Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “long-duration storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

188 records · Page 11

Pumped-Thermal Electricity Storage Based on Brayton Cycles

Pumped-thermal electricity storage (PTES) based on a reversible (Joule-)Brayton cycle is a promising grid-scale energy storage technology, whose working principle is to store electricity in the form of high-grade thermal energy. This chapter provides an overview of the inner workings, operating principle and current development status of the many PTES variants, as proposed to date in the scientific literature or by manufacturers. The potential and competitiveness of the various candidate designs is quantified by - and discussed thanks to the definition of - specific techno-economic indicators. Investment cost and thermodynamic performance estimates are reported and used to assess the value of this technology as a potential large-scale, long-duration and long-lifetime energy storage option with unique sector-coupling features and low geographical constraints.

electricity storage↗

Techno-Economic Evaluation of a 600MW Pumped Storage Hydropower Plant using the Pumped Storage Hydropower Valuation Tool

This paper presents a techno-economic evaluation of the proposed 600 MW, 8-hour Craig – Hayden pumped storage hydropower project using the U.S. Department of Energy’s Pumped Storage Hydropower Valuation Tool. The analysis integrates plant technical characteristics, regional grid conditions, and market-based operating assumptions to quantify stacked value streams from energy arbitrage, capacity, ancillary services, transmission congestion relief, and reliability. Both price taker and price influencer frameworks are applied to examine the impact of market participation and system interactions on lifecycle economic performance using Benefit - Cost Analysis and Multi - Criteria Decision Analysis. The results show that the price taker approach provides higher revenue estimates based on exogenous price signals, while the price influencer approach captures production cost savings, renewable curtailment reduction, and market price formation, yielding more conservative but system-representative outcomes. The study demonstrates the strategic value of long-duration PSH for enhancing operational flexibility, resource adequacy, and grid reliability in a high-renewable Western Interconnection.

Bhattacharyya, Arjun [ORNL] (ORCID:000900060976046↗

Technical Performance of Refractory Liners for Molten Chloride Salt Thermal Energy Storage Systems

A chloride-based molten-salt system that uses a ternary blend of MgCl2/KCl/NaCl is investigated to provide higher temperature thermal energy storage capability. Despite higher thermal stability, molten chlorides present several unique challenges, including the design of internal refractory-ceramic liners to prevent the corrosion and thermal stress of alloy tank shells. This work discusses issues and potential solutions related to containment of molten chloride salt, specifically the optimization of the refractory material at the molten salt interface (hot face). The down-selected hot face candidate limits permeation of salt through the material and forms a highly stable secondary surface phase in equilibrium with the molten salt. A mortar is created using the corrosion resistant hot face brick. Brick and mortar composite are subjected to mechanical stress/strain analysis, in order to calculate composite material properties and better inform thermomechanical models. The U.S. Department of Energy Generation 3 (DOE Gen3) program seeks to develop higher efficiency CSP plants that can provide cost-competitive, flexible power in the U.S. electric grid. The proposed Gen3 Liquid Pathway CSP plant closely resembles the configuration of current nitrate salt power towers with two-tank storage (Gen2). The differences between Gen2 and Gen3 include the types of compatible materials used in salt storage tank construction. Stainless steel loses strength at Gen3 temperatures, and although nickel superalloys would be capable of withstanding sustained high temperatures, these materials are prohibitively expensive at scale. Uninsulated tank shells also pose a significant risk as common steels are highly susceptible to chemical attack from molten chloride salt. To address these concerns, refractory-ceramic based containment materials are proposed to line the inside of the hot and cold storage tanks. In doing so, stainless or carbon steel shells may be used in construction depending on the level of insulation provided. The composition of the internal liner requires careful consideration to maximize the efficacy of multiple parameters including corrosion resistance, strength at operating temperature, durability, and cost. This is particularly true for the material at the interface with the salt, known as the "hot face", which is responsible for protecting the insulating layers between the tank shell and the hot face brick layer. The molten salt in this system is superheated over 300 °C above its freeze temperature. Therefore, unlike other industrial processes which use refractory-lined vessels, it is not expected that a freeze plane will develop in the hot face. Therefore, the hot face must be designed to withstand chemical corrosion and inhibit permeation of molten salt into the insulating layers. A down selection was performed to identify a hot face candidate best equipped to maintain thermal, mechanical, and chemical integrity when exposed to molten salt over extended periods of time. Long-duration chemical capability experiments were conducted with the down selected hot face refractory fully immersed in molten chloride salt for up to 3000 hours. The average salt penetration does not exceed 100 microns. When extrapolated to 20 and 30 years of continuous exposure, the expected salt penetration depth is approximately 2.0 mm and 2.9 mm, respectively. A magnesium-rich secondary phases develops at the salt/refractory interface. X-ray diffraction identifies the material as forsterite (Mg2SiO4), which is reported to form synthetically in molten chloride salt solutions. These results suggest the selected hot face will adequately inhibit salt permeation. While there is optimism that the hot face brick will inhibit salt permeation, mortar joints are typically the weakest point of a refractory brick liner. From a thermochemical perspective, differing thermal expansion coefficients may result in the mortar and brick to grow independent of each other, creating gaps through which molten salt can penetrate. To address this issue, NREL has developed an in-house mortar composed of the down selected hot face brick that has been shown to be compatible with the salt. Compressive stress/strain analyses have been performed on the brick/ mortar composites to generate stress/strain curves. Modulus of elasticity and Poisson's ratio of the composite may be calculated from the stress/strain curves, in order to provide more representative data to finite element mechanical models for accurate approximation of stress on the tank shell and the amount of thermal expansion expected within the tank liner.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Finite Element Modeling of Spent Nuclear Fuel in Dry Storage under Seismic Excitation

