Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “minimum loss”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

TESTING MASS LOSS IN LARGE MAGELLANIC CLOUD CEPHEIDS USING INFRARED AND OPTICAL OBSERVATIONS. II. PREDICTIONS AND TESTS OF THE OGLE-III FUNDAMENTAL-MODE CEPHEIDS

In this paper, we test the hypothesis that Cepheids have infrared excesses due to mass loss. We fit a model using the mass-loss rate and the stellar radius as free parameters to optical observations from the OGLE-III survey and infrared observations from the Two Micron All Sky Survey and SAGE data sets. The sample of Cepheids has predicted minimum mass-loss rates ranging from 0 to 10{sup -8} M{sub sun} yr{sup -1}, where the rates depend on the chosen dust properties. We use the predicted radii to compute the period-radius relation for LMC Cepheids and to estimate the uncertainty caused by the presence of infrared excess for determining angular diameters with the infrared surface brightness technique. Finally, we calculate the linear and nonlinear period-luminosity (P-L) relations for the LMC Cepheids at VIJHK + IRAC wavelengths and find that the P-L relations are consistent with being nonlinear at infrared wavelengths contrary to previous results.

79 ASTRONOMY AND ASTROPHYSICS↗

Ka-band Ga-As FET noise receiver/device development

The development of technology for a 30 GHz low noise receiver utilizing GaAs FET devices exclusively is discussed. This program required single and dual-gate FET devices, low noise FET amplifiers, dual-gate FET mixers, and FET oscillators operating at Ka-band frequencies. A 0.25 micrometer gate FET device, developed with a minimum noise figure of 3.3 dB at 29 GHz and an associated gain of 7.4 dB, was used to fabricate a 3-stage amplifier with a minimum noise figure and associated gain of 4.4 dB and 17 dB, respectively. The 1-dB gain bandwidth of this amplifier extended from below 26.5 GHz to 30.5 GHz. A dual-gate mixer with a 2 dB conversion loss and a minimum noise figure of 10 dB at 29 GHz as well as a dielectric resonator stabilized FET oscillator at 25 GHz for the receiver L0. From these components, a hybrid microwave integrated circuit receiver was constructed which demonstrates a minimum single-side band noise figure of 4.6 dB at 29 GHz with a conversion gain of 17 dB. The output power at the 1-dB gain compression point was -5 dBm.

Schellenberg, J. M.↗

DC-9/JT8D refan, Phase 1

Analyses and design studies were conducted on the technical and economic feasibility of installing the JT8D-109 refan engine on the DC-9 aircraft. Design criteria included minimum change to the airframe to achieve desired acoustic levels. Several acoustic configurations were studied with two selected for detailed investigations. The minimum selected acoustic treatment configuration results in an estimated aircraft weight increase of 608 kg (1,342 lb) and the maximum selected acoustic treatment configuration results in an estimated aircraft weight increase of 809 kg (1,784 lb). The range loss for the minimum and maximum selected acoustic treatment configurations based on long range cruise at 10 668 m (35,000 ft) altitude with a typical payload of 6 804 kg (15,000 lb) amounts to 54 km (86 n. mi.) respectively. Estimated reduction in EPNL's for minimum selected treatment show 8 EPNdB at approach, 12 EPNdB for takeoff with power cutback, 15 EPNdB for takeoff without power cutback and 12 EPNdB for sideline using FAR Part 36. Little difference was estimated in EPNL between minimum and maximum treatments due to reduced performance of maximum treatment. No major technical problems were encountered in the study. The refan concept for the DC-9 appears technically feasible and economically viable at approximately $1,000,000 per airplane. An additional study of the installation of JT3D-9 refan engine on the DC-8-50/61 and DC-8-62/63 aircraft is included. Three levels of acoustic treatment were suggested for DC-8-50/61 and two levels for DC-8-62/63. Results indicate the DC-8 technically can be retrofitted with refan engines for approximately $2,500,000 per airplane.

