Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load shift”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Thermal and mechanical performance of gypsum composites containing fly ash cenosphere encapsulated phase change materials

Utilizing phase change materials (PCMs) within construction materials improves the thermal energy storage capabilities in the built environment. Notably, integrating PCMs into drywalls presents a promising avenue to reduce building energy use. However, incorporating PCMs into drywalls poses challenges, particularly reduced mechanical properties and workability limitations as it can adversely affect the hardening and cohesiveness of gypsum composites. To address these challenges, this study explores a novel strategy to incorporate PCMs into gypsum composites through fly ash cenosphere-encapsulated PCM, namely CenoPCM, aiming to enhance the mechanical properties and thermal conductivity over existing commercial counterparts. An experimental program was conducted to study the impact of the inclusion of CenoPCM on the mechanical and thermal performance of gypsum composites, and the results were compared to those of commercially available polymerencapsulated PCM benchmark (Micronal). The findings highlighted that PCM-charged samples exhibited up to 95.90 J/g (CenoPCM) of latent heat with 70 % CenoPCM loading. The results of mechanical tests also showed that CenoPCM outperformed its polymer-encapsulated counterpart, achieving 55 % higher mechanical strength on average. Here, this improvement is attributed to the rigid shell of fly ash cenosphere (FAC) serving as a PCM carrier, providing a skeleton-like structure to gypsum composites for higher load-bearing capacity. Additionally, hotbox tests demonstrated that the CenoPCM-charged wall panels yielded a 20 % higher thermal conductivity and a 22 % increased time lag compared to Micronal PCM-charged panels, indicating its potential to shift the peak load in buildings.

Ceno PCM↗

Techno-Economic Analysis of Dynamic Building Envelopes Comprising Phase Change Materials and Switchable Insulations: Preprint

Integrating phase change materials (PCMs) in building envelopes is a recognized technique to reduce the space heating/cooling loads and provide load shedding and shifting capacity. However, PCM benefits have been found to reduce dramatically with increase in the insulation requirements. Dynamic building envelopes that can alter their thermal resistance based on the indoor and outdoor conditions can effectively harness free ambient heating/cooling, thereby greatly enhancing the benefits of the PCM-integrated envelope in managing thermal loads. In this study, we examine various combinations of PCMs and switchable insulations and compare their combined impact on heat flow through the building envelope. Using numerical analysis, we investigate the PCM- and switchable insulation-integrated building walls, calculate the potential energy saving benefits compared to the conventional static walls, and finally perform technoeconomic analysis to estimate the acceptable cost of the technology under various payback period scenarios.

dynamic building envelopes↗

Techno-Economic Analysis of Dynamic Building Envelopes Comprising Phase Change Materials and Switchable Insulations

Integrating phase change materials (PCMs) in building envelopes is a recognized technique to reduce the space heating/cooling loads and provide load shedding and shifting capacity. However, PCM benefits have been found to reduce dramatically with increase in the insulation requirements. Dynamic building envelopes that can alter their thermal resistance based on the indoor and outdoor conditions can effectively harness free ambient heating/cooling, thereby greatly enhancing the benefits of the PCM-integrated envelope in managing thermal loads. In this study, we examine various combinations of PCMs and switchable insulations and compare their combined impact on heat flow through the building envelope. Using numerical analysis, we investigate the PCM- and switchable insulation-integrated building walls, calculate the potential energy saving benefits compared to the conventional static walls, and finally perform techno-economic analysis to estimate the acceptable cost of the technology under various payback period scenarios.

dynamic building envelopes↗

Defining and applying an electricity demand flexibility benchmarking metrics framework for grid-interactive efficient commercial buildings

