Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “micro scale models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

184 records · Page 11

Elevated Aerosol Layers and Their Radiative Impact over Kanpur During Monsoon Onset Period

Accurate information about aerosol vertical distribution is needed to reduce uncertainties in aerosol radiative forcing and its effect on atmospheric dynamics. The present study deals with synergistic analyses of aerosol vertical distribution and aerosol optical depth (AOD) with meteorological variables using multisatellite and ground-based remote sensors over Kanpur in central Indo-Gangetic Plain (IGP). Micro-Pulse Lidar Network-derived aerosol vertical extinction (sigma) profiles are analyzed to quantify the interannual and daytime variations during monsoon onset period (May-June) for 2009-2011. The mean aerosol profile is broadly categorized into two layers viz., a surface layer (SL) extending up to 1.5 km (where sigma decreased exponentially with height) and an elevated aerosol layer (EAL) extending between 1.5 and 5.5 km. The increase in total columnar aerosol loading is associated with relatively higher increase in contribution from EAL loading than that from SL. The mean contributions of EALs are about 60%, 51%, and 50% to total columnar AOD during 2009, 2010, and 2011, respectively. We observe distinct parabolic EALs during early morning and late evening but uniformly mixed EALs during midday. The interannual and daytime variations of EALs are mainly influenced by long-range transport and convective capacity of the local emissions, respectively. Radiative flux analysis shows that clear-sky incoming solar radiation at surface is reduced with increase in AOD, which indicates significant cooling at surface. Collocated analysis of atmospheric temperature and aerosol loading reveals that increase in AOD not only resulted in surface dimming but also reduced the temperature (approximately 2-3 C) of lower troposphere (below 3 km altitude). Radiative transfer simulations indicate that the reduction of incoming solar radiation at surface is mainly due to increased absorption by EALs (with increase in total AOD). The observed cooling in lower troposphere in high aerosol loading scenario could be understood as a dynamical feedback of EAL-induced stratification of lower troposphere. Further, the observed radiative effect of EALs increases the stability of the lower troposphere, which could modulate the large-scale atmospheric dynamics during monsoon onset period. These findings encourage follow-up studies on the implication of EALs to the Indian summer monsoon dynamics using numerical models.

aerosol vertical distribution↗

Simulation Study of a Follow-on Gravity Mission to GRACE

The gravity recovery and climate experiment (GRACE) has been providing monthly estimates of the Earth's time-variable gravity field since its launch in March 2002. The GRACE gravity estimates are used to study temporal mass variations on global and regional scales, which are largely caused by a redistribution of water mass in the Earth system. The accuracy of the GRACE gravity fields are primarily limited by the satellite-to-satellite range-rate measurement noise, accelerometer errors, attitude errors, orbit errors, and temporal aliasing caused by unmodeled high-frequency variations in the gravity signal. Recent work by Ball Aerospace and Technologies Corp., Boulder, CO has resulted in the successful development of an interferometric laser ranging system to specifically address the limitations of the K-band microwave ranging system that provides the satellite-to-satellite measurements for the GRACE mission. Full numerical simulations are performed for several possible configurations of a GRACE Follow-On (GFO) mission to determine if a future satellite gravity recovery mission equipped with a laser ranging system will provide better estimates of time-variable gravity, thus benefiting many areas of Earth systems research. The laser ranging system improves the range-rate measurement precision to approximately 0.6 nm/s as compared to approx. 0.2 micro-seconds for the GRACE K-band microwave ranging instrument. Four different mission scenarios are simulated to investigate the effect of the better instrument at two different altitudes. The first pair of simulated missions is flown at GRACE altitude (approx. 480 km) assuming on-board accelerometers with the same noise characteristics as those currently used for GRACE. The second pair of missions is flown at an altitude of approx. 250 km which requires a drag-free system to prevent satellite re-entry. In addition to allowing a lower satellite altitude, the drag-free system also reduces the errors associated with the accelerometer. All simulated mission scenarios assume a two satellite co-orbiting pair similar to GRACE in a near-polar, near-circular orbit. A method for local time variable gravity recovery through mass concentration blocks (mascons) is used to form simulated gravity estimates for Greenland and the Amazon region for three GFO configurations and GRACE. Simulation results show that the increased precision of the laser does not improve gravity estimation when flown with on-board accelerometers at the same altitude and spacecraft separation as GRACE, even when time-varying background models are not included. This study also shows that only modest improvement is realized for the best-case scenario (laser, low-altitude, drag-free) as compared to GRACE due to temporal aliasing errors. These errors are caused by high-frequency variations in the hydrology signal and imperfections in the atmospheric, oceanographic, and tidal models which are used to remove unwanted signal. This work concludes that applying the updated technologies alone will not immediately advance the accuracy of the gravity estimates. If the scientific objectives of a GFO mission require more accurate gravity estimates, then future work should focus on improvements in the geophysical models, and ways in which the mission design or data processing could reduce the effects of temporal aliasing.