Source record↗

Experimental Investigation of Shrouding on Meshed Spur Gear Windage Power Loss

Windage power loss in high-speed gearboxes result in efficiency losses and increased heating due to drag on the gear teeth. Meshed spur gear windage power loss test results are presented at ambient oil inlet temperatures both with and without shrouding. The rate of windage power loss is observed to increase above 10,000 ft.min., gear surface speed, similar to results presented in the literature. Shrouding is observed to become more effective above 15,000 ft.min., decreasing power loss by 10 at 25,000 ft.min. The need for gearbox oil drain slots limits the effectiveness of shrouding on reducing windage power loss. Also, windage power loss is observed to decrease with increasing gearbox temperatures and to increase with oil flow. Windage power losses for the unshrouded meshed spur gears are 7x more than losses determined from unshrouded single spur gear tests. A 6x to 12x increase in windage power is observed comparing shrouded single spur gear data with shrouded meshed spur gear data. Based on this preliminary study additional research is suggested to determine the effect of oil drain slot configurations, axial and radial shroud clearances, and higher gear surface speeds on windage power loss. Additional work is also suggested to determine the sensitivity of windage power loss to oil temperature and oil flow. Windage power loss of meshed spur gears tested in both the shrouded and unshrouded configurations is shown to be more than double versus the same spur gears run individually in the same shroud configurations. Further study of the physical processes behind these results is needed for optimizing gearbox shrouds for minimum windage power loss.

gear↗

Miniaturized Multi-Band Antenna via Element Collocation

The resonant frequency of a microstrip patch antenna may be reduced through the addition of slots in the radiating element. Expanding upon this concept in favor of a significant reduction in the tuned width of the radiator, nearly 60% of the antenna metallization is removed, as seen in the top view of the antenna’s radiating element (shown in red, below, left). To facilitate an increase in the gain of the antenna, the radiator is suspended over the ground plane (green) by an air substrate at a height of 0.250" while being mechanically supported by 0.030" thick Rogers RO4003 laminate in the same profile as the element. Although the entire surface of the antenna (red) provides 2.45 GHz operation with insignificant negative effects on performance after material removal, the smaller square microstrip in the middle must be isolated from the additional aperture in order to afford higher frequency operation. A low insertion loss path centered at 2.45 GHz may simultaneously provide considerable attenuation at additional frequencies through the implementation of a series-parallel, resonant reactive path. However, an inductive reactance alone will not permit lower frequency energy to propagate across the intended discontinuity. To mitigate this, a capacitance is introduced in series with the inductor, generating a resonance at 2.45 GHz with minimum forward transmission loss. Four of these reactive pairs are placed between the coplanar elements as shown. Therefore, the aperture of the lower-frequency outer segment includes the smaller radiator while the higher frequency section is isolated from the additional material. In order to avoid cross-polarization losses due to the orientation of a transmitter or receiver in reference to the antenna, circular polarization is realized by a quadrature coupler for each collocated antenna as seen in the bottom view of the antenna (right). To generate electromagnetic radiation concentrically rotating about the direction of propagation, ideally one-half of the power must be delivered to the output of each branch with a phase shift of 90 degrees and identical amplitude. Due to this, each arm of the coupler is spaced λ/4 wavelength apart.

42 ENGINEERING↗

First elevated-temperature performance testing of coated particle fuel compacts from the AGR-1 irradiation experiment

In the AGR-1 irradiation experiment, 72 coated-particle fuel compacts were taken to a peak burnup of 19.5% fissions per initial metal atom with no in-pile failures. This paper discusses the first post-irradiation test of these mixed uranium oxide/uranium carbide fuel compacts at elevated temperature to examine the fuel performance under a simulated depressurized conduction cooldown event. A compact was heated for 400 h at 1600 degrees C. Release of 85Kr was monitored throughout the furnace test as an indicator of coating failure, while other fission product releases from the compact were periodically measured by capturing them on exchangeable, water-cooled deposition cups. No coating failure was detected during the furnace test, and this result was verified by subsequent electrolytic deconsolidation and acid leaching of the compact, which showed that all SiC layers were still intact. However, the deposition cups recovered significant quantities of silver, europium, and strontium. Based on comparison of calculated compact inventories at the end of irradiation versus analysis of these fission products released to the deposition cups and furnace internals, the minimum estimated fractional losses from the compact during the furnace test were 1.9 x 10-2 for silver, 1.4 x 10-3 for europium, and 1.1 x 10-5 for strontium. Other post-irradiation examination of AGR-1 compacts indicates that similar fractions of europium and silver may have already been released by the intact coated particles during irradiation, and it is therefore likely that the detected fission products released from the compact in this 1600 degrees C furnace test were from residual fission products in the matrix. Gamma analysis of coated particles deconsolidated from the compact after the heating test revealed that silver content within each particle varied considerably; a result that is probably not related to the furnace test, because it has also been observed in other as-irradiated AGR-1 compacts. X-ray imaging of selected particles was performed to examine the internal microstructure. This examination revealed variable irradiation performance of the coating layers, but sufficient statistical sampling is not yet available to identify any possible correlation to variation in individual particle fission product retention.

