditions for the modes caused by the environment. However, dual-mode single-order interferometers still have relatively low sensitivity with respect to the environment related changes in the waveguide core because of small difference between propagation constants of TE (sub i) and TM (sub i) modes of the same order. Substantial sensitivity improvement without significant complication can be achieved for planar waveguide interferometers using modes of different orders with much greater difference between propagation constants.

Sarkisov, Sergey↗

Spatial interferometry for white light processing: The coherence interferometer

An optical systems design approach for a parallel optical processor that has an information throughput capacity in excess of one petabit per second is discussed. This system enables predetection processing of white light, passively illuminated scenes. Integrated with a programmable Van der Lugt filter, this system is an effective data compression method. A program to implement this parallel optical processing by interferometry system is discussed.

Breckinridge, J. B.↗

Optical diameters of stars measured with the Mt. Wilson Mark III interferometer

Reliable stellar angular diameters can now be determined using the Mark III Optical Interferometer located on Mt. Wilson, California. The Mark III is a Michelson Interferometer capable of measuring the interferometric fringe visibility for stars using interferometer baselines varying from 3 to 31.5 meters in length. Angular diameters measured with the Mark III Optical Interferometer are presented for 12 stars at wavelengths of 450 and 800 nm.

Simon, R. S.↗

Interferometer for Measuring Displacement to Within 20 pm

An optical heterodyne interferometer that can be used to measure linear displacements with an error <=20 pm has been developed. The remarkable accuracy of this interferometer is achieved through a design that includes (1) a wavefront split that reduces (relative to amplitude splits used in other interferometers) self interference and (2) a common-optical-path configuration that affords common-mode cancellation of the interference effects of thermal-expansion changes in optical-path lengths. The most popular method of displacement- measuring interferometry involves two beams, the polarizations of which are meant to be kept orthogonal upstream of the final interference location, where the difference between the phases of the two beams is measured. Polarization leakages (deviations from the desired perfect orthogonality) contaminate the phase measurement with periodic nonlinear errors. In commercial interferometers, these phase-measurement errors result in displacement errors in the approximate range of 1 to 10 nm. Moreover, because prior interferometers lack compensation for thermal-expansion changes in optical-path lengths, they are subject to additional displacement errors characterized by a temperature sensitivity of about 100 nm/K. Because the present interferometer does not utilize polarization in the separation and combination of the two interfering beams and because of the common-mode cancellation of thermal-expansion effects, the periodic nonlinear errors and the sensitivity to temperature changes are much smaller than in other interferometers

Zhao, Feng↗

Rigid lightweight optical bench for a spaceborne FUV spatial heterodyne interferometer

Requirements for spaceflight optical instruments usually dictate that for the structures be rigid, lightweight, and thermally stable. In addition, for interferometric far ultraviolet (FUV) spectrometers, the requirements for torsional deflection are more severe than with conventional spectrometers. To meet the challenge for rigid and lightweight optical instruments, this paper explores the design of a high-stiffness structure for the support of an FUV spatial heterodyne interferometer where the torsional deflection of the instrument is on the order of 10 arc seconds. The structure is based on use of a thin, hollow section beam with weight-relieving between optical elements. The design also uses a modular and self-contained positioning mechanism that is removed after final optical alignment. Several specific material properties are presented as criteria for material selection. The parameters which affect the particular design requirements are identified with respect to the desired material properties and physical design features. Although large thin sections are susceptible to thermal gradients, this could be minimized by a trade-off for weight, where adequate margin exists. This paper describes the preliminary design for the structure and presents an analysis to verify compliance with the requirements.

Tom, James L.↗

Double-exposure holographic interferometer

Expensive optical-grade components in holographic interferometer are replaced with plastic test section and large-aperture spherical mirror to reduce distortions introduced by imperfections and cylindrical shape of plastic. Instrument is used for shock-tube gas density studies and is adaptable to wind-tunnel studies of vehicle windshields and other testing.

Livingston, F. R.↗

A fiber-coupled heterodyne interferometric displacement sensor

Space-based interferometers and large segmented reflectors will require precision metrology with nanometer accuracy for active control systems. This paper summarizes an experimental study of an optical heterodyne interferometer with resolution of about 3 nm. Optical signals are carried to and from the interferometer by optical fibers to avoid thermally loading the reflector panels. Heterodyne detection provides far greater precision than does traditional interferometry.

Nerheim, Noble↗

Wide Angle Michelson Doppler Imaging Interferometer (WAMDII)

The wide angle Michelson Doppler imaging interferometer (WAMDII) is a specialized type of optical Michelson interferometer working at sufficiently long path difference to measure Doppler shifts and to infer Doppler line widths of naturally occurring upper atmospheric Gaussian line emissions. The instrument is intended to measure vertical profiles of atmospheric winds and temperatures within the altitude range of 85 km to 300 km. The WAMDII consists of a Michelson interferometer followed by a camera lens and an 85 x 106 charge coupled device photodiode array. Narrow band filters in a filter wheel are used to isolate individual line emissions and the lens forms an image of the emitting region on the charge coupled device array.

Roberts, W. T.↗

Wide Angle Michelson Doppler Imaging Interferometer (WAMDII)

The wide angle Michelson Doppler imaging interferometer (WAMDII) is a specialized type of optical Michelson interferometer working at sufficiently long path difference to measure Doppler shifts and to infer Doppler line widths of naturally occurring upper atmospheric Gaussian line emissions. The instrument is intended to measure vertical profiles of atmospheric winds and temperatures within the altitude range of 85 km to 300 km. The WAMDII consists of a Michelson interferometer followed by a camera lens and an 85 x 106 charge coupled device photodiode array. Narrow band filters in a filter wheel are used to isolate individual line emissions and the lens forms an image of the emitting region on the charge coupled device array.

Roberts, B.↗

Fabry-Perot interferometers as narrow band optical filters.

We have constructed solid Fabry-Perot narrow-band filters that can be used in systems having one arc second or better resolution. Our filters operate at H-alpha, have a three-inch aperture, and typical transmission of 70 per cent. However, the same technology can be applied to construction of filters as narrow as 0.05 A at any wavelength from 4200 to 11000 A.

Title, A. M.↗

Multimode fiber-optic broad spectral band interferometer

An interferometric technique for observing white light fringes on a mode-by-mode basis in long lengths of few-mode fiber is described. Each mode can be used as a separate channel with negligible cross talk from other modes because of the highly localized nature of interference. The spatial-mode separation technique makes it possible to observe the interference fringes without loss of visibility caused by multimode overlap effects. The high-contrast, broadband fringes observed in the multimode interference experiments indicate that a multimode fiber is capable of maintaining the coherence of injected light well beyond the point where intermodal path differences exceed the temporal coherence length.

Shaklan, S.↗