Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

SU-E-J-06: Additional Imaging Guidance Dose to Patient Organs Resulting From X-Ray Tubes Used in CyberKnife Image Guidance System

Purpose: The use of image-guided radiation therapy (IGRT) has become increasingly common, but the additional radiation exposure resulting from repeated image guidance procedures raises concerns. Although there are many studies reporting imaging dose from different image guidance devices, imaging dose for the CyberKnife Robotic Radiosurgery System is not available. This study provides estimated organ doses resulting from image guidance procedures on the CyberKnife system. Methods: Commercially available Monte Carlo software, PCXMC, was used to calculate average organ doses resulting from x-ray tubes used in the CyberKnife system. There are seven imaging protocols with kVp ranging from 60 – 120 kV and 15 mAs for treatment sites in the Cranium, Head and Neck, Thorax, and Abdomen. The output of each image protocol was measured at treatment isocenter. For each site and protocol, Adult body sizes ranging from anorexic to extremely obese were simulated since organ dose depends on patient size. Doses for all organs within the imaging field-of-view of each site were calculated for a single image acquisition from both of the orthogonal x-ray tubes. Results: Average organ doses were <1.0 mGy for every treatment site and imaging protocol. For a given organ, dose increases as kV increases or body size decreases. Higher doses are typically reported for skeletal components, such as the skull, ribs, or clavicles, than for softtissue organs. Typical organ doses due to a single exposure are estimated as 0.23 mGy to the brain, 0.29 mGy to the heart, 0.08 mGy to the kidneys, etc., depending on the imaging protocol and site. Conclusion: The organ doses vary with treatment site, imaging protocol and patient size. Although the organ dose from a single image acquisition resulting from two orthogonal beams is generally insignificant, the sum of repeated image acquisitions (>100) could reach 10–20 cGy for a typical treatment fraction.

60 APPLIED LIFE SCIENCES↗

Ocean Optics Protocols for Satellite Ocean Color Sensor Validation: Special Topics in Ocean Optics Protocols and Appendices - Volume 6

This document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. The document is organized into 6 separate volumes as Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4. Volume I: Introduction, Background and Conventions; Volume II: Instrument Specifications, Characterization and Calibration; Volume III: Radiometric Measurements and Data Analysis Methods; Volume IV: Inherent Optical Properties: Instruments, Characterization, Field Measurements and Data Analysis Protocols; Volume V: Biogeochemical and Bio-Optical Measurements and Data Analysis Methods; Volume VI: Special Topics in Ocean Optics Protocols and Appendices. The earlier version of Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 3 (Mueller and Fargion 2002, Volumes 1 and 2) is entirely superseded by the six volumes of Revision 4 listed above.

Mueller, J. L.↗

Measurement-induced phase transition in teleportation and wormholes

We demonstrate that some quantum teleportation protocols exhibit measurement induced phase transitions in Sachdev-Ye-Kitaev model. Namely, Kitaev-Yoshida and Gao-Jafferis-Wall protocols have a phase transition if we apply them at a large projection rate or at a large coupling rate respectively. It is well-known that at small rates they allow teleportation to happen only within a small time-window. We show that at large rates, the system goes into a new steady state, where the teleportation can be performed at any moment. In dual Jackiw-Teitelboim gravity these phase transitions correspond to the formation of an eternal traversable wormhole. In the Kitaev-Yoshida case this novel type of wormhole is supported by continuous projections.

Physics↗

SeaWiFS technical report series. Volume 25: Ocean optics protocols for SeaWiFS validation, revision 1

