Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “occupancy schedule”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A Coupled Probabilistic Wake Vortex and Aircraft Response Prediction Model

Wake vortex spacing standards along with weather and runway occupancy time, restrict terminal area throughput and impose major constraints on the overall capacity and efficiency of the National Airspace System (NAS). For more than two decades, the National Aeronautics and Space Administration (NASA) has been conducting research on characterizing wake vortex behavior in order to develop fast-time wake transport and decay prediction models. It is expected that the models can be used in the systems level design of advanced air traffic management (ATM) concepts that safely increase the capacity of the NAS. It is also envisioned that at a later stage of maturity, these models could potentially be used operationally, in groundbased spacing and scheduling systems as well as on the flight deck.

Gloudemans, Thijs↗

Hydronic Heating Coil Versus Propane Furnace, Rehoboth Beach, Delaware (Fact Sheet)

Insight Homes constructed two houses in Rehoboth Beach, Delaware, with identical floor plans and thermal envelopes but different heating and domestic hot water (DHW) systems. Each house is 1,715-ft 2 with a single story, three bedrooms, two bathrooms, and the heating, ventilation, and air conditioning (HVAC) systems and ductwork located in conditioned crawlspaces. The standard house, which the builder offers as its standard production house, uses an air source heat pump (ASHP) with supplemental propane furnace heating. The Building America test house uses the same ASHP unit with supplemental heat provided by the DHW heater (a combined DHW and hydronic heating system, where the hydronic heating element is in the air handler). Both houses were occupied during the test period. Results indicate that efficiency of the two heating systems was not significantly different. Three issues dominate these results; lower system design performance resulting from the indoor refrigerant coil selected for the standard house, an incorrectly functioning defrost cycle in the standard house, and the low resolution of the natural gas monitoring equipment. The thermal comfort of both houses fell outside the ASHRAE Standard 55 heating range but was within the ACCA room-to-room temperature range when compared to the thermostat temperature. The monitored DHW draw schedules were input into EnergyPlus to evaluate the efficiency of the tankless hot water heater model using the two monitored profiles and the Building America House Simulation Protocols. The results indicate that the simulation is not significantly impacted by the draw profiles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advances in remote monitoring technology for worker safety and personnel radiation exposure reduction - 15130

This paper will present an overview of advancements made in remote monitoring technology to increase worker safety and decrease personnel radiation exposure at hazardous work sites. The presentation will discuss the use of remote technology for risk reduction to working parties. Topics covered will be the use of technology as a human performance tool in pre and post job briefings, scheduling tool for work management and communication tool between working parties and radiation protection personnel that allow for micro-managing radiation exposure. The presentation will use actual technology field experience to illustrate best practices within the commercial nuclear industry and there applicability to the waste management sector. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

French Innovative Processes in the Field of Thermal Treatment For Decommissioning and Legacy Waste - 18085

In order to optimize decommissioning waste management and better anticipate related issues, French nuclear waste producers CEA and AREVA, and the French Agency in charge of radioactive waste disposal (ANDRA) have decided to collectively develop technologies mastering costs, schedules and dose uptake as well as optimizing waste volumes and repository safety. In this context, several innovative projects have emerged over the past few years to develop specific thermal treatment processes. This paper focus on four new processes, presenting their goals, technical descriptions and first experimental results. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Tank Farm Vapors Abatement Technology and Vendor Proposals Assessment

Suspected chemical vapor releases from the Hanford nuclear waste tank system pose concerns for worker exposure. Washington River Protection Solutions (WRPS) contracted the Savannah River National Laboratory (SRNL) to explore abatement technologies and strategies to remediate the vapors emitted through the ventilation system. In response, SRNL conducted an evaluation of technologies to abate, or reduce, vapor emissions to below 10% of the recognized occupational exposure limits (OELs). The evaluation included a review of published literature and a broadly communicated Request for Information to commercial vendors through a Federal Business Opportunities (Fed Biz Opps) web posting. In addition, SRNL conducted a workshop and post-workshop conference calls with interested suppliers (vendors) to assess proposals of relevant technologies. This report reviews applicable technologies and summarizes the approaches proposed by the vendors who participated in the workshop and teleconference interviews. In addition, the report evaluates the estimated performance of the individual technologies for the various classes of chemical compounds present in the Hanford Chemicals of Potential Concern (COPCs) list. Similarly, the report provides a relative evaluation of the vendor proposed approaches against criteria of: technical feasibility (and maturity), design features, operational considerations, secondary waste generation, safety/regulatory, and cost / schedule. These rough order-of-magnitude (ROM) cost estimates are intended to provide a comparison basis between technologies and are not intended to be actual project estimates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