Building demand flexibility (DF) research has recently gained attention. To unlock building DF as a predictable grid resource, we must establish a quantitative understanding of the resource size, performance variability, and predictability based on large empirical datasets. Researchers have proposed various sets of theoretical metrics to measure this performance. Some metrics have been applied to simulation results, but most fall short of exploring the complexities in real building applications. There are practical metrics used in individual demand response field studies but they alone cannot fulfil the job of DF benchmarking across a diverse group of buildings. The electrical grid's geographically diverse and changing nature presents challenges to comparing building DF performance measured under different conditions (i.e., benchmarking DF). To address this challenge, a novel DF benchmarking framework focused on load shedding and shifting is presented; the foundation is a set of simple, proven single-event metrics with attributes describing event conditions. These enable benchmarking and visualization in different dimensions for identifying trends that represent how these attributes influence DF. To test its feasibility and scalability, the DF framework was applied to two case studies of 11 office buildings and 121 big-box retail buildings with demand response participation data. Furthermore, these examples provided a pathway for using both building level benchmarking and aggregation to extract insights into building DF about magnitude, consistency, and influential factors. Potential applications of the framework and real-world values have been identified for grid and building stakeholders.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Decarbonizing all-electric communities via carbon-responsive control of behind-the-meter resources

The progression of electrification in the building and transportation sectors brings new opportunities for energy decarbonization. With higher dependence on the grid power supply, the variation of the grid carbon emission intensity can be utilized to reduce the carbon emissions from the two sectors. Existing coordinated control methods for buildings with distributed energy resources (DERs) either consider electricity price or renewable energy generation as the input signal, or adopt optimization in the decision-making, which is difficult to implement in the real-world environment. This paper aims to propose and validate an easy-to-deploy rule-based carbon responsive control framework that facilitates coordination between all-electric buildings and electric vehicles (EVs). The signals of the grid carbon emission intensity and the local photovoltaics (PV) generation are used for shifting the controllable loads. Extensive simulations were conducted using a model of an all-electric mixed-use community in a cold climate to validate the control performance with metrics such as emissions, energy consumption, peak demand, and EV end-of-day state-of-charge (SOC). Our study identifies that 4.5% to 27.1% of annual emission reduction can be achieved with limited impact on energy costs, peak demand, and thermal comfort. Additionally, up to 32.7% of EV emission reduction can be obtained if the EV owners reduce the target SOC by less than 21.2%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing building energy performance by effectively using phase change material and dynamic insulation in walls

Deploying phase change materials (PCMs) in building envelopes can be efficacious in reducing space heating/cooling loads and providing load shedding and shifting capacity. However, the full potential of PCM-integrated envelopes can only be harnessed if the PCM undergoes phase change using free ambient heating/cooling, and the stored energy is effectively transferred between the exterior and the interior environments. Traditional thermal insulation (with a fixed thermal resistance) limits PCM utilization, which restrains the energy saving potential of a PCM-integrated envelope to a small percentage. Proposed dynamic insulation material and system (DIMS) provides the option of varying its thermal resistance based on the indoor and outdoor conditions. Although it has been established that employing PCM as well as DIMS in building envelopes separately improves buildings’ energy performance, no prior studies that analyzed the combined influence of both technologies were identified. In this study, we examine a novel wall design, comprising a layer of PCM between two layers of DIMS. We note that the PCM-DIMS-integrated wall provides significantly higher energy saving potential than the DIMS-only integrated wall or the PCM-only integrated wall in all the climates and wall orientations analyzed in this study. Depending on the climate, the PCM-DIMS-integrated wall could provide 15–72% reduction in annual heat gain and 7–38% reduction in annual heat loss. The analysis presented in this study supports the need to develop scalable dynamic insulations combined with thermal energy storage systems for buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multiscale Effects Masked the Impact of the COVID-19 Pandemic on Electricity Demand in the United States

Shelter-in-place orders and business closures related to COVID-19 changed the hourly profile of electricity demand and created an unprecedented source of uncertainty for the grid. The potential for continued shifts in electricity profiles has implications for electricity sector investment and operating decisions that maintain reserve margins and provide grid reliability. This study reveals that understanding this uncertainty requires an understanding of the underlying drivers at the customer-class scale. This paper utilizes three datasets to compare the impacts of COVID-19 on electricity consumption across a range of spatiotemporal and customer scales. At the utility/customer-class scale, COVID-19-induced shutdowns in the spring of 2020 shifted weekday residential load profiles to resemble weekend profiles from previous years. Total commercial loads declined, but the commercial diurnal load profile was unchanged. With only total loads available at the balancing authority scale, the apparent impact of COVID-19 was smaller during the summer due in part to phased re-opening and spatial variability in re-opening, but there were still clear variations once total loads were broken down zonally. Monthly data at the state scale showed an increase in state-level residential electricity sales, a decrease in commercial sales, and a small net decrease in total sales in most states from April-August 2020. Analyses that focus on total load or a single scale may miss important changes that become apparent when the load is broken down regionally or by customer class.