This report presents protocols for measuring optical properties, and other environmental variables, to validate the radiometric performance of the Sea-viewing Wide Field-of-view Sensor (SeaWiFS), and to develop and validate bio-optical algorithms for use with SeaWiFS data. The protocols are intended to establish foundations for a measurement strategy to verify the challenging SeaWiFS uncertainty goals of 5 percent in water-leaving radiances and 35 percent in chlorophyll alpha concentration. The protocols first specify the variables which must be measured, and briefly review the rationale for measuring each variable. Subsequent chapters cover detailed protocols for instrument performance specifications, characterizing and calibrating instruments, methods of making measurements in the field, and methods of data analysis. These protocols were developed at a workshop sponsored by the SeaWiFS Project Office (SPO) and held at the Naval Postgraduate School in Monterey, California (9-12 April 1991). This report began as the proceedings of the workshop, as interpreted and expanded by the authors and reviewed by workshop participants and other members of the bio-optical research community. The protocols are an evolving prescription to allow the research community to approach the unprecedented measurement uncertainties implied by the SeaWiFS goals; research and development are needed to improve the state-of-the-art in specific areas. These protocols should be periodically revised to reflect technical advances during the SeaWiFS Project cycle. The present edition (Revision 1) incorporates new protocols in several areas, including expanded protocol descriptions for Case-2 waters and other improvements, as contributed by several members of the SeaWiFS Science Team.

Hooker, Stanford B.↗

Energy-Resolved Information Scrambling in Energy-Space Lattices

Here, weakly interacting Fermi gases simulate spin lattices in energy space, offering a rich platform for investigating information spreading and spin coherence in a large many-body quantum system. We show that the collective spin vector can be determined as a function of energy from the measured spin density, enabling general energy-space resolved protocols. We measure an out-of-time-order correlation function in this system and observe the energy dependence of the many-body coherence.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-J-16: Planar KV Imaging Dose Reduction Study

Purpose: IGRT has become an indispensable tool in modern radiotherapy with kV imaging used in many departments due to superior image quality and lower dose when compared to MV imaging. Many departments use manufacturer supplied protocols for imaging which are not always optimised between image quality and radiation dose (ALARA). Methods: Whole body phantom PBU-50 (Kyoto Kagaku ltd., Japan) for imaging in radiology has been imaged on Varian iX accelerator (Varian Medical Systems, USA) with OBI 1.5 system. Manufacturer’s default protocols were adapted by modifying kV and mAs values when imaging different anatomical regions of the phantom (head, thorax, abdomen, pelvis, extremities). Images with different settings were independently reviewed by two persons and their suitability for IGRT set-up correction protocols were evaluated. The suitable images with the lowest mAs were then selected. The entrance surface dose (ESD) for manufacturer’s default protocols and modified protocols were measured with RTI Black Piranha (RTI Group, Sweden) and compared. Image quality was also measured with kVQC phantom (Standard Imaging, USA) for different protocols. The modified protocols have been applied for clinical work. Results: For most cases optimized protocols reduced the ESD on average by a factor of 3(range 0.9–8.5). Further reduction in ESD has been observed by applying bow-tie filter designed for CBCT. The largest reduction in dose (12.2 times) was observed for Thorax lateral protocol. The dose was slightly increased (by 10%) for large pelvis AP protocol. Conclusion: Manufacturer’s default IGRT protocols could be optimised to reduce the ESD to the patient without losing the necessary image quality for patient set-up correction. For patient set-up with planar kV imaging the bony anatomy is mostly used and optimization should focus on this aspect. Therefore, the current approach with anthropomorphic phantom is more advantageous in optimization over standard kV quality control phantoms and SNR metrics.

60 APPLIED LIFE SCIENCES↗

Replacement correction factors for plane-parallel ion chambers in electron beams

Purpose: Plane-parallel chambers are recommended by dosimetry protocols for measurements in (especially low-energy) electron beams. In dosimetry protocols, the replacement correction factor P{sub repl} is assumed unity for ''well-guarded'' plane-parallel chambers in electron beams when the front face of the cavity is the effective point of measurement. There is experimental evidence that ion chambers which are not well-guarded (e.g., Markus) have nonunity P{sub repl} values. Monte Carlo simulations are employed in this study to investigate the replacement correction factors for plane-parallel chambers in electron beams. Methods: Using previously established Monte Carlo calculation methods, the values of P{sub repl} are calculated with high statistical precision for the cavities of a variety of plane-parallel chambers in a water phantom irradiated by various electron beams. The dependences of the values of P{sub repl} on the beam quality, phantom depth, as well as the guard ring width are studied. Results: In the dose fall-off region for low-energy beams, the P{sub repl} values are very sensitive to depth. It is found that this is mainly due to the gradient effect, which originates from the fact that the effective point of measurement for many plane-parallel chambers should not be at the front face of the cavity but rather shifted toward the center of the cavity by a fraction of a millimeter. Using the front face of the cavity as the effective point of measurement, the calculated values of P{sub repl} at d{sub ref} are not unity for some well-guarded plane-parallel chambers. The calculated P{sub repl} values for the Roos chamber are close to 1 for all electron beams. The calculation results for the Markus chamber are in good agreement with the measured values. Conclusions: The appropriate selection of the effective point of measurement for plane-parallel chambers in electron beams is an important issue. If the effective point of measurement is correctly accounted for, the P{sub repl} values would be almost independent of depth. Both the guard ring width and the ratio of the collecting volume diameter to the cavity thickness can influence the values of P{sub repl}. For a diameter to thickness ratio of 5 (e.g., NACP02 chamber), the guard width has to be 6 mm for the chamber to be considered as well-guarded, i.e., have a P{sub repl} value of 1.00.

