Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Unmanned Aerial Vehicle Path Generation for Image Collection to Assist Heliostat Field Optical Characterization

This paper focuses on applications of unmanned aerial vehicles (UAVs) for measuring optical error of heliostats in concentrating solar power (CSP) plants. In CSP, there is a need to measure solar-field optical errors, which is critical for future production improvement as well as for operations and maintenance of a heliostat field. This latter need is particularly challenging because of the large number of heliostats (over 10,000 for a utility-scale power plant) that individually track the sun in the field. To address this issue, a camera-equipped UAV, with an optimized drone flight path developed and uploaded to it, collects images of a precise reflection of the tower on each heliostat to evaluate optical error sources without interrupting plant operation. Generation of the drone path for capturing the reflected images is affected by a number technical and realistic constraints, which include the camera angle used to capture the image, the blocking of the camera view due to surrounding heliostats, the location of the camera in reference to the target heliostat, and the target heliostat position with reference to the tower. The effect of these constraints on calculating the camera position will be discussed in detail in this article. An effective drone-path algorithm is generated to fulfil the need of image collection under various constraints.

concentrated solar power↗

New measurements of gamma-ray energies and their absolute intensities from the decay of 231 Pa

Accurate nuclear data for the decay of 231 Pa is highly important for non-destructive analysis in the areas of radiochronometry and nuclear forensics. However, the evaluated nuclear data for this isotope is lacking; many previous measurements have large uncertainties and only two measurements are used to determine the absolute intensities. In this work, we present modern measurements of the major gamma-ray emissions from the decay of 231 Pa to 227 Ac including the energies and absolute intensities. For many of these measurements, the error envelopes have been significantly decreased compared to previous measurements, while remaining in good agreement. The absolute intensity of the 283 keV reference line was measured as 0.0163(2).

231Pa↗

The impact of the fiducial cosmology assumption on BAO distance scale measurements

ABSTRACT Standard analysis pipelines for measurements of Baryon Acoustic Oscillations (BAO) in galaxy surveys make use of a fiducial cosmological model to guide the data compression required to transform from observed redshifts and angles to the measured angular and radial BAO peak positions. In order to remove any dependence on the fiducial cosmology from the results, all models compared to the data should mimic the compression and its dependence on the fiducial model. In practice, approximations are made when testing models: (1) There is assumed to be no residual dependence on the fiducial cosmology after reconstruction, (2) differences in the distance–redshift relationship are assumed to match a linear scaling, and (3) differences in clustering between true and fiducial models are assumed to be removed by the free parameters used to null the non-BAO signal. We test these approximations using the current standard measurement procedure with a set of halo catalogues from the aemulus suite of N-body simulations, which span a range of wCDM cosmological models. We focus on reconstruction of the primordial BAO and locating the BAO. For the range of wCDM cosmologies covered by the aemulus suite, we find no evidence for systematic errors in the measured BAO shift parameters α∥ and α⊥ to $\lt 0.1\%$. However, the measured errors $\sigma _{\alpha _{\parallel }}$ and $\sigma _{\alpha _{\bot }}$ show a notable absolute increase by up to +0.001 and +0.002, respectively, in the case that the fiducial cosmology does not match the truth. These effects on the inferred BAO scale will be important, given the precision of measurements expected from future surveys including DESI, Euclid, and WFIRST.

79 ASTRONOMY AND ASTROPHYSICS↗

Heliostat error detection

The present disclosure describes non-intrusive optical (NIO) characterization methods which efficiency measures optical errors (such as mirror surface slope error, mirror canting error, and heliostat tracking error) of a heliostat field. The methods utilize photogrammetry and deflectometry to analyze an image taken of a heliostat to determine optical errors and increase the amount of solar energy delivered by the heliostat to the receiver.

