Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “limiting techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Emerging Electrochemical Techniques for Probing Site Behavior in Single-Atom Electrocatalysts

Single-atom catalysts (SACs) have aroused tremendous interest over the past decade, particularly in the community of energy and environment-related electrocatalysis. A rapidly growing number of recent publications have recognized it as a promising candidate with maximum atomic utilization, distinct activity, and selectivity in comparison to bulk catalysts and nanocatalysts. However, the complexity of localized coordination environments and the dispersion of isolated sites lead to significant difficulties when it comes to gaining insight into the intrinsic behavior of electrocatalytic reactions. Furthermore, the low metal loadings of most SACs make conventional ensemble measurements less likely to be accurate on the subnanoscale. Thus, it remains challenging to probe the activity and properties of individual atomic sites by available commercial instruments and analytical methods. In spite of this, continuing efforts have lately focused on the development of advanced measurement methodologies, which are very useful to the fundamental understanding of SACs. There have recently been a number of in situ/operando techniques applied to SACs, such as electron microscopy, spectroscopy, and other analysis methods, which support relevant functions to identify the active sites and reaction intermediates and to investigate the dynamic behavior of localized structures of the catalytic sites. This Account aims to present recent electrochemical probing techniques which can be used to identify single-atomic catalytic sites within solid supports. First, we describe the basic principles of molecular probe methods for the study and analysis of electrocatalytic site behavior. In particular, the in situ probing technique enabled by surface interrogation scanning electrochemical microscopy (SISECM) can measure the active site density and kinetic rate with high resolution. An alternative electrochemical probing technique is further demonstrated on the basis of single-entity electrochemistry, which allows the unique electrochemical imaging of the size and catalytic rate of single atoms, molecules, and clusters. Next, the merits and limitations of different electrochemical techniques are then discussed, along with perspectives for future prospects. Apart from this, we further showcase the powerful capability of emerging electrochemical probing techniques for determining significant effects and properties of SACs for various electrocatalytic reactions, including oxygen reduction and evolution, hydrogen evolution, and nitrate reduction. Overall, electrochemical techniques with atomic resolution have greatly increased opportunities for observing, measuring, and understanding the surface and interface chemistry during energy conversion. In the future, it is anticipated that the development of electrochemical probing techniques will be advanced with innovative perspectives on the behavior and features of SACs. We hope that this Account can contribute in several ways to promoting the fundamental knowledge and technical progress of emerging electrochemical measurements for studying SACs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Visible-to-THz near-field nanoscopy

Optical microscopy has a key role in research, development and quality control across a wide range of scientific, technological and medical fields. However, diffraction limits the spatial resolution of conventional optical instruments to about half the illumination wavelength. A technique that surpasses the diffraction limit in the wide spectral range between visible and terahertz frequencies is scattering-type scanning near-field optical microscopy (s-SNOM). The basis of s-SNOM is an atomic force microscope in which the tip is illuminated with light from the visible to the terahertz spectral range. By recording the elastically tip-scattered light while scanning the sample below the tip, s-SNOM yields near-field optical images with a remarkable resolution of 10 nm, simultaneously with the standard atomic force microscopic topography image. This resolution is independent of the illumination wavelength, rendering s-SNOM a versatile nanoimaging and nanospectroscopy technique for fundamental and applied studies of materials, structures and phenomena. This Review presents an overview of the fundamental principles governing the measurement and interpretation of near-field contrasts and discusses key applications of s-SNOM. We also showcase emerging developments that enable s-SNOM to operate under various environmental conditions, including cryogenic temperatures, electric and magnetic fields, electrical currents, strain and liquid environments. Furthermore, all these recent developments broaden the applicability of s-SNOMs for exploring fundamental solid-state and quantum phenomena, biological matter, catalytic reactions and more.