61 RADIATION PROTECTION AND DOSIMETRY↗

Human Factors and Behavioral Performance Exploration Measures Harmonized Across HERA, NEK, and ISS: Teams Risk

BACKGROUNDThe Human Factors and Behavioral Performance Exploration Measures (HFBP-EM) suite is a set of standardized measures to assess behavioral health and performance risk related to future exploration class missions, and to support reduction of the Human Research Program’s (HRP) Behavioral Medicine (BMed), Team, Sleep, and Human Systems Integration Architecture risks. HFBP-EM were collected during Human Exploration Research Analogs (HERA) campaigns 4 (C4) and 5 (C5), and during SIRIUS 17 and 19 missions in the Russian Ground Based Experiment Complex, NEK, to document the feasibility, flexibility, and acceptability of these measures in analogsof the spaceflight environment. A subset of the HFBP-EM suite was collected during spaceflight as part HRP’s Standard Measures in Spaceflight Project. Whenever possible, the HFBP-EM protocol and measures are kept the same across studies, however, differences across research settings (e.g., experimental manipulations, mission scenarios, mission length) and implementation of the measures require the data are harmonized to ensure comparable views across missions. The purpose of our project is to develop a harmonized database of HFBP-EM data from different settings, and to summarize the trajectory of behavioral health and performance within and between research settings. In this presentation, we will summarize the harmonized dataset and the trajectory of measures related to the Team Risk, including team performance, team cohesion, team processes, and psychological safety, over time and between and within settings.METHODSWe followed best practices for data harmonization. Characteristics of each research setting were assessed for harmonization potential, and we deemed NEK-SIRIUS 17 as inappropriate due to study aims, length, and data quality. Common variables of interest were identified. Study characteristics and key variables with which datafiles could be merged were defined as “meta-data.” HFBP-EM data from all settings were processed under a common format. We then created a harmonized team-level database designed to facilitate analyses that address HRP research gaps related to HRP’s Team risk. In this database, team cohesion, processes, performance, psychological safety, and group living were operationalized as the team mean of the crew responses for each data collection (e.g., on mission day 7). Data collected on the International Space Station (ISS) included a subset of scale items administered to participants. Data collected from ISS team members within +/- 7 days of the first data collection and every following 30 +/-4 days were aggregated to the team level. We generated figures that display the mean and variability of team constructs across research settings. We also generated plots of changes in team constructs with mission day and with percentage of the mission completed. Where possible, we compared data from spaceflight analogs with data from astronauts aboard the ISS. RESULTS AND DISCUSSIONThe team-level harmonized database was structured such that each row represents data for a team on a specific mission day. Team constructs (e.g., team cohesion) were included as columns (i.e., wide format) with repeated measures across mission days given in rows (i.e., long format). The database included data from 18 crews: five, 4-person American crews in HERA C4, four 4-person American crews in HERA C5, one 6-person multinational crew in NEK-SIRIUS 19, and eight, 2–11-person multinational crews aboard the ISS. Results provide insights into mission and campaign differences in team functioning and performance. For example, between campaign differences were observed for team processes—the interdependent team actions that orchestrate taskwork in pursuit of the team’s goals [1]. Greater between-team variability on team processes was detected during HERA C4 than during C5, and a downward trend was observed over the duration of C4, but not C5 or SIRIUS 19. This may be due to the campaign-level differences such as the sleep deprivation implemented during C4. Responses on the subset of team process items administered on the ISS indicate between-crew variability more like those observed in C4 than C5 and NEK, with some, but not all ISS crews demonstrating a downward trend over time. Additional findings will be presented. REFERENCESMarks, M. A., et al (2001) Academy of Management Review, 26(3), 356-376.

