Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “online”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Online Calculator to Evaluate the Impact of Airtightness on Residential Building Energy Consumption and Moisture Transfer

Energy consumption in residential buildings is primarily driven by space conditioning applications. Space heating and cooling, on average, consume approximately 50% of the energy in the residential buildings in the U.S. The primary energy use due to infiltration is more than 2.8 Quads, which is 29% of primary energy consumption attributable to fenestration and building envelope components in residential buildings in US in 2010. There are advanced air barrier technologies and construction practices to reduce air leakage in buildings, which are currently available in the market. However, the lack of adequate information on their impact on energy consumption and the durability of buildings has caused the slow adoption of these technologies and methods. In the past, the authors developed an online calculator that estimates the potential energy and cost savings in major U.S., Canadian and Chinese cities from improvement in airtightness in commercial buildings. In 2018–2019, the calculator was expanded to add moisture transfer calculations, given that air leakage through the building envelope can have a significant impact on moisture transfer. The calculator is again being expanded by adding residential and additional commercial building data. In this paper, we present the impact of airtightness in residential buildings on energy consumption and moisture transfer. The study includes the analysis of airtightness in 52 major cities in the U.S. and five cities in Canada on a residential building that includes a crawlspace and has a gas furnace.

Kunwar, Niraj↗

Online Tracking of Two Dominant Inter-Area Modes of Oscillation in the Eastern Interconnection

Reliable power system operation requires that small-signal stability be maintained at all times. Mode meters are measurement-based tools that provide operators with situational awareness of the system's stability margin. They operate by continually tracking the inter-area modes of oscillation that govern small-signal stability. This paper reports on the deployment of mode meters for online monitoring of two dominant modes of oscillation in the United States' Eastern Interconnection (EI). The use of measurements from system operators across the interconnection to provide continuous tracking is novel in the EI. Results from over four months of analysis reveal diurnal patterns in the modes and demonstrate that they can be tracked through a variety of system conditions. The results from this study continue to build an understanding of the EI's modes that will inform future modeling and monitoring efforts.

Follum, James D.↗

Systems and methods for online power management for hybrid powertrains

At least some embodiments of the present disclosure are directed to systems and methods of online power management for hybrid powertrains. In some embodiments, the hybrid powertrain control system is configured to conduct a brake-thermal-efficiency (BTE) estimation procedure when the powertrain is in operation by operating the hybrid powertrain at a plurality of speeds for a plurality of designated power levels and select certain BTE operating conditions to update the power management.

Gosala, Dheeraj B.↗

Benefits of the SolarAPP+ Online Permitting Software

The Solar Automated Permit Processing Plus (SolarAPP+) software is an online platform that provides plan review and instantly issues permits for code-compliant residential photovoltaic (PV) systems.

automated permitting↗

A Molten Salt Aerosol Spectroscopy Approach to Online Process Monitoring in Molten Salt Reactors

Recent research and development in molten salt reactors (MSRs) has led to many advanced reactor designs, many of which have demonstrations planned in the next decade. However, a significant challenge that must be overcome before liquid fueled MSRs become viable globally is nuclear material accountancy (NMA) and safeguards. Liquid-fueled MSRs are problematic to safeguards because the nuclear material is in the bulk phase, inventories are constantly changing, and there are potentially many outlet pathways that must be monitored, especially in designs with online chemical processing. At the Idaho National Laboratory, we have developed a process monitoring tool to circulate molten salt through a nebulizer and optical cell, where laser-induced breakdown spectroscopy (LIBS) and ultraviolet-visible (UV-VIS) are applied to track the elemental and oxidation states of the constituents in the salt aerosol. This approach has the potential to provide information on the actinides, fission products, and corrosion in the reactor or process. Preliminary testing in aqueous praseodymium chloride (PrCl3) and neodymium chloride (NdCl3) showed good sensitivity detection limits n developed calibration curves. Additional tests and analysis or ongoing in aqueous solutions while equipment is being scaled up for high temperature molten salt testing. Results for continued testing as well as a status of the molten salt design and anticipated commissioning will be presented.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Online Molten Salt and Gas Monitoring Using Combined Spectroscopic Methods

The nonproliferation of nuclear material and the development of safeguards technologies to sample and analyze fuel salt is a challenge for molten salt reactor (MSR) developers. We seek online monitoring using combined spectroscopic methods of two distinct material phases from MSR’s. Molten salt transformed to aerosol phase allows for Light Induced Breakdown spectroscopy (LIBS) without adverse splashing (ARPA-E). Vaporized used nuclear fuel through chlorine-based volatility (CBV) allows for uranium separation based on boiling point differences