Zhu, Guangdong↗

Optimization of the artificial viscosity in Lagrangian staggered discretization codes. Modeling 1D stand-alone shock - case study

We have developed new measures of errors for numerical shock. The new approach is based on analysis of the structure function, and separation of the errors related to oscillations and shock width, which also include error in the position of the ”center” of the numerical shock. We have demonstrated that those measures correctly characterize the numerical solution. We introduced an objective function in, which both types of errors are weighted, and presented optimal values of the coefficients of the linear and quadratic viscosity for different weights and different Mach numbers.

97 MATHEMATICS AND COMPUTING↗

Errors introduced in fission neutron spectrum measurements using a single reference

Measurements of physical quantities are often made relative to a reference quantity, simplifying the interpretation of the measurement and its uncertainties. However, if applied without careful considerations, this technique can carry with it a significant and complex systematic error that is usually ignored. For example, measurements of continuous neutron spectra relative to a reference spectrum yield a result that does not properly include the important effects of neutron scattering in the experimental environment. These effects act to distort the measured spectrum shape and create notable errors in spectrum-integrated quantities. While this effect is one of a series of known potential sources of systematic error including, but not limited to target impurities, angular distributions, incident beam flux, and others, the error introduced from differences in environmental scattering effects between the reference and desired spectra are frequently overlooked. In this work, we demonstrate the origin of this error using simulated data corresponding to measurements of the neutron-induced prompt fission neutron spectra of 233 U, 235 U, 238 U, and 239 Pu as well as the spontaneous fission neutron spectrum of 252 Cf. Errors in the spectrum shape can be as high as 10%–15% depending on the combination of incident and outgoing neutron energy. The spectrum integral and average spectrum energy also contain errors that change with incident neutron energy and can be as high as ~2%. Although this study is based on simulated data, we also show a method for proving that this error exists in an experimental data set and we show a correction that can be applied to results of this type to obtain a more accurate result, thereby largely removing systematic errors from environmental scattering effects. The potential for these kinds of errors should be considered in measurements producing continuous neutron spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvements in Reflected Target Non-intrusive Assessment (ReTNA)

Accurate optical surfaces are a primary driver of concentrated solar power plant performance. Errors in pointing and tracking mirrors, the canting of individual mirror facets, and the surface slope of the mirror itself can be caused by errors during assembly, transportation, wind loading, gravity, and many other sources. The tools that exist to measure these error sources today largely rely on fringe deflectometry (SOFAST, QDec, others), or photogrammetry with targets attached to the mirror surface. In 2022, NREL presented a new indoor optical measurement system to measure fully assembled heliostats during development and on the assembly line for quality assurance purposes, which has undergone significant development in the last year, including the installation of a new, larger laboratory setup. This system, called ReTNA (Reflected Target Non-intrusive Assessment), uses a printed pattern as a deflectometry target. Using printed pattern features as deflectometry targets instead of fringes allows the software to measure the surface slope in two dimensions, eliminating the need to for changing, projected targets. In the last year, NREL's ReTNA tool has been adapted to use a tall, thin target, that only spans one dimension of the mirror, and a camera moving on an automatic track system. We will present these new developments, including the new setup, target patterns, software methodology for fast, automatic optical analysis, and important lessons learned throughout the process. ReTNA results will be compared to established tools, to establish the uncertainty of this new method. ReTNA leverages recent improvements in computer vision and photogrammetry to remove as much careful calibration from the setup process as possible, making the tool low cost, simple, and portable. While it will not achieve the resolution of a fringe deflectometry system, its advantages make it well suited for CSP evaluation, and allow it to fill a different industry need.

concentrating solar power↗

Experimental Simulations of Field-Induced Mechanical Abuse Conditions

Mechanical failure of cell components is an important component to understanding safety outcomes for batteries subjected to external loading. Several key parameters governing the mechanical response at the component to the module level are discussed in this chapter. Specifically, nuances associated with experimental measurements of these properties – including development of test methods, fixturing the test articles, ways to minimize errors in measurements, and improving the repeatability of some of these experiments – are examined closely.

