Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “motion planning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Relationship of Imaging Frequency and Planning Margin to Account for Intrafraction Prostate Motion: Analysis Based on Real-Time Monitoring Data

Purpose: Correction for intrafraction prostate motion becomes important for hypofraction treatment of prostate cancer. The purpose of this study was to estimate an ideal planning margin to account for intrafraction prostate motion as a function of imaging and repositioning frequency in the absence of continuous prostate motion monitoring. Methods and Materials: For 31 patients receiving intensity modulated radiation therapy treatment, prostate positions sampled at 10 Hz during treatment using the Calypso system were analyzed. Using these data, we simulated multiple, less frequent imaging protocols, including intervals of every 10, 15, 20, 30, 45, 60, 90, 120, 180, and 240 seconds. For each imaging protocol, the prostate displacement at the imaging time was corrected by subtracting prostate shifts from the subsequent displacements in that fraction. Furthermore, we conducted a principal component analysis to quantify the direction of prostate motion. Results: Averaging histograms of every 240 and 60 seconds for all patients, vector displacements of the prostate were, respectively, within 3 and 2 mm for 95% of the treatment time. A vector margin of 1 mm achieved 91.2% coverage of the prostate with 30 second imaging. The principal component analysis for all fractions showed the largest variance in prostate position in the midsagittal plane at 54° from the anterior direction, indicating that anterosuperior to inferoposterior is the direction of greatest motion. The smallest prostate motion is in the left-right direction. Conclusions: The magnitudes of intrafraction prostate motion along the superior-inferior and anterior-posterior directions are comparable, and the smallest motion is in the left-right direction. In the absence of continuous prostate motion monitoring, and under ideal circumstances, 1-, 2-, and 3-mm vector planning margins require a respective imaging frequency of every 15, 60, and 240 to account for intrafraction prostate motion while achieving adequate geometric target coverage for 95% of the time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-622: Planning Technique for Passively-Scattered Involved-Node Proton Therapy of Mediastinal Lymphoma with Consideration of Cardiac Motion

Purpose: To develop a treatment planning method for passively-scattered involved-node proton therapy of mediastinal lymphoma robust to breathing and cardiac motions. Methods: Beam-specific planning treatment volumes (bsPTV) are calculated for each proton field to incorporate pertinent uncertainties. Geometric margins are added laterally to each beam while margins for range uncertainty due to setup errors, breathing, and calibration curve uncertainties are added along each beam. The calculation of breathing motion and deformation effects on proton range includes all 4DCT phases. The anisotropic water equivalent margins are translated to distances on average 4DCT. Treatment plans are designed so each beam adequately covers the corresponding bsPTV. For targets close to the heart, cardiac motion effects on dosemaps are estimated by using a library of anonymous ECG-gated cardiac CTs (cCT). The cCT, originally contrast-enhanced, are partially overridden to allow meaningful proton dose calculations. Targets similar to the treatment targets are drawn on one or more cCT sets matching the anatomy of the patient. Plans based on the average cCT are calculated on individual phases, then deformed to the average and accumulated. When clinically significant dose discrepancies occur between planned and accumulated doses, the patient plan is modified to reduce the cardiac motion effects. Results: We found that bsPTVs as planning targets create dose distributions similar to the conventional proton planning distributions, while they are a valuable tool for visualization of the uncertainties. For large targets with variability in motion and depth, integral dose was reduced because of the anisotropic margins. In most cases, heart motion has a clinically insignificant effect on target coverage. Conclusion: A treatment planning method was developed and used for proton therapy of mediastinal lymphoma. The technique incorporates bsPTVs compensating for all common sources of uncertainties and estimation of the effects of cardiac motion not commonly performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostate and Patient Intrafraction Motion: Impact on Treatment Time-Dependent Planning Margins for Patients With Endorectal Balloon