What Employees Need (and Want) to Hear When Justifying the Suspension of a Regulated Metals Plan for the Processing of Drums Containing Metal Turnings

A Regulated Metals Plan (RMP) was implemented for outdoor work activities involving the removal and disposition of approximately 4,000 deteriorated waste drums containing 236 metric tonnes (260 tons) of lead turnings from various, unspecified machine shop facilities at the Paducah Gaseous Diffusion Plant. Until exposure monitoring could prove otherwise, the work area established for processing the drums was conservatively defined as a Lead Regulated Area (LRA) subject to the Occupational Safety and Health Administration's Lead Standard found in Title 29 of the Code of Federal Regulations, Part 1910.1025. The vast majority of the analytical results for the industrial hygiene breathing zone samples collected and tested for arsenic, beryllium, cadmium, chromium, lead, nickel, selenium, silver, and thallium using the National Institute for Occupational Safety and Health's analytical method 7300 were equivalent to the laboratory detection limits for each analyte. All results were less than 6% of their respective Permissible Exposure Limits (PEL), except for one nickel result that was approximately 17% of its PEL. The results provided justification to eventually down-post the LRA to existing employee protection requirements. In addition to removing the deteriorated drums and accompanying debris, the success of this project was quantified in terms of zero recordable injuries. The primary contributor in achieving this success was the sharing and communication of information between management, safety, and the field teams. Specifically, this was what the employees needed (and wanted) to hear when justifying the suspension of the RMP for the processing of drums containing metal turnings. Daily briefings on the status of the project and field monitoring results were just as important as maintaining budget and schedule milestones. Also, the Environmental, Safety and Health organization maintained its presence by continuing to monitor evolving field conditions to ensure the effectiveness of its plans and procedures. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technology Development and Field Monitoring in nZEB - US Country report IEA HPT Annex 49 Task 3

The International Energy Agency (IEA) Heat Pumping Technologies (HPT) Annex 49, “Design and Integration of Heat Pumps for Nearly Zero Energy Buildings,” deals with the application of heat pumps (HPs) as a core component of the HVAC system for nearly or net-zero energy buildings. This report covers the Task 3 activities of the US team. Three institutions are involved on the US team and have worked on the following projects. 1) Oak Ridge National Laboratory (ORNL) summarized development activities since the conclusion of IEA HPT Annex 40 for several integrated HP (IHP) systems - electric ground-source IHP and air-source IHP versions and engine-driven AS-IHP version. 2) The University of Maryland partnered with ORNL and Blue Bear Management to develop a personal cooling device called RoCo that can provide personalized conditioned air to occupants in inadequately or unconditioned environments. With RoCo, building facility management can elevate the HVAC thermostat settings without compromising occupants’ thermal comfort. Researchers have found that a 4°F increase in thermostat settings can save 12–30% energy savings. Therefore, RoCo is a promising technology that can help reduce building energy consumption and facilitate achievement of net-zero energy building performance. 3) The National Institute of Standards and Technology (NIST) is working on a field study effort on the NIST Net-Zero Energy Residential Test Facility. Two air-source split-system HPs were installed in a residential, net-zero energy home that was constructed as a laboratory on the NIST campus in Gaithersburg, Maryland. The first HP was a two-stage, 7 kW (2 ton), 15.8 seasonal energy efficiency ratio (SEER), 9.05 heating seasonal performance factor (HSPF) conventionally ducted system; the second HP was a variable-speed, 10.6 kW (3 ton), 14 SEER, 8.35 HSPF, high-velocity ducted system. These two systems operated side by side, using separate supply ducts and a common return duct, on a weekly alternating schedule to condition the home that was operated with very consistent simulated thermal loads. The team wanted to determine whether the high-velocity system could provide comparable energy-use efficiency to the conventional system. The results of this study showed that it did meet the required loads and had slightly greater efficiency; the average cooling coefficient of performance (COP) was (0.40 ± 0.11) higher, and the average heating COP was statistically equal. A new firmware was provided at the end of the heating season that greatly improved the performance of the high-velocity system; its average heating COP went from (1.8 ± 0.9) to (2.5 ± 1.1) at a 95% confidence level. The new firmware heating COP averaged (1.05 ± 0.23) higher than the old firmware over the same outdoor temperatures. The defrost performance is very different for these two systems, yet they consumed equivalent energy per HDD. The conventional system uses a timed-initiate, temperature-terminate algorithm with auxiliary electric resistive heating, whereas the high-velocity system uses calculated evaporator parameters with a hot-gas bypass before a full reverse-cycle defrost with no supplementary resistive heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demographics, sleep, and daily patterns of caffeine intake of shift workers in a nationally representative sample of the US adult population

