Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nonlinear optical microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

197 records · Page 11

Energetics at the Surface: Direct Optical Mapping of Core and Surface Electronic Structure in CdSe Quantum Dots Using Broadband Electronic Sum Frequency Generation Microspectroscopy

Understanding and controlling the electronic structure of nanomaterials is the key to tailoring their use in a wide range of practical applications. Despite this need, many important electronic states are invisible to conventional optical measurements and are typically identified indirectly based on their inferred impact on luminescence properties. This is especially common and important in the study of nanomaterial surfaces and their associated defects. Surface trap states play a crucial role in photophysical processes yet remain remarkably poorly understood. In this work we demonstrate for the first time that broadband electronic sum frequency generation (eSFG) microspectroscopy can directly map the optically bright and dark states of nanoparticles, including the elusive below gap states. This new approach is applied to model cadmium selenide (CdSe) quantum dots (QDs), where the energies of surface trap states have eluded direct optical characterization for decades. Our eSFG measurements show clear signatures of electronic transitions both above the band gap, which we assign to previously reported one- and two-photon transitions associated with the CdSe core, as well as broad spectral signatures below the band gap that are attributed to surface states. In addition to the core states, this analysis reveals two distinct distributions of below gap states, providing the first direct optical measurement of both shallow and deep surface states on this system. Lastly, chemical modification of the surfaces via oxidation results in the relative increase in the signals originating from the surface states. Overall, our eSFG experiments provide an avenue to directly map the entirety of the QD core and surface electronic structure, which is expected to open up opportunities to study how these materials are grown in situ and how surface states can be controlled to tune functionality.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Thermomechanical Fatigue Durability of T650-35/PMR-15 Sheet Molding Compound

Although polyimide based composites have been used for many years in a wide variety of elevated temperature applications, very little work has been done to examine the durability and damage behavior under more prototypical thermomechanical fatigue (TMF) loadings. Synergistic effects resulting from simultaneous temperature and load cycling can potentially lead to enhanced, if not unique, damage modes and contribute to a number of nonlinear deformation responses. The goal of this research was to examine the effects of a TMF loading spectrum, representative of a gas turbine engine compressor application, on a polyimide sheet molding compound (SMC). High performance SMCs present alternatives to prepreg forms with great potential for low cost component production through less labor intensive, more easily automated manufacturing. To examine the issues involved with TMF, a detailed experimental investigation was conducted to characterize the durability of a T650-35/PMR-15 SMC subjected to TMF mission cycle loadings. Fatigue damage progression was tracked through macroscopic deformation and elastic stiffness. Additional properties, such as the glass transition temperature (T(sub g) and dynamic mechanical properties were examined. The fiber distribution orientation was also characterized through a detailed quantitative image analysis. Damage tolerance was quantified on the basis of residual static tensile properties after a prescribed number of TMF missions. Detailed microstructural examinations were conducted using optical and scanning electron microscopy to characterize the local damage. The imposed baseline TMF missions had only a modest impact on inducing fatigue damage with no statistically significant degradation occurring in the measured macroscopic properties. Microstructural damage was, however, observed subsequent to 100 h of TMF cycling which consisted primarily of fiber debonding and transverse cracking local to predominantly transverse fiber bundles. The TMF loadings did introduce creep related effects (strain accumulation) which led to rupture in some of the more aggressive stress scenarios examined. In some cases this creep behavior occurred at temperatures in excess of 150 C below commonly cited values for T(sub g). Thermomechanical exploratory creep tests revealed that the SMC was subject to time dependent deformation at stress/temperature thresholds of 150 MPa/230 C and 170 MPa/180 C.