Purpose: To investigate intrafraction prostate and patient motion during different radiation therapy treatments as a function of treatment time; included were prostate patients with an endorectal balloon (ERB). Margins accounting for setup uncertainties and intrafraction motion were determined. Methods and Materials: The study included 17 patients undergoing prostate cancer radiation therapy. All patients received 3 fiducial gold markers implanted in the prostate and were then immobilized in the supine position with a knee support and treated with an ERB. Twelve patients with intermediate risk for pelvic lymph node metastases received intensity modulated radiation therapy (IMRT), and 5 patients at low risk received a 4-field box treatment. After setup based on skin marks, patients were imaged with a stereoscopic imaging system. If the marker displacement exceeded a 3-mm tolerance relative to planning computed tomography, patients were shifted and verification images were taken. All patients underwent additional imaging after treatment; IMRT patients also received additional imaging at halftime of treatment. Prostate and bone drifts were evaluated as a function of treatment time for more than 600 fractions, and margins were extracted. Results: Patient motion evaluated by bone match was strongly patient dependent but in general was smallest in the superior-inferior (SI) direction. Prostate drifts were less patient dependent, showing an increase with treatment time in the SI and anterior-posterior (AP) directions. In the lateral (LAT) direction, the prostate stayed rather stable. Mean treatment times were 5.5 minutes for 4-field box, 10 minutes for 5-field boost IMRT, and 15 minutes or more for 9-field boost and 9-field pelvic IMRT treatments. Margins resulted in 2.2 mm, 3.9 mm, and 4.3 mm for 4-field box; 3.7 mm, 2.6 mm, and 3.6 mm for 5-field boost IMRT; 2.3 mm, 3.9 mm, and 6.2 mm for 9-field boost IMRT; and 4.2 mm, 5.1 mm, and 6.6 mm for 9-field pelvic IMRT in the LAT, SI, and AP directions, respectively. Conclusion: Intrafraction prostate and patient displacement increased with treatment time, showing different behaviors for the single directions of movement. Repositioning of the patients during long treatments or shorter treatment times will be necessary to further reduce the treatment margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tumor trailing strategy for intensity-modulated radiation therapy of moving targets

Internal organ motion during the course of radiation therapy of cancer affects the distribution of the delivered dose and, generally, reduces its conformality to the targeted volume. Previously proposed approaches aimed at mitigating the effect of internal motion in intensity-modulated radiation therapy (IMRT) included expansion of the target margins, motion-correlated delivery (e.g., respiratory gating, tumor tracking), and adaptive treatment plan optimization employing a probabilistic description of motion. We describe and test the tumor trailing strategy, which utilizes the synergy of motion-adaptive treatment planning and delivery methods. We regard the (rigid) target motion as a superposition of a relatively fast cyclic component (e.g., respiratory) and slow aperiodic trends (e.g., the drift of exhalation baseline). In the trailing approach, these two components of motion are decoupled and dealt with separately. Real-time motion monitoring is employed to identify the 'slow' shifts, which are then corrected by applying setup adjustments. The delivery does not track the target position exactly, but trails the systematic trend due to the delay between the time a shift occurs, is reliably detected, and, subsequently, corrected. The ''fast'' cyclic motion is accounted for with a robust motion-adaptive treatment planning, which allows for variability in motion parameters (e.g., mean and extrema of the tidal volume, variable period of respiration, and expiratory duration). Motion-surrogate data from gated IMRT treatments were used to provide probability distribution data for motion-adaptive planning and to test algorithms that identified systematic trends in the character of motion. Sample IMRT fields were delivered on a clinical linear accelerator to a programmable moving phantom. Dose measurements were performed with a commercial two-dimensional ion-chamber array. The results indicate that by reducing intrafractional motion variability, the trailing strategy enhances relevance and applicability of motion-adaptive planning methods, and improves conformality of the delivered dose to the target in the presence of irregular motion. Trailing strategy can be applied to respiratory-gated treatments, in which the correction for the slow motion can increase the duty cycle, while robust probabilistic planning can improve management of the residual motion within the gate window. Similarly, trailing may improve the dose conformality in treatment of patients who exhibit detectable target motion of low amplitude, which is considered insufficient to provide a clinical indication for the use of respiratory-gated treatment (e.g., peak-to-peak motion of less than 10 mm). The mechanical limitations of implementing tumor trailing are less rigorous than those of real-time tracking, and the same technology could be used for both.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low-Frequency Seismic Ground Motion At The Pier Positions Of The Planned Messina Straits Bridge For A Realistic Earthquake Scenario