S T Bell↗

Human Factors and Behavioral Performance Exploration Measures Harmonized Across HERA, NEK, and ISS Teams Risk

The Human Factors and Behavioral Performance Exploration Measures (HFBP-EM) suite is a set of standardized measures to assess behavioral health and performance risk related to future exploration class missions, and to support reduction of the Human Research Program’s (HRP) Behavioral Medicine (BMed), Team, Sleep, and Human Systems Integration Architecture risks. HFBP-EM were collected during Human Exploration Research Analogs (HERA) campaigns 4 (C4) and 5 (C5), and during SIRIUS 17 and 19 missions in the Russian Ground Based Experiment Complex, NEK, to document the feasibility, flexibility, and acceptability of these measures in analogs of the spaceflight environment. A subset of the HFBP-EM suite was collected during spaceflight as part HRP’s Standard Measures in Spaceflight Project. Whenever possible, the HFBP-EM protocol and measures are kept the same across studies, however, differences across research settings (e.g., experimental manipulations, mission scenarios, mission length) and implementation of the measures require the data are harmonized to ensure comparable views across missions. The purpose of our project is to develop a harmonized database of HFBP-EM data from different settings, and to summarize the trajectory of behavioral health and performance within and between research settings. In this presentation, we will summarize the harmonized dataset and the trajectory of measures related to the Team Risk, including team performance, team cohesion, team processes, and psychological safety, over time and between and within settings.

S T Bell↗

Human Factors and Behavioral Performance Exploration Measures Harmonized Across HERA, NEK, And ISS: Behavioral Medicine Risk

The Human Factors and Behavioral Performance Exploration Measures (HFBP-EM) suite is a set of standardized measures used to assess behavioral health and performance risks related to future exploration class space missions. The HFBP-EM addresses the Human Research Program’s (HRP) Behavioral Medicine (BMed), Team, Sleep, and Human Systems Integration Architecture risks. HFBP-EM were collected during Human Exploration Research Analog (HERA) campaigns 4 and 5, and during SIRIUS 17 and 19 missions in the Russian Ground Based Experiment Complex, NEK, to document the feasibility, flexibility, and acceptability of these measures in analogs of spaceflight environments. A subset of the HFBP-EM suite was collected in spaceflight as part of the HRP Standard Measures in Spaceflight Project. Whenever possible, the HFBP-EM protocol and measures are the same across studies, differences across research settings (e.g., experimental manipulations, mission scenarios, and mission length) and implementation of the measures require that the data are harmonized to ensure comparable views across missions. The purpose of our project was to develop a harmonized database of analyzable HFBP-EM data from spaceflight and analog settings, and to summarize the trajectory of behavioral health and performance outcomes within and between mission settings. In this presentation, we will summarize the harmonized dataset and the trajectory of BMed related measures including depression, neurobehavioral function, mood, cognition, and operationally relevant individual performance over time and by campaign and mission.

S T Bell↗

Synthesis, lipid membrane incorporation, and ion permeability testing of carbon nanotube porins

Carbon nanotube porins (CNTPs) are 10- to 20-nm-long segments of lipid-stabilized single-walled carbon nanotubes (CNTs) that can be inserted into phospholipid membranes to form nanometer-scale-diameter pores that approximate the geometry and many key transport characteristics of biological membrane channels. We report on protocols for CNTP synthesis by ultrasound-assisted cutting of long CNTs in the presence of lipid amphiphiles, and for validation of CNTP incorporation into a lipid membrane using a proton permeability assay. Moreover, we describe protocols for measuring conductance of individual CNTPs in planar lipid bilayers and plasma membranes of live cells. The protocol for the preparation and testing of the CNTPs in vesicle systems takes 3 d, and single CNTP conductance measurements take 2–5 h. The CNTPs produced by this cutting protocol remain stable and active for at least 10–12 weeks.