Torres-castro, Loraine↗

Eddy current flow meter model validation with a moving solid rod*

We report that the eddy current flow meter (ECFM) has been used to measure velocities and temperatures of conductive flows, such as liquid metal flows in a nuclear fission reactor. The goal of this paper is to develop a finite element electromagnetic model that can characterize the ECFM sensor performance and validate this finite element model with detailed velocity measurements of a controlled, well-characterized moving conductive solid rod. Both measurements and modeling were performed for various parameters that are important for ECFM performance such as rod velocity, rod material, ECFM sensor coil length, number of sensor coils, applied alternating current (AC) current amplitude, and applied ECFM AC frequency. For all parametric scans, the measurement and modeling agree well in both magnitude and trend. The normalized root-mean-square error between measurement and modeling is less than 10% for all cases. These results suggest that electromagnetic modeling could eventually be used to cost-effectively design future ECFM sensors in arbitrary geometry for more challenging applications such as liquid metal nuclear fission reactors.

47 OTHER INSTRUMENTATION↗

Variation in surface properties as error sources in dynamic temperature measurements

Most temperature measurement methods rely upon the assumption of a single uniform source as part of the analysis in inferring an observed temperature T from the surface of a material. This is true for the radiometric and spectroscopic methods we rely upon in shock physics. However, there are obvious cases where this is a poor assumption that can cause large errors in analysis, such as the measurement of emission from a surface composed of more than one material, such as a rusted surface of Fe and Fe 2 O 3 , or a multi-material surface that could be produced through alloying methods (e.g., mokume gane) or 3D printing. Here we perform an initial examination of the effects of varied surface properties upon the analysis using idealized test data to constrain when we may have better confidence in the resulting calculations. We also examine the structures of the fits to test whether, in principle, comparing the fit with ideal gray bodies would reveal such a structure and enable the researcher to identify when a two-temperature fitting model should be used instead of a single- T model or a wavelength-dependent emissivity model.

36 MATERIALS SCIENCE↗

Binary classification with noisy quantum circuits and noisy quantum data

We study the effects of single-qubit noises in the quantum circuit and the corruption in the quantum training data to the performance of binary classification problem. We find that under the presence of errors, the measurement at a qubit is affected only by the noise in the corresponding qubit, and that the errors on other qubits do not affect this outcome. Furthermore, for the task where we fit a binary classifier using a quantum training data, we show that the noise in the data can work as a regularizer, implying that we can benefit from the noise in certain cases. We support our findings with simulations.

Lee, Yonghoon↗

An Internal Digital Image Correlation Technique for High-Strain Rate Dynamic Experiments

Full-field, quantitative visualization techniques, such as digital image correlation (DIC), have unlocked vast opportunities for experimental mechanics. However, DIC has traditionally been a surface measurement technique, and has not been extended to perform measurements on the interior of specimens for dynamic, full-scale laboratory experiments. This limitation restricts the scope of physics which can be investigated through DIC measurements, especially in the context of heterogeneous materials. The focus of this study is to develop a method for performing internal DIC measurements in dynamic experiments. The aim is to demonstrate its feasibility and accuracy across a range of stresses (up to 650 MPa), strain rates (10 3 - 10 6 s -1 ), and high-strain rate loading conditions (e.g., ramped and shock wave loading). Internal DIC is developed based on the concept of applying a speckle pattern at an inner-plane of a transparent specimen. The high-speed imaging configuration is coupled to the traditional dynamic experimental setups, and is focused on the internal speckle pattern. During the experiment, while the sample deforms dynamically, in-plane, two-dimensional deformations are measured via correlation of the internal speckle pattern. In this study, the viability and accuracy of the internal DIC technique is demonstrated for split-Hopkinson (Kolsky) pressure bar (SHPB) and plate impact experiments. The internal DIC experimental technique is successfully demonstrated in both the SHPB and plate impact experiments. In the SHPB setting, the accuracy of the technique is excellent throughout the deformation regime, with measurement noise of approximately 0.2% strain. In the case of plate impact experiments, the technique performs well, with error and measurement noise of 1% strain. The internal DIC technique has been developed and demonstrated to work well for full-scale dynamic high-strain rate and shock laboratory experiments, and the accuracy is quantified. Here, the technique can aid in investigating the physics and mechanics of the dynamic behavior of materials, including local deformation fields around dynamically loaded material heterogeneities.

