Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “local control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Outcome and Prognostic Factors in Olfactory Neuroblastoma: A Rare Cancer Network Study

Purpose: To assess the outcome in patients with olfactory neuroblastoma (ONB). Methods and Materials: Seventy-seven patients treated for nonmetastatic ONB between 1971 and 2004 were included. According to Kadish classification, there were 11 patients with Stage A, 29 with Stage B, and 37 with Stage C. T-classification included 9 patients with T1, 26 with T2, 16 with T3, 15 with T4a, and 11 with T4b tumors. Sixty-eight patients presented with N0 (88%) disease. Results: Most of the patients (n = 56, 73%) benefited from surgery (S), and total excision was possible in 44 patients (R0 in 32, R1 in 13, R2 in 11). All but five patients benefited from RT, and chemotherapy was given in 21 (27%). Median follow-up period was 72 months (range, 6-315). The 5-year overall survival (OS), disease-free survival (DFS), locoregional control, and local control were 64%, 57%, 62%, and 70%, respectively. In univariate analyses, favorable factors were Kadish A or B disease, T1-T3 tumors, no nodal involvement, curative surgery, R0/R1 resection, and RT-dose 54 Gy or higher. Multivariate analysis revealed that the best independent factors predicting the outcome were T1-T3, N0, R0/R1 resection, and total RT dose (54 Gy or higher). Conclusion: In this multicenter retrospective study, patients with ONB treated with R0 or R1 surgical resection followed by at least 54-Gy postoperative RT had the best outcome. Novel strategies including concomitant chemotherapy and/or higher dose RT should be prospectively investigated in this rare disease for which local failure remains a problem.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integrated Coordination of Voltage Regulators with Distributed Cooperative Inverter Control in Systems with High Penetration of DGs

Increased penetration of distributed generation (DG) in recent years has a significant impact on operation and control of power systems. One of the main issues with the increased penetration of DGs is the effect of voltage rise. This paper investigates integration of coordinated voltage regulator (VRs) operation with cooperative distributed inverter control to maintain voltages in appropriate limits in distribution systems with high penetration of DGs. The coordinated VR control is used to optimize the settings of multiple nested VRs while the cooperative distributed control optimally dispatches reactive power of the DGs. The integrated approach is compared with the case without coordinated VRs control (uncoordinated local control). Simulation results illustrate the effective performance of the proposed method to achieve unified voltage profile.

coordinated voltage regulator control↗

SU-C-BRB-02: Automatic Planning as a Potential Strategy for Dose Escalation for Pancreas SBRT?

Purpose: Stereotactic body radiation therapy (SBRT) has been suggested to provide high rates of local control for locally advanced pancreatic cancer. However, the close proximity of highly radiosensitive normal tissues usually causes the labor-intensive planning process, and may impede further escalation of the prescription dose. The present study evaluates the potential of an automatic planning system as a dose escalation strategy. Methods: Ten pancreatic cancer patients treated with SBRT were studied retrospectively. SBRT was delivered over 5 consecutive fractions with 6 ∼ 8Gy/fraction. Two plans were generated by Pinnacle Auto-Planning with the original prescription and escalated prescription, respectively. Escalated prescription adds 1 Gy/fraction to the original prescription. Manually-created planning volumes were excluded in the optimization goals in order to assess the planning efficiency and quality simultaneously. Critical organs with closest proximity were used to determine the plan normalization to ensure the OAR sparing. Dosimetric parameters including D100, and conformity index (CI) were assessed. Results: Auto-plans directly generate acceptable plans for 70% of the cases without necessity of further improvement, and two more iterations at most are necessary for the rest of the cases. For the pancreas SBRT plans with the original prescription, autoplans resulted in favorable target coverage and PTV conformity (D100 = 96.3% ± 1.48%; CI = 0.88 ± 0.06). For the plans with the escalated prescriptions, no significant target under-dosage was observed, and PTV conformity remains reasonable (D100 = 93.3% ± 3.8%, and CI = 0.84 ± 0.05). Conclusion: Automatic planning, without substantial human-intervention process, results in reasonable PTV coverage and PTV conformity on the premise of adequate OAR sparing for the pancreas SBRT plans with escalated prescription. The results highlight the potential of autoplanning as a dose escalation strategy for pancreas SBRT treatment planning. Further investigations with a larger number of patients are necessary. The project is partially supported by Philips Medical Systems.

