Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microwave techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Improved receiver noise calibration for ADMX axion search: 4.54 to 5.41 μeV

Axions are a well-motivated candidate for dark matter. The preeminent method to search for axion dark matter is known as the axion haloscope, which makes use of the conversion of axions to photons in a large magnetic field. Because of the weak coupling of axions to photons, however, the expected signal strength is exceptionally small. To increase signal strength, many haloscopes make use of resonant enhancement and high gain amplifiers, while also taking measures to keep receiver noise as low as possible such as the use of dilution refrigerators and ultra-low-noise electronics. In this paper, we derive the theoretical noise model based on the sources of noise found within a typical axion haloscope receiver chain, using the Axion Dark Matter eXperiment (ADMX) as a case study. We present examples of different noise calibration measurements at 1280 MHz taken during ADMX’s most recent data-taking run. These new results shed light on a previously unidentified interaction between the cavity and Josephson Parametric Amplifier as well as provide a better understanding of the systematic uncertainty on the system noise temperature used in the axion search analysis for this data-taking run. Finally, the consistency between the measurements and the detailed model provide suggestions for future improvements within ADMX and other axion haloscopes to reach a lower noise temperature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Axion Dark Matter from 1.1 to 1.3 GHz with ADMX

Axion dark matter can satisfy the conditions needed to account for all of the dark matter and solve the strong 𝐶⁢𝑃 problem. The Axion Dark Matter eXperiment (ADMX) is a direct dark matter search using a haloscope to convert axions to photons in an external magnetic field. Key to this conversion is the use of a microwave resonator that enhances the sensitivity at the frequency of interest. The ADMX experiment boosts its sensitivity using a dilution refrigerator and near quantum-limited amplifier to reduce the noise level in the experimental apparatus. In the most recent run, ADMX searched for axions between 1.10 and 1.31 GHz to extended Kim-Shifman-Vainshtein-Zakharov sensitivity. This Letter reports on the results of that run, as well as unique aspects of this experimental setup.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microwave resonance lamp absorption technique for measuring temperature and OH number density in combustion environments

A simple technique for simultaneous determination of temperature and OH number density is described, along with characteristic results obtained from measurements using a premixed, hydrogen air flat flame burner. The instrumentation is based upon absorption of resonant radiation from a flowing microwave discharge lamp, and is rugged, relatively inexpensive, and very simple to operate.

Lempert, Walter R.↗

Monthly Oceanic Rainfall Derived from Space-Borne Microwave Data

A technique for estimating monthly oceanic rainfall rate using multi-channel microwave measurements has been developed. This technique is applied to the Special Sensor Microwave Imager (SSM/I) data since 1987 to infer monthly rainfall for the Global Precipitation Climatology Project (GPCP). A modified version of this algorithm is now being applied to the TRMM Microwave Imager (TMI) data. There are three prominent features of this algorithm. First, the knowledge of the form of the rainfall intensity probability density function used to augment the measurements. Second, utilizing a linear combination of the 19.35 and 22.235 GHz channels to deemphasize the effect of water vapor. Third, an objective technique has been developed to estimate the rain layer thickness from the 19.35 and 22.23 5 GHz brightness temperature histograms, TMI data with better spatial resolution and 24 hour sampling (vs. sun-synchronized sampling, which is limited to two narrow intervals of local solar time for DMSP satellites) prompt us to study the similarity and difference between these two rainfall estimates. One year of rainfall data (January to December 1998) are used in this study. The mean differences of these two rain estimates are typically less than 15%. Statistical tests are administrated to evaluate the differences between rainfall estimates from SSM/I and TMI data. Differences between TMI and SSM/I rain estimates are discussed in the context of radiative transfer calculations and rainfall estimate algorithm.

Chang, Alfred T. C.↗

Cavity perturbation techniques for measurement of the microwave conductivity and dielectric constant of a bulk semiconductor material.

Cavity perturbation techniques offer a very sensitive and highly versatile means for studying the complex microwave conductivity of a bulk material. A knowledge of the cavity coupling factor in the absence of perturbation, together with the change in the reflected power and the cavity resonance frequency shift, are adequate for the determination of the material properties. This eliminates the need to determine the Q-factor change with perturbation which may lead to appreciable error, especially in the presence of mismatch loss. The measurement accuracy can also be improved by a proper choice of the cavity coupling factor prior to the perturbation.

