At least 199 records · Page 11

Nuclear Computational Resource Center Progress and Status Report

The Nuclear Computational Resource Center (NCRC) at Idaho National Laboratory (INL), supported by the United States Department of Energy Office of Nuclear Energy (DOE-NE), provides access to supercomputer systems and protected software in support of nuclear energy research and development. The NCRC vision recognizes the central role modeling and simulation plays in nuclear energy innovation as well as ensuring the safe, secure, and efficient operations of existing nuclear energy systems. To accomplish this vision, the NCRC supports processes and systems which provide access to computational tools, supercomputing systems, and training in support of nuclear energy innovation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Review of Enabling Technologies to Facilitate Secure Compute Customization

High performance computing environments are often used for a wide variety of workloads ranging from simulation, data transformation and analysis, and complex workflows to name just a few. These systems may process data for a variety of users, often requiring strong separation between job allocations. There are many challenges to establishing these secure enclaves within the shared infrastructure of high-performance computing (HPC) environments. The isolation mechanisms in the system software are the basic building blocks for enabling secure compute enclaves. There are a variety of approaches and the focus of this report is to review the different virtualization technologies that facilitate the creation of secure compute enclaves. The report reviews current operating system (OS) protection mechanisms and modern virtualization technologies to better understand the performance/isolation properties. We also examine the feasibility of running ``virtualized'' computing resources as non-privileged users, and providing controlled administrative permissions for standard users running within a virtualized context. Our examination includes technologies such as Linux containers (LXC [32], Docker [15]) and full virtualization (KVM [26], Xen [5]). We categorize these different approaches to virtualization into two broad groups: OS-level virtualization and system-level virtualization. The OS-level virtualization uses containers to allow a single OS kernel to be partitioned to create Virtual Environments (VE), e.g., LXC. The resources within the host's kernel are only virtualized in the sense of separate namespaces. In contrast, system-level virtualization uses hypervisors to manage multiple OS kernels and virtualize the physical resources (hardware) to create Virtual Machines (VM), e.g., Xen, KVM. This terminology of VE and VM, detailed in Section 2, is used throughout the report to distinguish between the two different approaches to providing virtualized execution environments. As part of our technology review we analyzed several current virtualization solutions to assess their vulnerabilities. This included a review of common vulnerabilities and exposures (CVEs) for Xen, KVM, LXC and Docker to gauge their susceptibility to different attacks. The complete details are provided in Section 5 on page 33. Based on this review we concluded that system-level virtualization solutions have many more vulnerabilities than OS level virtualization solutions. As such, security mechanisms like sVirt (Section 3.3) should be considered when using system-level virtualization solutions in order to protect the host against exploits. The majority of vulnerabilities related to KVM, LXC, and Docker are in specific regions of the system. Therefore, future "zero day attacks" are likely to be in the same regions, which suggests that protecting these areas can simplify the protection of the host and maintain the isolation between users. The evaluations of virtualization technologies done thus far are discussed in Section 4. This includes experiments with 'user' namespaces in VEs, which provides the ability to isolate user privileges and allow a user to run with different UIDs within the container while mapping them to non-privileged UIDs in the host. We have identified Linux namespaces as a promising mechanism to isolate shared resources, while maintaining good performance. In Section 4.1 we describe our tests with LXC as a non-root user and leveraging namespaces to control UID/GID mappings and support controlled sharing of parallel file-systems. We highlight several of these namespace capabilities in Section 6.2.3. The other evaluations that were performed during this initial phase of work provide baseline performance data for comparing VEs and VMs to purely native execution. In Section 4.2 we performed tests using the High-Performance Computing Conjugate Gradient (HPCCG) benchmark to establish baseline performance for a scientific application when run on the Native (host) machine in contrast with execution under Docker and KVM. Our tests verified prior studies showing roughly 2-4% overheads in application execution time & MFlops when running in hypervisor-base environments (VMs) as compared to near native performance with VEs. For more details, see Figures 4.5 (page 28), 4.6 (page 28), and 4.7 (page 29). Additionally, in Section 4.3 we include network measurements for TCP bandwidth performance over the 10GigE interface in our testbed. The Native and Docker based tests achieved >= ~9Gbits/sec, while the KVM configuration only achieved 2.5Gbits/sec (Table 4.6 on page 32). This may be a configuration issue with our KVM installation, and is a point for further testing as we refine the network settings in the testbed. The initial network tests were done using a bridged networking configuration. The report outline is as follows: - Section 1 introduces the report and clarifies the scope of the proj...