Castelli, Michael G.↗

Femtosecond wavelength-tunable laser system using gain managed nonlinear amplifier

Optical parametric amplifiers require a seed energy at the spectral range of interest for amplification. In the case of pulsed laser systems, seed pulse characteristics such as spectral energy density and spectral uniformity influence laser system design and performance. In this letter, we present the design and modeling of a few micro-joules, wavelength-tunable, femtosecond parametric amplifier system. We employ a gain-managed nonlinear fiber amplifier output as the seed pulse. This seed pulse is relatively uniform across its bandwidth from 1010 to 1180 nm. Its spectral energy density averages 600 pJ/nm, 30 times higher than conventional counterparts. The overall amplification gain is 175, and the conversion efficiency is 17.5%. The inherent quasi-linear chirp of the seed pulse is utilized to alter the output wavelength. Our tunable femtosecond laser is an enabling technology for high-demand applications such as time-resolved spectroscopy, nonlinear and advanced material research, and biomedical imaging and microscopy modalities.

47 OTHER INSTRUMENTATION↗

Ferroelectric and Charge Transport Properties in Strain-Engineered Two-Dimensional Lead Iodide Perovskites

Transitions from three-dimensional (3D) hybrid organic–inorganic perovskite (HOIP) structures to lower dimensions including 2D and quasi-2D structures open a new range of functional properties in these materials systems. Yet, the performance of solar cells made from 2D HOIP is below that of the 3D compositions due to the higher band-gap energy, low carrier concentration, and anisotropy in charge transport. Controlling ferroelectricity in 2D HOIPs is considered to be a powerful strategy to drive the spatial separation of photogenerated charge carriers to improve the photovoltaic action in this class of HOIPs. Here, we explore the strain-dependent ferroelectricity and charge carrier properties in strain-engineered 2D-layered HOIPs utilizing advanced scanning probe microscopy (SPM) techniques. Band excitation-piezoresponse force microscopy (BE-PFM) and contact Kelvin probe force microscopy (cKPFM) reveal ferroelectric domains and switchable dynamics with significantly low switching voltages in the low-strain film. Photoluminescence (PL) spectroscopy shows strain-dependent optical properties and a noncentrosymmetric structure with strong second-harmonic generation (SHG) peaks in the low-strain film. In addition, KPFM results demonstrate a higher surface potential in the low-strain films, while the photovoltage and local current are the highest on the high-strain film. Furthermore, our study demonstrates the critical role of strain engineering on the electromechanical and charge carrier dynamics in 2D HOIPs, which is important for development of 2D HOIP devices.

36 MATERIALS SCIENCE↗

Peculiar Magnetic and Magneto-Transport Properties in a Noncentrosymmetric Self-Intercalated van der Waals Ferromagnet Cr 5 Te 8

Trigonal Cr 5 Te 8 , a self-intercalated van der Waals ferromagnet with an out-of-plane magnetic anisotropy, has long been known to crystallize in a centrosymmetric structure. However, optical second harmonic generation experiments, together with comprehensive structural analysis, indicate that this compound rather adopts a noncentrosymmetric structure. Lorentz transmission electron microscopy reveals the presence of Néel-type skyrmions, consistent with its noncentrosymmetric structure. A large anomalous Hall conductivity of 102 Ω –1 cm –1 at low temperature stems from intrinsic origin, which is larger than any previously reported values in the bulk Cr–Te system. Notably, spontaneous topological Hall resistivity arising from the skyrmionic phase has been observed. Here, our findings not only elucidate the unique magnetic and magneto-transport properties of noncentrosymmetric trigonal Cr 5 Te 8 , but also open new avenues for investigating the effects of broken inversion symmetry on material properties and their potential applications.