60 APPLIED LIFE SCIENCES↗

All-optical control of charge-trapping defects in rare-earth doped oxides

Abstract Charge-trapping defects in crystalline solids play important roles in applications ranging from microelectronics, optical storage, sensing and quantum technologies. On one hand, depleting trapped charges in the host matrix reduces charge noise and enhances coherence of solid-state quantum emitters. On the other hand, stable charge traps can enable high-density optical storage systems. Here we report all-optical control of charge-trapping defects via optical charge trapping (OCT) spectroscopy of a rare-earth ion doped oxide (Y 2 O 3 ). Charge trapping is realized by low intensity optical excitation in the 200–375 nm range. Charge detrapping or depletion is carried out by optically stimulated luminescence (OSL) under 532 nm stimulation. Using a Pr-doped Y 2 O 3 polycrystalline ceramic host matrix, we observe charging pathways via the inter-band optical absorption of Y 2 O 3 and via the 4f-5d transitions of Pr 3+ . We demonstrate effective control of the density of trapped charges within the Y 2 O 3 matrix at ambient environment. These results point to a viable method for controlling the local charge environment in rare-earth doped crystals via all-optical means, and pave the way for further development of efficient optical storage technologies with ultrahigh storage capacity, as well as for the localized control of quantum coherence in rare-earth doped solids.

França, Leonardo V. S. [Pritzker School of Molecul↗

Operators manual for microdensitometer control program densitometer model PDS-1010G (modified). Program trace version 3B (section 3)

The PDS-1010G microdensitometer is run under the control of a PDP-11 program called TRACE. This program gives the operator vary flexible control over the machine functions. Most commands are passed to the computer through either the Tektronix 4010 terminal or the teletype, as selected by the position of the LOCAL/LINE rocker switch above the 4010 keyboard. (LINE places the 4010 in control; LOCAL transfers control to the teletype. In general, the teletype is used when the operator desires a permanent record of the operator-computer dialogue.) A small number of control functions are requested by setting switches on the computer front panel.

Title, A. M.↗

Automated Positioner For A Specimen In A Vacuum Chamber

Custom-build apparatus positions specimen in vacuum system in three translational and one rotational degree of freedom. Operates under manual control, local microprocessor control, or remote computer control via general-purpose interface bus (GPIB), specific control option being selectable by technician. Used to position and orient specimen for secondary-ion mass spectroscopy (SIMS). Apparatus made from relatively inexpensive parts.

Bailey, Sheila G.↗

Performance Evaluation of Individual Aircraft Based Advisory Concept for Surface Management

Surface operations at airports in the US are based on tactical operations, where departure aircraft primarily queue up and wait at the departure runways. NASA's Spot And Runway Departure Advisor (SARDA) tool was developed to address these inefficiencies through Air Traffic Control Tower advisories. The SARDA system is being updated to include collaborative gate hold, either tactically or strategically. This paper presents the results of the human-in-the-loop evaluation of the tactical gate hold version of SARDA in a 360 degree simulated tower setting. The simulations were conducted for the east side of the Dallas/Fort Worth airport. The new system provides gate hold, ground controller and local controller advisories based on a single scheduler. Simulations were conducted with SARDA on and off, the off case reflecting current day operations with no gate hold. Scenarios based on medium (1.2x current levels) and heavy (1.5x current levels) traffic were explored. Data collected from the simulation was analyzed for runway usage, delay for departures and arrivals, and fuel consumption. Further, Traffic Management Initiatives were introduced for a subset of the aircraft. Results indicated that runway usage did not change with the use of SARDA, i.e., there was no loss in runway throughput as compared to baseline. Taxiing delay was significantly reduced with the use of advisory by 45% in medium scenarios and 60% in heavy. Arrival delay was unaffected by the use of advisory. Total fuel consumption was also reduced by 23% in medium traffic and 33% in heavy. TMI compliance appeared unaffected by the advisory

departure metering↗

Performance Evaluation of SARDA: An Individual Aircraft-Based Advisory Concept for Surface Management