We estimated longer-period (period T>0.5 s) components of the ground motion at the piers of the planned Messina straits bridge. As the shortest fault-to-site distance is only 3-5 km, the kinematic earthquake rupture process has to be described in a realistic way and thus, the causative fault is represented by a dense grid of subfaults. To model the 1908 event, we assume a Mw = 7 earthquake, with a 40x20 km rectangular fault, and pure reverse dip-slip. The horizontal upper side of the rectangle is at 3-km depth, and the N corner of the rectangle is just between the piers. For the fault nucleation point, the least favorable place is assumed and a randomized rupture velocity is used in a particular run. In a typical simulation, the fault motion is initially represented by the time history of slip in each of the subfaults and by the distribution of the final seismic moment among the subsources (forming 'asperities'), both generated as lognormal random functions. The time histories are then filtered in order to fit a chosen source spectral model. The parameters that are conditioning the random functions can be based on the bulk of published fault inversions, or reproduced from an earlier successful attempt to simulate ground motions in the epicentral zone of the 1994, M = 6.7 Northridge, California, earthquake. In the second step of calculations, the Green functions (for each subfault and pier combination) are calculated for a layered halfspace model of the pier foundation stratigraphy, using an advanced Green function calculator, that allows an accurate calculation over the entire relevant frequency band including static terms. Finally, the 3-components of the strong ground motion are obtained at the two piers through convolution and summation over the different subsources. We compare a set of response horizontal velocity spectra (PRV) obtained from our calculations with a reference PRV that is considered as a reasonable upper bound for the possible ground motion near the piers. Our results suggest that the seismic ground motion under Torre Sicilia dominates over this under Torre Calabria and that the median (average log) PRV is generally above the reference one, about 1.1-1.3 times for T>4 s, and up to 2 times for 1<T{<=}4 s. The use of advanced fault and medium models, accounting also for the natural scatter of individual PRV due to events with the same gross source parameters, provides a sound basis for the deterministic engineering estimates of future seismic ground motion.

58 GEOSCIENCES↗

TU-CD-304-01: FEATURED PRESENTATION and BEST IN PHYSICS (THERAPY): Trajectory Modulated Arc Therapy: Development of Novel Arc Delivery Techniques Integrating Dynamic Table Motion for Extended Volume Treatments

Purpose: Integration of coordinated robotic table motion with inversely-planned arc delivery has the potential to resolve table-top delivery limitations of large-field treatments such as Total Body Irradiation (TBI), Total Lymphoid Irradiation (TLI), and Cranial-Spinal Irradiation (CSI). We formulate the foundation for Trajectory Modulated Arc Therapy (TMAT), and using Varian Developer Mode capabilities, experimentally investigate its practical implementation for such techniques. Methods: A MATLAB algorithm was developed for inverse planning optimization of the table motion, MLC positions, and gantry motion under extended-SSD geometry. To maximize the effective field size, delivery trajectories for TMAT TBI were formed with the table rotated at 270° IEC and dropped vertically to 152.5cm SSD. Preliminary testing of algorithm parameters was done through retrospective planning analysis. Robotic delivery was programmed using custom XML scripting on the TrueBeam Developer Mode platform. Final dose was calculated using the Eclipse AAA algorithm. Initial verification of delivery accuracy was measured using OSLDs on a solid water phantom of varying thickness. Results: A comparison of DVH curves demonstrated that dynamic couch motion irradiation was sufficiently approximated by static control points spaced in intervals of less than 2cm. Optimized MLC motion decreased the average lung dose to 68.5% of the prescription dose. The programmed irradiation integrating coordinated table motion was deliverable on a TrueBeam STx linac in 6.7 min. With the couch translating under an open 10cmx20cm field angled at 10°, OSLD measurements along the midline of a solid water phantom at depths of 3, 5, and 9cm were within 3% of the TPS AAA algorithm with an average deviation of 1.2%. Conclusion: A treatment planning and delivery system for Trajectory Modulated Arc Therapy of extended volumes has been established and experimentally demonstrated for TBI. Extension to other treatment techniques such as TLI and CSI is readily achievable through the developed platform. Grant Funding by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Technical Note: A novel leaf sequencing optimization algorithm which considers previous underdose and overdose events for MLC tracking radiotherapy