crystal structure↗

Applications of Subsurface Microscopy

Exploring the interior of a cell is of tremendous importance in order to assess the effects of nanomaterials on biological systems. Outside of a controlled laboratory environment, nanomaterials will most likely not be conveniently labeled or tagged so that their translocation within a biological system cannot be easily identified and quantified. Ideally, the characterization of nanomaterials within a cell requires a nondestructive, label-free, and subsurface approach. Subsurface nanoscale imaging represents a real challenge for instrumentation. Indeed the tools available for high resolution characterization, including optical, electron or scanning probe microscopies, mainly provide topography images or require tagants that fluoresce. Although the intercellular environment holds a great deal of information, subsurface visualization remains a poorly explored area. Recently, it was discovered that by mechanically perturbing a sample, it was possible to observe its response in time with nanoscale resolution by probing the surface with a micro-resonator such as a microcantilever probe (Figure 1). Microcantilevers are used as the force-sensing probes in Atomic Force Microscopy (AFM), where the nanometer-scale probe tip on the microcantilever interacts with the sample in a highly controlled manner to produce high-resolution raster-scanned information of the sample surface. Taking advantage of the existing capabilities of AFM, we present a novel technique, Mode Synthesizing Atomic Force Microscopy (MSAFM) (Figure 1), which has the ability to probe subsurface structures such as non-labeled nanoparticles embedded in a cell. In MSAFM mechanical actuators (PZTs) excite the probe and the sample at different frequencies as depicted in Figure 1. The nonlinear nature of the tip-sample interaction, at the point of contact of the probe and the surface of the sample, in the contact mode AFM configuration permits the mixing of the elastic waves. The new dynamic system comprises new synthesized imaging modes, resulting from sum- and difference-frequency generation of the driving frequencies. The specific electronics of MSAFM allows the selection of individual modes and the monitoring of their amplitude and phase. From these quantities of various synthesized modes a series of images can be acquired. The new images contain subsurface information, thus revealing the presence of nanoparticles inside the cells.

Tetard, Laurene↗

Vapor transport growth of organic solids in microgravity and unit gravity: some comparisons and results to date

Thin films of an organic nonlinear optical (NLO) material, N, N-dimethyl-p-(2,2-dicyanovinyl) aniline (DCVA), have been grown in space and on the ground by physical vapor transport in an effusive ampoule arrangement. The thin film growth technique developed on the ground is a direct result of information gleaned from experiments in microgravity. This paper covers the results of our experimental investigations for establishing "ideal" terrestrial conditions for deposition of a DCVA film. The active control during the deposition process was exercised by three deposition variables: the material source temperature, the background pressure external to the growth ampoule and the substrate temperature. Successful growth occurred when the difference in temperature between the source material and the copper substrate was 14 degrees C and the background nitrogen pressure was such that the transport was either diffusive or convective. A qualitative diffusion limited boundary was estimated to occur at a pressure of approximately 20 torr. We have probed the DCVA thin films with visible-near infrared reflection absorption spectroscopy, polarized Fourier transform infrared spectrometry, differential interference contrast optical microscopy, and stylus profilometry.

short duration↗

Dynamic near-field optical interaction between oscillating nanomechanical structures

Near-field optical techniques exploit light-matter interactions at small length scales for mechanical sensing and actuation of nanomechanical structures. Here, we study the optical interaction between two mechanical oscillators—a plasmonic nanofocusing probe-tip supported by a low frequency cantilever, and a high frequency nanomechanical resonator—and leverage their interaction for local detection of mechanical vibrations. The plasmonic nanofocusing probe provides a confined optical source to enhance the interaction between the two oscillators. Dynamic perturbation of the optical cavity between the probe-tip and the resonator leads to nonlinear modulation of the scattered light intensity at the sum and difference of their frequencies. This double-frequency demodulation scheme is explored to suppress unwanted background and to detect mechanical vibrations with a minimum detectable displacement sensitivity of 0.45pm/Hz 1/2 , which is limited by shot noise and electrical noise. We explore the demodulation scheme for imaging the bending vibration mode shape of the resonator with a lateral spatial resolution of 20nm. We also demonstrate the time-resolved aspect of the local optical interaction by recording the ring-down vibrations of the resonator at frequencies of up to 129MHz. The near-field optical technique is promising for studying dynamic mechanical processes in individual nanostructures.