Surface operations at airports in the US are based on tactical operations, where departure aircraft primarily queue up and wait at the departure runways. NASAs Spot And Runway Departure Advisor (SARDA) tool was developed to address these inefficiencies through Air Traffic Control Tower advisories. The SARDA system is being updated to include collaborative gate hold, either tactically or strategically. This paper presents the results of the human-in-the-loop evaluation of the tactical gate hold version of SARDA in a 360 degree simulated tower setting. The simulations were conducted for the east side of the Dallas-Fort Worth airport. The new system provides gate hold, ground controller and local controller advisories based on a single scheduler. Simulations were conducted with SARDA on and off, the off case reflecting current day operations with no gate hold. Scenarios based on medium (1.2x current levels) and heavy (1.5x current levels) traffic were explored. Data collected from the simulation was analyzed for runway usage, delay for departures and arrivals, and fuel consumption. Further, Traffic Management Initiatives were introduced for a subset of the aircraft. Results indicated that runway usage did not change with the use of SARDA, i.e., there was no loss in runway throughput as compared to baseline. Taxiing delay was significantly reduced with the use of advisory by 45 in medium scenarios and 60 in heavy. Arrival delay was unaffected by the use of advisory. Total fuel consumption was also reduced by 23 in medium traffic and 33 in heavy. TMI compliance appeared unaffected by the advisory.

Yoon Jung↗

Biased Electrodes for SOL Control in NSTX

Small electrodes were installed in the outer-midplane edge of NSTX to attempt to control the local width of the scrape-off layer (SOL) by creating an outward E(pol)xB flow. When the applied voltage between electrodes was 90 V, the density between these electrodes increased by a factor of 3-10 over a radial width of similar to 4 cm. Thus a local control of the SOL plasma density was obtained. (C) 2009 Elsevier B.V. All rights reserved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Analysis of Distribution Network Voltage Regulation Using Smart Inverters: Preprint

Smart inverters (SI) have huge potential in providing grid services which has not been fully realized yet. One of these grid services, distribution network voltage regulation by SI, can improve the network voltage by regulating the SI reactive and active power output. Voltage regulation by SI is much faster compared to traditional voltage regulating devices, e.g. tap changing transformer, capacitor banks. However, there is gap in available published literature on the characteristics of SIs when the SI is controlled by local controller or external control signal. This paper presents the experimental study to characterize SI reactive power regulation response to two different control methods: autonomous control method and remote dispatch method. It was found that IS reactive power regulation response could be significantly different in terms of delay, and ramp rate for these two methods. Finally, Power-Hardware-in-The-Loop (PHIL) tests were conducted to evaluate the performance of these two methods. The PHIL tests results show that SI response characteristics for autonomous control method and remote dispatch method need to be considered during planning for distribution network voltage regulation using SI.

autonomous control↗

High level continuity for coordinate generation with precise controls

Coordinate generation techniques with precise local controls have been derived and analyzed for continuity requirements up to both the first and second derivatives, and have been projected to higher level continuity requirements from the established pattern. The desired local control precision was obtained when a family of coordinate surfaces could be uniformly distributed without a consequent creation of flat spots on the coordinate curves transverse to the family. Relative to the uniform distribution, the family could be redistributed from an a priori distribution function or from a solution adaptive approach, both without distortion from the underlying transformation which may be independently chosen to fit a nontrivial geometry and topology.

Eiseman, P. R.↗

Signal-Anticipation in Local Voltage Control in Distribution Systems

We consider the signal-anticipating behavior in local Volt/Var control for distribution systems. Such a behavior makes interaction among the nodes a game. We characterize Nash equilibrium of the game as the optimum of a global optimization problem and establish its asymptotic global stability. We also show that the signal-anticipating voltage control has less restrictive convergence condition than the signal-taking control. We then introduce the notion of price of signal-anticipation (PoSA) to characterize the impact of signal-anticipating control, and use the gap in cost between network equilibrium in the signal-taking control and Nash equilibrium in the signal-anticipating control as the metric for PoSA. We characterize how the PoSA scales with the size, topology, and heterogeneity of the distribution network for a few network settings. Our results show that the PoSA is upper bounded by a constant and the average PoSA per node will go to zero as the size of the network increases. This is desirable as it means that the PoSA will not be arbitrarily large, no matter what the size of the network is, and no mechanism is needed to mitigate the signal-anticipating behavior. We further carry out numerical experiments with a real-world distribution circuit to complement the theoretical analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Repeat Brachytherapy for Patients With Residual or Recurrent Tumors of Oral Cavity