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Development of online pulse-finding algorithms for the Mu2e Stopping Target Monitor and an evaluation of the signal to background ratio for the Mu2e stopped-muon rate determination

This thesis presents a determination of the acceptance of the Mu2e Stopping Target Monitor (STM) detector for both signal and background events. The rate of X-rays of a specific energy in the STM is used to determine the rate of stopped muons in the aluminium stopping target, which is used as the normalisation for all Mu2e measurements, particularly the branching ratio for a charged lepton flavour violating (cLFV) process. The acceptance for the 347\,keV $2p-1s$ aluminium signal X-ray is determined to be $(8.03 \pm 0.05) \times 10^{-10}$\,cm$^{-2}$ and the acceptance for the background photons (at 347\,keV) to be $(3.19 \pm 0.21) \times 10^{-8}$\,cm$^{-2}$. This results in a signal-to-background ratio of approximately two which is significantly higher than had previously been estimated. These signal-to-background rates are used to determine the time required to achieve a statistical uncertainty of 10\% on the number of 347\,keV X-rays as a function of the detector resolution and back ground rate. For a resolution of 2\,keV, and the background rate determined in this thesis, approximately one minute of data is required. The three corrections needed to be applied to the measured 347\,keV rate to determine the rate of stopped muons are also determined and potential sources of bias arising from the background shape, background fit range and energy calibration are investigated and found to be insignificant. The raw energy of the particles in the STM detector comes from a 16-bit ADC digitising at $\sim 300$\,MHz. It is not possible to store all the raw digitisations and online algorithms have been developed to rapidly select pulses in the detector and reconstruct their energy. The performance of these algorithms has been characterised with simulated data as a function of detector rate and resolution and optimum operating points for the algorithms have been defined. The integrity of the algorithms has also been demonstrated and characterised on test-beam data at high r ates and with radioactive sources at low rates.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calorimeter Pileup Deconvolution for Online Trigger Primitives

In high energy physics experiment, as the luminosity increases, pile-up issues on detectors such as calorimeters become non-negligible. Deconvolution approaches with mathematic pre-assumptions such as Sparse Representation are developed for data analysis stage. For online computation tasks such as for trigger primitive creation, signal availability is significantly different as in offline data analysis stage, and therefore, different (yet simpler) algorithms should be explored. In this document, several approaches of deconvolution suitable for FPGA implementation are discussed.

Wu, Jin-yuan [Fermilab] (ORCID:0000000344329521)↗

Online Alpha Monitoring of High Cs-137 Hanford and SRS High Level Waste with Tensioned Metastable Fluid Detectors

The Department of Energy’s Hanford and Savannah River Sites maintain millions of gallons of caustic supernate and salt high activity waste in their high-level waste (HLW) tank farm inventories. The Savannah River Site is currently treating this waste with a calixarene-based solvent extraction of Cs-137 to reduce these inventories. Hanford is employing an at-tank crystalline silico titanate (CST) based solid phase extraction methodology to reduce their liquid HLW inventories. Due to the high solubility of Cs-137 and the relative insolubility of the actinides in these caustic waste forms, the beta to alpha radioactivity ratio can often exceed six orders of magnitude in the feed solutions to these treatment processes. This unique characteristic leads to significant technical challenges in making rapid gross alpha measurements in the presence of the overwhelming beta, gamma, as well as dissolved sodium salt in these HLW matrices. Conventional radioanalytical techniques, such as liquid scintillation analysis or gas flow proportional counting require significant radiochemistry preparation prior to the radiometric measurements for gross alpha activity. These required pretreatments render these technologies untenable for rapid quantification of gross alpha activity that could be required to support on or at-line measurements ensuring a waste stream will meet regulatory requirements. The radiation measurement properties of Tensioned Metastable Fluid Detectors (TMFDs) have been studied by Purdue University’s Taleyarkhan research group for well over a decade. Fluids tensioned to the appropriate degree will rupture when struck by radiation, resulting in a measurable cavitation event. The negative pressure generating this tension can be adjusted by centrifugal rotation or by acoustic means in such a way that these cavitation events can be generated from alpha radiation but will not be generated by beta or gamma radiation. Purdue University and the Savannah River National Laboratory are currently collaborating to develop a gamma/beta blind, spectroscopic alpha measurement system based on the Tensioned Metastable Fluid Detector technology to provide a potential solution for performing rapid gross alpha measurements on these high gamma/beta sample matrices. Measurements using the Indirect Drive Acoustically Tensioned Metastable Fluid Detectors developed as part of this collaboration were performed with an alpha emitting radionuclide. Successful determination of gross alpha activity was observed, indicating a potential pathway for rapid gross alpha measurements in remote-handled shielded cells or in process situations requiring online alpha monitoring. Measurements using this system have been conducted on high beta activity solutions, demonstrating the beta blind capability of this system. Measurements are currently underway to test the system’s capability to measure gross alpha activity on Savannah River Site high level waste high Cs-137 samples that have been measured by the SRNL radiochemistry team. This work was supported by the DOE EM Technology Development program.