36 MATERIALS SCIENCE↗

An Accurate, Error-Tolerant, and Energy-Efficient Neural Network Inference Engine Based on SONOS Analog Memory

In this work, we demonstrate SONOS (silicon-oxide-nitrideoxide- silicon) analog memory arrays that are optimized for neural network inference. The devices are fabricated in a 40nm process and operated in the subthreshold regime for in-memory matrix multiplication. Subthreshold operation enables low conductances to be implemented with low error, which matches the typical weight distribution of neural networks, which is heavily skewed toward near-zero values. This leads to high accuracy in the presence of programming errors and process variations. We simulate the end-to-end neural network inference accuracy, accounting for the measured programming error, read noise, and retention loss in a fabricated SONOS array. Evaluated on the ImageNet dataset using ResNet50, the accuracy using a SONOS system is within 2.16% of floating-point accuracy without any retraining. The unique error properties and high On/Off ratio of the SONOS device allow scaling to large arrays without bit slicing, and enable an inference architecture that achieves 20 TOPS/W on ResNet50, a >10× gain in energy efficiency over state-of-the-art digital and analog inference accelerators.

97 MATHEMATICS AND COMPUTING↗

Universal framework for simultaneous tomography of quantum states and SPAM noise

We present a general denoising algorithm for performing simultaneous tomography of quantum states and measurement noise. This algorithm allows us to fully characterize state preparation and measurement (SPAM) errors present in any quantum system. Our method is based on the analysis of the properties of the linear operator space induced by unitary operations. Given any quantum system with a noisy measurement apparatus, our method can output the quantum state and the noise matrix of the detector up to a single gauge degree of freedom. We show that this gauge freedom is unavoidable in the general case, but this degeneracy can be generally broken using prior knowledge on the state or noise properties, thus fixing the gauge for several types of state-noise combinations with no assumptions about noise strength. Such combinations include pure quantum states with arbitrarily correlated errors, and arbitrary states with block independent errors. This framework can further use available prior information about the setting to systematically reduce the number of observations and measurements required for state and noise detection. Our method effectively generalizes existing approaches to the problem, and includes as special cases common settings considered in the literature requiring an uncorrelated or invertible noise matrix, or specific probe states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-fidelity remote entanglement of trapped atoms mediated by time-bin photons

Abstract Photonic interconnects between quantum processing nodes are likely the only way to achieve large-scale quantum computers and networks. The bottleneck in such an architecture is the interface between well-isolated quantum memories and flying photons. We establish high-fidelity entanglement between remotely separated trapped atomic qubit memories, mediated by photonic qubits stored in the timing of their pulses. Such time-bin encoding removes sensitivity to polarization errors, enables long-distance quantum communication, and is extensible to quantum memories with more than two states. Using a measurement-based error detection process and suppressing a fundamental source of error due to atomic recoil, we achieve an entanglement fidelity of 97% and show that fundamental limits due to atomic recoil still allow fidelities in excess of 99.9%.

Science & Technology - Other Topics↗

Validation of Hygrothermal Simulations with Wall Performance Experiments in an Environmental Chamber