36 MATERIALS SCIENCE↗

Enhancing the Range and Reliability of the Spacer Layer Imaging Method

The spacer layer imaging method (SLIM) is widely used to measure the thickness of additive and lubricant films, in lubricant development and evaluation, and for fundamental research into elastohydrodynamic lubrication and tribofilm formation mechanisms. The film thickness measurement, as implemented on several popular tribometers, provides powerful, non-destructive in-situ mapping of film topography with nanometre-scale height sensitivity. However, the results can be highly sensitive to experimental procedure, machine condition, and image analysis, in some cases reporting unphysical film thickness trends. The prevailing image analysis techniques make it challenging to interrogate these errors, often hiding their multivariate nonlinear behaviour from the user by spatial averaging. Herein, several common ‘silent errors’ in the SLIM measurement, including colour matching to incorrect fringe orders, and colour drift due to the optical properties of the system or film itself, are discussed, with examples. A robust suite of novel a priori and a posteriori methods to address these issues, and to improve the accuracy and reliability of the measurement, are also presented, including a novel, computationally inexpensive circle-finding algorithm for automated image processing. In combination, these methods allow reliable mapping of films up to at least 800 nm in thickness, representing a significant milestone for the utility of SLIM applied to elastohydrodynamic contact.

EHL film geometry↗

A metrological large range atomic force microscope with improved performance

A metrological large range atomic force microscope (Met. LR-AFM) has been set up and improved over the past years at Physikalisch-Technische Bundesanstalt (PTB). Being designed as a scanning sample type instrument, the sample is moved in three dimensions by a mechanical ball bearing stage in combination with a compact z-piezostage. Its topography is detected by a position-stationary AFM head. The sample displacement is measured by three embedded miniature homodyne interferometers in the x, y, and z directions. The AFM head is aligned in such a way that its cantilever tip is positioned on the sample surface at the intersection point of the three interferometer measurement beams for satisfying the Abbe measurement principle. In this paper, further improvements of the Met. LR-AFM are reported. A new AFM head using the beam deflection principle has been developed to reduce the influence of parasitic optical interference phenomena. Furthermore, an off-line Heydemann correction method has been applied to reduce the inherent interferometer nonlinearities to less than 0.3 nm (p-v). Versatile scanning functions, for example, radial scanning or local AFM measurement functions, have been implemented to optimize the measurement process. The measurement software is also improved and allows comfortable operations of the instrument via graphical user interface or script-based command sets. The improved Met. LR-AFM is capable of measuring, for instance, the step height, lateral pitch, line width, nanoroughness, and other geometrical parameters of nanostructures. Calibration results of a one-dimensional grating and a set of film thickness standards are demonstrated, showing the excellent metrological performance of the instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrafast-induced coherent acoustic phonons in the two-dimensional magnet CrSBr

Magnetism in two-dimensional (2D) van der Waals (vdW) crystals offers promising new directions for low-dimensional physics and devices. In this work, mega-electron volt (MeV) ultrafast electron diffraction was employed to investigate the ultrafast atomic dynamics of a novel, 2D vdW magnetic single-crystal CrSBr. Femtosecond (fs) optical pump pulses excited non-equilibrium atomic displacements shown to be coherent acoustic phonons (CAPs). Phonon frequencies were extracted by analyzing oscillations of different Bragg peak (BP) intensities and were determined to be GHz acoustic disturbances that propagated as strain waves. Phonon modes exhibit anisotropy with respect to the a and b crystal axes. Subharmonic phonon frequencies were also observed, and this provided a signature of nonlinear oscillatory coupling between the laser-induced pumping phonon frequency and secondary phonon frequencies. Thus, CrSBr was found to serve as a nonlinear phononic frequency converter. The ultrafast time dependence of the Bragg intensity was simulated by incorporating an oscillating deviation parameter ansatz into expressions for the dynamical scattering intensity yielded excellent modeling of the ultrafast structural dynamics of the photo-excited 2D crystal. Our work provides a foundation for exploring how fs light pulses can influence phonon dynamics in materials with strong spin-lattice coupling. These results suggest that CAPs can match the magnon frequencies and show the promise of CrSBr for use in optical-to-microwave transducers and phononic devices.