59 BASIC BIOLOGICAL SCIENCES↗

Experimental demonstration of an isotope-sensitive warhead verification technique using nuclear resonance fluorescence

Significance We present an experimental demonstration of an isotope-sensitive warhead verification protocol. The measurement is capable of detecting tampering with a warhead’s material or geometry with high statistical confidence in realistically attainable measurement times, while simultaneously protecting sensitive warhead design information. Such a protocol could enable the verifiable elimination of nuclear warheads under a future arms reduction treaty.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Precision of Four Acoustic Bone Measurement Devices

Though many studies have quantified the precision of various acoustic bone measurement devices, it is difficult to directly compare the results among the studies, because they used disparate subject pools, did not specify the estimation methodology, or did not use consistent definitions for various precision characteristics. In this study, we used a repeated measures design protocol to directly determine the precision characteristics of four acoustic bone measurement devices: the Mechanical Response Tissue Analyzer (MRTA), the UBA-575+, the SoundScan 2000 (S2000), and the Sahara Ultrasound Done Analyzer. Ten men and ten women were scanned on all four devices by two different operators at five discrete time points: Week 1, Week 2, Week 3, Month 3 and Month 6. The percent coefficient of variation (%CV) and standardized coefficient of variation were computed for the following precision characteristics: interoperator effect, operator-subject interaction, short-term error variance, and long-term drift, The MRTA had high interoperator errors for its ulnar and tibial stiffness measures and a large long-term drift in its tibial stiffness measurement. The UBA-575+ exhibited large short-term error variances and long-term drift for all three of its measurements. The S2000's tibial speed of sound measurement showed a high short-term error variance and a significant operator-subject interaction but very good values ( < 1%) for the other precision characteristics. The Sahara seemed to have the best overall performance, but was hampered by a large %CV for short-term error variance in its broadband ultrasound attenuation measure.

Miller, Christopher↗

Precision of Four Acoustic Bone Measurement Devices

Though many studies have quantified the precision of various acoustic bone measurement devices, it is difficult to directly compare the results among the studies, because they used disparate subject pools, did not specify the estimation methodology, or did not use consistent definitions for various precision characteristics. In this study, we used a repeated measures design protocol to directly determine the precision characteristics of four acoustic bone measurement devices: the Mechanical Response Tissue Analyzer (MRTA), the UBA-575+, the SoundScan 2000 (S2000), and the Sahara Ultrasound Bone Analyzer. Ten men and ten women were scanned on all four devices by two different operators at five discrete time points: Week 1, Week 2, Week 3, Month 3 and Month 6. The percent coefficient of variation (%CV) and standardized coefficient of variation were computed for the following precision characteristics: interoperator effect, operator-subject interaction, short-term error variance, and long-term drift. The MRTA had high interoperator errors for its ulnar and tibial stiffness measures and a large long-term drift in its tibial stiffness measurement. The UBA-575+ exhibited large short-term error variances and long-term drift for all three of its measurements. The S2000's tibial speed of sound measurement showed a high short-term error variance and a significant operator-subject interaction but very good values (less than 1%) for the other precision characteristics. The Sahara seemed to have the best overall performance, but was hampered by a large %CV for short-term error variance in its broadband ultrasound attenuation measure.

Miller, Christopher↗

Image-Guided Cryoablation of the Spine in a Swine Model: Clinical, Radiological, and Pathological Findings with Light and Electron Microscopy