Purpose: Multileaf collimator (MLC) tracking radiotherapy is complex as the beam pattern needs to be modified due to the planned intensity modulation as well as the real-time target motion. The target motion cannot be planned; therefore, the modified beam pattern differs from the original plan and the MLC sequence needs to be recomputed online. Current MLC tracking algorithms use a greedy heuristic in that they optimize for a given time, but ignore past errors. To overcome this problem, the authors have developed and improved an algorithm that minimizes large underdose and overdose regions. Additionally, previous underdose and overdose events are taken into account to avoid regions with high quantity of dose events. Methods: The authors improved the existing MLC motion control algorithm by introducing a cumulative underdose/overdose map. This map represents the actual projection of the planned tumor shape and logs occurring dose events at each specific regions. These events have an impact on the dose cost calculation and reduce recurrence of dose events at each region. The authors studied the improvement of the new temporal optimization algorithm in terms of the L1-norm minimization of the sum of overdose and underdose compared to not accounting for previous dose events. For evaluation, the authors simulated the delivery of 5 conformal and 14 intensity-modulated radiotherapy (IMRT)-plans with 7 3D patient measured tumor motion traces. Results: Simulations with conformal shapes showed an improvement of L1-norm up to 8.5% after 100 MLC modification steps. Experiments showed comparable improvements with the same type of treatment plans. Conclusions: A novel leaf sequencing optimization algorithm which considers previous dose events for MLC tracking radiotherapy has been developed and investigated. Reductions in underdose/overdose are observed for conformal and IMRT delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

Impact of Intrafraction and Residual Interfraction Effect on Prostate Proton Pencil Beam Scanning

Purpose: To quantitatively evaluate the impact of interplay effect and plan robustness associated with intrafraction and residual interfraction prostate motion for pencil beam scanning proton therapy. Methods and Materials: Ten prostate cancer patients with weekly verification CTs underwent pencil beam scanning with the bilateral single-field uniform dose (SFUD) modality. A typical field had 10-15 energy layers and 500-1000 spots. According to their treatment logs, each layer delivery time was <1 s, with average time to change layers of approximately 8 s. Real-time intrafraction prostate motion was determined from our previously reported prospective study using Calypso beacon transponders. Prostate motion and beam delivering sequence of the worst-case scenario patient were synchronized to calculate the “true” dose received by the prostate. The intrafraction effect was examined by applying the worst-case scenario prostate motion on the planning CT, and the residual interfraction effect was examined on the basis of weekly CT scans. The resultant dose variation of target and critical structures was examined to evaluate the interplay effect. Results: The clinical target volume (CTV) coverage was degraded because of both effects. The CTV D{sub 99} (percentage dose to 99% of the CTV) varied up to 10% relative to the initial plan in individual fractions. However, over the entire course of treatment the total dose degradation of D{sub 99} was 2%-3%, with a standard deviation of <2%. Absolute differences between SFUD, intensity modulate proton therapy, and one-field-per-day SFUD plans were small. The intrafraction effect dominated over the residual interfraction effect for CTV coverage. Mean dose to the anterior rectal wall increased approximately 10% because of combined residual interfraction and intrafraction effects, the interfraction effect being dominant. Conclusions: Both intrafraction and residual interfraction prostate motion degrade CTV coverage within a clinically acceptable level. One-field-per-day SFUD delivered twice is as robust as the bilateral SFUD plan treated daily over the course of treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-265: Practical Issues and Solutions in Reconstructing and Using 4DCT for Radiotherapy Planning of Lung Cancer

Purpose: To report practical issues and solutions in reconstructing and using 4DCT to account for respiratory motion in radiotherapy planning. Methods: Quiet breathing 4DCT was used to account for respiratory motion for patients with lung or upper abdomen tumor. A planning CT and a 4DCT were acquired consecutively with a Philips Brilliance CT scanner and Varian RPM System. The projections were reconstructed into 10 phases. In Pinnacle RTP system, we contour a GTV in each phase and unite all 10 GTVs as ITV. The ITV is then mapped to the planning CT. We describe practical issues, their causes, our solutions and reasoning during this process. Results: In 6 months, 9 issues were reported for 8 patients with lung cancer. For two patients, part of the GTV (∼50% and 10%) in planning CT fell outside the ITV in 4DCT. There was a 7 mm variation in first patient back position because less restricted immobilization had to be used. The second discrepancy was due to moderate variation in breathing amplitude. We extended the ITV to include the GTV since both variations may likely happen during treatment. A LUL tumor showed no motion due to a 10-s long no-breathing period. An RLL tumor appeared double due to an abnormally deeper breath at the tumor region. We repeated 4DCT reiterating the importance of quiet, regular breathing. One patient breathed too light to generate RPM signal. Two issues (no motion in lung, incomplete images in 90% phase) were due to incorrect tag positions. Two unexplainable errors disappeared when repeating reconstruction. In summary, 5 issues were patient-related and 4 were technique issues. Conclusion: Improving breathing regularity avoided large artifacts in 4DCT. One needs to closely monitor patient breathing. For uncontrollable variations, larger PTVs are necessary which requires appropriate communication between physics and the treating physician.