Spent nuclear fuel (SNF) is currently stored at independent spent fuel storage installations (ISFSIs) at nuclear power plant sites across the US. The US Department of Energy (DOE) Spent Fuel and Waste Science and Technology (SFWST) program is currently working to understand the response of SNF during a seismic event. This investigation is part of a long-term effort by DOE to quantify the external mechanical loads on SNF. The SFWST program has recently completed campaigns evaluating SNF behavior during normal conditions of transport and in 30 cm package drop scenarios; both campaigns included a combination of testing and modeling. Likewise, the investigation into seismic response of SNF will include full-size shake table tests of a vertical storage overpack containing instrumented surrogate fuel assemblies, as well as pre- and post-test finite element modeling. This work focuses on the development of finite element models simulating the planned test configuration. The seismic response is calculated at two scales: at the package level, and at the fuel level. The package level model evaluates the behavior of the storage overpack and its contents in response to the ground motions of a representative earthquake. The motion of the package is input to the fuel level model, which consists of a detailed finite element model of a 17x17 or 16x16 pressurized water reactor (PWR) fuel assembly or of a 10x10 boiling water reactor (BWR) fuel assembly. The stress and strain on individual components such as fuel rods and guide tubes are extracted from this model. This work details the SNF response to various input ground motions, considering representative earthquakes in the Central and Eastern US under various site conditions. Also discussed is the development of a “reduced scope” finite element model of the SNF, which consists of a single fuel rod while retaining the dynamic response of the entire fuel assembly. This reduced scope model addresses the significant computational expense of modeling the SNF under long-duration input ground motions and facilitates simulating additional parameter variations of the model beyond the as-tested configuration. The modeling results provide important insight that will help to inform future testing and modeling efforts by the SFWST program to close the knowledge gap related to external loads on SNF.