Hillenbrand, Rainer [CIC nanoGUNE BRTA and Departm↗

Quantification of Inactive Lithium and Solid–Electrolyte Interphase Species on Graphite Electrodes after Fast Charging

Rapid charging of Li-ion batteries is limited by lithium plating on graphite anodes, whereby Li+ ions are reduced to Li metal on the graphite particle surface instead of inserting between graphitic layers, which directly contributes to cell capacity loss because of the low reversibility of the Li plating/stripping process. Furthermore, precisely identifying the onset and amount of Li plating is therefore vital in order to remedy these issues. We demonstrate a titration technique with a detection limit of 20 nmol (5 × 10 –4 mAh) of Li that can be used to quantify inactive Li that remains on the graphite electrode after fast charging. The titration is extended to quantify the total amount of solid carbonate species and lithium acetylide (Li 2 C 2 ) within the solid–electrolyte interphase (SEI), and electrochemical modeling is used to determine the Li plating exchange current density (10 A/m 2 ) and stripping efficiency (65%) of plated Li metal on graphite. These techniques provide a highly accurate measure of the onset of Li plating and quantitative insight into graphite SEI evolution during fast charging.

25 ENERGY STORAGE↗

The Effects of Manufacturing Techniques on Neutron-Irradiated C26M Mechanical Properties

Nuclear energy provides 13% of the total energy produced globally. To further improve the safety and reliability of nuclear reactors material challenges need to be successfully resolved. C26M/FeCrAl alloy systems can improve the safety and reliability of current Generation III reactors due to the potential benefits of a stable passivation layer from the Al, which can protect against corrosion, and promising mechanical performance at boiling- and light-water reactor temperatures. However, information is limited on how manufacturing techniques affect the mechanical performance of C26M in neutron-irradiated environments. In this research, C26M specimens were manufactured using three techniques and then irradiated at the Advanced Test Reactor at Idaho National Laboratory. This research aims to bridge this gap by investigating how the manufacturing techniques affects the mechanical performance of irradiated C26M at Generation III reactor relevant temperatures.

36 - MATERIALS SCIENCE↗

Bi-Filar Coil Winding for Fast Quench Protection

As superconducting magnet technology is pushed towards higher performance, energy density and total stored energy follow exponentially. Protecting magnets becomes substantially more challenging with traditional methods being stretched to their limits. New technologies such as CLIQ (Coupling Loss Induced Quench) promise to provide a robust method to protect advanced magnets, however they become inductance limited in large magnet strings or at low field, leading to more complex configurations. A technique to substantially reduce this limitation and improve response time is presented, by winding coils in a bifilar fashion and connecting them in series for typical operation, while providing an anti-parallel connection for quasi-zero-inductance in a protection case. This allows for extremely high di/dt. The concept is then demonstrated on a small REBCO coil.

43 PARTICLE ACCELERATORS↗

Bi-Filar Coil Winding for Fast Quench Protection

As superconducting magnet technology is pushed towards higher performance, energy density and total stored energy follow exponentially. Protecting magnets becomes substantially more challenging with traditional methods being stretched to their limits. New technologies such as CLIQ promise to provide a robust method to protect advanced magnets, however they become inductance limited in large magnet strings or at low field, leading to more complex configurations. A technique to substantially reduce this limitation and improve response time is presented, by winding a coil in a bifilar fashion. This allows for extremely high di/dt. The concept is then demonstrated on a small REBCO coil.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High sensitivity measurement of femtogram-level 238 Pu by thermal ionization mass spectrometry with correction of background 238 U