99 GENERAL AND MISCELLANEOUS↗

THE VARIABILITY OF SAGITTARIUS A* AT 3 MILLIMETER

We have performed monitoring observations of the 3 mm flux density toward the Galactic center compact radio source Sagittarius A* (Sgr A*) with the Australia Telescope Compact Array since 2005 October. Careful calibrations of both elevation-dependent and time-dependent gains have enabled us to establish the variability behavior of Sgr A*. Sgr A* appeared to undergo a high and stable state in the 2006 June session, and a low and variable state in the 2006 August session. We report the results, with emphasis on two detected intraday variation events during its low states. One is on 2006 August 12 when Sgr A* exhibited a 33% fractional variation in about 2.5 hr. The other is on 2006 August 13 when two peaks separated by about 4 hr, with a maximum variation of 21% within 2 hr, were seen. The observed short timescale variations are discussed in light of two possible scenarios, i.e., the expanding plasmon model and the sub-Keplerian orbiting hot spot model. The fitting results indicate that for the adiabatically expanding plasmon model, the synchrotron cooling cannot be ignored, and a minimum mass-loss rate of 9.7 x 10{sup -10} M{sub sun} yr{sup -1} is obtained based on parameters derived for this modified expanding plasmon model. Simultaneous multiwavelength observation is crucial to our understanding of the physical origin of rapid radio variability in Sgr A*.

99 GENERAL AND MISCELLANEOUS↗

Optimizers for stabilizing likelihood-free inference

A growing number of applications in particle physics and beyond use neural networks as unbinned likelihood ratio estimators applied to real or simulated data. Precision requirements on the inference tasks demand a high-level of stability from these networks, which are affected by the stochastic nature of training. We show how physics concepts can be used to stabilize network training through a physics-inspired optimizer. In particular, the energy conserving descent (ECD) optimization framework uses classical Hamiltonian dynamics on the space of network parameters to reduce the dependence on the initial conditions while also stabilizing the result near the minimum of the loss function. We develop a version of this optimizer known as , which has few free hyperparameters with limited ranges guided by physical reasoning. We apply to representative likelihood-ratio estimation tasks in particle physics and find on average that it out-performs the widely used Adam optimizer. We expect that ECD will be a useful tool for wide array of data-limited problems, where it is computationally expensive to exhaustively optimize hyperparameters and mitigate fluctuations with ensembling.

Monte Carlo methods↗

The Extended Q-Range Small Angle Neutron Scattering Diffractometer at the SNS

The Extended Q-Range Small Angle Neutron Scattering Diffractometer (EQ-SANS) at the Spallation Neutron Source is designed to have wide neutron momentum transfer (Q) coverage, high neutron beam intensity, and good wavelength resolution. In addition, the design and construction of the instrument aim at achieving maximum signal to noise ratio by minimizing the background. The instrument is located on the 60Hz SNS target. It has a primary flight path of 14m. Its secondary flight path varies from ~1m to 10m. One of the key components in the primary flight path is the neutron optics, consisting of a true-curved multi channel beam bender and sections of neutron guides. The optics is optimized to reduce the neutron transport loss to a minimum, thereby maximizing the available flux on sample. It also enables the avoidance of the direct line of sight of the neutron moderator at downstream locations. The instrument has three bandwidth-limiting choppers. These choppers effectively eliminate higher frame neutrons up to ~38 from the beam. A frame overlap mirror further cleans up the beam by reflecting out neutrons whose wavelengths are longer than ~33 . The bandwidth choppers also allow a frame-skipping mode of operation, which enables the EQ-SANS diffractometer to achieve a dynamic Q-range equivalent to that of a similar machine on a 20Hz source. The two-dimensional low-angle detector, based on 3He tube technologies, offers very high counting rates and counting efficiency. Initial operations have shown that the instrument has achieved its best-in-class design requirement.