PurposeThis study was designed to present the feasibility of an in vivo image-guided percutaneous cryoablation of the porcine vertebral body.MethodsThe institutional animal care committee approved this study. Cone-beam computed tomography (CBCT)-guided vertebral cryoablations (n = 22) were performed in eight pigs with short, 2-min, single or double-freezing protocols. Protective measures to nerves included dioxide carbon (CO{sub 2}) epidural injections and spinal canal temperature monitoring. Clinical, radiological, and pathological data with light (n = 20) or transmission electron (n = 2) microscopic analyses were evaluated after 6 days of clinical follow-up and euthanasia.ResultsCBCT/fluoroscopic-guided transpedicular vertebral body cryoprobe positioning and CO{sub 2} epidural injection were successful in all procedures. No major complications were observed in seven animals (87.5 %, n = 8). A minor complication was observed in one pig (12.5 %, n = 1). Logistic regression model analysis showed the cryoprobe-spinal canal (Cp-Sc) distance as the most efficient parameter to categorize spinal canal temperatures lower than 19 °C (p < 0.004), with a significant Pearson’s correlation test (p < 0.041) between the Cp-Sc distance and the lowest spinal canal temperatures. Ablation zones encompassed pedicles and the posterior wall of the vertebral bodies with an inflammatory rim, although no inflammatory infiltrate was depicted in the surrounding neural structures at light microscopy. Ultrastructural analyses evidenced myelin sheath disruption in some large nerve fibers, although neurological deficits were not observed.ConclusionsCBCT-guided vertebral cryoablation of the porcine spine is feasible under a combination of a short freezing protocol and protective measures to the surrounding nerves. Ultrastructural analyses may be helpful assess the early modifications of the nerve fibers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-AB-BRA-10: Assessment of Fiber Bragg Grating (FBG)-Based Sensing for Real-Time Needle Tracking During MR-Guided Brachytherapy

Purpose: This study assesses the potential of Fiber Bragg Grating (FBG)-based sensing for real-time needle (including catheter or tube) tracking during MR-guided HDR brachytherapy. Methods: The proposed FBG-based sensing tracking approach involves a MR-compatible stylet composed of three optic fibers with nine sets of embedded FBG sensors each. When the stylet is inserted inside the lumen of the needle, the FBG sensing system can measure the needle’s deflection. For localization of the needle in physical space, the position and orientation of the stylet base are mandatory. For this purpose, we propose to fix the stylet base and determine its position and orientation using a MR-based calibration as follows. First, the deflection of a needle inserted in a phantom in two different configurations is measured during simultaneous MR-imaging. Then, after segmentation of the needle shapes on the MR-images, the position and orientation of the stylet base is determined using a rigid registration of the needle shapes on both MR and FBG-based measurements. The calibration method was assessed by measuring the deflection of a needle in a prostate phantom in five different configurations using FBG-based sensing during simultaneous MR-imaging. Any two needle shapes were employed for the calibration step and the proposed FGB-tracking approach was subsequently evaluated on the other three needles configurations. The tracking accuracy was evaluated by computing the Euclidian distance between the 3D FBG vs. MR-based measurements. Results: Over all needle shapes tested, the average(standard deviation) Euclidian distance between the FBG and MR-based measurements was 0.79mm(0.37mm). The update rate and latency of the FBG-based measurements were 100ms and 300ms respectively. Conclusion: The proposed FBG-based protocol can measure the needle position with an accuracy, precision, update rate and latency eligible for accurate needle steering during MR-guided HDR brachytherapy. M. Borot de Battisti is funded by Philips Medical Systems Nederland B.V.; M. Moerland is principal investigator on a contract funded by Philips Medical Systems Nederland B.V.; G. Hautvast and D. Binnekamp are fulltime employees of Philips Medical Systems Nederland B.V.

61 RADIATION PROTECTION AND DOSIMETRY↗

Protocols for Assessing Transformation Rates of Nitrous Oxide in the Water Column

Nitrous oxide (N 2 O) is a potent greenhouse gas and an ozone destroying substance. Yet, clear step-by-step protocols to measure N 2 O transformation rates in freshwater and marine environments are still lacking, challenging inter-comparability efforts. Here we present detailed protocols currently used by leading experts in the field to measure water-column N 2 O production and consumption rates in both marine and other aquatic environments. We present example 15 N-tracer incubation experiments in marine environments as well as templates to calculate both N 2 O production and consumption rates. We discuss important considerations and recommendations regarding (1) precautions to prevent oxygen (O 2 ) contamination during low-oxygen and anoxic incubations, (2) preferred bottles and stoppers, (3) procedures for 15 N-tracer addition, and (4) the choice of a fixative. We finally discuss data reporting and archiving. We expect these protocols will make 15 N-labeled N 2 O transformation rate measurements more accessible to the wider community and facilitate future inter-comparison between different laboratories.

15N-tracer incubations↗