Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “maximum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Maximum Cs-137 Curie Loading onto Crystalline Silicotitanate for the Documented Safety Analysis of the Tank Side Cesium Removal Platform

The Tank Side Cesium Removal (TSCR) system is currently being constructed to process Hanford tank waste supernates for vitrification. TSCR incorporates a filtration system and cesium (Cs) removal system using columns filled with crystalline silicotitanate (CST) ion exchanger, produced by Honeywell UOP, LLC. The documented safety analysis (DSA) developed for TSCR limits a single column curie loading to 141,600 Ci; given a 137 Cs isotopic mass fraction of 20% and the planned CST bed size of a TSCR column, this equates to 0.10 mmole Cs per g CST. Factors that influence 137Cs loading onto the CST include, but are not limited to, CST production lot (different production lots behave differently), contact temperature, contact duration, 137Cs mass fraction, and competitors in the tank waste feed. Seventeen tank waste feeds (compositions) were identified by Washington River Protection Solutions to be processed through TSCR. These feed compositions were used to develop a simulant (referred to herein as Stage 1) that would provide an upper bound to the Cs loading onto CST based on maximizing the Cs/Na activity coefficient ratios in solution while maintaining Na at no less than 5.0 M. Building upon this Stage 1 simulant, a series of four additional simulants were developed based on the cationic/anionic species that impact Cs exchange, with each successive formulation relaxing one or more matrix component concentration constraints as show in Table S.1

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Maximum Interior Voltage and Magnetic Field Penetration Through a Ferromagnetic Layer

This report examines the problem of magnetic penetration of a conductive layer, including nonlinear ferromagnetic layers, excited by an electric current filament. The electric current filament is, for example, a nearby wire excited by a lightning strike. The internal electric field and external magnetic field are determined. Numerical results are compared to various analytical approximations to help understand the physics involved in the penetration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and Production for Maximum Structural Efficiency With Respect to Fiber Orientation With Increased Understanding of Hybrid Fiber Flow Behavior

Discontinuous fiber-reinforced thermoplastic composites have gained considerable attention in automotive, aerospace, and other industries, due to their high-rate of production combined with their ability to attain complex and intricate shapes. Among other high-rate thermoplastic manufacturing processes, injection-molding is one of the most common manufacturing methods due to fast production and high surface finishing of complex geometries. Fiber orientation in discontinuous fiber composites plays a pivotal role in determining the mechanical, electrical, and thermomechanical properties, underscoring the necessity to comprehend fiber orientation in injection molded parts. Among different fiber types, glass and carbon fibers are most common in the composite industries. The recent trend of hybrid composites comprising both glass fiber (GF) and carbon fiber (CF) is also gaining importance in the automotive industry. Hybrid fiber options allow designers to optimize the balance between glass and carbon fibers by leveraging the high durability and low cost of GF while the strength and lightweight properties of CF. Consequently, comparing the fiber oriented distribution (FOD) of injection molded composites containing GF, CF, and a hybrid of GF/CF is critical to investigating the local mechanical properties of intricate structures for high-end applications. In Phase I of this project, FOD in injection-molded panels with respect to distance from the gate was analyzed using X-ray computed tomography (X-CT) for GF, CF, and hybrid CF/GF (CGF) reinforced nylon 66. To understand the reason behind the FOD with different fiber types, computational fluid dynamics (CFD) and rheology were performed. Samples were extracted at three locations: near the gate, center, and opposite end. Thickness of the layers of typical skin-shell-core type FOD varies with fiber type and location. GF achieved flow direction alignment (in shell) earlier than viscous CF and CGF near the gate, whereas CF showed the highest flow-direction alignment at the center due to shear induced orientation. At the opposite end, GF experienced more backflow than others indicating faster mold filling owing to its lower viscosity. Hybrid CGF exhibited GF-dominated center and CF-dominated end region. The numerical model used to obtain FOD and rheological predictions for the CF and GF composites served to corroborate the trends observed in the experimental trials. The FOD responses across fiber types and location were reflected in their longitudinal and transverse properties. Only GF showed higher longitudinal modulus over transverse modulus near the gate attributed to rapid alignment, whereas CF and CGF exhibited opposite trend. However, fountain flow enhanced the longitudinal modulus over transverse modulus with the distance for all, particularly for CF. This study offers insights into mold filling behavior of different fibers which are critical in optimizing injection molding conditions for tailored final properties.