60 APPLIED LIFE SCIENCES↗

A method of dose reconstruction for moving targets compatible with dynamic treatments

Purpose: To develop a method that allows a commercial treatment planning system (TPS) to perform accurate dose reconstruction for rigidly moving targets and to validate the method in phantom measurements for a range of treatments including intensity modulated radiation therapy (IMRT), volumetric arc therapy (VMAT), and dynamic multileaf collimator (DMLC) tracking. Methods: An in-house computer program was developed to manipulate Dicom treatment plans exported from a TPS (Eclipse, Varian Medical Systems) such that target motion during treatment delivery was incorporated into the plans. For each treatment, a motion including plan was generated by dividing the intratreatment target motion into 1 mm position bins and construct sub-beams that represented the parts of the treatment that were delivered, while the target was located within each position bin. For each sub-beam, the target shift was modeled by a corresponding isocenter shift. The motion incorporating Dicom plans were reimported into the TPS, where dose calculation resulted in motion including target dose distributions. For experimental validation of the dose reconstruction a thorax phantom with a moveable lung equivalent rod with a tumor insert of solid water was first CT scanned. The tumor insert was delineated as a gross tumor volume (GTV), and a planning target volume (PTV) was formed by adding margins. A conformal plan, two IMRT plans (step-and-shoot and sliding windows), and a VMAT plan were generated giving minimum target doses of 95% (GTV) and 67% (PTV) of the prescription dose (3 Gy). Two conformal fields with MLC leaves perpendicular and parallel to the tumor motion, respectively, were generated for DMLC tracking. All treatment plans were delivered to the thorax phantom without tumor motion and with a sinusoidal tumor motion. The two conformal fields were delivered with and without portal image guided DMLC tracking based on an embedded gold marker. The target dose distribution was measured with a radiochromic film in the moving rod and compared with the reconstructed doses using gamma tests. Results: Considerable interplay effects between machine motion and target motion were observed for the treatments without tracking. For nontracking experiments, the mean 2 mm/2% gamma pass rate over all investigated scenarios was 99.6% between calculated and measured doses. For tracking experiments, the mean gamma pass rate was 99.4%. Conclusions: A method for accurate dose reconstruction for moving targets with dynamic treatments was developed and experimentally validated in a variety of delivery scenarios. The method is suitable for integration into TPSs, e.g., for reconstruction of the dose delivered to moving tumors or calculation of target doses delivered with DMLC tracking.

60 APPLIED LIFE SCIENCES↗

Effects of residual target motion for image-tracked spine radiosurgery

A quality assurance method was developed to investigate the effects of residual target motion for hypofractionated spine radiosurgery. The residual target motion (target movement between successive image-guided corrections) was measured on-line via dual x-ray imagers for patients treated with CyberKnife (Accuray, Inc., Sunnyvale, CA), a robotic linear accelerator with intrafractional image-tracking capability. The six degree-of-freedom characteristics of the residual target motion were analyzed, the effects of such motion on patient treatment delivery were investigated by incorporating the probability distribution of the residual motion into the treatment planning dose calculations, and deviations of the doses from those originally planned were calculated. Measurements using a programmable motion phantom were also carried out and compared with the static treatment plan calculations. It was found that the residual target motions were patient specific and typically on the order of 2 mm. The measured dose distributions incorporating the residual target motion also exhibited 2.0 mm discrepancy at the prescription isodose level when compared with the static treatment plan calculations. For certain patients, residual errors introduced significant uncertainties ({approx}1 Gy) for the dose delivered to the spinal cord, especially at the high dose levels covering a small volume of the spinal cord (e.g., 0.1 cc). In such cases, stringent cord constraints and frequent monitoring of the target position should be implemented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Time-Adjusted Internal Target Volume: A Novel Approach Focusing on Heterogeneity of Tumor Motion Based on 4-Dimensional Computed Tomography Imaging for Radiation Therapy Planning of Lung Cancer

