Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “modulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Study for reducing lung dose of upper thoracic esophageal cancer radiotherapy by auto-planning: volumetric-modulated arc therapy vs intensity-modulated radiation therapy

This study aimed to investigate the dosimetric differences and lung sparing between volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) in the treatment of upper thoracic esophageal cancer with T3N0M0 for preoperative radiotherapy by auto-planning (AP). Sixteen patient cases diagnosed with upper thoracic esophageal cancer T3N0M0 for preoperative radiotherapy were retrospectively studied, and 3 plans were generated for each patient: full arc VMAT AP plan with double arcs, partial arc VMAT AP plan with 6 partial arcs, and conventional IMRT AP plan. A simultaneous integrated boost with 2 levels was planned in all patients. Target coverage, organ at risk sparing, treatment parameters including monitor units and treatment time (TT) were evaluated. Wilcoxon signed-rank test was used to check for significant differences (p 20 ), 25 Gy (V{sub 25}), 30 Gy (V{sub 30}), 35 Gy (V{sub 35}), 40 Gy (V{sub 40}), and without increasing the value of V{sub 10}, V{sub 13}, and V{sub 15}. For V{sub 5} of total lung value, pVMAT was similar to aIMRT, and it was better than fVMAT. Both pVMAT and fVMAT improved the target dose coverage and significantly decreased maximum dose for the spinal cord, monitor unit, and TT. No significant difference was observed with respect to V{sub 10} and V{sub 15} of body. VMAT AP plan was a good option for treating upper thoracic esophageal cancer with T3N0M0, especially partial arc VMAT AP plan. It had the potential to effectively reduce lung dose in a shorter TT and with superior target coverage and dose homogeneity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct Observation of Modulated Radical Spin States in Metal–Organic Frameworks by Controlled Flexibility

Owing to their switchable spin states and dynamic electronic character, organic-based radical species have been invoked in phenomena unique to a variety of fields. When incorporated in solid state materials, generation of organic radicals proves challenging due to aggregation. Metal–organic frameworks (MOFs) are promising candidates for immobilization and stabilization of organic radicals because of the tunable spatial arrangement of organic linkers and metal nodes, which sequesters the reactive species. Herein, a flexible, redox-active tetracarboxylic acid linker bearing two imidazole units was chosen to construct a new Zr 6 -MOF, NU-910, with scu topology. By exploiting the structural flexibility of NU-910, we successfully modulate the dynamics between an isolated organic radical species and an organic radical π-dimer species in the MOF system. Single-crystal X-ray diffraction analysis reveals that through solvent exchange from N,N-diethylformamide to acetone, NU-910 undergoes a structural contraction with interlinker distances decreasing from 8.32 Å to 3.20 Å at 100 K. Organic radical species on the bridging linkers are generated via UV light irradiation. Direct observation of temperature-induced spin switches from an isolated radical species to a magnetically silent radical π-dimer in NU-910 after irradiation in the solid state was achieved via variable-temperature single-crystal X-ray diffraction and variable-temperature electron paramagnetic resonance spectroscopy. Ultraviolet–visible–near infrared spectroscopy and density functional theory calculations further substantiated the formation of a radical cation π-dimer upon irradiation. As a result, this work demonstrates the potential of using flexible MOFs as a platform to modulate radical spin states in the solid phase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modulating Chemical Environments of Metal–Organic Framework-Supported Molybdenum(VI) Catalysts for Insights into the Structure–Activity Relationship in Cyclohexene Epoxidation

Solid supports are crucial in heterogeneous catalysis due to their profound effects on catalytic activity and selectivity. However, elucidating the specific effects arising from such supports remains challenging. We selected a series of metal–organic frameworks (MOFs) with 8-connected Zr 6 nodes as supports to deposit molybdenum(VI) onto to study the effects of pore environment and topology on the resulting Mo-supported catalysts. As characterized by X-ray absorption spectroscopy (XAS) and single-crystal X-ray diffraction (SCXRD), we modulated the chemical environments of the deposited Mo species. For Mo-NU-1000, the Mo species monodentately bound to the Zr 6 nodes were anchored in the microporous c-pore, but for Mo-NU-1008 they were bound in the mesopore of Mo-NU-1008. Both monodentate and bidentate modes were found in the mesopore of Mo-NU-1200. Cyclohexene epoxidation with H 2 O 2 was probed to evaluate the support effect on catalytic activity and to unveil the resulting structure–activity relationships. SCXRD and XAS studies demonstrated the atomically precise structural differences of the Mo binding motifs over the course of cyclohexene epoxidation. No apparent structural change was observed for Mo-NU-1000, whereas the monodentate mode of Mo species in Mo-NU-1008 and the monodentate and bidentate Mo species in Mo-NU-1200 evolved to a new bidentate mode bound between two adjacent oxygen atoms from the Zr 6 node. This work demonstrates the great advantage of using MOF supports for constructing heterogeneous catalysts with modulated chemical environments of an active species and elucidating structure–activity relationships in the resulting reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spatial Control Of Functional Properties Via Octahedral Modulations In Complex Oxide Superlattices