Loomis, Bryant D.↗

Thermodynamic constraints on the textural evolution of eucrite, EET 90020

Basaltic eucrites, which are possibly parts of the Vestan crust, formed as either lava flows or intrusions, and can offer insights into early crust formation. However most eucrites have experienced thermal metamorphism, which exacerbates the challenges of understanding these samples. A variety of petrogenetic models such as, partial melting of a primitive source, fractional crystallization of magmas emplaced in a primitive crust, and/or partial melting of a eucritic source coupled with melt mixing and assimilation have been proposed in order to explain observed petrologic and chemical characteristics of eucrites. EET 90020 is an unbrecciated eucrite that has experienced significant thermal metamorphism, with temperatures of metamorphic equilibration calculated to be ~840-1040°C. Its petrologic history remains contentious, in part due to differences in trace element analyses [10,17, this work], which has led to multiple metamorphic interpretations [8,10-11]. Here, we combined petrologic observations, chemical analyses, and thermodynamic modeling, to interpret micro-domain textures identified in EET 90020 and better constrain its petrologic history. Ultimately, the development of such textures is a direct result of the geologic processes operating on a young Vesta or similar asteroid. Sample description: We identified three textural domains in EET 90020 (Figure 1); (I) A coarse grain domain with granoblastic plagioclase and pyroxene, (II) a medium grain domain with curved grain boundaries between plagioclase and pyroxene, and (III) a fine grain domain dominated by tridymite that fills in interstitial space between spherical plagioclase. Major element chemistry in phases is consistent across domains. Pyroxene have distinctive high Ca lamellae (Wo40.92En28.1Fs31.0) forming from the low-Ca pigeonite host (Wo3.5En33.7Fs62.8). There are small amounts of fayalitic olivine along pyroxene/oxide grain boundaries, where pyroxenes have reacted with ilmenite/chromite clasts. Plagioclase is anorthitic (Avg ~An88), with little variation (An86-92.5). Trace element bulk rock analyses were collected via ICP-MS and individual mineral analyses with LA-ICP-MS (Figure 2). The bulk sample has an observable enrichment in light rare earth elements, with a notable depletion in Eu. Plagioclase is enriched in LREEs, depleted in HREEs, and has a positive Eu anomaly while pyroxene is enriched in HREEs with a negative Eu anomaly. Variations in trace element analyses is likely influenced by the presence of phosphates because are highly enriched in REEs and have a dramatic effect on the bulk domain compositions. Thermodynamic modeling: The software package, Perple_X, was used to calculate mineral phase equilibria over a range of conditions using a Gibbs free energy minimization approach [12]. Models used all major/minor elements except P2O5. Thermodynamic properties from [13] were used to constrain endmember phase stabilities. Activity models were used to describe mixing in phases with solid solution. Isochemical P-T phase diagrams were constructed for the bulk thin section, and the coarse, medium and fine grain domain compositions. Domain compositions were determined using microprobe analyses of phases identified in each domain and observed modal mineral abundancies. Thermodynamically stable pyroxene compositions were extracted from model results and compared to pyroxene compositions collected via EMPA, allowing us to calculate temperatures for metamorphic equilibrium. Results: Results that use the coarse domain composition (Fig. 3a) demonstrate overlap at T ~ 1020°C indicating high T equilibration. There was no overlap for the medium and fine grain domains, or the bulk composition (e.g., Fig. 3b) indicating that these are not equilibrium assemblages. These results were replicated using data from [8,20]. Discussion: The disequilibrium results from the bulk rock, fine grain and medium grain models imply that EET 90020 was modified during and/or after peak metamorphism (open system behavior). However, this is in contrast to the coarse domain where it appears as if equilibrium was maintained. We suggest that this conflict is explained by highly localized equilibrium occurring at millimeter length-scales, which has been observed in terrestrial metamorphism where aqueous fluid infiltrate [14] or melt loss occurs [15]. It is unlikely that aqueous alteration was significant in modifying the bulk composition of EET 90020, because it lacks hydrated minerals. However, the presence of melt is supported by the presence of an abundance of curved grain boundaries and spherical grains in the medium and fine grain domains This contrasts the coarse domain, where grain boundaries are angular. Given the evidence for disequilibrium in the medium and fine grain domains, it would be inappropriate to draw additional conclusions about textural evolution using thermodynamic models of those domains. However, modeling results of the coarse grain domain, where equilibrium was maintained, can provide useful insights into the geologic evolution of EET 90020. We approximate maximum metamorphic temperatures, using the Ca component in pyroxene, at ~1020°C (Fig. 4), which is consistent with previous two-pyroxene thermometry [11]. At this temperature, up to 10 vol % melt can be produced in the coarse grain domain, which is at the boundary of minimum melt needed in order to segregate and form a melt network [16]. Tridymite and plagioclase would be the first minerals to melt out during heating starting ~990°C. This is consistent with the observed melt textures formed by tridymite and plagioclase in the fine grain domain. We suggest that a partial melting model best explains the textural development of EET 90020. Upon heating, melt generated was either trapped, resulting in no net change in the localized rock composition, or migrated, resulting in disequilibrium between pyroxene and the surrounding matrix. A positive Eu anomaly in plagioclase indicates that all of the plagioclase was melted previously. This is consistent with previous studies that have suggested that EET 90020 represents a residual eucrite that experienced partial melting and subsequent melt loss [8]. We speculate that partial melting could have occurred when EET 90020 was heated in the asteroid’s lower crust or adjacent to an intrusion [7]. Future work will study other, texturally heterogeneous samples to see if EET 90020 presents a unique circumstance or whether crustal partial melting was ubiquitous on the eucrite asteroid.