Purpose: To consider nonuniform tumor motion within the internal target volume (ITV) by defining time-adjusted ITV (TTV), a volume designed to include heterogeneity of tumor existence on the basis of 4-dimensional computed tomography (4D-CT). Methods and Materials: We evaluated 30 lung cancer patients. Breath-hold CT (BH-CT) and free-breathing 4D-CT scans were acquired for each patient. The tumors were manually delineated using a lung CT window setting (window, 1600 HU; level, −300 HU). Tumor in BH-CT images was defined as gross tumor volume (GTV), and the sum of tumors in 4D-CT images was defined as ITV-4D. The TTV images were generated from the 4D-CT datasets, and the tumor existence probability within ITV-4D was calculated. We calculated the TTV{sub 80} value, which is the percentage of the volume with a tumor existence probability that exceeded 80% on ITV-4D. Several factors that affected the TTV{sub 80} value, such as the ITV-4D/GTV ratio or tumor centroid deviation, were evaluated. Results: Time-adjusted ITV images were acquired for all patients, and tumor respiratory motion heterogeneity was visualized. The median (range) ITV-4D/GTV ratio and median tumor centroid deviation were 1.6 (1.0-4.1) and 6.3 mm (0.1-30.3 mm), respectively. The median TTV{sub 80} value was 43.3% (2.9-98.7%). Strong correlations were observed between the TTV{sub 80} value and the ITV-4D/GTV ratio (R=−0.71) and tumor centroid deviation (R=−0.72). The TTV images revealed the tumor motion pattern features within ITV. Conclusions: The TTV images reflected nonuniform tumor motion, and they revealed the tumor motion pattern features, suggesting that the TTV concept may facilitate various aspects of radiation therapy planning of lung cancer while incorporating respiratory motion in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-BRA-12: Development of An Intra-Fractional Motion Tracking and Dose Reconstruction System for Adaptive Stereotactic Body Radiation Therapy in High-Risk Prostate Cancer

Purpose: A clinical trial on stereotactic body radiation therapy (SBRT) for high-risk prostate cancer is undergoing at our institution. In addition to escalating dose to the prostate, we have increased dose to intra-prostatic lesions. Intra-fractional prostate motion deteriorates well planned radiation dose, especially for the small intra-prostatic lesions. To solve this problem, we have developed a motion tracking and 4D dose-reconstruction system to facilitate adaptive re-planning. Methods: Patients in the clinical trial were treated with VMAT using four arcs and 10 FFF beam. KV triggered x-ray projections were taken every 3 sec during delivery to acquire 2D projections of 3D anatomy at the direction orthogonal to the therapeutic beam. Each patient had three implanted prostate markers. Our developed system first determined 2D projection locations of these markers and then 3D prostate translation and rotation via 2D/3D registration of the markers. Using delivery log files, our GPU-based Monte Carlo tool (goMC) reconstructed dose corresponding to each triggered image. The calculated 4D dose distributions were further aggregated to yield the delivered dose. Results: We first tested each module in our system. MC dose engine were commissioned to our treatment planning system with dose difference of <0.5%. For motion tracking, 1789 kV projections from 7 patients were acquired. The 2D marker location error was <1 mm. For 3D motion tracking, root mean square (RMS) errors along LR, AP, and CC directions were 0.26mm, 0.36mm, and 0.01mm respectively in simulation studies and 1.99mm, 1.37mm, and 0.22mm in phantom studies. We also tested the entire system workflow. Our system was able to reconstruct delivered dose. Conclusion: We have developed a functional intra-fractional motion tracking and 4D dose re-construction system to support our clinical trial on adaptive high-risk prostate cancer SBRT. Comprehensive evaluations have shown the capability and accuracy of our system.