Abstract Study Objective Caffeine is the most widely consumed stimulant in the world, and sociodemographic factors including occupation are associated with intake. Shift work, required in various occupations, is associated with poor sleep, inadequate diet, and adverse health effects. Using a large nationally representative database, demographics, sleep, and caffeine intake of US adults working various shifts were assessed. Methods The 24-hour dietary recall data from NHANES 2005–2010 (N = 8,500) were used to estimate caffeine intake from foods and beverages. Work shifts were self-reported as follows: regular day shift; evening shift; night shift; rotating shift; or other shift. Regression analyses assessed associations of shift work with caffeine intake after adjustment for sociodemographic factors. Results Approximately 74% of employed adults were day-shift workers and 26% were nonday-shift workers. Night-shift workers slept for 6.25 ± 0.09 hours per day, somewhat less than day-shift workers who only slept 6.83 ± 0.02 hours (p < .0001). Mean 24-hour weekday caffeine intake of evening-, night-, and rotating-shift workers (217 ± 23, 184 ± 19, and 206 ± 15 mg, respectively) was similar (p > .3) to day-shift workers (203 ± 5 mg). Regardless of work schedule, individuals consumed the most caffeine during morning hours. Evening- and night-shift workers reported consuming 36%–46% less caffeine during their work hours and 72%–169% more during nonwork hours than day-shift workers (p < .01). Conclusions Total daily caffeine intake of shift workers is similar to nonshift workers; most caffeine is consumed in the morning regardless of shift. Because shift workers consume less caffeine during regular work hours and more during nonwork hours than day workers, they may be using caffeine to, in part, optimize off-duty alertness.

Lieberman, Harris R.↗

JDD, Inc. Database

JDD Inc, is a maintenance and custodial contracting company whose mission is to provide their clients in the private and government sectors "quality construction, construction management and cleaning services in the most efficient and cost effective manners, (JDD, Inc. Mission Statement)." This company provides facilities support for Fort Riley in Fo,rt Riley, Kansas and the NASA John H. Glenn Research Center at Lewis Field here in Cleveland, Ohio. JDD, Inc. is owned and operated by James Vaughn, who started as painter at NASA Glenn and has been working here for the past seventeen years. This summer I worked under Devan Anderson, who is the safety manager for JDD Inc. in the Logistics and Technical Information Division at Glenn Research Center The LTID provides all transportation, secretarial, security needs and contract management of these various services for the center. As a safety manager, my mentor provides Occupational Health and Safety Occupation (OSHA) compliance to all JDD, Inc. employees and handles all other issues (Environmental Protection Agency issues, workers compensation, safety and health training) involving to job safety. My summer assignment was not as considered "groundbreaking research" like many other summer interns have done in the past, but it is just as important and beneficial to JDD, Inc. I initially created a database using a Microsoft Excel program to classify and categorize data pertaining to numerous safety training certification courses instructed by our safety manager during the course of the fiscal year. This early portion of the database consisted of only data (training field index, employees who were present at these training courses and who was absent) from the training certification courses. Once I completed this phase of the database, I decided to expand the database and add as many dimensions to it as possible. Throughout the last seven weeks, I have been compiling more data from day to day operations and been adding the information to the database. It now consists of seven different categories of data (carpet cleaning, forms, NASA Event Schedules, training certifications, wall and vent cleaning, work schedules, and miscellaneous) . I also did some field inspecting with the supervisors around the site and was present at all of the training certification courses that have been scheduled since June 2004. My future outlook for the JDD, Inc. database is to have all of company s information from future contract proposals, weekly inventory, to employee timesheets all in this same database.