Purpose: To analyze data from patients receiving repeat brachytherapy (re-BT) for the treatment of residual or recurrent tumor in the oral cavity. Methods and Materials: Between January 2003 and December 2007, 62 patients who had undergone definitive BT as an initial treatment of oral cancer subsequently underwent re-BT for the treatment of residual or recurrent tumors at the diagnostic radiology and oncology department (Tokyo Medical and Dental University Hospital). Re-BT was performed 0.9-73 months (median, 5.7) after the initial BT. Au-198 grains were used as the re-BT source in all 62 patients, and an area of 0.8-6.3 cm{sup 2} (median, 3.1) was permanently irradiated with 60-110 Gy (median, 83) according to the system of Paterson-Parker. Results: The 2-year local control and overall survival rate was 53% and 66%, respectively, and local control significantly affected overall survival. Both local control and overall survival were affected by the initial tumor characteristics and the macroscopic appearance of the residual or recurrent tumor. Grade 3 or 4 complications were seen in 5 patients. The incidence of mandibular and mucosal complications was significantly related to a biologic effective dose of {alpha}/{beta} of 3 Gy to the surface of the gingiva and mucosa, respectively. Conclusion: Re-BT using Au-198 grains for the treatment of residual or recurrent tumor after definitive BT in the oral cavity is effective and well tolerated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Response for Stereotactic Body Radiotherapy in Early-Stage Non-Small-Cell Lung Cancer

Purpose: To compare the efficacy of three lung stereotactic body radiotherapy (SBRT) regimens in a large institutional cohort. Methods: Between 2004 and 2009, 130 patients underwent definitive lung cancer SBRT to a single lesion at the Mallinckrodt Institute of Radiology. We delivered 18 Gy Multiplication-Sign 3 fractions for peripheral tumors (n = 111) and either 9 Gy Multiplication-Sign 5 fractions (n = 8) or 10 Gy Multiplication-Sign 5 fractions (n = 11) for tumors that were central or near critical structures. Univariate and multivariate analysis of prognostic factors was performed using the Cox proportional hazard model. Results: Median follow-up was 11, 16, and 13 months for the 9 Gy Multiplication-Sign 5, 10 Gy Multiplication-Sign 5, and 18 Gy Multiplication-Sign 3 groups, respectively. Local control statistics for Years 1 and 2 were, respectively, 75% and 50% for 9 Gy Multiplication-Sign 5, 100% and 100% for 10 Gy Multiplication-Sign 5, and 99% and 91% for 18 Gy Multiplication-Sign 3. Median overall survival was 14 months, not reached, and 34 months for the 9 Gy Multiplication-Sign 5, 10 Gy Multiplication-Sign 5, and 18 Gy Multiplication-Sign 3 treatments, respectively. No difference in local control or overall survival was found between the 10 Gy Multiplication-Sign 5 and 18 Gy Multiplication-Sign 3 groups on log-rank test, but both groups had improved local control and overall survival compared with 9 Gy Multiplication-Sign 5. Treatment with 9 Gy Multiplication-Sign 5 was the only independent prognostic factor for reduced local control on multivariate analysis, and increasing age, increasing tumor volume, and poor performance status predicted independently for reduced overall survival. Conclusion: Treatment regimens of 10 Gy Multiplication-Sign 5 and 18 Gy Multiplication-Sign 3 seem to be efficacious for lung cancer SBRT and provide superior local control and overall survival compared with 9 Gy Multiplication-Sign 5.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Central Control of Local Oscillator Frequencies

Central unit automatically controls frequencies of group of independent crystal-controlled low-power oscillators. Unit checks its own frequency against accurate frequency reference, such as station WWV and corrects its own timing circuit as necessary.

Smith, S. F.↗

Overexpression of Intrinsic Hypoxia Markers HIF1{alpha} and CA-IX Predict for Local Recurrence in Stage T1-T2 Glottic Laryngeal Carcinoma Treated With Radiotherapy