60 APPLIED LIFE SCIENCES↗

Markerless tracking of small lung tumors for stereotactic radiotherapy

Purpose: (1) To validate retrospective markerless tracking software for small lung tumors by comparing tracked motion in 4-dimensional planning computed tomography (4DCT) derived kV projection images and known tumor motion in the same 4DCT. (2) To evaluate variability of tumor motion using kV projection images from cone-beam computed tomography (CBCT) scans acquired on different days. Methods: Nonclinical tumor tracking software (TTS) used a normalized cross correlation algorithm to track the tumor on enhanced kV projection images (e.g., from a CBCT scan). The reference dataset consisted of digitally reconstructed radiographs (DRRs) from one phase of a planning 4DCT. TTS matches two in-plane coordinates and obtains the out-of-plane coordinate by triangulating with match results from other projections. (1) To validate TTS, tracking results were compared with known 4DCT tumor motion for two patients (A and B). Projection images (1 image/1°) were digitally reconstructed for each 4DCT phase. From these, kV projection series were composed simulating full breathing cycles every 20° of gantry rotation [breathing period = 20°/(6°/s) = 3.33 s]. Reference templates were 360 “tumor enhanced” DRRs from the 4DCT expiration phase. TTS-derived tumor motion was compared to known tumor motion on 4DCT. (2) For five patients, TTS-assessed motion during clinical CBCT acquisition was compared with motion on the planning 4DCT, and the motion component in the Y (cranio–caudal)-direction was compared with the motion of an external marker box (RPM, real-time position management). Results: (1) Validation results: TTS for case A (tumor 6.2 cm{sup 3}, 32 mm axial diameter) over 360° showed mean motion X (medial–lateral) = 3.4, Y = 11.5, and Z (ventral–dorsal) = 4.9 mm (1 SD < 1.0 mm). Corresponding 4DCT motion was X = 3.1, Y = 11.3, and Z = 5.1 mm. Correlation coefficients between TTS tumor motion and displacement of the tumor’s center of mass (CoM) on 4DCT were 0.64, 0.96, and 0.82 (X, Y, and Z, respectively). For case B (4.1 cm{sup 3}, 20 mm diameter), due to temporarily decreased tumor visibility preventing TTS from resolving the tumor, robust tracking data were only available between angles 300°–40° and 120°–220°. Mean motion according to TTS was X = 2.0, Y = 7.7, and Z = 8.2 mm (1 SD < 0.9 mm). Tumor motion on 4DCT was X = 1.8, Y = 7.6, and Z = 9.5 mm and correlation coefficients between TTS motion and CoM displacement were 0.59, 0.95, and 0.93 (X, Y, and Z, respectively). (2) Clinical results: TTS revealed a mean intrafraction variation in tumor motion in Y-direction of >2.0 mm (1 SD) in four of five patients. In addition, clinical tumor motion amplitude differed from that seen on planning 4DCT. Internal and external structures that create abrupt density change (e.g., table-top edge, interface between lung/mediastinum and lung/heart) were observed to prevent 360° tracking of the tumor. Correlation coefficients between TTS motion in the Y-direction and the RPM signal (22 observations) ranged from 0.78 to 0.96. In 2D, 241 TTS matches at end-inspiration and end-expiration were visually validated: mean difference was 0.8 mm (SD = 0.7) for both. Conclusions: TTS can track small lung tumors if these are visible in kV projections. A 4DCT dataset can be used to validate kV tracking of moving targets. TTS and 4DCT displacement agreed to within 2 mm. TTS and RPM motion were closely associated but tumor motion during CBCT can vary from the planning 4DCT.

60 APPLIED LIFE SCIENCES↗

SU-E-T-428: Feasibility Study of 4D Image Reconstruction by Organ Motion Vector Extension Based On Portal Images

Purpose: To develop and to test a method to generate a new 4D CT images of the treatment day from the old 4D CT and the portal images of the day when the motion extent exceeded from that represented by plan CTs. Methods: A motion vector of a moving tumor in a patient may be extended to reconstruct the tumor position when the motion extent exceeded from that represented by plan CTs. To test this, 1. a phantom that consists of a polystyrene cylinder (tumor) embedded in cork (lung) was placed on a moving platform with 4 sec/cycle and amplitudes of 1 cm and 2 cm, and was 4D-scanned. 2. A 6MV photon beam was irradiated on the moving phantoms and cineEPID images were obtained. 3. A motion vector of the tumor was acquired from 4D CT images of the phantom with 1 cm amplitude. 4. From cine EPID images of the phantom with the 2 cm amplitude, various motion extents (0.3 cm, 0.5 cm, etc) were acquired and programmed into the motion vector, producing CT images at each position. 5. The reconstructed CT images were then compared with pre-acquired “reference” 4D CT images at each position (i.e. phase). Results: The CT image was reconstructed and compared with the reference image, showing a slight mismatch in the transition direction limited by voxel size (slice thickness) in CT image. Due to the rigid nature of the phantom studied, the modeling the displacement of the center of object was sufficient. When deformable tumors are to be modeled, more complex scheme is necessary, which utilize cine EPID and 4D CT images. Conclusion: The new idea of CT image reconstruction was demonstrated. Deformable tumor movements need to be considered in the future.