Miller, David A., Jr.↗

A Survey of Multizone Airflow Simulation Software

H-Canyon simulates the building and process ventilation to ensure positive contamination control for any modifications as well as evaluating off-normal conditions. Simulations can also be used to identify air quality of personnel occupied areas. The models can be classified into two groups, single and multi-zone models. As the name states, a single zone model assumes that the building can be described by a single, well-mixed zone. Whereas large buildings have structures that must be described as multizone. Multizone airflow models deal with the difficulty of flows in a building by distinguishing the effects of internal flow restrictions. Several models have been developed that take internal partitions into account. CONTAM (currently used) is a multizone airflow program created by NIST to determine airflows including infiltration, exfiltration, wind pressures acting outside the building, buoyancy effects caused by the indoor and outdoor air temperature difference. COMIS is a multizone air infiltration, ventilation, and contaminant transport model that was developed at Lawrence Berkeley National Laboratory. COMIS deals with applied pressure distribution, airflow components, HVAC systems, schedules, and contaminant transport. EnergyPlus is designed by DOE. It supports flexible component level configuration of HVAC models and simulates sub-hourly time steps to control fast dynamic systems. The program features include providing accurate environmental performance data including energy consumption and carbon emissions, and reporting solar gains on surfaces. Heavent is used to model industrial ventilation systems to control airborne contaminants. It's designed based on the American Conference of Governmental Industrial Hygienists (ACGIH) Ventilation manual. DesignBuilder is the most recognized and advanced user interface to EnergyPlus. It gives access to all of the most frequently required simulation capabilities covering building fabric, thermal mass, glazing, shading renewables, and HVAC analysis. The objective of this study is to identify all relevant software available including commercially licensed, freely licensed, and open source, that can be used to simulate large, complex process facility ventilation systems. All discovered software tools are evaluated for salient features and compared to the software tool currently used to simulate the H-Canyon ventilation system. The design criteria of a ventilation system has two basic requirements: Supplying fresh air for the occupants and changing the air in the room sufficiently; therefore, the smells, fumes, and contaminants will be removed. In this study, first, whether the software simulates airflow (infiltration, natural ventilation, and interzonal) or considers them to be inputs is discussed. Second, if indoor contaminant levels are considered; and finally suggestions on how airflow analysis can be more appropriately accounted for when performing airflow simulation of a building. All of the airflow software reviewed for this study can account for constant infiltration and natural ventilation rates that are not affected by changes in indoor and outdoor conditions. Modelling infiltration in EnergyPlus or DesignBuilder are applicable for small buildings and not appropriate for larger buildings like the H-Canyon. The effect of wind on external pressures, infiltration, and natural and mechanical ventilation, can also be calculated using all of these software. These programs have control options to switch between natural to mechanical ventilation modes or both (hybrid). Interzonal airflow can be applied which means one zone can be specified to receive a fixed amount of air from another zone. The following ventilation modeling software is recommended for further testing: CONTAM, COMIS, Heavent. The next step in evaluating the software will consist of creating test facility simulations using evaluation copies of the software.

42 ENGINEERING↗

Curb Allocation and Pick-Up Drop-Off Aggregation for a Shared Autonomous Vehicle Fleet

Advances in information technologies and vehicle automation have birthed new transportation services, including shared autonomous vehicles (SAVs). Shared autonomous vehicles are on-demand self-driving taxis, with flexible routes and schedules, able to replace personal vehicles for many trips in the near future. The siting and density of pick-up and drop-off (PUDO) points for SAVs, much like bus stops, can be key in planning SAV fleet operations, since PUDOs impact SAV demand, route choices, passenger wait times, and network congestion. Unlike traditional human-driven taxis and ride-hailing vehicles like Lyft and Uber, SAVs are unlikely to engage in quasi-legal procedures, like double parking or fire hydrant pick-ups. In congested settings, like central business districts (CBD) or airport curbs, SAVs and others will not be allowed to pick up and drop off passengers wherever they like. This paper uses an agent-based simulation to model the impact of different PUDO locations and densities in the Austin, Texas CBD, where land values are highest and curb spaces are coveted. In this paper 18 scenarios were tested, varying PUDO density, fleet size and fare price. The results show that for a given fare price and fleet size, PUDO spacing (e.g., one block vs. three blocks) has significant impact on ridership, vehicle-miles travelled, vehicle occupancy, and revenue. A good fleet size to serve the region’s 80 core square miles is 4000 SAVs, charging a $1 fare per mile of travel distance, and with PUDOs spaced three blocks of distance apart from each other in the CBD.