Kadooka, Kevin↗

Advanced Processing of Coal and Coal Waste to Produce Graphite for Fast-Charging Lithium-Ion Battery Anode

The University of North Dakota (UND) Energy & Environmental Research Center (EERC), in collaboration with the UND Center for Process Engineering Research (CPER), conducted a project to validate two technologies capable of converting North Dakota lignite and lignite coal waste to high-quality graphite for fast-charging lithium-ion battery (LIB) anode. The project was conducted over about 3 years from April 7, 2022, to July 6, 2025. The two technological paths pursued in this project include path A – direct conversion of coal or coal waste to graphite by the upgraded carbon ores to products (UCOP) process being developed at the EERC and path B – lignite-derived coal tar pitch (CTP) conversion to graphite (CTP2G) process being developed at CPER. The results from this project validate the two technological approaches and are expected to be an integral part of a portfolio of emerging technologies for making high-quality graphite not only from North Dakota lignite, but from all ranks of U.S. domestic coal and coal waste resources. The quality of the graphite produced by these technologies is high enough for various applications, including batteries for the fast-growing electric vehicle industry, energy storage applications, electric arc furnace electrodes for steel production, and graphene production, among others. Although the two technologies can produce high-quality graphite, they are fundamentally different in that the UCOP technology provides a direct path to transform coal to graphite, while the CTP2G technology needs to go through a CTP intermediate and a coking process for the intermediate, which requires a special facility to accomplish. For application in the industry, the UCOP process is designed to be more flexible, with feedstock to include potentially any carbonaceous material such as all coal ranks and biochar, while the CTP2G process is designed to utilize CTP as the starting precursor. The key project accomplishments include the following: • Successful preparation of high-quality synthetic graphite from North Dakota lignite coal/coal wastes and lignite-derived CTP. • Patent application has been filed for the UCOP process and an internal invention disclosure has been filed for the CTP2G process. • The produced graphite performs better than a commercial battery-grade sample in LIB coin cells, especially fast-charging capability, stability, and long-duration cycling. • Coin-type Li-ion half-cells with CTP2G graphite showed excellent performance, with >370 mAh/g capacity, >90% initial coulombic efficiency, and 93%/67% retention at 1C/2C rate, which outperforms commercial graphite in charging speed, stability, and cycling. • Results of fabricated 18650 cells were consistent with the observations in coin cells. • Preliminary techno-economic analysis (TEA) estimates for the UCOP technology indicate a manufacturing cost of about $\$$39/kg based on 50-metric ton/year capacity. • Preliminary TEA estimates for the CTP2G technology indicate a market price of about $\$$7107/ton ($\$$7/kg) based on 22,000-ton/year production capacity.