Eucrites↗

The HyMeX Special Observation Period in Central Italy: Precipitation Measurements, Retrieval Techniques and Preliminary Results

The Mediterranean area concentrates the major natural risks related to the water cycle, including heavy precipitation and flash-flooding during the fall season. The capability to predict such high-impact events remains weak because of the contribution of very fine-scale processes and their non-linear interactions with the larger scale processes. These societal and science issues motivate the HyMeX (Hydrological cycle in the Mediterranean Experiment, http://www.hymex.orgl) experimental programme. HyMeX aims at a better quantification and understanding of the water cycle in the Mediterranean with emphasis on intense events. The observation strategy of HyMEX is organized in a long-term (4 years) Enhanced Observation Periods (EOP) and short-term (2 months) Special Observation Periods (SOP). HyMEX has identified 3 main Mediterranean target areas: North-West (NW), Adriatic (A) and South-East (SE). Within each target area several hydrometeorological sites for heavy rainfall and flash flooding have been set up. The hydrometeorological sire in Central Italy (CI) is interested by both western and eastern fronts coming from the Atlantic Ocean and Siberia, respectively. Orographic precipitations play an important role due to the central Apennine range, which reaches nearly 3000 m (Gran Sasso peak). Moreover, convective systems commonly develop in CI during late summer and beginning of autumn, often causing localized hailstorms with cluster organized cells. Western fronts may heavily hit the Tiber basin crossing large urban areas (Rome), whereas eastern fronts can cause flash floods along the Adriatic coastline. Two major basins are involved within Cl region: Tiber basin (1000 km long) and its tributary Aniene and the Aterno-Pescara basin (300 km long). The first HyMeX SOP1.1 was carried out from Sept. till Nov. 2012 in the NW target area The Italian SOP1.1 was coordinated by the Centre of Excellence CETEMPS, University of L'Aquila, a city located in the CI heart. The CI area was covered by a uniquely dense meteorological instrumentation thanks to a synergy between Italian institutions and NASA-GSFC. The following RADARs were operated: a Doppler single-polarization C-band radar located at Mt Midia; the Polar 55C Doppler dual-polarization C-band radar located in Rome; a Doppler C-hand polarimetric radar located at Il Monte (Abnazo); a polarimetric X-band mini-radar in L' Aquila; a polarimetric X-hand portable mini-radar in Rome; a single-polarization X-band mini-radar in Rome. DISDROMETERs were also deployed: 4 Parsivel optical disdrometers in Rome (at Sapienza, CNR-ISAC and CNR-INSEAN); 1 2D-video disdrometer in Rome; 3 Parsivels optical disdrometer respectively in L'Aquila (Abnazo), Avezzano (Abruzzo) and Pescara (Abnazo). Other INSTRUMENTS were available: 1 K-band vertically-pointing micro rain-radar (MRR), 2 Pludix X-band disdrometers, 1 VLF lightning sensor, 1 microwave radiometer at 23-31 GHz in Rome (at Sapienza); the raingauge network with more than 200 stations in Central Italy. Three overpasses in CI were also performed by the Falcon 20 aircraft equipped with the 950Hz cloud radar RASTA Analysis of the SOP1.1 main events in CI will be described by focusing on the raindrop size distribution statistics and its geographical variability. Intercomparison of rainfall estimates from disdrometers, raingauges and radars will be illustrated with the aim to provide a quality-controlled and physically consistent rainfall dataset for meteorological modeling validation and assimilation purposes.

Gatlin, Patrick↗