Low-concentration plutonium isotopic measurements provide a valuable fingerprint to identify possible material origins in the context of environmental contamination monitoring, environmental tracing, nuclear safeguards, nuclear forensics, and treaty monitoring. Thermal ionization mass spectrometry (TIMS) has long been recognized as one of the most sensitive techniques for plutonium isotopic measurement, but has not generally been utilized for 238 Pu determination, especially at low concentrations, due to an isobaric interference from 238 U, prevalent as background. Here, this work demonstrates a new analytical technique for correction of background 238 U from the 238 Pu counts collected during a TIMS analysis. The technique takes advantage of the higher ionization temperature of U relative to Pu and uses a 235 U tracer added after plutonium purification chemistry for 238 U semi-quantitative determination. This technique has been successfully applied to the determination of 238 Pu concentration and the 238 Pu/ 239 Pu ratio in sample types including single-isotope standards, isotopic certified reference materials, matrix-containing environmental reference materials, and simulated nuclear detonation debris. The results have been directly compared on a sample-by-sample basis to alpha spectrometry results. The detection limit by this new technique is 0.23 fg 238 Pu, which was previously unachievable by mass spectrometry and is possible in around 1 h of analysis time post-chemistry compared to weeks of required counting time by alpha spectrometry (at the same atom amount). We also present original, high precision data for Pu isotope concentrations in IAEA-384, Fangataufa Sediment, including 242 Pu results for the first time. The new technique allows measurement of a key isotope, 238 Pu, that was previously not measured in small environmental or nuclear forensics collections.

238Pu↗

Multiscale Characterization of Additive Manufacturing Components with Computed Tomography, 3D X-ray Microscopy, and Deep Learning

Additive manufacturing (AM) facilitates the creation of complex-geometry parts, driving advancements in lightweight aerospace components, high-efficiency engine cooling channels, and customized medical implants. However, ensuring the quality and reliability of AM parts remains challenging due to internal defects, surface irregularities, porosity, and residual trapped powder, which are often inaccessible to traditional inspection methods. Recent developments in X-ray computed tomography (XCT) and 3D X-ray microscopy (XRM), particularly systems equipped with resolution-at-a-distance (RaaD™) capabilities, enable high-resolution, non-destructive evaluation of AM components across multiple scales, from sub-micrometer to macroscopic levels. This paper explores modern XCT and XRM techniques for multiscale characterization of AM parts, focusing on their ability to detect and analyze defects such as porosity, cracks, inclusions, and surface roughness, while offering insights into defect formation mechanisms, material properties, and process-induced variations. The integration of deep learning (DL) frameworks, including Simurgh, DeepRecon, and DeepScout, enhances XCT/XRM workflows by reducing scan times, improving resolution recovery, and enabling accurate defect detection even with limited projection data. These DL-based methods overcome limitations of traditional reconstruction techniques, enabling faster, more reliable characterization of dense materials like Inconel 718 and novel alloys such as AlCe. Applications include process parameter optimization, high-throughput quality control, and multistage AM process evaluation, with DL-enhanced workflows accelerating analysis times from weeks to days. Correlative imaging approaches further validate XCT and XRM data against scanning electron microscopy (SEM) images of physically sectioned samples, confirming the accuracy of DL-based reconstructions and enabling comprehensive defect analysis. While challenges remain in generalizing DL models to diverse materials and imaging conditions, improvements in resolution, noise reduction, and defect detection highlight the transformative potential of these methods. This multiscale and correlative approach enables precise identification and correlation of microstructural features with the overall performance of AM components. By integrating advanced XCT, XRM, and DL techniques, this paper demonstrates a significant leap forward in AM characterization, offering valuable insights into the relationships between processing parameters, microstructure, and part performance, and driving innovations that enhance the quality and reliability of AM products for demanding industrial applications.

Additive manufacturing↗

A High-Speed, High-Resolution Transition Edge Sensor Spectrometer for Soft X-Rays at the Advanced Photon Source

This project explores the design and development of a transition edge sensor (TES) spectrometer for resonant soft X-ray scattering (RSXS) measurements developed in collaboration between Argonne National Laboratory (ANL) and the National Institute of Standards and Technology (NIST). Soft X-ray scattering is a powerful technique for studying the electronic and magnetic properties of materials on a microscopic level. However, the lack of high-performance soft X-ray spectrometers has limited the potential of this technique. TES spectrometers have the potential to overcome these limitations due to their high energy resolution, high efficiency, and broad energy range. This project aims to optimize the design of a TES spectrometer for RSXS measurements and more generally soft X-ray spectroscopy at the Advanced Photon Source (APS) 29-ID, leading to improved understanding of advanced materials. We will present a detailed description of the instrument design and implementation. The spectrometer consists of a large array of approximately 250 high-speed and high-resolution pixels. The pixels have saturation energies of approximately 1 keV, sub-ms pulse duration and energy resolution of approximately 1 eV. The array is read out using microwave multiplexing chips with MHz bandwidth per channel, enabling efficient data throughput. To facilitate measurement of samples in situ under ultra-high vacuum conditions at the beamline, the spectrometer is integrated with an approximately 1 m long snout.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of Photovoltaic Module Deformation Dynamics During Hail Impact Using Digital Image Correlation