36 MATERIALS SCIENCE↗

“Max-tech FHR”: What is the maximum technically achievable water delivery capacity from a single 120 V plug?

Electrifying water heating will require affordable, direct drop-in replacements for existing gas water heaters that meet consumer expectations for hot water delivery. For many replacement scenarios, affordability requires a replacement option with like-for-like physical product dimensions, and existing consumer expectations presume a large delivery capacity from a small water heater. This work explores the technical potential for hot water delivery capacity for a heat pump water heater (HPWH) powered from a common 120 V plug. Delivery capability in this work is quantified by two metrics: the First Hour Rating (FHR) defined in the Code of Federal Regulations, and a real-world draw profile that resulted in hot water runout during field studies of 120 V HPWHs. The work focuses on the common “tall-and-slim” gas water heater product category, with external product dimensions of 20 inch diameter and 60 inch height. Using a simulation model in DOE/ORNL Heat Pump Design Model, validated by experimental baseline testing of a commercially available 120 V HPWH model, several measures were evaluated to maximize the delivery capacity of a 120 V HPWH. The 120 V HPWH was constrained by 1) external product dimensions of 20 in diameter and 60 inch height, 2) electrical power of 1.5 kW (85% of the available power from a dedicated 120 V, 15 A circuit), and 3) commercially-available components. The measures implemented included a large compressor, a pumped loop with plate heat exchanger to maximize tank stratification, enlarged heat exchangers, and relatively thin insulation to maximize the water storage volume.

Gluesenkamp, Kyle↗

Characterization and CST Batch Contact Equilibrium Testing of Modified Tank 9H Process Supernate Samples in Support of TCCR

The Tank Closure Cesium Removal (TCCR) system uses ion exchange columns filled with crystalline silicotitanate (CST) media to process radioactive waste solutions for the removal of ¹³⁷Cs. TCCR currently focuses on dissolving Savannah River Site (SRS) radioactive tank waste (primarily sodium saltcake solids) within Tank 10H followed by at-tank ion exchange column treatment. Two supernate batches from Tank 10H have been processed through the TCCR unit and processing of a third batch is expected soon. After processing of this supernate batch, plans are to replace the CST columns and process dissolved salt solution from Tank 9H through Tank 10H and then through the new CST columns installed in the TCCR unit. The new columns are expected to contain either a media similar to an archived CST batch (IE-911) or the R9120-B CST media used in the current TCCR columns (the two materials are fundamentally the same; just different specifications, product names, and preconditioning steps). Samples of Tank 9H dissolved saltcake were received at the Savannah River National Laboratory (SRNL) and characterized. The Tank 9H supernate contained a high sodium concentration (~9.6 M Na⁺) and will require dilution to near 6 M [Na⁺] prior to processing through the TCCR unit. The cesium concentration in Tank 9H is currently significantly higher than was observed with Tank 10H. Three dilutions of the Tank 9H supernate were conducted to mimic possible dilutions that could be conducted in the tank farm prior to TCCR processing using inhibited water, sodium hydroxide, and sodium nitrate solutions. Dilution #1 was prepared by diluting the Tank 9H supernate by a factor of 1.6 with inhibited water, Dilution #2 was prepared by diluting the Tank 9H supernate by a factor of 3.7 with a mixed sodium hydroxide/sodium nitrate diluent, and Dilution #3 was prepared by also diluting by a factor of 3.7 but with sodium hydroxide only. All three dilutions have similar Na⁺ concentrations (~6 M), but Dilutions #2 and #3 contain significantly less cesium. Major and key minor components of the diluted Tank 9H supernate samples are provided in Table ES-1. Batch contact equilibrium tests were conducted with the Tank 9H dilutions and the two different CST media batches being considered for use in the new TCCR columns. Results are summarized in Table ES-2 and compared to ZAM model predictions. The highest cesium distribution coefficient and percent removal were observed with Dilution #3. IE-911 CST (an archived CST media batch) was more effective at removing cesium than the more recently prepared R9120-B CST media, though both media samples removed >88% of the cesium and the differences may not be statistically different considering the overall uncertainty. Based on the results, maximum cesium loadings were calculated for each CST media type and Tank 9H dilution. In general, maximum cesium loadings from dilutions of this supernate batch are quite high (approaching 0.1 mmol total Cs⁺/g CST for Dilution #1). The highest calculated maximum ¹³⁷Cs loading for the Tank 9H dilutions using the ZAM model with input of the tank compositions and batch contact results was 207 Ci/kg CST (Dilution #1 with IE-911 CST). In all cases, higher maximum cesium loading values were predicted for IE-911 CST versus R9120-B, although the differences varied considerably between the dilutions. The maximum loading value for IE-911 CST with Tank 9H Dilution #1 was only 7% higher than the maximum loading for R9120-B. The maximum loading value for IE-911 CST with Dilution #3 was 24% higher than the maximum loading for R9120-B. Dilution #2 was intermediate between these values. Note that these maximum loading values are the theoretical calculated values, and actual operating conditions will cause differences. A CST binder dilution (correction) factor near 0.7 (relative to pure powder CST) was required for each batch contact test with IE-911 engineered CST using the three Tank 9H dilutions. Correction factors calculated for R9120-B CST ranged from 0.56 to 0.66 for the three dilutions. Following the batch contact tests, the CST samples were isolated from the Tank 9H solution, washed, dried, and digested in acid following established procedures. The analysis results are provided in Table ES-3. Total cesium loading values determined by CST digestion were similar to the calculated loading values based on solution analysis (Table ES-2) for all samples. In addition, the CST was observed to load calcium (R9120-B sample only), iron, strontium, lead, uranium, and plutonium after contact with the waste supernate, as has been observed previously.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Physical Properties of Hilti HIT-RE 500 V3 After Irradiation: Slant Shear, Tensile, Flexural, and Compressive