DiPrete, David [Savannah River National Laboratory↗

Online and Offline Data Quality Monitoring for the Mu2e Calorimeter

This thesis presents the design, implementation, and validation of a calorimeter Data Quality Monitoring (DQM) toolchain for the Mu2e experiment at Fermilab. Mu2e searches for charged lepton flavor violation via coherent muon-to-electron conversion in the field of an aluminum nucleus, $\mu^- Al \rightarrow e^-Al$, a process whose observation would constitute clear evidence of physics beyond the Standard Model. Achieving target sensitivity requires stringent control of detector performance and data integrity during acquisition, as subtle issues in readout configuration, data formatting, or electronics behavior can compromise reconstruction and bias downstream analyzes. To address these challenges, this work develops a multi-layer DQM approach spanning both raw data validation and reconstructed digi-level diagnostics. At the low level, a fragment analysis component performs word- and bit-field decoding of calorimeter readout blocks, enabling sanity checks of the expected structure and producing detailed error and integrity statistics useful for commissioning and troubleshooting. At the digi level, the CaloDigiDQM analyzer is implemented within the art framework and transforms each CaloDigiCollection into a structured hierarchy of ROOT histograms designed for fast drill-down diagnostics. The module generates coherent monitoring views at global, disk, board, and channel granularity, including occupancy, waveform-derived features (baseline, RMS, peak amplitude and position), and left-right sensor consistency metrics. Detector-aware channel-to-electronics mapping is performed through the conditions system (CaloDAQMap), ensuring that diagnostics remain aligned with hardware identifiers used in operations. For end-to-end testing without reliance on live DAQ data, a synthetic CaloDigi producer is developed to generate realistic waveforms with controlled noise and pulse shapes. The resulting system supports both offline ROOT-file production and online operation, including optional histogram streaming through otsdaq via ots::HistoSender. This toolchain provides a practical and scalable foundation for calorimeter commissioning and stable data collection, enabling early detection of anomalies and reducing operational risk for Mu2e.

Vakulenko, Mark [Drew U.] (ORCID:0009000276197818)↗

Development of an Attenuated Total Reflectance–Ultraviolet–Visible Probe for the Online Monitoring of Dark Solutions

Optical spectroscopy is a valuable tool for on-line monitoring of a variety of processes. Ultraviolet-visible (UV-vis) spectroscopy in particular, can monitor the concentration of analytes as well as identify speciation and oxidation state. However, it can be difficult to impossible to employ UV-vis based sensors on chemical systems that are very dark (i.e., high optical density) as exceedingly short pathlengths are required (for transmission approaches) or effective means of backscattering are needed (for reflectance approaches). Examples of processes that would benefit significantly from the use of optical sensors and encounter these challenges include used nuclear fuel recycling and molten salts with high concentrations of dissolved uranium. Utilizing an attenuated total reflectance (ATR) UV-vis approach can overcome these challenges and allow for the measurement of solutions orders of magnitude more concentrated than transmission UV-vis. However, determining ideal sensor specifications for varied processes can be time consuming and expensive. Here, in this study, we evaluate the ability for a novel ATR-UV-vis probe to measure very concentrated solutions of Co(II) and Ni(II) nitrate as well as organic dyes (methylene blue, acid red 1, and crystal violet). This sensor design provides a modular method for exploring possible “pathlengths” by altering the exposed ATR fiber length. Also studied were approaches to loading and measuring the sensor cell. These results are compared to a traditional 1 cm cuvette measured by transmission UV-vis. It was found that the ATR-UV-vis probe was capable of measuring solutions 600 times more concentrated than the 1 cm cuvette. Advanced data analysis in the form of multivariate curve resolution (MCR) was used to analyze the speciation of methylene blue over a large concentration range. The application of this novel ATR-UV-vis probe to the interrogation of dark solutions is a promising avenue for use in on-line monitoring of nuclear processes.