Eldumiati, I. I.↗

Antenna coupled photonic wire lasers

Slope efficiency (SE) is an important performance metric for lasers. In conventional semiconductor lasers, SE can be optimized by careful designs of the facet (or the modulation for DFB lasers) dimension and surface. However, photonic wire lasers intrinsically suffer low SE due to their deep sub-wavelength emitting facets. Inspired by microwave engineering techniques, we show a novel method to extract power from wire lasers using monolithically integrated antennas. These integrated antennas significantly increase the effective radiation area, and consequently enhance the power extraction efficiency. When applied to wire lasers at THz frequency, we achieved the highest single-side slope efficiency (~450 mW/A) in pulsed mode for DFB lasers at 4 THz and a ~4x increase in output power at 3 THz compared with a similar structure without antennas. This work demonstrates the versatility of incorporating microwave engineering techniques into laser designs, enabling significant performance enhancements.

42 ENGINEERING↗

N - V –Diamond Magnetic Microscopy Using a Double Quantum 4-Ramsey Protocol

We introduce a double quantum (DQ) 4-Ramsey measurement protocol that enables wide-field magnetic imaging using nitrogen-vacancy (N-V) centers in diamond, with enhanced homogeneity of the magnetic sensitivity relative to conventional single quantum (SQ) techniques. The DQ 4-Ramsey protocol employs microwave-phase alternation across four consecutive Ramsey (4-Ramsey) measurements to isolate the desired DQ magnetic signal from any residual SQ signal induced by microwave pulse errors. In a demonstration experiment employing a 1-μm-thick N-V layer in a macroscopic diamond chip, the DQ 4-Ramsey protocol provides a volume-normalized dc magnetic sensitivity of η V = 34nTHz –1/2 μm 3/2 across a 125 μm × 125 μm field of view, with about 5× less spatial variation in sensitivity across the field of view compared to a SQ measurement. Furthermore, the improved robustness and magnetic sensitivity homogeneity of the DQ 4-Ramsey protocol enables imaging of dynamic broadband magnetic sources such as integrated circuits and electrically active cells.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Remote sensing of precipitation structures using combined microwave radar and radiometric techniques

After reviewing published multiparameter radar observations and their interpretation for microphysical retrieval, the paper presents radiative transfer model simulations performed using radar measurements and a cloud model. The qualitative and quantitative aspects of the remote sensing of precipitation are discussed with particular attention given to the potential of estimating scattering-based ice water path.

Vivekanandan, J.↗

Progress in passive microwave remote sensing - Nonlinear retrieval techniques

A variety of nonlinear retrieval methods have been applied to passive microwave remote sensing problems. These problems can be characterized in part by the degree to which their underlying physics and statistics can be understood and characterized in a simple way. Four examples of varying complexity are considered here; the simplest problem requires only analytic expressions for retrievals, whereas the most complex problem has been handled only with pattern classification techniques. The four examples are: (1) Doppler measurements of winds at 70 to 100 km, (2) retrieval of atmospheric water vapor profiles using the opaque 183-GHz water vapor resonance, (3) retrieval of snow accumulation rate by means of combined theoretical and empirical procedures, and (4) classification of diverse polar terrain by means of pattern recognition techniques.

Staelin, D. H.↗

Observations of microwave continuum emission from air shower plasmas

We investigate a possible new technique for microwave detection of cosmic-ray extensive air showers which relies on detection of expected continuum radiation in the microwave range, caused by free-electron collisions with neutrals in the tenuous plasma left after the passage of the shower. We performed an initial experiment at the Argonne Wakefield Accelerator laboratory in 2003 and measured broadband microwave emission from air ionized via high-energy electrons and photons. A follow-up experiment at the Stanford Linear Accelerator Center in the summer of 2004 confirmed the major features of the previous Argonne Wakefield Accelerator observations with better precision. Prompted by these results we built a prototype detector using satellite television technology and have made measurements suggestive of the detection of cosmic-ray extensive air showers. The method, if confirmed by experiments now in progress, could provide a high-duty cycle complement to current nitrogen fluorescence observations.