COVID-19, electricity demand, multiscale, Commonwe↗

Wood template-supported phase change material composites for durable and form-stable thermal energy storage in buildings

Here, to reduce and shift peak energy loads in buildings, phase change materials (PCMs) with high transition enthalpies and transition temperatures near human thermal comfort are desirable for thermal energy storage (TES). Traditional solid/liquid PCMs suffer from leakage during thermal cycling, requiring encapsulation that lowers heat storage capacity. Wood templates (WTs), with porous and hierarchical structures, provide natural encapsulation scaffolds for PCM containment. Polyethylene glycol (PEG) is a compatible PCM with WTs, but when infiltrated alone, ~30 wt% of PEG binds to wood with no detectable phase change, limiting TES efficiency. To address this, we developed a method to (1) improve the form stability of balsa and pine-based composites (BWT + PCMs and PWT + PCMs) and (2) reduce inactive PCM within the composites to ~10 wt%. BWT + PCMs exhibit transition properties upwards of 114.2 J/g at 25.4 degrees C, with no degradation after 1000 thermal cycles, and similar stiffness compared to raw balsa. Meanwhile, PWT + PCMs exhibit 25 % higher storage efficiency with the addition of poly(ethylene glycol) diacrylate compared to solely PEG-infiltrated PWT. PWT + PCM retains 84 % of raw pine's mechanical stiffness, sufficient for light-duty construction. Our shape-stabilized WT + PCM composites enrich the functionality of wood materials as both ideal TES material candidates and light-duty building construction applications.

25 ENERGY STORAGE↗

Nondimensional convection numbers modeling thermally stratified storage tanks: Richardson's number and hot-water tanks

Thermally stratified storage tank studies have spanned over 50 years to increase the thermal storage efficiency and accurate prediction of the outlet temperature particularly for solar applications. The studies have reviewed and modeled the jet and plume flow phenomena inside the tank due to the inlet mixing and stratification level. Kelvin–Helmholtz and Rayleigh–Taylor instabilities are the major drivers of the mixing in these tanks. Momentum jets deflecting off walls at the bottom of the tank also create significant mixing. Reviewing Richardson models shows that the categorization was based on the range of Reynolds numbers at the inlet. Unfortunately, the use of superficial velocity in calculating the Richardson number results in critical values in the literature ranging from below 0.25 to 100. The most used length scale associated with these flows is an inertial scale based on the tank height or diameter although the mixing can occur at a relatively smaller scale. The various inlet devices and a large span of flow rates experienced in thermally stratified storage tanks requisite the use of the Reynolds number in combination with a convection number for accurate one dimensional models that predict performance over the long-term. The evaluation of peak shifting of electric loads leveraging renewable sources for applications, including residential hot-water tanks, commercial water tanks, and large-scale chilled water storage tanks, require these models. Finally, this paper is focused on establishing the significance of the convection numbers in conjunction with the Reynolds number for modeling the thermal stratification in storage tanks.

14 SOLAR ENERGY↗

Interligand Coupling Drives Fast Triplet Energy Transfer Routes in PbS/Tetracene Quantum Dot Hybrids

The binding of photoactive organic ligands to inorganic quantum dots (QDs) creates a versatile hybrid architecture that allows access to photophysical processes such as efficient triplet exciton generation with near-infrared radiation. Here we report the subnanosecond generation of a hybrid triplet state with mixed ligand-QD character by replacing native oleate ligands on small PbS QDs with 5,12-tetracenepropiolic acid, a bifunctional ligand with two carboxylic acids that tends to lie face-on with the QD surface at low loadings. The face-on geometry engenders a regime of strong electronic coupling that is evident in steady-state absorption and hastens triplet energy flow by several orders of magnitude compared with more typical tetracene-based ligands exhibiting weak coupling. We further determined via Fourier transform infrared (FTIR) and supported by density functional theory (DFT)-based geometry optimizations that high ligand loading causes a shift in QD-ligand mutual disposition toward an edge-on geometry that instigates the formation of intermolecular excited states characterized by triplet excimer-like features in photoluminescence and transient absorption. Our results demonstrate the ability to control strongly coupled ligand-QD systems toward ultrafast generation of photophysically relevant species such as triplets that are valuable for photon upconversion and catalysis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical Modeling and Parametric Study of a Dual Purpose Underground Thermal Battery

