High-Frequency ac Power-Distribution System

Loads managed automatically under cycle-by-cycle control. 440-V rms, 20-kHz ac power system developed. System flexible, versatile, and "transparent" to user equipment, while maintaining high efficiency and low weight. Electrical source, from dc to 2,200-Hz ac converted to 440-V rms, 20-kHz, single-phase ac. Power distributed through low-inductance cables. Output power either dc or variable ac. Energy transferred per cycle reduced by factor of 50. Number of parts reduced by factor of about 5 and power loss reduced by two-thirds. Factors result in increased reliability and reduced costs. Used in any power-distribution system requiring high efficiency, high reliability, low weight, and flexibility to handle variety of sources and loads.

Hansen, Irving G.↗

Stiffness and Damping Coefficient Estimation of Compliant Surface Gas Bearings for Oil-Free Turbomachinery

Foil gas bearings are a key technology in many commercial and emerging Oil-Free turbomachinery systems. These bearings are non-linear and have been difficult to analytically model in terms of performance characteristics such as load capacity, power loss, stiffness and damping. Previous investigations led to an empirically derived method, a rule-of-thumb, to estimate load capacity. This method has been a valuable tool in system development. The current paper extends this tool concept to include rules for stiffness and damping coefficient estimation. It is expected that these rules will further accelerate the development and deployment of advanced Oil-Free machines operating on foil gas bearings

DellaCorte, Christopher↗

Qualification of emerging point-of-load regulators for next generation power systems

As demand for high-speed, on-board, digital-processing integrated circuits (ICs) on spacecraft increases (FPGAs and DSPs in particular), the need for the next generation point-of-load (POL) regulator becomes a prominent design issue. Shrinking process nodes have resulted in core rails dropping to values close to 1.0 V, drastically reducing margin to standard switching converters or regulators that power digital ICs. The objectives of this study are to first identify reliability issues or additional space reliability requirements that might not be addressed for commercial application of POL converters; second, to study the performances of existing or emerging POL converters (including linear regulators) within a practical two-stage power distribution architecture; and, finally, to identify points of failure at extreme temperatures (low and high) beyond specifications.

Leon, Rosa↗

Study of a High Voltage Ion Engine Power Supply

A complete laboratory breadboard version of a ion engine power converter was built and tested. This prototype operated on a line voltage of 80-120 Vdc, and provided output ratings of 1100 V at 1.8 kW, and 250 V at 20 mA. The high-voltage (HV) output voltage rating was revised from the original value of 1350 V at the beginning of the project. The LV output was designed to hold up during a 1-A surge current lasting up to 1 second. The prototype power converter included a internal housekeeping power supply which also operated from the line input. The power consumed in housekeeping was included in the overall energy budget presented for the ion engine converter. HV and LV output voltage setpoints were commanded through potentiometers. The HV converter itself reached its highest power efficiency of slightly over 93% at low line and maximum output. This would dip below 90% at high line. The no-load (rated output voltages, zero load current) power consumption of the entire system was less than 13 W. A careful loss breakdown shows that converter losses are predominately Metal-Oxide-Semiconductor Field Effect Transistor (MOSFET) conduction losses and HV rectifier snubbing losses, with the rectifier snubbing losses becoming predominant at high line. This suggests that further improvements in power efficiency could best be obtained by either developing a rectifier that was adequately protected against voltage overshoot with less snubbing, or by developing a pre-regulator to reduced the range of line voltage on the converter. The transient testing showed the converter to be fully protected against load faults, including a direct short-circuit from the HV output to the LV output terminals. Two currents sensors were used: one to directly detect any core ratcheting on the output transformer and re-initiate a soft start, and the other to directly detect a load fault and quickly shut down the converter for load protection. The finished converter has been extensively fault tested without failure. The finished converter has been packaged suitable for use as a laboratory prototype for further testing. The finished converter is readily transportable. An article on design issues for high voltage converters for ion engines is included as an attachement.

Stuart, Thomas A.↗

Effect of vortex generators on the power conversion performance and structural dynamic loads of the Mod-2 wind turbine

Applying vortex generators from 20 to 100 percent span of the Mod-2 rotor resulted in a projected increase in annual energy capture of 20 percent and reduced the wind speed at which rated power is reached by nearly 3 m/sec. Application of vortex generators from 20 to 70 percent span, the fixed portion of the Mod-2 rotor, resulted in a projected increase in annual energy capture of about half this. This improved performance came at the cost of a small increase in cyclic blade loads in below rated power conditions. Cyclic blade loads were found to correlate well with the change in wind speed during one rotor revolution.