Oak Ridge National Laboratory is developing a web tool, built on a rule-based expert system, that aids stakeholders in designing energy-efficient moisture-durable walls. Currently, the tool’s expert system database is mostly populated with expert opinion, but work is being done to incorporate durability assessment based on stochastic hygrothermal modeling. Chamber experiments have been conducted to validate the hygrothermal models. The measured temperature and humidity have been compared with those predicted by the hygrothermal model. Experiments and comparison to one-dimensional hygrothermal modeling results were completed with two walls, a Structural Insulated Panel (SIP) based wall and a Concrete Masonry Unit (CMU) based wall. The two walls were succumbed to typical Chicago weather in ORNL’s Heat, Air and Moisture chamber. The walls were sequentially exposed to different scenarios, including diffusion, wetting, air leakage and solar radiation. For the most part, the hygrothermal simulations can be successfully used to predict the performance of these wall systems for the moisture transport phenomenon. Errors between measured and simulated values decreased as measurements got closer to the interior side of the wall. The root mean square error was larger for relative humidity (up to 17.5%-RH for CMU) than for temperature (up to 4.5°C for CMU wall). The errors were larger for the CMU wall than the wood frame wall. The phenomenon, including liquid water, caused large discrepancies between measurement and simulation results, and simulated results showed slower drying of materials than measured results. The one-dimensional nature of the simulation model made simulating air leaks difficult but not impossible.

Salonvaara, Mikael↗

Novel application of neutrinos to evaluate U.S. nuclear weapons performance

There is a growing realization that neutrinos can be used as a diagnostic tool to better understand the inner workings of a nuclear weapon. Robust estimates demonstrate that an Inverse Beta Decay (IBD) neutrino scintillation detector built at the Nevada Test Site with a 1000-ton active target mass at a standoff distance of 500 m would detect thousands of antineutrino events per nuclear test. This would provide less than 4% statistical error on the measured antineutrino rate and 5% error on antineutrino energy. Extrapolating this to an error on the test device explosive yield requires knowledge from evaluated nuclear databases, non-equilibrium fission rates, and assumptions on internal neutron fluxes. Initial calculations demonstrate that the total number of neutrinos emitted per fission in the first 10 3 s after a short pulse of 239 Pu fission is about a factor of two less than that from Pu fissioning under steady state conditions. Furthermore, there are significant energy spectral differences as a function of time after the pulse that must be considered. These and other model dependencies will be discussed in the paper. In the absence of nuclear weapons testing, many of the technical and theoretical challenges of a full nuclear test could be mitigated with a low cost smaller scale 20 ton fiducial mass IBD demonstration detector placed near a pulsed reactor. Potential reactors include the Texas A&M University TRIGA 1 GW–10 ms pulsed facility or the Sandia Annular Core Research Reactor. The short duty cycle and repeatability of pulses would provide critical real environment testing and measurements, which would be valuable for planning a possible real test shot in the future. Furthermore, the antineutrino rate as a function of time data would provide unique constraints on fission databases and model assumptions. Finally, there are impactful science drivers such as sensitive searches for ∼1 eV 2 sterile neutrinos and ∼MeV scale axions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Towards a new generation long trace profiler LTP-2020: optical design of pencil beam interferometry sensor

Improvements in the quality of synchrotron beamline x-ray optics required for next-generation light sources (e.g. the ALS Upgrade project) drive the need to improve the performance of the metrology instrumentation used to measure these components. The Long Trace Profiler (LTP) that is in use at many synchrotron metrology laboratories around the world has some known issues that affect the accuracy of its measurements. The main error source is optical path difference (OPD) phase error introduced into the probe beam by inhomogeneities in the glass components used in the optical head. We have developed a new optical head design, LTP-2020, that replaces the cube polarizing beamsplitter (PBS) with a thin wedge plate polarizing beamsplitter (WPBS) and replaces the cemented doublet lens with an aspheric singlet. Both of these components significantly reduce the glass volume traversed by the laser probe beam. Careful attention to ghost ray interference produced by back reflection from optical surfaces is necessary to minimize distortion in the primary image that translates into systematic error in the slope angle measurement. We make extensive use of a commercial raytracing program to model the back reflections and adjust component parameters as necessary to minimize distortion. Deliberate misalignment of components is necessary to make the system perform correctly. Stringent requirements are placed on the 45◦ incidence coatings on the WPBS and on the normal incidence coatings on the lens and camera window elements. We encourage our colleagues who wish to upgrade their current LTP systems to join us in the procurement of these custom optical components.

Takacs, Peter Z.↗