Aderholdt, Ferrol↗

Module-OT: A Hardware Security Module for Operational Technology

Increased penetration levels of renewable energy and other types of distributed energy resources (DERs) on the modern electric grid-combined with technological advancements for electric system monitoring and control-introduce new cyberattack vectors and increase the cyberattack surface of energy systems. According to the IEEE Std. 1547-2018, DERs must use Modbus, Distributed Network Protocol 3 (DNP3), or Smart Energy Profile 2.0 (SEP2) as their communication protocol. Previous research identified several vulnerabilities and security breaches in each one of these communication protocols; despite this, existing standards for DERs do not recommend cybersecurity measures. In order to reduce vulnerabilities in power distribution systems, this paper presents a novel open-source hardware security module that improves both information and operational security to better protect data and communications on the distribution grid. The security hardware is called “module for operational technology,” or simply Module-OT, and it has been validated and tested in an emulated distribution system application. Module-OT is integrated within a communication system in the transport layer of the Open Systems Interconnection (OSI) model. It improves system security through encryption, authentication, authorization, certificate management, and user access control. The main advancement of Module-OT is the addition of hardware cryptographic acceleration that improves the overall communication performance in terms of end-to-end latency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Computer security approach for Rolls-Royce spinline{sup R} safety platform - 227

The number of digital assets at commercial nuclear power plants is significant and will likely continue to increase with time. As a consequence, these plants have become potential targets for cyber-attacks. Around the world, nuclear safety authorities and national Computer and Information Security Agencies are implementing stricter regulations and inspections for critical systems in nuclear plants. There is a particular focus on instrumentation and control systems as they implement key nuclear safety functions. Rolls-Royce follows a strict computer and information security program based on general and nuclear specific norms, Rolls-Royce group processes, and proven technologies. The Spinline digital safety platform has been designed specifically for nuclear applications and features a secure development and operational environment that provides barriers against unauthorized modifications and implements design requirements promoting integrity and reliability during operation and maintenance. The Rolls-Royce secure development environment provides layers of protection utilizing physical and environmental security, human resource security, and information technology systems access control. The Spinline platform strengthens security functions by providing protection against unauthorized, unintended, and unsafe modifications to the system. The Spinline platform has design features promote integrity and reliability during operation and maintenance in the event of inadvertent operator actions or undesirable behavior of connected equipment. The Spinline technology and these computer security processes are based in a wide spectrum of international standards that were accepted as providing a secure development and operating environment by the United States Nuclear Regulatory Commission in 2014. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Retro-Future

A system for processing network packet capture streams, extracting metadata and generating flow records (via Argus). The system can be used by network security operators and analysts to enable forensic investigations for network security events.

Ferrell, Paul↗

Retro-Future

A system for processing network packet capture streams, extracting metadata and generating flow records (via Argus). The system can be used by network security operators and analysts to enable forensic investigations for network security events.

Ferrell, Paul↗

A novel priority selection system for nuclear power plant - 287

The priority selection system is an important component of security level instrument control platform for nuclear power plant, the main function of which is priority processing the manual or automatic command with various security levels and driving engineering safety features and field devices, such as pump and valve. Its stability and safety plays a crucial role in the operation of the power plant. The main objective of the present paper is to describe the new nuclear power plant-oriented priority selection system, which is developed independently by China Nuclear Control System Engineering Company. In this system, the control commands from 1E DCS, ECP and DAS systems are transmitted via hardwire, while those from NC DCS are transmitted by field-bus. The control commands experience priority output to control the field actuators. Meanwhile, in order to control key field devices when failure of the instrument control systems occurs, the issuing interface for native instructions with permissions setting is also offered. The whole system provides collection-feedback functions for field devices, high coverage self-diagnostic functions and periodic test functions for safety systems. Moreover, the feedback information of field devices, the results of self-diagnosis and periodic test will be submitted to DCS of nuclear power plant. In addition, the core part of priority selection system, namely priority selection module, is obtained by pure FPGA technology, which is different from DCS systems and could avoid common cause failure of software effectively. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Cybersecurity Threat Profile for a Connected Lighting System