Hunter, Christian B.↗

Energy-Efficient and Comfortable Buildings through Multivariate Integrated Control (ECoMIC)

This project aims to develop an integrated control solution for enhanced energy efficiency and user comfort in commercial buildings. The developed technology is a zone-based control framework that minimizes energy usage while maintaining occupants’ visual and thermal comfort through control of electric lights, motorized venetian blinds and thermostats. The control framework is designed following a modular, scalable and flexible architecture to facilitate easy integration with exiting building management systems. The control framework contains two key algorithms: 1) the lighting load balancing algorithm and 2) the thermostat control algorithm. The lighting load balancing algorithm adopts a model-based closed-loop control approach to determine the optimal electric light and venetian blind settings. It is formulated into an optimization problem with minimizing lighting-related energy consumptions as the objective and delivering adequate task light and preventing daylight glare as the constraints. The thermostat control algorithm is based on a well-established thermal comfort model and formulated as a root-finding problem to dynamically determine the optimal thermostat setpoint for both energy savings and improved thermal comfort. To address building-wide scalability, a system architecture was developed for the zone-based control technology. Three levels of services are defined in the architecture: external services, facility level services and zone level services. The zone-level service includes the control algorithms described above as well as the corresponding interfaces, profiles, sensors and actuators to realize the zone controller. The facility level services connect to the zones through a backbone network, handle supervisory level information and controls, and thus facilitate building-wide scalability. The external services provide communication capability to entities outside of the building for grid interaction and remote access. Various aspects of the developed control technology were evaluated and verified through both simulations and testbed implementations. Simulations coupling a DOE medium office reference building in EnergyPlus building simulation software and a prototype controller in Matlab were performed. During summer time in a mixed-humid climate zone, the simulations revealed reductions of 27% and 42% in electric lighting load and cooling load, respectively, when compared to an advanced base case with daylight dimming and blinds automatically tilted to block direct sun. Two single-room testbeds were established. The testbed at Philips Lighting business building (Rosemont, IL) was designed for quantifying energy performance of integrated controls. This particular implementation achieved 40% and 79% savings on lighting and HVAC energy, respectively, compared to a relatively simple base case operated on predefined schedules. While the resulting energy savings was very encouraging, it should be noted that there may be several caveats associated with it. 1) The test was run during late spring and early summer, and the savings numbers might not be directly used to extrapolate the annual energy savings. 2) Due to the needs for separate control and metering of the small-scale demonstrator within a large building, the HVAC system, hence the corresponding savings, did not represent a typical energy code-compliant design. 3) The light level in the control case was regulated at a particular setpoint, which was lower than then the full-on light level in the base case, and the savings resulted from tuning down the light level to the setpoint was not attributable to the contribution of the developed technology. The testbed at the Lawrence Berkeley National Laboratory (Berkeley, CA) specifically focused on glare control integration, and has demonstrated the feasibility and capability of the glare detection and prevention technique. While the short one-month test in this testbed provided a functional indication of the developed technology, and it would require at least a full solstice-to-solstice cycle to ruinously quantify the performance, which was not possible within the project timeframe. There are certain limitations inherited from the operational assumptions, which could potentially affect the effectiveness and applicability of the developed control technologies. The system takes a typical ceiling-mounting approach for the photosensor locations, and therefore, the control performance relies on proper commissioning or the built-in intelligence of the photosensor for pertinent task light level estimations. For spaces where daylight penetration diminishes significantly deeper into the zone, certain modification to the control algorithms is required to accommodate multiple lighting control subzones and the corresponding sensors for providing a more uniform light level across the entire zone. Integrated control of visual and thermal comfort requires the lighting control zone and thermal control zone to coincide with each other. In other words, the area illuminated by a lighting circuit needs to be the same area served by the thermostat. Thus, the original zoning will potentially constrain the applicability of this technology in retrofitting projects. This project demonstrated the technical feasibility of a zone-based integrated control technology. From the simulation results and testbed implementations, up to 60% lighting energy savings in daylit areas relative to a “no-controls” case can easily be achieved. A 20% reduction of whole building energy consumption is also attainable. In the aspect of occupant comfort, the testbed demonstrated the ability to maintain specified light level on the workplane while promptly mitigate daylight glare 90% of the time. The control system also managed to maintain the thermal environment at a comfortable level 90% of the time. The aspect of system scalability was guaranteed by the system architecture design, based on which the testbeds were instantiated. Analysis on the aspect of economic benefit has yielded an about 6-year payback time for a medium-sized building, including the installation of all hardware and software, such as motorized blinds and LED luminaires. The payback time can be significantly reduced if part of the hardware is already in place for retrofitting projects. It needs to be noted that since the payback analysis was partly based on the testbed performance results, it is constrained by the caveats associated with the testbed implementations. The main uncertainty lies in the contribution from the space conditioning energy savings as it was non-trivial to realistically configure a room-size HVAC system for directly extrapolating whole-building HVAC energy savings. It is recommended to further evaluate the developed technology at a larger scale, where the lighting and HVAC energy consumption can be realistically measured at the building level, to more rigorously quantify the performance potentials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using discrete Bayesian networks for diagnosing and isolating cross-level faults in HVAC systems