EQ-SANS↗

Resonant Extraction for Mu2e

Charged Lepton Flavor Violations (CLFVs) are probed in an attempt to search Beyond Standard Model (BSM) Physics. The sensitive channel available for experiments around the world is to probe through muons. No conclusive evidence of CLFV is found so far but $\mutoe$ experiment at Fermi National Accelerator Laboratory (Fermilab) aims to improve the current experimental sensitivity by searching for $\mu^{-}N \longrightarrow e^{-}N$ transition. To provide the high intensity beam that can be handled to achieve desired sensitivity, slow spill using resonant extraction is used at the accelerator complex. Understanding the motivations behind the experiment and simulating the crucial stage in the beam delivery system is the main focus of this thesis. Work presented here will have a qualitative analysis and simulation of resonant extraction at the Delivery Ring (Fermilab), using the beam parameters of $\mutoe$ to study various factors that contribute to the successful beam transport tow ards the Target and Detector System, including meeting intensity requirements while keeping the beam losses to a minimum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recent radial turbine research at the NASA Lewis Research Center

The high efficiencies of small radial turbines led to their application in space power systems and numerous APU and shaft power engines. Experimental and analytical work associated with these systems included examination of blade-shroud clearance, blade loading, and exit diffuser design. Results indicate high efficiency over a wide range of specific speed and also insensitivity to clearance and blade loading in the radial part of the rotor. The exit diffuser investigation indicated that a conventional conical outer wall may not provide the velocity variation consistent with minimum overall diffuser loss.

Rohlik, H. E.↗

Recent radial turbine research at the NASA Lewis Research Center.

The major results obtained in several recent experimental programs on small radial inflow turbines for space applications are presented and discussed. Specifically, experimental and analytical work associated with these systems that has included examination of blade-shroud clearance, blade loading, and exit diffuser design, is considered. Results indicate high efficiency over a wide range of specific speed, and also insensitivity to clearance and blade loading in the radial part of the rotor. The exit diffuser investigation indicated that a conventional conical outer wall may not provide the velocity variation consistent with minimum overall diffuser loss.

Rohlik, H. E.↗

Cascade tests of serrated leading edge blading at high subsonic speeds

Cascade tests of two-dimensional fan rotor blade rows were performed to investigate the effects of leading edge serration on acoustic and aerodynamic performance. The test configurations covered a range of serration tooth geometries. Tests were performed to investigate effects of inlet air angle and velocity on performance. Aerodynamic performance was determined by flow surveys at the mid-span of the blade exit. Acoustic performance was determined by wake turbulence surveys and sound measurements in the semireverberent exhaust chamber. Measured acoustic and aerodynamic performance was comparable and indicated that a serration length of about six percent blade chord yields minimum noise generation and minimum total pressure losses.

Smith, E. G.↗

A new approach to the minimum weight/loss design of switching power converters

A new technique using the mathematical nonlinear programming ALAG is proposed to facilitate design optimizations of switching power converters. This computer-aided approach provides a minimum weight (or loss) design down to the details of component level and concurrently satisfies all related power-circuit performance requirements. It also provides such design insights as tradeoffs between power loss and system weight as the switching frequency is increased.

Lee, F. C.↗

Metallization for large-area solar cells

In large area, low cost solar cells of any type, the contact and grid structure metallization is an important factor which has an effect on the efficiency of the solar cell and its reliability. The present investigation is concerned with aspects of solar cell efficiency. An optimized metallization design leads to minimum total power loss, which is related to a simultaneous minimization of ohmic voltage drops and of shading of the front surface of the cell by the overlaid metal. The requirements regarding the design for a low-loss metallization pattern for the front surface of large area solar cells are represented by a set of design rules listed in a table. The total shading and voltage drop on such cells can be held to about 5%. However, not every metallization process is suited for meeting the requirements of the low-cost design. The low losses can be achieved only by use of several bus lines containing a bulk conductor, such as a wire.

Wolf, M.↗