In anticipation of improved energy performance and cost savings, cities and building owners are increasingly considering “smart lighting initiatives” that aim to convert their collection of simple luminaires (i.e., lighting fixtures) into an intelligent connected lighting system (CLS) capable of remotely monitoring energy consumption and fault conditions, and possibly implementing adaptive lighting schemes. The U.S. Department of Energy (DOE) has set an national goal of tripling the energy efficiency and demand flexibility of the buildings sector by 2030, relative to 2020 levels 1. It is forecast that connected lighting systems can contribute to that goal by delivering 125 TWh of annual energy savings by 2035 2, equivalent to the annual output of 50 typical (500 MW) power plants. However, these energy savings and the DOE goal are put at significant risk if connected technologies are not adopted due to real or perceived cybersecurity concerns. Connected IoT devices such as these have historically been rife with vulnerabilities which sometimes put security considerations secondary to functionality and operability. What are the cybersecurity threats that will impact these systems, as formerly banal luminaires transition into intelligent connected devices that collect information about themselves, their surrounding environment, and possibly us? In this paper we analyze a threat profile performed on a fault-detection use case for streetlights. A threat profile establishes security requirements, justifies security measures, yields actionable controls, and effectively communicates risk to stakeholders. This effort provides critical information for making threat-based decisions to increase security at a reasonable cost, and can effectively be used by development teams, software architects, and managers to make cybersecurity a part of their ongoing culture of awareness, training, and prevention. This leads to more secure systems and better-understood security. On-premise, cloud, and hybrid architectures with different authentication mechanisms were modeled and later categorized using the Microsoft STRIDE framework. An analysis of the recommended controls for each threat was performed to determine which controls could and should be put in place by manufacturers or third-party suppliers, and which controls need to be left up the end-user to implement. Fifty-seven threats were identified. Among our key findings: (1) 65% (37/57) of the threats did not involve the luminaires, but rather the other components needed to communicate with and manage them; (2) 63% (36/57) of the threats could have been mitigated through manufacturer-implemented defensive techniques or “controls”; and (3) 23% (13/57) of the threats were dependent on the network configuration. Recommendations based on the results of this work are made to key stakeholder groups. Notably, lighting technology developers are advised to address all threats that can be reasonably controlled with baked-in technology solutions (e.g., encryption or authentication controls), and employ some form of secure supply chain management and tracking where other parts (e.g., sensors, microprocessors) of a luminaire must also be built and manufactured with the proper security controls in place. Developers should also review threats involving assets not developed in-house to understand how connectivity with other devices will affect their product during system operation and determine if a compensating control for a defense-in-depth strategy will be needed. Finally, those interested in deploying CLS should compare the differences between cloud and on-premise models to determine which is more suitable for their needs and the abilities of their security team.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Common Operating Picture: UAV Security Study

This initial communication security study is a top-level assessment of basic security issues related to the operation of Unmanned Aerial Vehicles (UAVs) in the National Airspace System (NAS). Security considerations will include information relating to the use of International Civil Aviation Organization (ICAO) Aeronautical Telecommunications Network (ATN) protocols and applications identifying their maturity, as well as the use of IPV4 and a version of mobile IPV6. The purpose of this assessment is to provide an initial analysis of the security implications of introducing UAVs into the NAS.

Source record↗

Service-Based, Segmented, 5G Network-Based Architecture for Securing Distributed Energy Resources: Preprint

As the number of connected devices in the energy grid increase exponentially, so too are the cybersecurity risks. With the development of modern communications standards such as 5G and beyond the extent to which devices will continue to connect will continue to increase exponentially along with the inherent risks. However, 5G also includes features to help address cybersecurity concerns and therefore helping to mitigate many of these risks. This paper proposes a new service-based network architecture implementing network-slicing capabilities for connected systems and devices to improve performance, availability, security, and reliability of the grid devices and services. This paper considers the quality of service requirements and criticality of services needed for securely monitoring, operating, and securing Distributed Energy Resource (DER) devices. From developed use cases, network slicing is implemented based on these requirements and resource allocations. This work then highlights examples of how slicing can help prevent standard existing attack methods such as a denial-of-service or similar attack which limits resource availability and network bandwidth to the service and thus limiting its ability to affect other services by misbehaving. The designed network architecture use case will be further tested on a local virtualized testbed to verify secure operation and availability of services. Using hardware-in-the-loop devices and systems on this local testbed, this fully segmented, secure network may be realized and evaluated. Finally, this paper presents the results of this testing.