43 PARTICLE ACCELERATORS↗

Tunable Plasma Linearizer for Compensation of Nonlinear Energy Chirp

The removal of undesired nonlinear time-energy correlation (energy chirp) present in relativistic electron beams is crucial for many accelerator-based scientific applications, such as free-electron lasers, high-energy electron radiography, and MeV ultrafast electron microscopy. Here, we propose and demonstrate that a low-density plasma section can be used as a passive “linearizer” to significantly compensate for the nonlinear energy chirp imprinted on a beam by the curvature of the radio-frequency field in a conventional accelerator. Physically, the passage of the beam through the plasma excites a strong quasi-cosinoidal longitudinal decelerating wakefield that acts to mitigate the beam’s nonlinear energy chirp by superimposing a reverse chirp on the beam. Time-resolved phase-space measurements, combined with high-fidelity three-dimensional particle-in-cell simulations show that the longitudinal phase space of the beam core is almost completely linearized, leading to a fourfold reduction of the beam overall energy spread from 0.148% to 0.036% (FWHM).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Second Harmonic Generation Guided Raman Spectroscopy for Sensitive Detection of Polymorph Transitions

Second harmonic generation (SHG) was integrated with Raman spectroscopy for the analysis of pharmaceutical materials. Particulate formulations of clopidogrel bisulfate were prepared in two crystal forms (Form I and Form II). Image analysis approaches enable automated identification of particles by bright field imaging, followed by classification by SHG. Quantitative SHG microscopy enabled discrimination of crystal form on a per particle basis with 99.95% confidence in a total measurement time of ~10 ms per particle. Complementary measurements by Raman and synchrotron XRD are in excellent agreement with the classifications made by SHG, with measurement times of ~1 min and several seconds per particle, respectively. In conclusion, coupling these capabilities with at-line monitoring may enable real-time feedback for reaction monitoring during pharmaceutical production to favor the more bioavailable but metastable Form I with limits of detection in the ppm regime.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New oxyfluoride glass with high fluorine content and laser patterning of nonlinear optical BaAlBO{sub 3}F{sub 2} single crystal line

A new oxyfluoride glass of 50BaF{sub 2}-25Al{sub 2}O{sub 3}-25B{sub 2}O{sub 3} (mol. %) with a large fraction of fluorine, i.e., F/(F + O) = 0.4, was prepared using a conventional melt-quenching method in order to synthesize new glass-ceramics containing nonlinear optical oxyfluoride crystals. The refractive index at 632.8 nm and ultra-violet cutoff wavelength of the glass were 1.564 and {approx}200 nm, respectively. Eu{sup 3+} ions in the glass showed a high quantum yield of 88% in the photoluminescence spectrum in the visible region. BaAlBO{sub 3}F{sub 2} crystals (size: 50-100 nm) showing second harmonic generations were formed through the crystallization of the glass. Lines consisting of BaAlBO{sub 3}F{sub 2} crystals were patterned successfully on the glass surface by laser irradiations (Yb:YVO{sub 4} laser with a wavelength of 1080 nm, laser power of 1.1 W, scanning speed of 8 {mu}m/s). High resolution transmission electron microscope observations combined with a focused ion beam technique indicate that BaAlBO{sub 3}F{sub 2} crystals are highly oriented just like a single crystal. The present study proposes that the new oxyfluoride glass and glass-ceramics prepared have a high potential for optical device applications.

36 MATERIALS SCIENCE↗

A two-axis in-plane motion measurement system based on optical beam deflection

Measurement of in-plane motion with high resolution and large bandwidth enables model-identification and real-time control of motion-stages. This paper presents an optical beam deflection based system for measurement of in-plane motion of both macro- and micro-scale motion stages. A curved reflector is integrated with the motion stage to achieve sensitivity to in-plane translational motion along two axes. Under optimal settings, the measurement system is shown to theoretically achieve sub-angstrom measurement resolution over a bandwidth in excess of 1 kHz and negligible cross-sensitivity to linear motion. Subsequently, the proposed technique is experimentally demonstrated by measuring the in-plane motion of a piezo flexure stage and a scanning probe microcantilever. For the former case, reflective spherical balls of different radii are employed to measure the in-plane motion and the measured sensitivities are shown to agree with theoretical values, on average, to within 8.3%. For the latter case, a prototype polydimethylsiloxane micro-reflector is integrated with the microcantilever. The measured in-plane motion of the microcantilever probe is used to identify nonlinearities and the transient dynamics of the piezo-stage upon which the probe is mounted. These are subsequently compensated by means of feedback control.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LLE Review 114 (January-March 2008)