Stereo high-speed video of photovoltaic modules undergoing laboratory hail tests was processed using digital image correlation to determine module surface deformation during and immediately following impact. The purpose of this work was to demonstrate a methodology for characterizing module impact response differences as a function of construction and incident hail parameters. Video capture and digital image analysis were able to capture out-of-plane module deformation to a resolution of ±0.1 mm at 11 kHz on an in-plane grid of 10 × 10 mm over the area of a 1 × 2 m commercial photovoltaic module. With lighting and optical adjustments, the technique was adaptable to arbitrary module designs, including size, backsheet color, and cell interconnection. Furthermore, impacts were observed to produce an initially localized dimple in the glass surface, with peak deflection proportional to the square root of incident energy. Subsequent deformation propagation and dissipation were also captured, along with behavior for instances when the module glass fractured. Natural frequencies of the module were identifiable by analyzing module oscillations postimpact. Limitations of the measurement technique were that the impacting ice ball obscured the data field immediately surrounding the point of contact, and both ice and glass fracture events occurred within 100 μs, which was not resolvable at the chosen frame rate. Increasing the frame rate and visualizing the back surface of the impact could be applied to avoid these issues. Applications for these data include validating computational models for hail impacts, identifying the natural frequencies of a module, and identifying damage initiation mechanisms.

14 SOLAR ENERGY↗

Filling data analysis gaps in time-resolved crystallography by machine learning

There is a growing understanding of the structural dynamics of biological molecules fueled by x-ray crystallography experiments. Time-resolved serial femtosecond crystallography (TR-SFX) with x-ray Free Electron Lasers allows the measurement of ultrafast structural changes in proteins. Nevertheless, this technique comes with some limitations. One major challenge is the quality of data from TR-SFX measurements, which often faces issues like data sparsity, partial recording of Bragg reflections, timing errors, and pixel noise. To overcome these difficulties, conventionally, large volumes of data are collected and grouped into a few temporal bins. The data in each bin are then averaged and paired with the mean of their corresponding jittered timestamps. This procedure provides one structure per bin, resulting in a limited number of averaged structures for the entire time interval spanned by the experiment. Therefore, the information on ultrafast structural dynamics at high temporal resolution is lost. This has initiated research for advanced methods of analyzing experimental TR-SFX data beyond the standard binning and averaging method. To address this problem, we use a machine learning algorithm called Nonlinear Laplacian Spectral Analysis (NLSA), which has emerged as a promising technique for studying the dynamics of complex systems. In this work, we demonstrate the power of this algorithm using synthetic x-ray diffraction snapshots from a protein with significant data incompleteness, timing uncertainties, and noise. Our study confirms that NLSA is a suitable approach that effectively mitigates the effects of these artifacts in TR-SFX data and recovers accurate structural dynamics information hidden in such data.