5G↗

Impact Analysis of Data Integrity Attacks on FACTS-based Wide-Area Voltage Control System

Energy management system (EMS) consists of several wide-area control applications that serve as a backbone for security, stability, and reliability of the power system. Wide-area voltage control system (WAVCS), one of the critical wide-area applications, operates in coordination with local Flexible AC Transmission System (FACTS) devices to provide voltage security and optimal management of active and reactive power resources. Since the WAVCS relies on wide-area communication and data sharing devices, possible cybersecurity vulnerabilities have to be addressed to ensure the closed-loop operation of WAVCS. In this paper, we present a methodology for performing an impact analysis of cyber-attacks in WAVCS cybersecurity. In particular, different types of data integrity attacks, such as malicious tripping, fault replay, and signal altering attacks, are considered, and detailed impact analysis is conducted in a testbed environment using the Kundur's four machine two-area system. For performing an impact analysis, the transient voltage stability of the sensitive bus voltage is studied, followed by the quantitative assessment and severity ranking using the voltage profile index. Our experimental evaluation reveals that the data integrity attacks on control signals exhibit a higher attack severity than on the measurement signals. Further, the severity of these attacks varies with nature (static or dynamic), location, and types of attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Supercapacitor to Provide Ancillary Services: Preprint

Supercapacitor technology has reached a level of maturity as a viable energy storage option available to support a modern electric power system grid; however, its application is still limited because of its energy capacity and the cost of the commercial product. In this paper, we demonstrate transient models of supercapacitor energy storage plants operating in coordination with run-of-the-river (ROR), doubly-fed induction generator hydropower plants (HPP) using a system control concept and architecture developed. A detailed transient model of a supercapacitor energy storage device is coupled with the grid via a three-phase inverter/rectifier and bidirectional DC-DC converter. In addition, we use a version of a 14-bus IEEE test case that includes the models of the supercapacitor energy storage device, ROR HPPs, and synchronous condensers that use the rotating synchronous generators of retired coal-powered plants. The purpose of the synchronous condensers is to enhance the system stability by providing voltage and reactive power control, provide power system oscillations damping, and maintain system inertia at secure levels. The control layer provides coordinated, decentralized operation of distributed ROR HPPs and energy storage as aggregate support to power system operations.

25 ENERGY STORAGE↗

Cybersecurity Risk Profiles for Distributed Energy Resource Management Systems

Managing the digitalization of increasingly diversity energy resources is a complex challenge for energy systems planners and managers. As the penetration of solar photovoltaics (PV) and other distributed renewable energy resources (DERs) expands, distributed energy resource management systems (DERMS) will play an increasingly important role in managing, monitoring, and controlling DERs as electric systems before more distributed, interconnected, and networked. However, the cybersecurity implications of DERMS deployments are not well understood today. A lack of understanding around the cybersecurity implications of DERMS deployments and variability in the security posture of DERMS vendors, owners, and operators could introduce new security risks to evolving electric power systems. This paper describes cybersecurity attack scenarios on DERMS, identifies related cybersecurity standards and guidelines, reviews the security features of state-of-the-art DERMS solutions, and offers cybersecurity guidance for DERMS vendors, owners, and operators to protect DERMS' unique capabilities. Standardizing cybersecurity requirements for DERMS could help improve the security of DERMS integrations and improve innovations that are more secure by design. The cybersecurity guidance found in this paper is intended to offer a unified approach and lay the foundation for future standardization of DERMS cybersecurity to reduce risk to the solar industry and other renewable energy stakeholders when integrating these technologies with electric power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber Threat Assessment Methodology for Autonomous and Remote Operations for Advanced Reactors (Conference Presentation)

The next generation of Advanced Reactors include planned capabilities for both Autonomous (operating without human interaction for a set period-of-time) and Remote (operating with human interaction from a separate physical location) Operations. Existing Nuclear Reactor architectures include a set of safety and security constraints tightly coupled with personnel policies and procedures. As Advanced Reactors are fielded with these new Autonomous and Remote operational capabilities, the architectures and associated infrastructure services and components will perceivably expand the overall attack surface and risk calculations with regards to safe and secure operations. This paper is part of an FY21 work program focused on ensuring Advanced Reactor designs are informed with threat-based guidance on design and operation of Secure Architectures with a specific focus on the deployment of Autonomous Systems in support of Advanced Reactor Operations. The next phase of this research program is to complement produce a methodology for assessment of the cyber threat against these architectures as well as a catalogue of Use Cases to support the Advanced Reactor community in their implementation of Autonomous and Remote Operations.