This volume of the LLE Review, covering January-March 2008, features 'Cryogenic Targets: Current Status and Future Development', by D. R. Harding, D. H. Edgell, M. D. Wittman, L. M. Elasky, S. J. Verbridge, A. J. Weaver, L. D. Lund, W. Seka, W. T. Shmayda, R. T. Janezic, M. J. Shoup III, M. Moore, R. Junquist, and A. V. Okishev. In this article (p. 57), the authors report on the status of layering cryogenic DT and D{sub 2} targets at LLE for inertial confinement fusion (ICF) targets. This critical effort achieves the important milestone of routinely providing cryogenic DT targets that meet the 1.0-{micro}m (rms) OMEGA ice-quality-surface specification. The best D{sub 2}-ice layers produced so far (rms roughness of 1.1 {micro}m) are approaching the quality typically achieved in DT targets. Efforts to improve the consistency of this process are reported along with investigations supporting the National Ignition Campaign studying issues relevant to indirect-drive and direct-drive cryogenic targets. Additional highlights of recent research presented in this issue include the following: (1) an improved laser speckle smoothing scheme that augments the current NIF 1-D SSD system by using multiple-FM modulators (MultiFM 1-D SSD) (p. 73). With a judicious choice of modulator frequencies, MultiFM 1-D SSD smoothes resonances produced at the higher spatial frequencies and can attain similar or even faster smoothing rates compared to the baseline NIF 2-D SSD system. DRACO simulations have shown that MultiFM 1-D SSD beam smoothing is sufficient for the direct-drive-ignition targets and pulse shapes analyzed thus far, and may even allow reducing the bandwidth enough to eliminate the need for dual-tripler frequency conversion on the NIF. (2) describes a time-gated, monoenergetic proton radiography that provides unique measurements of implosion dynamics of spherical targets in direct-drive inertial confinement fusion (ICF) (p. 81). Radiographs obtained at different implosion times, from acceleration, through coasting, deceleration, to final stagnation, display a comprehensive picture of spherical ICF implosion. Critical information inferred from such images characterizes the spatial structure and temporal evolution of self-generated fields and plasma areal density. (3) describes a single-shot cross-correlator based on a pulse replicator that produces a discrete sequence of sampling pulses that are nonlinearly mixed with the pulse under test (p. 86). The combination of a high reflector and partial reflector replicates an optical pulse by multiple internal reflections and generates a sequence of spatially displaced and temporally delayed sampling pulses. This principle is used in a cross-correlator characterizing optical pulses at 1053 nm, where a dynamic range higher than 60 dB is obtained over a temporal range larger than 200 ps. The dynamic range can be extended with standard optical-density filters and the temporal range extended with larger optics. (4) presents a novel focal-spot diagnostic developed for OMEGA EP that will be used to characterize on-shot focal spots to support high-quality laser-matter interaction experiments (p. 94). The complex fields in the region of the high-energy focus are calculated using high-resolution measurements of the main beam wavefront using the focal-spot diagnostic (FSD) located on the short-pulse diagnostic package and a careful calibration of the transfer wavefront between the FSD instrument and target chamber center. The concept of this calibration procedure is experimentally verified in the Multi-Terawatt (MTW) Laser System, which serves as a development platform for OMEGA EP. A technique based on phase retrieval is employed for the transfer-wavefront calibration since the OMEGA EP infrastructure cannot be replicated in the MTW laser; however, this approach also shows promise as an alternative method for OMEGA EP. (5) report on a systematic study to improve the laser-damage resistance of multilayer high-reflector coatings for use at 351 nm on the OMEGA EP Laser System (p. 103). A series of ha

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