Sullivan, T. L.↗

Fault-tolerant adaptive control for load-following in static space nuclear power systems

The possible use of a dual-loop model-based adaptive control system for load following in static space nuclear power systems is investigated. The proposed approach has thus far been applied only to a thermoelectric space nuclear power system but is equally applicable to other static space nuclear power systems such as thermionic systems.

Parlos, Alexander G.↗

The SPACE Computer Code for Analyzing the International Space Station Electrical Power System: Past, Present, and Future

The System Power Analysis for Capability Evaluation (SPACE) computer code was initially developed by NASA in 1988 to assess the Space Station Freedom electric power system and later adapted to support contractor electrical power system capability analyses for the International Space Station (ISS). Over time, the code has supported many efforts such as ISS redesign activities in the early 1990s, assessment of time-phased loads against power system operating limits for future ISS assembly flights (including Certification of Flight Readiness reviews by the ISS program office), and determining the optimum solar array gimbal positions while respecting keep-out zones which minimize both solar array contamination and structural loads. The code has been validated by comparisons with ISS on-orbit data in multiple validation episodes. Recent updates to the code include the incorporation of a Lithium-Ion battery model in addition to the Nickel Hydrogen battery model and modifications to the solar array degradation model to better match on-orbit test results. SPACE has also been extended beyond the ISS to include modeling of the Orion Multi-Purpose Crew Vehicle electrical power system (SPACE-MPCV) and Mars Surface Electrical Power Systems (MSEPS). Portions of SPACE were integrated with a trajectory code to form a Solar Electric Propulsion Simulation (SEPSim), which can be used for analyzing solar electric propulsion missions. In addition, SPACE methods and subroutines have been adapted to a multitude of other projects. This paper summarizes the initial code development and subsequent code utilization in the context of the overall ISS program development and on-orbit operations. Recent updates and results from the code are discussed, including preliminary analyses for the Orion power system.

Electrical Power System↗

Low-Voltage Protection For Volatile Computer Memories

Short-circuit current provides minimum memory power. Protective circuit includes dc-to-dc converter that supplies keep-alive voltage to memories when short circuit occurs in any of system loads. Converter powered by lowvoltage across two of three series diodes generated by short-circuit bus current. Relay switch is in open (short-circuit-detected) position. Protective circuit useful wherever necessary to improve reliability of volatile memories or other circuits that must not lose power.

Detwiler, R. C.↗

Swept Volume Approach for the Characterization of Pumping Loss of Shrouded Meshed Cylindrical Gears

High speed rotorcraft transmissions are subject to load-independent power losses consisting of drag and pumping loss. Tightly conforming shrouds enclosing the transmission gears are often incorporated to reduce the drag component of the total load-independent losses. However, tightly conforming axial shrouding can result in an increase in the pumping loss component. Quantifying the pumping loss of shrouded gear transmissions has been the subject of many studies. This study presents a new approach for estimating pumping loss based on the concept of swept volume borrowed from the positive displacement pump and compressor industry. In this study, pumping loss of shrouded gear transmissions is considered to be related to the swept volume of the gear sets and the downstream flow resistance created by the shroud clearances. The drag loss and pumping loss of a spur gear pair have been determined through testing using the NASA Glenn Research Center Gear Windage Test Facility. The results from this testing have been compared to theoretical results using the formulations presented in this study. Good correlation exist between the test pumping power loss and the predicted pumping power loss for tightly conforming axial shroud configurations.

Hurrell, Michael J.↗

Pumping Loss of Shrouded Meshed Spur Gears

High speed rotorcraft transmissions are subject to load-independent power losses consisting of drag loss and pumping loss. Tightly conforming shrouds enclosing the transmission gears are often incorporated to reduce the drag component of the total load-independent losses. However, tightly conforming axial shrouds can result in an increase in the pumping loss component. Quantifying the pumping loss of shrouded gear transmissions has been the subject of many studies. This study presents a new approach for estimating pumping loss based on the concept of swept volume and examines the applicability of the approach to various shroud configurations.The drag loss and pumping loss of a shrouded spur gear pair has been determined through testing using the NASAGlenn Research Center (GRC) Gear Windage Test Facility.The results from this testing have been compared to theoretical results using the formulations presented in this study. In addition, computational fluid dynamic (CFD) analysis has been conducted for the various shroud configurations tested at NASA GRC. The results from the CFD analysis confirm the theoretical and empirical results and provide insight into the applicability of the swept volume approach for estimating pumping power loss of shrouded gear transmissions.