Buildings’ thermal energy systems for providing space heating/cooling consume a considerable amount of electricity nationwide. Integrating thermal energy storage with buildings’ thermal systems has the potential to shave the peak electric demand and to overcome the mismatch between the intermittent renewable power and the fluctuating daily demand for electricity. A novel dual-purpose underground thermal battery (DPUTB) has been developed to provide diurnal thermal energy storage in conjunction with a dual-source heat pump (DSHP)system. A two-dimensional numerical model is developed to simulate the transient performance of the DPUTB. This model has similar accuracy as a detailed three-dimensional model developed with commercial heat transfer and fluid dynamics simulation program but with 1000 times faster computational speed. A parametric study is performed to identify a design of the DPUTB that can provide 14 kWh thermal storage capacity for each charging and discharging cycle. A system simulation has been developed to assess the performance of the designed DPUTB when it is integrated with a DSHP for conditioning a typical residential building in summer and winter. Simulation results indicate that the DPUTB can meet all the design requirements in both summer and winter with the simple rule-based control strategy and the overall integrated DPUTB and DSHP system can shift the electric load for meeting the thermal demand from the peak hours to off-peak hours during a day, which would result in considerable energy cost savings if a Time of Use electricity tariff is applicable.

25 ENERGY STORAGE↗

BE-SATED: Building Energy Storage At The Edges of Demand

Otherlab is leading research efforts to validate and deploy battery-integrated appliances in real-world settings. The primary goal is to demonstrate the ability of these appliances to shift residential energy loads and reduce peak demand. Additionally, the project aims to secure safety certifications for battery-integrated appliances and establish a key industrial partnership with an appliance manufacturer for broader market adoption.

25 ENERGY STORAGE↗

Integrating a Microgrid Controller with a Local OpenADR Server

When military microgrids isolate themselves from the main electrical grid, they must locally balance electricity supply and demand. Since local generation may be limited, the current strategy is to shed all but the most critical loads by tripping smart circuit breakers, which must then be reset manually (e.g., ESTCP project EW-201350). This strategy is typically applied at the building level, meaning that entire buildings housing mission critical activities must be excluded from any load management, while those considered non-critical may lose service entirely. The remotely controlled switchgear needed to manage load in this way is very expensive ($\$30,000$-$\$50,000$ per building). While effective at shedding load, this strategy disrupts installation operation and risks damaging equipment during both disconnection and re-energization. With the goals of lowering costs, protecting equipment, and enhancing the agility of DoD microgrids, this report demonstrates the use of cybersecure automated demand response (ADR) technology to manage microgrid loads during grid-independent (a.k.a. "islanded") operation. This automated approach achieves load shedding and shifting through communication signals sent to equipment controllers rather than by cutting off the flow of electricity within the microgrid itself. Because it operates only on the base network, with no connection to external entities, this strategy avoids the main cybersecurity concern raised by past applications of ADR on military bases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impacts of Hurricane Disturbance on Water Quality across the Aquatic Continuum of a Blackwater River to Estuary Complex

Hurricanes cause landscape-scale disturbances that affect biogeochemical cycling and water quality in coastal ecosystems. During Hurricane Irma’s passage through northern Florida, water movements driven by wind velocities up to 105 km h-1 caused a salinity peak in an estuary/blackwater river complex. Water quality was monitored across the 15 km site to detect the magnitude and duration of disturbance. Saline water intruded 15 km inland into a freshwater portion of the river that peaked at a salinity of 2 psu. Due to the volume of precipitation from the hurricane, significant runoff of freshwater and dissolved organic matter (DOM) caused a decrease in salinity, dissolved oxygen (DO), and Chlorophyll-a concentrations while increasing turbidity and fluorescent dissolved organic matter (fDOM). The disturbance caused rapid changes observed by in-situ water quality monitors over a 3-week period, but some effects persisted for longer periods as shown by 3-month weekly water sampling. This disturbance caused shifts in DOM loading, altered salinity dynamics, and reshaped landscapes due to wind and wave surge both in upland marsh and downstream estuary. Hurricane disturbance temporarily and abruptly alters the aquatic continuum, and observations of system response can help us understand the mechanisms associated with ecosystem resilience and recovery.