01 COAL, LIGNITE, AND PEAT↗

Clean Condensing Gas Furnace

Natural gas furnaces are the most common space heating equipment in the U.S. residential and commercial building markets. However, current residential natural gas condensing furnaces generate substantial acidic condensate as well as significant emissions of sulfur oxides (SOx), nitrogen oxides (NOx), carbon monoxide (CO), hydrocarbons (HC), and methane (CH 4 ) contributing to environmental degradation of air, water, and soil. This report describes a novel solution to reduce the environmental impact of natural gas condensing furnaces based on the technology of a monolithic acidic gas reduction (AGR) catalyst for SOx trapping, NOx redox to nitrogen, and oxidation of formic acid, CO, HC, and CH 4 . The AGR technology offers the following benefits: (1) a neutral furnace condensate with a pH of ~7, allowing its safe release into the sewer system thus eliminating a second drainage system; (2) trapping and removing nearly all SOx emissions; (3) NOx emissions nearly at nearly 1-2 ng/J, more than 95% lower than new emissions standards in California; (4) the use of a low-cost heat exchanger as a condensing heat exchanger (HX) since the condensate is not acidic, avoiding the need for expensive stainless steel alloys; and (5) unburnt fuel energy recovery to boost efficiency.The AGR component and AGR-enabled furnace performance were broadly tested to determine their effects on long-term reliability and durability, as well as SOx storage and regeneration activity. The AGR regeneration does not impair the performance in achieving neutral condensate and ultra-low NOx emissions, and the AGR catalyst subjected to regeneration activities continued to function well and achieved slightly better annual fuel utilization efficiency (AFUE). The 400-hour reliability and durability test of the retrofitted condensing furnace with the AGR component shows that the furnace unit still achieves a neutral furnace condensate with a pH of ~7 and enables 0~3 ng/J of NOx emissions. However, the 400-hour operation slightly degraded the AFUE because of soot particle accumulation caused by frequent incomplete combustion owing to inappropriate condensate drainage during testing. Thus, proper condensate drainage is critical for AGR-enabled furnaces. Furthermore, neutron computed tomography was employed to survey the aged AGR component and demonstrate high-resolution 2D and 3D representations for the nondestructive diagnosis of the AGR component. The tomography showed that the AGR component did not deform or suffer broken AGR channels. A new AGR catalyst with low precious metal loading was preliminarily explored to identify a pathway of optimizing AGR material loading and maximizing acidic gas reduction at low cost. The new AGR component can reduce precious metal loading by 38% and still achieve neutral condensate and ultralow NOx emissions. The furnace with the AGR component of low Pt/Rh loading enables a maximum AFUE of 97%, which is meaningfully higher than the original furnace. Long-duration testing for the furnace enabled with the low precious metal loading AGR component will be vital in future research. Although the current work demonstrates a proof of concept for the AGR-enabled furnace, the AGR assembly needs to be optimized and integrated into the design of new OEM furnace products. Furthermore, the AGR technology can be applied not only for residential gas furnaces, but also for commercial rooftop units, gas heat pumps, gas-fired water heaters, combustion boilers, and other systems.

03 NATURAL GAS↗

Estimating the State of Charge in Lithium Primary Batteries: Recent Advances and Critical Insights

Lithium primary batteries (LPBs) remain essential in critical applications such as military, aerospace, medical and emergency devices, and portable electronics. Their superior energy density over lithium-ion batteries offers a significant advantage for long-duration use. Therefore, accurate estimation of the state of charge (SoC) is essential for ensuring the reliable and safe operation of these batteries. While extensive research has been conducted on SoC estimation techniques for lithium-ion secondary batteries, LPBs present unique challenges that complicate accurate SoC estimation. Moreover, research on nondestructive testing techniques for SoC estimation in LPBs is significantly lacking. In this review article, it is aimed to provide a comprehensive overview of recent advancements in SoC estimation for LPBs and generates new insights and directions for future research. Herein, existing methods are discussed and their effectiveness and mechanisms are identified, and areas for further optimization are outlined. More theoretical/experimental efforts to advance SoC detection in LPBs is recommended due to challenges identified with existing techniques.

25 ENERGY STORAGE↗

Long-Term Stability of Ferri-/Ferrocyanide as an Electroactive Component for Redox Flow Battery Applications: On the Origin of Apparent Capacity Fade

We assess the suitability of potassium ferri-/ferrocyanide as an electroactive species for long-term utilization in aqueous organic redox flow batteries. A series of electrochemical and chemical characterization experiments was performed to distinguish between structural decomposition and apparent capacity fade of ferri-/ferrocyanide solutions used in the capacity-limiting side of a flow battery. Our results indicate that, in contrast with previous reports, no structural decomposition of ferri-/ferrocyanide occurs at tested pH values as high as 14 in the dark or in diffuse indoor light. Instead, an apparent capacity fade takes place due to a chemical reduction of ferricyanide to ferrocyanide, via chemical oxygen evolution reaction. We find that this parasitic process can be further exacerbated by carbon electrodes, with apparent capacity fade rates at pH 14 increasing with an increased ratio of carbon electrode surface area to ferricyanide in solution. Based on these results, we report a set of operating conditions that enables the long-duration cycling of alkaline ferri-/ferrocyanide electrolytes and demonstrate how apparent capacity fade rates can be engineered by the initial system setup. If protected from direct exposure to light, the structural stability of ferri-/ferrocyanide anions allows for their practical deployment as electroactive species in long duration energy storage applications.

25 ENERGY STORAGE↗