There are various applications in which epoxy adhesives may be used within hot-cell environments. These epoxies currently see limited use within hot cells since it is known that organics see degradation after small doses even as low as 50 kilogray (kGy). These losses in physical property strengths limit the use of these epoxies to non-structural applications. In modern construction, however, the use of epoxies to bond structural components such as rebar or threaded anchors is becoming increasingly prevalent. To employ these types of materials the Idaho National Laboratory (INL) has begun investigating the specific degradation properties of epoxies for use in structural applications in environments where radiation is present. Hilti HIT-RE 500 V3 is used extensively in new construction and renovation projects across the world. The INL has conducted various tests on this epoxy for low dose environments. These tests include tensile, flexural, compression, and slant shear tests following the American Society for Testing Material International (ASTM) standards D638, D790, D695, and C882/882M respectively. Two sample sets for each test were created where the baseline specimens were not irradiated, and another set was irradiated to an accumulated dose of approximately 50-60 kGy. All the samples were destructively tested and analyzed focusing on the change in physical properties, examples of these tests are shown in Figures 1-4. Tensile testing results indicate a 0.9% loss in maximum load capacity, a 0.5% loss in tensile stress at maximum load, a 1.4% loss in tensile strain at break, and a 15% decrease in modulus of elasticity. Flexural testing results display an increase in all the following: 12% in strain at maximum load, 10% in maximum load capacity, 5% in stress at maximum load, and 3% in young’s modulus. The compressive physical properties after irradiation display a 1% increase in maximum load, a 3% decrease in stress at yield, and a 5% decrease in modulus of elasticity. The maximum compressive stress saw no measurable change after irradiation. The slant shear specimens after irradiation displayed a 2% increase in maximum load capacity and maximum compressive stress. Though a structural analysis would have to be completed as is normal for building design the increases and decreases in the measured physical properties indicate that this material may be used for structural applications in low dose hot-cell environments without adhesive failure.