54 ENVIRONMENTAL SCIENCES↗

Provision of Grid Services by PV Plants with Integrated Battery Energy Storage System: Preprint

Battery energy storage systems (BESS), due to their tremendous range of uses and configurations, may assist PV integration in any number of ways by increasing power system flexibility. In this paper we describe results of a research project conducted by NREL and First Solar for developing controls and demonstrating many use cases for PV-BESS systems including (1) matching generation to loads through time shifting, reducing PV curtailment,; (2) promoting higher levels of PV penetrations by balancing the grid through ancillary services; (3) use of PV-BESS systems to provide wide-area stability services in the form of oscillations damping controls; and (r) use of gird forming BESS for enabling black start and islanded applications for PV-BESS systems. In the paper we will also describe the unique multi-MW test and validation platform developed at NREL for conducting research on fielded utility-scale PV-BESS systems. The platform consists of First Solar 0.43 MW PV power plant, NREL’s 1MW/1MW BESS, 2MW PV power supplies and 7MVA power electronic grid simulator interfaced with industrial plant controllers and power-hardware-in-the-loop (PHIL) capability.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Comfort units and systems, methods, and devices for use thereof

Despite otherwise uncomfortable conditions in a surrounding environment, a customizable microenvironment can be created around a user to maintain a comfortable temperature and/or humidity level using a comfort unit. For example, the environment may be an office building where conditions are out of the comfortable range to save on energy or for other reasons, a factory/shop environment that is poorly conditioned, or an outdoor location with little to no conditioning. A sensing unit can monitor biometric and environmental data and can determine a comfort level of the user. The comfort unit can then dynamically respond to the determined comfort level and adjust the microenvironment to improve the user's comfort level. The comfort unit can follow the user as the user moves within the macro-environment, or can otherwise move within the macro-environment to achieve certain functions, such as recharging or spatial shifting of thermal load within the overall macro-environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal Storage Performance of a Dual-Purpose Underground Thermal Battery for Shaping the Electric Demand of Buildings

A dual-purpose underground thermal battery (DPUTB) integrates a ground heat exchanger with underground thermal energy storage. It can be installed in shallow boreholes (less than 6 m deep) and thus is less expensive than the conventional ground heat exchangers. The thermal energy storage can be used to shave or shift the electric load for meeting the thermal demands of a building. The charging and discharging performance of a lab-scale DPUTB were tested. The test results show that the DPUTB can be fully charged within 4 h and can provide 34 W cooling continuously for 2.5 h with a supply water temperature below 14°C. A small amount of phase-change material significantly increased the thermal storage capacity.

Wang, Lingshi↗

Feasibility Study of Real-Time Carbon Emission Responsive Electric Vehicle Charging Control in Buildings: Preprint

With the progressing electrification of the transportation sector, the source of carbon emissions is gradually shifting from fossil fuel to grid electricity because of electric vehicles (EVs). The carbon intensity of the grid can fluctuate significantly within hours due to the time-varying power generation mix. Therefore, shifting EV charging loads to cleaner hours in response to the carbon intensity signals can reduce carbon emissions. Existing EV charging control methods typically consider the electricity price or the available generation by distributed energy resources (e.g., photovoltaics) to inform decision-making. Such methods tend to reduce energy costs but may neglect the environmental impact of EV charging activities. We propose and compare four carbon emission responsive EV charging controllers with various control rules. The proposed controllers are evaluated based on simulation experiments using metrics such as carbon emission reduction potential, state of charge (SOC) at departure, and peak demand. We found that the need of EV owners to have full batteries at departure could lead to an emission increase when the curtailed EV charge was compensated before departure. Further, up to 12.7% of carbon emission reduction can be achieved if the EV owners reduce the target SOC at departure by less than 15%.

carbon emission↗