Trujillo, Justin (ORCID:0000000285505360)↗

Conducting polymer-based electrochemical sensors: Progress, challenges, and future perspectives

Conducting polymers are promising due to their unique properties, such as excellent electrical and optical properties, physical and chemical stability, high conductivity, and effective redox properties with high-temperature stability and biocompatibility. Due to these properties, conducting polymers are useful in diverse applications like sensors, batteries, oil industries, biosensors, biomedicines, catalysis, cancer treatment, etc. This review article aims to discuss the recent trends and analysis of conducting polymer-based electrochemical sensors in diverse areas with all required sensor characteristics, such as the derived limit of detection, utilized techniques for the sensing analysis and derived linear dynamic range with the stability of the sensors. Conducting polymers and their nanocomposites-based electrochemical sensors have demonstrated exceptional capabilities towards detecting various biomolecules, heavy metals, pesticides, and viruses like SARS-COV-2. Incorporation of redox mediators, use of conducting hydrogels, and molecular imprinting are promising strategies for better performance of the derived sensor. The article has demonstrated the existing challenges and limitations and provided solutions in the field. In the future, conducting polymers-based electrochemical sensors can be utilized in wearable sensors and integrated with IoT devices for better reach in real-time applications. They can also be made more accessible with precise control and data output by following specific methodologies. Utilizing green and sustainable conducting polymers can be crucial in advancing eco-friendly practices in the future. Conducting polymer-based electrochemical sensors has affectivity in neurochemical and pathogen sensing, which is essential for brain function and mental health.

42 ENGINEERING↗

Small-correlated-against-large estimator for the lensing of the cosmic microwave background

Weak gravitational lensing of the cosmic microwave background (CMB) carries imprints of the physics operating at redshifts much lower than that of recombination and serves as an important probe of cosmological structure formation, dark matter physics, and the mass of neutrinos. Reconstruction of the CMB lensing deflection field through use of quadratic estimators has proven successful with existing data but is known to be sub-optimal on small angular scales ($\ell > 3000$) for experiments with low noise levels. Future experiments will provide better observations in this regime, but these techniques will remain statistically limited by their approximations. We show that correlations between fluctuations of the large-scale temperature gradient power of the CMB sourced by $\ell < 2000$, and fluctuations of the local small-scale temperature power reveal a lensing signal which is prominent in even the real-space pixel statistics across a CMB temperature map. We present the development of the Small Correlated Against Large Estimator (SCALE), a novel estimator for the CMB lensing spectrum which offers promising complementary analysis alongside other reconstruction techniques in this regime. The SCALE method computes correlations between both the large/small-scale temperature gradient power in harmonic space, and it is able to quantitatively recover unbiased statistics of the CMB lensing field without the need for map-level reconstruction. SCALE can outperform quadratic estimator signal-to-noise by a factor of up to 1.5 in current and upcoming experiments for CMB lensing power spectra $C_{6000 < L < 8000}^{\phi\phi}$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Application of emerging monitoring techniques at the Illinois Basin – Decatur Project

The Illinois Basin – Decatur Project is a large-scale carbon capture and storage demonstration project located in Decatur, Illinois, USA. In this project, one million metric tons of carbon dioxide (CO 2 ) was captured from an ethanol production facility and successfully injected into a deep saline reservoir over a period of three years. The scale of this project presented an opportunity to explore emerging technologies for effective long-term monitoring of the carbon capture and storage site. This research documents the application of three emerging monitoring techniques: (1) a prototype “open-path” sensor, a method of continuously monitoring atmospheric CO 2 by applying tunable diode laser absorption spectroscopy to provide a warning system for personnel safety along pipelines and at wellheads; (2) the Greenhouse Gas Laser Imaging Tomography Experiment (GreenLITE), an automated system for measuring two-dimensional spatial distribution of atmospheric CO 2 concentrations; and (3) periodic aerial imagery, a method of documenting surface-vegetation dynamics to detect vegetative responses to CO 2 leaks. The objective of this work was to assess the advantages and limitations of these monitoring techniques and quantify their reliability over an extended deployment at an active industrial site. These results will aid in determining viability of long-term monitoring on a commercial scale.