The design of distortions and rotations of the corner-connected BO6 octahedra across interfaces has emerged as an exciting platform to control electronic or ferroic behavior in ABO3 perovskite heterostructures. Here, we investigate isovalent manganite superlattices, [(La0.7Sr0.3MnO3)n/(Eu0.7Sr0.3MnO3)n]×m, as a route to spatial control over electronic bandwidth and ferromagnetism through the creation of octahedral superstructures. Electron energy loss spectroscopy confirms a uniform Mn valence state throughout the superlattices. In contrast, the presence of modulations of the MnO6 octahedral rotations along the growth direction commensurate with the superlattice period is revealed by scanning transmission electron microscopy and x-ray diffraction. We show that the Curie temperatures of the constituent materials can be systematically engineered via the octahedral superstructures leading to a modulated magnetization in samples where the superlattice period is larger than the interfacial octahedral coupling length scale, while a single magnetic transition is observed in the short period superlattices.

Environmental Molecular Sciences Laboratory↗

Building in vitro transcriptional regulatory networks by successively integrating multiple functional circuit modules

The regulation of cellular dynamics and responses to stimuli by genetic regulatory networks suggests how in vitro chemical reaction networks might analogously direct the dynamics of synthetic materials or chemistries. A key step in developing genetic regulatory network analogues capable of this type of sophisticated regulation is the integration of multiple coordinated functions within a single network. In this study, we demonstrate how such functional integration can be achieved using in vitro transcriptional genelet circuits that emulate essential features of cellular genetic regulatory networks. By successively incorporating functional genelet modules into a bistable circuit, we construct an integrated regulatory network that dynamically changes its state in response to upstream stimuli and coordinates the timing of downstream signal expression. We use quantitative models to guide module integration and develop strategies to mitigate undesired interactions between network components that arise as the size of the network increases. This approach could enable the construction of in vitro networks capable of multifaceted chemical and material regulation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultraviolet Fluorescence Imaging for Photovoltaic Module Metrology: Best Practices and Survey of Features Observed in Fielded Modules

As the photovoltaics (PV) industry grows in sophistication, so must the extent to which systems are characterized. UV Fluorescence (UVF) imaging is a valuable, easy-to-perform, high-throughput, nonintrusive technique for characterizing modules in the field and in the lab. However, UVF is still a relatively new technique, and many in the PV industry are still unaware of its potential. We provide a guideline for obtaining, processing, and interpreting UVF images. We have provided a list of considerations for imaging hardware and settings, a suggested pipeline for image processing, and details on a survey of features shown in UVF images. As a result, a new database with UVF images of 7190 modules and another database curated by BrightSpot Automation are publicly available.

14 SOLAR ENERGY↗

Analysis and Optimization of a Multi-Layer Integrated Organic Substrate for High Current GaN HEMT-Based Power Module

In this paper, analysis and optimization of a multi-layer organic substrate for high current GaN HEMT based power module are discussed. The organic multi-layer substrates can provide high electrical performance in terms of low parasitic inductance in the power loop by providing vertical layout, and shielding for reduction of common-mode noise, a common problem in fast switching power converters. Furthermore, high performance cooling solutions, such as micro-channel heat sinks, can be directly bonded to the substrate for optimum thermal management. The structure of the proposed architecture, thermal analysis and optimization of layer thickness, thermo-mechanical stress analysis of the GaN HEMT and development of a high-performance heat sink are discussed.