36 MATERIALS SCIENCE↗

A Climatology and Extreme Value Analysis of Large Hail in China

In this paper, hail size records are analyzed at 2254 stations in China and a hail size climatology is developed based on gridded hail observations for the period 1960–2015. It is found that the annual percentiles of hail size records changed sharply and national-wide after 1980, therefore two periods, 1960–79 and 1980–2015, are studied. There are some similarities between the two periods in terms of the characteristics of hail size such as the spatial distribution patterns of mean annual maximum hail size and occurrence week of annual maximum hail size. The 1980–2015 period had higher observation density than the 1960–79 period, but showed smaller mean annual maximum hail size, especially in northern China. In the majority of grid boxes, the annual maximum hail size experienced a decreasing trend during the 1980–2015 period. A Gumbel extreme value model is fitted to each grid box to estimate the return periods of maximum hail size. The scale and location parameter of the fitted Gumbel distributions are higher in eastern China than in western China, thereby reflecting a greater likelihood of large hail in eastern China. In southern China, the maximum hail size exceeds 127 mm for a 10-yr return period, whereas in northern China maximum hail size exceeds this threshold for a 50-yr return period. Furthermore, the Gumbel model is found to potentially underestimate the maximum hail size for certain return periods, but provides a more informed picture of the spatial distribution of extreme hail size and the regional differences.

54 ENVIRONMENTAL SCIENCES↗

Characterizing peak electricity demand for U.S. households: an assessment of end-use loads and demand factors

Understanding household peak electricity demand is critical to evaluate the technical need for electrical infrastructure upgrades. This study characterizes peak loads for existing and new equipment using metered data from a convenience sample of 11,940 U.S. dwellings from four sources, including 911 from two sources with end-use metering. After standardized data cleaning and labeling, we derived descriptive statistics for key metrics, such as maximum demand and demand factors, and developed predictive models relating 60- to 15-min demand for the National Electrical Code (NEC). Mean 15-min maximum demand was 9.7 kW (median 9.0 kW; IQR 7.0–11.5 kW, 95% CI 9.6–9.8 kW), indicating spare capacity in 98% of homes with hypothetical 100 A panels. Maximum demand increased with floor area and number of high-demand loads. Dwelling maximum demand was driven by higher-power, longer-duration heating appliances and vehicle charging, while most user-operated appliances contributed little. Demand factors are used to account for how most devices contribute less than their rated power to maximum demand. Existing load mean demand factors (28%; median 10%; IQR 0–58%; CI 28–29%) were higher than those for new loads (21%; median 7%; IQR 0–35%; CI 20–21%), because new loads changed the timing and magnitude of maximum demand. New high-demand loads had higher than average demand factors (40–60%). Whole dwelling demand factors support the NEC's 40% assumption, but they challenge its conservative 100% treatment of new HVAC. We propose a data-driven 50% demand factor for new equipment, which would align with metered data, improve affordability, and modernize electrical codes.

Appliances↗

Simulating the effects of warm O + ions on the growth of electromagnetic ion cyclotron (EMIC) waves

Electromagnetic ion cyclotron (EMIC) waves are believed to play a crucial role in the dynamics of the Earth’s magnetosphere. It has been widely accepted that plasma compositions can influence the growth rate of EMIC waves in the inner magnetosphere, but how warm O + ions change the wave growth rate is not well known. In this study, we investigate the impact of ring current O + concentration on the EMIC growth rate during a specific storm when the O + ion flux significantly increases. We calculate the growth rate of EMIC waves by using physics-based ion distributions output from the Ring current–Atmosphere interactions Model with Self-Consistent magnetic (B) and Electric (E) fields (RAM-SCBE) model. The percentage of warm O + is parametrically varied to examine how the maximum EMIC growth rate changes over time and how the global distribution of the maximum EMIC growth rate is affected. We found that the maximum growth rate of H-band appears in the dusk-to-midnight sector near the plasmapause, while O-band is excited at a slightly outer region. The maximum growth rate of He-band is closely related to the cold plasma density. With the increase of warm O + density, the maximum growth rate of H-band and He-band EMIC wave is reduced, while that of O-band EMIC wave is increased, and the region with this wave excitation is widened. Furthermore, such variation in the maximum EMIC growth rate implies a potential impact on the associated wave–particle interactions and change of the decay rate in the ring current.

79 ASTRONOMY AND ASTROPHYSICS↗