79 ASTRONOMY AND ASTROPHYSICS↗

An improved dual-frequency technique for the remote sensing of ocean currents and wave spectra

A two frequency microwave radar technique for the remote sensing of directional ocean wave spectra and surface currents is investigated. This technique is conceptually attractive because its operational physical principle involves a spatial electromagnetic scattering resonance with a single, but selectable, long gravity wave. Multiplexing of signals having different spacing of the two transmitted frequencies allows measurements of the entire long wave ocean spectrum to be carried out. A new scatterometer is developed and experimentally tested which is capable of making measurements having much larger signal/background values than previously possible. This instrument couples the resonance technique with coherent, frequency agility radar capabilities. This scatterometer is presently configured for supporting a program of surface current measurements.

Schuler, D. L.↗

Comparison of 2.8- and 21-cm microwave radiometer observations over soils with emission model calculations

An airborne experiment was conducted under NASA auspices to test the feasibility of detecting soil moisture by microwave remote sensing techniques over agricultural fields near Phoenix, Arizona at midday of April 5, 1974 and at dawn of the following day. Extensive ground data were obtained from 96 bare, sixteen hectare fields. Observations made using a scanning (2.8 cm) and a nonscanning (21 cm) radiometer were compared with the predictions of a radiative transfer emission model. It is shown that (1) the emitted intensity at both wavelengths correlates best with the near surface moisture, (2) surface roughness is found to more strongly affect the degree of polarization than the emitted intensity, (3) the slope of the intensity-moisture curves decreases in going from day to dawn, and (4) increased near surface moisture at dawn is characterized by increased polarization of emissions. The results of the experiment indicate that microwave techniques can be used to observe the history of the near surface moisture. The subsurface history must be inferred from soil physics models which use microwave results as boundary conditions.

Burke, W. J.↗

Vibration Method for Tracking the Resonant Mode and Impedance of a Microwave Cavity

There has been a concerted effort to improve the microwave heating technique for processing materials at high temperature. Improved optimization of the energy transfer from a microwave source to the material being processed is required. A vibration technique is pre- sented to continuously maintain a mode resonance and impedance match between a constant frequency magnetron source and a resonant cavity.

microwave↗

Synergic inversion technique for active and passive microwave remote sensing of the ocean

A unified approach for combining active and passive microwave measurements for remote sensing applications is described. A synergic inversion technique has been developed and applied to the retrieval of geophysical parameters of the ocean surface and of the atmosphere. It is based on the combination of radiometric and radar measurements at the electromagnetic and cell level and not only on the correction of radar measurements by radiometric measurements, or conversely. Such a combination is performed through a common quantity: the bistatic scattering coefficient of the observed surface. This is used in a direct model to simulate combined measurements from active and passive sensors. It requires a rather complete and accurate calculation of the scattering of microwaves by the rough sea surface. Comparisons with experimental models derived for scatterometers and radar altimeters or with data derived from radiometric measurements show that the results of this unified approach are consistent with those from separate microwave sensors, at least for a foam-free sea surface.

Sobieski, Piotr↗

Simplification of Methods for PET Radiopharmaceutical Syntheses

In an attempt to develop simplified methods for radiochemical synthesis of radiopharmaceuticals useful in Positron Emission Tomography (PET), current commercially available automated synthesis apparati were evaluated for use with solid phase synthesis, thin-film techniques, microwave-accelerated chemistry, and click chemistry approaches. Using combinations of these techniques, it was shown that these automated synthesis systems can be simply and effectively used to support the synthesis of a wide variety of carbon-11 and fluorine-18 labeled compounds, representing all of the major types of compounds synthesized and using all of the common radiochemical precursors available. These techniques are available for use to deliver clinically useful amounts of PET radiopharmaceuticals with chemical and radiochemical purities and high specific activities, suitable for human administration.

60 APPLIED LIFE SCIENCES↗

A time domain based method for the accurate measurement of Q-factor and resonance frequency of microwave resonators

We present a novel method to determine the resonant frequency and quality factor of microwave resonators which is faster, more stable, and conceptually simpler than the yet existing techniques. The microwave resonator is pumped with the microwave radiation at a frequency away from its resonance. It then emits an exponentially decaying radiation at its eigen-frequency when the excitation is rapidly switched off. The emitted microwave signal is down-converted with a microwave mixer, digitized, and its Fourier transformation (FT) directly yields the resonance curve in a single shot. Being a FT based method, this technique possesses the Fellgett (multiplex) and Connes (accuracy) advantages and it conceptually mimics that of pulsed nuclear magnetic resonance. We also establish a novel benchmark to compare accuracy of the different approaches of microwave resonator measurements. This shows that the present method has similar accuracy to the existing ones, which are based on sweeping or modulating the frequency of the microwave radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