47 OTHER INSTRUMENTATION↗

Tonoplast Sucrose Transporter SUT4-Dependent Sugar Partitioning Modulates Phenological Transitions and Reproductive Success in Poplar

Climate uncertainty is intensifying the need for greater plasticity in carbohydrate reserve utilization to support winter survival and spring growth in woody perennials. In poplar, the single-copy SUT4, which encodes a tonoplast-localized sucrose transporter, and the SUT5/SUT6 genome duplicates, which encode plasma membrane-localized transporters, are expressed year-round, with SUT4 showing the highest expression during cool seasons. Given its role in vacuolar sucrose efflux and winter-predominant expression, SUT4 may play a key role in modulating seasonal carbohydrate dynamics. While SUT4-knockdown and knockout effects have been studied under greenhouse conditions, their impact under field conditions remains unexplored. Here, we report a field-based study comparing CRISPR knockout mutants of winter-expressed SUT4 and SUT5/SUT6 in Populus tremula x alba. We show that sut4, but not sut5/6, mutants exhibited earlier autumn leaf senescence, delayed spring bud flush, reduced stem growth, and altered sugar partitioning in winter xylem and bark relative to controls. After 2 years in the field, all genotypes flowered before leaf flush in early spring; however, sut4 mutants produced sterile ovules despite developing normal-looking catkins. Metabolic profiling revealed disrupted sucrose and raffinose dynamics in elongating sut4 catkins. This was accompanied by transcriptomic signatures of elevated stress and downregulation of proanthocyanidin biosynthesis and circadian clock genes. These findings highlight the critical role of SUT4 in coordinating sugar allocation, stress responses, and seasonal development in poplar.

09 BIOMASS FUELS↗

Electric and Hydraulic Propel Torque Modulation for a Compact Track Loader With the Hybrid Hydraulic Electric Architecture (HHEA)

Abstract The Hybrid Hydraulic Electric Architecture (HHEA) has previously been proposed for off-highway vehicles to reap the efficiency and controllability benefits of electrification without needing very large electric motors. This is achieved with the use of a set of selectable common pressure rails to transmit the majority of power and small electric motors to modulate that power. Previous work has shown significant energy savings for the work circuits of a variety of machines. In this paper, the energy saving potential of HHEA for the propel circuit of a compact track loader is studied. The ports of the track hydraulic motors are selectably connected to the common pressure rails, and instead of using the electric assist motors to buck/boost pressure, as in HHEA for linear actuators, small electric assist motors are used to add/subtract torque directly. The interplay between the torque limits of the electric motors and the ability of the hydraulic motor to vary displacements is studied, along with the effect these factors have on energy saving potential. It is found that the ability to vary the displacement of the hydraulic motor allows for: more efficient electric motor operating conditions, reduced electric torque requirement, and reduced pressure rail switching events. All three of these advantages can be achieved at once using variable displacements; but trade-offs exist between these advantages (i.e. improved efficiency can be achieved at the expense of a larger electric torque requirement). Overall, the HHEA can reduce energy consumption by ∼ 36% compared to the stock machine, depending on the hydraulic motor’s ability to vary displacements, and assuming the electric motor torque is limited to 20% of that required in a direct electrification scheme.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Monte Carlo based beam model using a photon MLC for modulated electron radiotherapy

Purpose: Modulated electron radiotherapy (MERT) promises sparing of organs at risk for certain tumor sites. Any implementation of MERT treatment planning requires an accurate beam model. The aim of this work is the development of a beam model which reconstructs electron fields shaped using the Millennium photon multileaf collimator (MLC) (Varian Medical Systems, Inc., Palo Alto, CA) for a Varian linear accelerator (linac). Methods: This beam model is divided into an analytical part (two photon and two electron sources) and a Monte Carlo (MC) transport through the MLC. For dose calculation purposes the beam model has been coupled with a macro MC dose calculation algorithm. The commissioning process requires a set of measurements and precalculated MC input. The beam model has been commissioned at a source to surface distance of 70 cm for a Clinac 23EX (Varian Medical Systems, Inc., Palo Alto, CA) and a TrueBeam linac (Varian Medical Systems, Inc., Palo Alto, CA). For validation purposes, measured and calculated depth dose curves and dose profiles are compared for four different MLC shaped electron fields and all available energies. Furthermore, a measured two-dimensional dose distribution for patched segments consisting of three 18 MeV segments, three 12 MeV segments, and a 9 MeV segment is compared with corresponding dose calculations. Finally, measured and calculated two-dimensional dose distributions are compared for a circular segment encompassed with a C-shaped segment. Results: For 15 × 34, 5 × 5, and 2 × 2 cm{sup 2} fields differences between water phantom measurements and calculations using the beam model coupled with the macro MC dose calculation algorithm are generally within 2% of the maximal dose value or 2 mm distance to agreement (DTA) for all electron beam energies. For a more complex MLC pattern, differences between measurements and calculations are generally within 3% of the maximal dose value or 3 mm DTA for all electron beam energies. For the two-dimensional dose comparisons, the differences between calculations and measurements are generally within 2% of the maximal dose value or 2 mm DTA. Conclusions : The results of the dose comparisons suggest that the developed beam model is suitable to accurately reconstruct photon MLC shaped electron beams for a Clinac 23EX and a TrueBeam linac. Hence, in future work the beam model will be utilized to investigate the possibilities of MERT using the photon MLC to shape electron beams.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toward optimal organ at risk sparing in complex volumetric modulated arc therapy: An exponential trade-off with target volume dose homogeneity