Michael J. Hurrell↗

Recent advances in solid polymer electrolyte fuel cell technology with low platinum loading electrodes

High power density fuel cell systems for defense and civilian applications are being developed. Taking into consideration the main causes for efficiency losses (activation, mass transport and ohmic overpotentials) the only fuel cell systems capable of achieving high power densities are the ones with alkaline and solid polymer electrolyte. High power densities (0.8 W/sq cm at 0.8 V and 1 A/sq cm with H2 and O2 as reactants), were already used in NASA's Apollo and Space Shuttle flights as auxiliary power sources. Even higher power densities (4 W/sq cm - i.e., 8 A sq cm at 0.5 V) were reported by the USAF/International Fuel Cells in advanced versions of the alkaline system. High power densities (approximately 1 watt/sq cm) in solid polymer electrolyte fuel cells with ten times lower platinum loading in the electrodes (i.e., 0.4 mg/sq cm) were attained. It is now possible to reach a cell potential of 0.620 V at a current density of 2 A/sq cm and at a temperature of 95 C and pressure of 4/5 atm with H2/O2 as reactants. The slope of the linear region of the potential-current density plot for this case is 0.15 ohm-sq cm. With H2/air as reactants and under the same operating conditions, mass transport limitations are encountered at current densities above 1.4 A/sq cm. Thus, the cell potential at 1 A/sq cm with H2/air as reactants is less than that with H2/O2 as reactants by 40 mV, which is the expected value based on electrode kinetics of the oxygen reduction reaction, and at 2 A/sq cm with H2/air as reactant is less than the corresponding value with H2/O2 as reactants by 250 mV, which is due to the considerably greater mass transport limitations in the former case.

Srinivasan, Supramaniam↗

Complementary MOS four-phase logic circuits

Technique can provide four-phase clock signal from single-phase clock and requires only one power supply voltage. This arrangement saves considerable power compared to circuits having load resistor between power supply and ground.

Petersen, H. L.↗

Performance analysis of radiation cooled dc transmission lines for high power space systems

As space power levels increase to meet mission objectives and also as the transmission distance between power source and load increases, the mass, volume, power loss, and operating voltage and temperature become important system design considerations. This analysis develops the dependence of the specific mass and percent power loss on hte power and voltage levels, transmission distance, operating temperature and conductor material properties. Only radiation cooling is considered since the transmission line is assumed to operate in a space environment. The results show that the limiting conditions for achieving low specific mass, percent power loss, and volume for a space-type dc transmission line are the permissible transmission voltage and operating temperature. Other means to achieve low specific mass include the judicious choice of conductor materials. The results of this analysis should be immediately applicable to power system trade-off studies including comparisons with ac transmission systems.

Schwarze, G. E.↗

Performance analysis of radiation cooled dc transmission lines for high power space systems

As space power levels increase to meet mission objectives and also as the transmission distance between power source and load increases, the mass, volume, power loss, and operating voltage and temperature become important system design considerations. This analysis develops the dependence of the specific mass and percent power loss on the power and voltage levels, transmission distance, operating temperature and conductor material properties. Only radiation cooling is considered since the transmission line is assumed to operate in a space environment. The results show that the limiting conditions for achieving low specific mass, percent power loss, and volume for a space-type dc transmission line are the permissible transmission voltage and operating temperature. Other means to achieve low specific mass include the judicious choice of conductor materials. The results of this analysis should be immediately applicable to power system trade-off studies including comparisons with ac transmission systems.

Schwarze, G. E.↗

An evaluation of HEMT potential for millimeter-wave signal sources using interpolation and harmonic balance techniques

A large-signal analysis method based on an harmonic balance technique and a 2-D cubic spline interpolation function has been developed and applied to the prediction of InP-based HEMT oscillator performance for frequencies extending up to the submillimeter-wave range. The large-signal analysis method uses a limited number of DC and small-signal S-parameter data and allows the accurate characterization of HEMT large-signal behavior. The method has been validated experimentally using load-pull measurement. Oscillation frequency, power performance, and load requirements are discussed, with an operation capability of 300 GHz predicted using state-of-the-art devices (fmax is approximately equal to 450 GHz).

Kwon, Youngwoo↗

Ni/NiCI(2) Reference Electrodes For Na/NiCI(2) Cells

Reference electrodes made of nickel cores with surface layers of nickel chloride proposed for use in molten sodium tetracholoroaluminate electrolytes in experimental sodium/nickel chloride electrochemical cells. These and other sodium/metal chloride cells investigated for use in several applications, including powering electric vehicles and leveling loads in power-distribution systems. Offers potential advantages of greater durability, greater stability and reproducibility of electrochemical potentials, less sensitivity of electrochemical potentials to variations in compositions of electrolytes, and greater compatibility with cathodes, made of nickel chloride.

Bugga, Ratnakumar↗