Fault detection and diagnosis (FDD) technologies are critical to ensure satisfactory building performance, such as reducing energy wastes and negative impacts on occupant comfort and productivity. Existing FDD technologies mainly focus on component-level FDD solutions, which could lead to mis-diagnosis of cross-level faults in heating, ventilating, and air-conditioning (HVAC) systems. Cross-level faults are those faults that occur in one component or subsystem, but cause operational abnormalities in other components or subsystems, and result in a building level performance degradation. How to effectively diagnose the root cause of a cross-level fault is the focus of this study. Here, this paper presents a novel discrete Bayesian Network (DisBN)-based method for diagnosing cross-level faults in an HVAC system commonly used in commercial buildings. A two-level DisBN structure model is developed in this study. The parameters used in the DisBN model are obtained either from expert knowledge or through machine-learning strategies from normal system operation data. Meanwhile, the probability parameters are discretized to incorporate the uncertainties associated with typical expert knowledge. Thus, the developed DisBN method addresses the challenges many other BN based FDD methods face, i.e., the lack of fault data for BN parameter training. The developed DisBN represents causal relationships between a fault and its cross-level system impacts (i.e., fault symptoms or fault indicators) by considering how fault impacts propagate across different levels in an HVAC system. A weather and schedule information-based Pattern Matching (WPM) method is employed to automatically create WPM baseline data sets for each incoming real time snapshot data from the building systems. Consequently, BN inference and real-time diagnostics are achieved by comparing incoming snapshot data and the WPM baseline data set. The proposed method is evaluated using experimental fault data collected in a campus building. Fault diagnosis results demonstrate that the WPM-DisBN method is effective at locating the root causes of cross-level faults in an HVAC system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Automation and Use of Robotics for Decommissioning Tasks - 18322

Decommissioning across the globe is being executed largely by manual labor. The Organization for Economic Co-operation and Development (OECD) has concluded that the nuclear industry has not fully exploited or implemented current technological capabilities, and relies on sometimes outdated technology to perform decommissioning tasks [1]. To address this issue, EPRI recently published the report Evaluation of System Automation and Robotics for Decommissioning Applications (EPRI 3002010599) [2]. To facilitate wide usage of the guidance by technology developers, the report is publicly available at no cost. The use of more efficient and effective decommissioning technologies and processes could reduce the decommissioning project schedule and therefore reduce the period-dependent costs incurred throughout the decommissioning project. Such systems may also offer a substantial benefit with respect to worker safety and radiation exposure reduction. However, tasks for which use of such systems is beneficial must be carefully considered, being robust and generally trouble free to operate in the demanding environment of commercial power plant decommissioning. A review of the major tasks involved in the decommissioning of a nuclear power plant is presented, with a critical assessment of the benefits for the use of robotics and/or automation. Recommendations for areas of future research and development are identified. The results of this project will be beneficial to global organizations working on development of engineered systems for decommissioning applications by providing a focus on priority tasks. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Future of Work with Robotics - 18599