47 OTHER INSTRUMENTATION↗

Automated Calibration for Rapid Optical Spectroscopy Sensor Development for Online Monitoring

An automated platform has been developed to assist researchers in the rapid development of optical spectroscopy sensors to quantify species from spectral data. This platform performs calibration and validation measurements simultaneously. Real-time, in situ monitoring of complex systems through optical spectroscopy has been shown to be a useful tool; however, building calibration models requires development time, which can be a limiting factor in the case of radiological or otherwise hazardous systems. While calibration time can be reduced through optimized design of experiments, this study approached the challenge differently through automation. The ATLAS (Automated Transient Learning for Applied Sensors) platform used pneumatic control of stock solutions to cycle flow profiles through desired calibration concentrations for multivariate model construction. Additionally, the transients between desired concentrations based on flow calculations were used as validation measurements to understand model predictive capabilities. This automated approach yielded an incredible 76% reduction in model development time and a 60% reduction in sample volume versus estimated manual sample preparation and static measurements. The ATLAS system was demonstrated on two systems: a three-lanthanide system with Pr/Nd/Ho representing a use case with significant overlap or interference between analyte signatures and an alternate system containing Pr/Nd/Ni to demonstrate a use case in which broad-band corrosion species signatures interfered with more distinct lanthanide absorbance profiles. Both systems resulted in strong model prediction performance (RMSEP < 9%). Lastly, ATLAS was demonstrated as a tool to simulate process monitoring scenarios (e.g., column separation) in which models can be further optimized to account for day-to-day changes as necessary (e.g., baseline correction). Ultimately, ATLAS offers a vital tool to rapidly screen monitoring methods, investigate sensor fusion, and explore more complex systems (i.e., larger numbers of species).

47 OTHER INSTRUMENTATION↗

Online Learning and Pricing for Network Revenue Management with Reusable Resources

We consider a price-based network revenue management problem with multiple products and multiple reusable resources. Each randomly arriving customer requests a product (service) that needs to occupy a sequence of reusable resources (servers). We adopt an incomplete information setting where the firm does not know the price-demand function for each product and the goal is to dynamically set prices of all products to maximize the total expected revenue of serving customers. We propose novel batched bandit learning algorithms for finding near-optimal pricing policies, and show that they admit a near-optimal cumulative regret bound of $O(J\sqrt{XT})$, where J, X, and T, are the numbers of products, candidate prices, and service periods, respectively. As part of our regret analysis, we develop the first finite-time mixing time analysis of an open network queueing system (i.e., the celebrated Jackson Network), which could be of independent interest. Our numerical studies show that the proposed approaches perform consistently well.

42 ENGINEERING↗

Online Lead/Water Heat Exchanger Sensor/System Feasibility-PNNL (Final Report)

On-line structural health corrosion monitoring in advanced lead fast reactor heat exchangers and molten salt reactor heat exchangers is desirable for detecting tube degradation prior to leaks that may allow mixing of heat exchanger fluids or release of radiological contamination beyond the design containment boundary. This program, On-Line Lead/Water Heat Exchanger Sensor/System Feasibility – PNNL 76092, demonstrates feasibility for an ultrasonic torsional wave mode sensor attached to the outside of a long (30.5-m) heat exchanger tube in the stagnant flow area where the tube joins a heat exchanger plenum and where it is possible to protect a sensor and cable from high-force flows. The sensor must be cable connected to a monitoring instrument near the heat exchanger. The sensor and cable management approach for periodic in-service inspection will be impractical to implement on existing heat exchangers; rather permanently mounted sensors must be installed in conjunction with heat exchanger fabrication. Previous work has shown low-temperature lead zirconate titanate (PZT) piezoceramic sensors are able to detect anomalies of interest in 3.0-m long tubes. These sensors have hereby been extended to a 30.5-m long tube more representative of commercial power heat exchanger designs. The program will continue to investigate higher temperature piezoelectric ceramics and long-term performance of high temperature adhesives and sealants and mechanical pressure coupling for 350-500 °C lead reactor environments and higher temperature (700 °C) molten salt environments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An Online Dynamic Amplitude-Correcting Gradient Estimation Technique to Align X-ray Focusing Optics

High-brightness X-ray pulses, as generated at synchrotrons and X-ray free electron lasers (XFELs), are used in a variety of scientific experiments. At these facilities, measurements often require optical equipment, e.g Compound Refractive Lenses (CRLs) to be precisely aligned and focused. The lateral alignment of CRLs to a beamline requires precise positioning along four axes: two translational, and the two rotational. At a synchrotron, alignment is often accomplished manually. However, XFEL beamlines present a beam brightness that fluctuates stochastically, making manual alignment a time-consuming endeavor. Automation using simplex or classic stochastic descent often fails, given the errant gradient estimates. Herein we present a dynamic-amplitude correction to the usual gradient based on the combination of a generalized finite difference stencil and a time-dependent sampling pattern. Intensity is recorded periodically, then used to normalize numerical derivatives against fluctuations. Error expectation is analyzed, and efficacy is demonstrated on classic benchmarks. We provide a proof of concept by laterally aligning optics on a simulated XFEL beamline using data recorded at both synchrotron and XFEL facilities.

97 MATHEMATICS AND COMPUTING↗