Purpose: Conventional radiotherapy typically aims for homogenous dose in the planning target volume (PTV) while sparing organs at risk (OAR). The authors quantified and characterized the trade-off between PTV dose inhomogeneity (IH) and OAR sparing in complex head and neck volumetric modulated arc therapy plans. Methods: Thirteen simultaneous integrated boost plans were created per patient, for ten patients. PTV boost{sub (B)}/elective{sub (E)} optimization priorities were systematically increased. IH{sub B} and IH{sub E}, defined as (100% − V95%) + V107%, were evaluated against the average of the mean dose to the combined composite swallowing and combined salivary organs (D-OAR{sub comp}). To investigate the influence of OAR size and position with respect to PTV{sub B/E}, OAR dose was evaluated against a modified Euclidean distance (DM{sub B}/DM{sub E}) between OAR and PTV. Results: Although the achievable D-OAR{sub comp} for a given level of PTV IH differed between patients, excellent logarithmic fits described the D-OAR{sub comp}/IH{sub B} and IH{sub E} relationship in all patients (mean R{sup 2} of 0.98 and 0.97, respectively). Allowing an increase in average IH{sub B} and IH{sub E} over a clinically acceptable range, e.g., from 0.4% ± 0.5% to 2.0% ± 2.0% and 6.9% ± 2.8% to 14.8% ± 2.7%, respectively, corresponded to a decrease in average dose to the composite salivary and swallowing structures from 30.3 ± 6.5 to 23.6 ± 4.7 Gy and 32.5 ± 8.3 to 26.8 ± 9.3 Gy. The increase in PTV{sub E} IH was mainly accounted for by an increase in V107, by on average 5.9%, rather than a reduction in V95, which was on average only 2%. A linear correlation was found between the OAR dose to composite swallowing structures and contralateral parotid and submandibular gland, with DM{sub E} (R{sup 2} = 0.83, 0.88, 0.95). Only mean ipsilateral parotid dose correlated with DM{sub B} (R{sup 2} = 0.87). Conclusions: OAR sparing is highly dependent on the permitted PTV{sub B/E} IH. PTV{sub E} IH substantially influences OAR doses. These results are relevant for clinical practice and for future automated treatment-planning strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-62: Cardiac Toxicity in Dynamic Conformal Arc Therapy, Intensity-Modulated Radiation Therapy and Volumetric Modulated Arc Therapy of Lung Cancers

Purpose: The cardiac toxicity for lung cancer patients, each treated with dynamic conformal arc therapy (DAT), intensity-modulated radiation therapy (IMRT), or volumetric modulated arc therapy (VMAT) is investigated. Methods: 120 lung patients were selected for this study: 25 treated with DAT, 50 with IMRT and 45 with VMAT. For comparison, all plans were generated in the same treatment planning system, normalized such that the 100% isodose lines encompassed 95% of planning target volume. The plan quality was evaluated in terms of homogeneity index (HI) and 95% conformity index (%95 CI) for target dose coverage and mean dose, maximum dose, V{sub 30} Gy as well as V{sub 5} Gy for cardiac toxicity analysis. Results: When all the plans were analyzed, the VMAT plans offered the best target coverage with 95% CI = 0.992 and HI = 1.23. The DAT plans provided the best heart sparing with mean heart dose = 2.3Gy and maximum dose = 11.6Gy, as compared to 5.7 Gy and 31.1 Gy by IMRT as well as 4.6 Gy and 30.9 Gy by VMAT. The mean V30Gy and V5Gy of the heart in the DAT plans were up to 11.7% lower in comparison to the IMRT and VMAT plans. When the tumor volume was considered, the VMAT plans spared up to 70.9% more doses to the heart when the equivalent diameter of the tumor was larger than 4cm. Yet the maximum dose to the heart was reduced the most in the DAT plans with up to 139.8% less than that of the other two plans. Conclusion: Overall, the VMAT plans achieved the best target coverage among the three treatment modalities, and would spare the heart the most for the larger tumors. The DAT plans appeared advantageous in delivering the least maximum dose to the heart as compared to the IMRT and VMAT plans.

60 APPLIED LIFE SCIENCES↗