The DOE Environmental Management mission continues with remaining tasks that are high-hazards to human workers and high-consequences to the nation, resulting in potentially high risks to project costs and schedules. This is the mission pull. At the same time, robotic technologies are hitting a turning point with increased productivity and reliability within society, supporting a technology push. Enabling this push are better computer processing following Moore's Law, breakthroughs in biometric and learning algorithms,and riding a wave of venture funding for intended commercialization of mechatronic and Internet of Thing (IOT) projects. There has been overall improvements in material technologies, algorithms, and software standardization with tools/libraries such as the Robot Operating System (ROS). The internet has made knowledge ubiquitous and the cell phone sector has pushed the boundaries of systems-on-chip technology. This current growth is a race between large global technology companies, and between countries that understand that there is a prize with increased commerce based on being a leader in the field of robotics and automation. This technological advances have placed this technology solidly within the next 4. Industrial Revolution being tracked by the World Economic Council. Policies and law can slow this progression down, but technological changes in adjacent fields will put additional pressure on human workers by being more economical and in saving lives. A fundamental issue is will this change be gradual or disruptive such as with the forecasted singularity. There is also a realization with automation that the transition of human workers to other fields may be temporary, but in the long run, workers may run out of viable work and long-term occupations. The obvious future of human jobs are most assured by those who can embrace the change through the design, development, installment, and maintenance of the technology. Younger workers can be re-educated while older humans can be re-trained. The goal of this paper is to explore all the forces that are enabling this revolution, investigating its many impacts, and speculating on the future of human jobs during nuclear remediation. Automation has made an impact to the manufacturing sector, and has since expanded to the retail and services sectors. The question is will this same automation transition, including robotics and artificial intelligence, occur to the environmental management and cleanup sector, and how should we prepare ourselves for this change. (author)

42 ENGINEERING↗

Emulation and detection of physical faults and cyber-attacks on building energy systems through real-time hardware-in-the-loop experiments

The increasing use of remote or mobile access, integrated wearable technologies, data exchange, and cloud-based data analytics in modern smart buildings is steering the building industry towards open communication technologies. The increased connectivity and accessibility could lead to more cyber-attacks in smart buildings. On the other hand, physical faults (e.g., HVAC -heating, ventilation, and air-conditioning faults) may have similar adverse impacts as those from the cyber-attacks on building energy systems, such as occupant discomfort, energy wastage, and equipment downtime. However, current physical behavior-based anomaly detection methods fail to differentiate between cyber-attacks and physical faults in building energy systems. Moreover, the challenge in collecting real-world threat data with ground truth has led researchers to rely on numerical models with user-defined assumptions, which may not accurately reflect real-world conditions due to the lack of in-situ experimental datasets. To address these challenges and gaps, this paper presents a flexible hardware-in-the-loop (HIL) testbed for generating cyber-attack and physical fault datasets and demonstrating threat detection algorithms in a real building automation system (BAS) environment. This testbed combines hardware (i.e., real BAS with local HVAC controllers and a physical network) with software (i.e., high-fidelity models to represent behaviors of building envelope and HVAC energy systems), enabling emulations of realistic threats. Five HIL experiments, including one baseline without any threats, two with physical faults, and two with cyber-attacks, were conducted to generate datasets containing detailed network traffic and system states. A joint classification framework, incorporating a network analyzer and a physical HVAC fault detector, was proposed to automatically detect cyber-physical abnormalities on BAS at both the network and the physical HVAC levels. The network analyzer comprises a conditional random fields (CRF) based command validator and a statistics-based detection strategy. The fault detector employs a weather and schedule-based pattern matching and feature-based principal component analysis (WPM-FPCA) method. Evaluation of the classification using four metrics from the multi-class confusion matrix revealed an average accuracy of 90.2%, recall of 89.7%, precision of 88.5% and F1-score of 89.2%. Finally, these results demonstrate that the proposed joint classification framework can effectively differentiate between specific types of cyber-attacks (e.g., device reinitialization attack, network Denial-of-Service attack) and physical faults (e.g., air handling unit operational fault, cooling coil valve stuck) in real time for improved building energy management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Industrial Hygiene Issues