Purpose: To examine the prognostic value of three endogenous hypoxia markers (hypoxia inducible factor 1 {alpha} subunit [HIF1{alpha}], carbonic anhydrase IX [CA-IX], and glucose transporter type 1 [GLUT-1]) on the clinical outcome in patients with early-stage glottic carcinoma primarily treated with radiotherapy (RT) and to determine the predictive hypoxic profile to choose the optimal treatment of early-stage laryngeal carcinoma. Methods and Materials: Immunohistochemistry for HIF1{alpha}, CA-IX, and GLUT-1 was performed on formalin-fixed, paraffin-embedded, pretreatment tissue samples of 91 glottic squamous cell carcinoma specimens. The patient group consisted only of those with early-stage (T1-T2) glottic carcinoma, and all patients were treated with RT only. Relative tumor staining was scored on the tissue samples. Receiver operating curve analysis was performed to determine the optimal cutoff value for each tumor marker. Cox regression analyses for the variables HIF1{alpha}, CA-IX, GLUT-1, gender, age, hemoglobin level, T category, N category, tobacco use, and alcohol use were performed with local control and overall survival as endpoints. Results: HIF1{alpha} overexpression in early-stage glottic carcinoma correlated significantly with worse local control (hazard ratio [HR], 3.05; p = 0.021) and overall survival (HR, 2.92; p = 0.016). CA-IX overexpression correlated significantly with worse local control (HR, 2.93; p = 0.020). GLUT-1 overexpression did not show any correlation with the clinical outcome parameters. Tumors with a nonhypoxic profile (defined as low HIF1{alpha} and low CA-IX expression) had significantly better local control (HR, 6.32; p 0.013). Conclusion: The results of our study have shown that early-stage glottic laryngeal carcinomas with low HIF1{alpha} and CA-IX expression are highly curable with RT. For this group, RT is a good treatment option. For tumors with HIF1{alpha} or CA-IX overexpression, hypoxic modification before RT or primary surgical treatment should be considered.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Body Radiation Therapy for Oligometastases to the Lung: A Phase 2 Study

Purpose: To assess, in a phase 2 study, the efficacy and toxicity of stereotactic body radiation therapy for oligometastases to the lung in inoperable patients. Methods and Materials: Patients with lung metastases were included in this study if (1) the primary tumor was controlled; (2) patients were ineligible for or refused surgery and chemotherapy; and (3) patients had 5 or fewer metastatic lesions in no more than 2 organs. Large peripheral tumors were treated with a dose of 60 Gy (3 fractions), small peripheral tumors with 30 Gy (1 fraction), central tumors received 60 Gy (5 fractions), and mediastinal tumors or tumors close to the esophagus received 56 Gy (7 fractions). Results: Thirty patients with 57 metastatic lung tumors from various primary cancers were analyzed. The median follow-up was 36 months (range, 4-60 months). At 2 years, local control for the 11 central tumors was 100%, for the 23 peripheral tumors treated to 60 Gy it was 91%, and for the 23 tumors treated in a single 30-Gy fraction it was 74% (P=.13). This resulted in an overall local control rate at 1 year of 79%, with a 2-sided 80% confidence interval of 67% to 87%. Because the hypothesized value of 70% lies within the confidence interval, we cannot reject the hypothesis that the true local control rate at 1 year is ≤70%, and therefore we did not achieve the goal of the study: an actuarial local control of the treated lung lesions at 1 year of 90%. The 4-year overall survival rate was 38%. Grade 3 acute toxicity occurred in 5 patients. Three patients complained of chronic grade 3 toxicity, including pain, fatigue, and pneumonitis, and 3 patients had rib fractures. Conclusions: The local control was promising, and the 4-year overall survival rate was 38%. The treatment was well tolerated, even for central lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mucosal Malignant Melanoma of the Head and Neck Treated by Carbon Ion Radiotherapy

Purpose: To evaluate the efficacy of carbon ion radiotherapy for mucosal malignant melanoma of the head and neck. Methods and Materials: Between 1994 and 2004, 72 patients with mucosal malignant melanoma of the head and neck were treated with carbon ion beams in three prospective studies. Total dose ranged from 52.8 GyE to 64 GyE given in 16 fixed fractions over 4 weeks. Clinical parameters including gender, age, Karnofsky index, tumor site, tumor volume, tumor status, total dose, fraction size, and treatment time were evaluated in relation to local control and overall survival. Results: The median follow-up period was 49.2 months (range, 16.8-108.5 months). Treatment toxicity was within acceptable limits, and no patients showed Grade 3 or higher toxicity in the late phase. The 5-year local control rate was 84.1%. In relation to local control, there were no significant differences in any parameters evaluated. The 5-year overall and cause-specific survival rates were 27.0% and 39.6%, respectively. For overall survival, however, tumor volume ({>=}100 mL) was found to be the most significant prognostic parameter. Of the patients who developed distant metastasis, 85% were free from local recurrence. Conclusion: Carbon ion radiotherapy is a safe and effective treatment for mucosal malignant melanoma of the head and neck in terms of high local control and acceptable toxicities. Overall survival rate was better than in those treated with conventional radiotherapy and was comparable to that with surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