97 MATHEMATICS AND COMPUTING↗

Advanced modeling of $\mathrm{DER}$s and $\mathrm{UPFC}$ devices with Sparse Tableau Formulation for $\mathrm{ACOPF}$

Distributed energy resources (DERs) are projected to be significant contributors in electric power grid modernization efforts. Yet many distribution and transmission system operators are concerned about potential reliability and security impacts of high penetration of DERs, and cite the need of greater visibility and controllability of decision variables associated with these DERs. Tractable modeling of DERs in AC optimal power flow (ACOPF) is one of the barriers to their integration into the existing operation, planning and market paradigm. Similarly, as more intermittent renewable resources are deployed, power flow control becomes more valuable, and accurate representation of Flexible AC Transmission System (FACTS) devices in ACOPF will likely grow in importance. Here this paper focuses on the detailed representation of substations with the high penetration of DERs, and on the Unified Power Flow Controller (UPFC) FACTS devices, in OPF. To this end, a novel Sparse Tableau Formulation (STF) for ACOPF is used to accurately model such features as substation reconfiguration to accommodate DERs, and to represent decision variables appropriate to the voltage source converters within UPFCs. Numerical studies are provided to demonstrate the impacts of detailed DER and UPFC representations on optimal operation, and the computational efficiency.

42 ENGINEERING↗

Machine Learning Solutions for a Stable Grid Recovery

Grid operating security studies are typically employed to establish operating boundaries, ensuring secure and stable operation for a range of operation under NERC guidelines. However, if these boundaries are severely violated, existing system security margins will be largely unknown, as would be a secure incremental dispatch path to higher security margins while continuing to serve load. As an alternative to the use of complex optimizations over dynamic conditions, this work employs the use of machine learning to identify a sequence of secure state transitions which place the grid in a higher degree of operating security with greater static and dynamic stability margins. Several reinforcement learning solution methods were developed using deep learning neural networks, including Deep Q-learning, Mu-Zero, and the continuous algorithms Proximal Reinforcement Learning, and Advantage Actor Critic Learning. The work is demonstrated on a power grid with three control dimensions but can be scaled in size and dimensionality, which is the subject of ongoing research.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Employing a Hardware-in-the-Loop Approach to Realize a Fully Homomorphic Controller for a Small Modular Advanced High Temperature Reactor

This paper addresses the cybersecurity challenges of advanced nuclear reactors by integrating fully homomorphic encryption (FHE) into their control systems, enabling encrypted processing of control signals without compromising functionality. Advanced nuclear reactors, including Small Modular Reactors (SMRs) and microreactors, aim to achieve autonomous and remote operations, reducing costs and enhancing competitiveness. However, these advancements expand the attack surface for cyberattacks, particularly in autonomous and remote operation scenarios. Cyberattacks can exploit vulnerabilities to manipulate physical processes, causing shutdowns, asset damage, or public harm. Such attacks begin with passive reconnaissance, where adversaries intercept communications or observe behaviors to gather information, which is then leveraged to execute cyber-physical attacks by injecting malicious commands. Nuclear power must adopt cybersecurity protection measures to secure the integrity and availability of their digital control systems. This paper demonstrates the application of FHE to secure operations by enabling encrypted processing of sensitive signals and parameters -- ensuring privacy without exposing data. FHE supports secure mathematical operations on encrypted data without requiring decryption. Using a hardware-in-the-loop (HIL) approach, this paper implements an FHE-integrated controller on a BeagleBone Black (BBB) controlling a simulation of the Small Modular Advanced High Temperature Reactor (SmAHTR). By doing so, the encrypted controller protects the integrity of critical set points and control signals during transmission and processing. Thus, FHE-integrated controllers enhance secure operations of advanced nuclear reactors while maintaining functionality.

control systems↗