60 APPLIED LIFE SCIENCES↗

Quantification of Motion of Different Thoracic Locations Using Four-Dimensional Computed Tomography: Implications for Radiotherapy Planning

Purpose: To assess the respiratory motion of different thoracic nodal locations and its dependence on the presence of enlarged nodes; to assess the respiratory motion of different parenchymal tumor locations; and to determine the appropriate margins to cover the respiratory motion of targets at these locations. Methods and Materials: We reviewed the four-dimensional computed tomography scans of 20 patients with thoracic tumors treated at our institution. The motion of four central thoracic locations (aortic arch, carina, and bilateral hila), parenchymal tumor locations (upper vs. lower, and anterior vs. middle vs. posterior thorax), and bilateral diaphragmatic domes was measured. Results: For the central thoracic locations, the largest motion was in the superoinferior (SI) dimension (>5 mm for bilateral hila and carina, but <4 mm for aortic arch). No significant difference was found in the motion of these locations in the absence or presence of enlarged nodes. For parenchymal tumors, upper tumors exhibited smaller SI motion than did lower tumors (3.7 vs. 10.4 mm, p = 0.029). Similarly, anterior tumors exhibited smaller motion than did posterior tumors in both the SI (4.0 vs. 8.0 mm, p = 0.013) and lateral (2.8 vs. 4.6 mm, p = 0.045) directions. The margins that would be needed to encompass the respiratory motion of each of the evaluated locations in 95% of patients were tabulated and range from 3.4 to 37.2 mm, depending on the location and direction. Conclusions: The results of our study have provided data for appropriate site-specific internal target volume expansion that could be useful in the absence of four-dimensional computed tomography-based treatment planning. However, generalizing the results from a small patient population requires discretion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Planning time-optimal robotic manipulator motions and work places for point-to-point tasks

A method is presented which combines simple time-optimal motions in an optimal manner to yield the minimum-time motions for an important class of complex manipulator tasks composed of point-to-point moves such as assembly, electronic component insertion, and spot welding. This method can also be used to design manipulator actions and work places so that tasks can be completed in minimum time. The method has been implemented in a computer-aided design software system. Several examples are presented. Experimental results show the method's validity and utility.

Dubowsky, S.↗

SU-E-T-442: Geometric Calibration and Verification of a GammaPod Breast SBRT System

Purpose: The first GammaPod™ unit for prone stereotactic treatment of early stage breast cancer has recently been installed and calibrated. Thirty-six rotating circular Co-60 beams focus dose at an isocenter that traverses throughout a breast target via continuous motion of the treatment table. The breast is immobilized and localized using a vacuum-assisted stereotactic cup system that is fixed to the table during treatment. Here we report on system calibration and on verification of geometric and dosimetric accuracy. Methods: Spatial calibration involves setting the origin of each table translational axis within the treatment control system such that the relationship between beam isocenter and table geometry is consistent with that assumed by the treatment planning system. A polyethylene QA breast phantom inserted into an aperture in the patient couch is used for calibration and verification. The comparison is performed via fiducial-based registration of measured single-isocenter dose profiles (radiochromic film) with kernel dose profiles. With the table calibrations applied, measured relative dose distributions were compared with TPS calculations for single-isocenter and dynamic (many-isocenter) treatment plans. Further, table motion accuracy and linearity was tested via comparison of planned control points with independent encoder readouts. Results: After table calibration, comparison of measured and calculated single-isocenter dose profiles show agreement to within 0.5 mm for each axis. Gamma analysis of measured vs calculated profiles with 3%/2mm criteria yields a passing rate of >99% and >98% for single-isocenter and dynamic plans respectively. This also validates the relative dose distributions produced by the TPS. Measured table motion accuracy was within 0.05 mm for all translational axes. Conclusion: GammaPod table coordinate calibration is a straightforward process that yields very good agreement between planned and measured relative dose distributions. The dynamic table motions used for dose painting are consistent with planned control points. CY, YN, PM, PH are employees of Xcision Medical Systems.

60 APPLIED LIFE SCIENCES↗