This breakout session is a traditional conference instrument used by the NASA industrial hygiene personnel as a method to convene personnel across the Agency with common interests. This particular session focused on two key topics, training systems and automation of industrial hygiene data. During the FY 98 NASA Occupational Health Benchmarking study, the training system under development by the U.S. Environmental Protection Agency (EPA) was deemed to represent a "best business practice." The EPA has invested extensively in the development of computer based training covering a broad range of safety, health and environmental topics. Currently, five compact disks have been developed covering the topics listed: Safety, Health and Environmental Management Training for Field Inspection Activities; EPA Basic Radiation Training Safety Course; The OSHA 600 Collateral Duty Safety and Health Course; and Key program topics in environmental compliance, health and safety. Mr. Chris Johnson presented an overview of the EPA compact disk-based training system and answered questions on its deployment and use across the EPA. This training system has also recently been broadly distributed across other Federal Agencies. The EPA training system is considered "public domain" and, as such, is available to NASA at no cost in its current form. Copies of the five CD set of training programs were distributed to each NASA Center represented in the breakout session. Mr. Brisbin requested that each NASA Center review the training materials and determine whether there is interest in using the materials as it is or requesting that EPA tailor the training modules to suit NASA's training program needs. The Safety, Health and Medical Services organization at Ames Research Center has completed automation of several key program areas. Mr. Patrick Hogan, Safety Program Manager for Ames Research Center, presented a demonstration of the automated systems, which are described by the following: (1) Safety, Health and Environmental Training. This system includes an assessment of training needs for every NASA Center organization, course descriptions, schedules and automated course scheduling, and presentation of training program metrics; (2) Safety and Health Inspection Information. This system documents the findings from each facility inspection, tracks abatement status on those findings and presents metrics on each department for senior management review; (3) Safety Performance Evaluation Profile. The survey system used by NASA to evaluate employee and supervisory perceptions of safety programs is automated in this system; and (4) Documentation Tracking System. Electronic archive and retrieval of all correspondence and technical reports generated by the Safety, Health and Medical Services Office are provided by this system.

Brisbin, Steven G.↗

Northwest Open Automated Demand Response Technology Demonstration Project

Lawrence Berkeley National Laboratory (LBNL) and the Demand Response Research Center (DRRC) performed a technology demonstration and evaluation for Bonneville Power Administration (BPA) in Seattle City Light's (SCL) service territory. This report summarizes the process and results of deploying open automated demand response (OpenADR) in Seattle area with winter morning peaking commercial buildings. The field tests were designed to evaluate the feasibility of deploying fully automated demand response (DR) in four to six sites in the winter and the savings from various building systems. The project started in November of 2008 and lasted 6 months. The methodology for the study included site recruitment, control strategy development, automation system deployment and enhancements, and evaluation of sites participation in DR test events. LBNL subcontracted McKinstry and Akuacom for this project. McKinstry assisted with recruitment, site survey collection, strategy development and overall participant and control vendor management. Akuacom established a new server and enhanced its operations to allow for scheduling winter morning day-of and day-ahead events. Each site signed a Memorandum of Agreement with SCL. SCL offered each site $3,000 for agreeing to participate in the study and an additional $1,000 for each event they participated. Each facility and their control vendor worked with LBNL and McKinstry to select and implement control strategies for DR and developed their automation based on the existing Internet connectivity and building control system. Once the DR strategies were programmed, McKinstry commissioned them before actual test events. McKinstry worked with LBNL to identify control points that can be archived at each facility. For each site LBNL collected meter data and trend logs from the energy management and control system. The communication system allowed the sites to receive day-ahead as well as day-of DR test event signals. Measurement of DR was conducted using three different baseline models for estimation peak load reductions. One was three-in-ten baseline, which is based on the site electricity consumption from 7 am to 10 am for the three days with the highest consumption of the previous ten business days. The second model, the LBNL outside air temperature (OAT) regression baseline model, is based on OAT data and site electricity consumption from the previous ten days, adjusted using weather regressions from the fifteen-minute electric load data during each DR test event for each site. A third baseline that simply averages the available load data was used for sites less with less than 10 days of historical meter data. The evaluation also included surveying sites regarding any problems or issues that arose during the DR test events. Question covered occupant comfort, control issues and other potential problems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