42 ENGINEERING↗

From pixels to patterns: Coupling Optical Coherence Tomography and machine learning for monitoring coastal wetland root systems

Coastal wetlands are crucial in shoreline stabilization, carbon sequestration, and storm protection. Yet, due to limitations in traditional destructive sampling techniques, the belowground biomass (live root mass) and necromass (dead and decaying roots) remain difficult to assess in coastal wetlands, limiting our understanding on coastal resilience, nutrient cycling, and soil structure. This study employs Optical Coherence Tomography (OCT) as a high-resolution imaging technique to analyze root biomass and necromass in the Terrebonne Basin, Louisiana. A Random Forest (RF) model was developed to classify root health states based on OCT-derived features, achieving an accuracy of 70% in distinguishing live from dead root segments. The results demonstrate that OCT, combined with ML, offers a promising novel approach to root analysis, providing fine-scale insights into root morphology and decay patterns that are not easily captured by conventional methods. This research lays the foundation for future integration of OCT with complementary imaging modalities such as X-ray Computed Tomography (XCT) and advanced ML algorithms to enhance classification accuracy and scalability. Future work aims to expand the dataset diversity across different wetland types and apply the methodology for large-scale, repeatable assessments of root biomass turnover and accumulation, with important implications for wetland monitoring, conservation, and restoration under changing environmental conditions.

AI/ML↗

Securing Smart Manufacturing: Detection of Cyber-Physical Attacks in CNC-Based Systems

As Industry 4.0 advances, the integration of computer numerical control (CNC) machines and advanced manufacturing technologies is transforming production into smart manufacturing systems that blend physical and digital processes as cyber-physical systems. However, this increased cyber-physical connectivity exposes manufacturing systems to cyber threats that can cause severe operational and financial disruptions. This paper presents a comparative study on cyber attacks and anomaly detection techniques in manufacturing, focusing on network traffic from CNC machines. The data extracted from network packets includes machine commands and control signals exchanged between the machine's interface and control system, crucial for maintaining operational integrity. We explore two types of cyber attacks, design modification and command injection, which pose substantial risks to CNC machine productivity and system integrity. Our investigation involves experiments on a real CNC system, highlighting the urgent need for effective detection mechanisms. To address these threats, we evaluate three anomaly detection methods: dynamic time warping (DTW), rolling average, and a deep learning, long short-term memory (LSTM) time-series-based autoencoder. Each is assessed for its effectiveness in identifying anomalous behaviors caused by the attacks. Our findings demonstrate the unique strengths and limitations of each detection technique, providing a deeper understanding of their applicability in realworld manufacturing environments. The comparative analysis indicates that while certain methods are highly effective against specific attack types, others offer broader applicability across different attacks. This study contributes to the accurate detection of anomalies in CNC machining processes, thereby enhancing the reliability and security of smart manufacturing systems against diverse cyber threats.

Williams, Bethanie [Tennessee Technological Univer↗

Improvements to the Modeling of the TREAT Reactor and Experiments

This paper summarizes the latest improvements and lessons learned from the modeling and simulation of the transient test reactor at Idaho National Laboratory using the MAM- MOTH reactor physics application. MAMMOTH is a MOOSE-based, Finite Element Method application that specializes in the analysis of the spatial dynamics behavior of nuclear reactors. Since early 2018 several transient tests have been conducted at TREAT, thus providing the opportunity to apply and benchmark modern modeling and simulation tools. MAMMOTH was used to provide predictions of the power coupling factor between the core and the experiment for various experiments. Even though the power coupling factor predictions agree very well with the experimental data, within the bounds of the experimental uncertainty, one shortcoming was the underprediction of the total energy deposited in the core and in the experiment. Determination of the sources for this discrepancy are ongoing, but several key problems have been identified and resolved, thus providing valuable insights for future research. This paper discusses several of these lessons learned. First, the heat capacity data for the TREAT fuel has some significant problems due to limitations of the measurement techniques used circa 1960s. The sensitivity of the peak power and the total energy deposition to various representations of the heat capacity is approximately 5%. Second, the effects of the biological shield and thermal column on the modeling of the core are non-negligible, since they affect the mean generation time and the effective reflection of neutrons back into the core, which is suspected to be important during the core heat up. Matching the reactor period resolves the fact that the reduced spatial domain used in the MAMMOTH model underpredicts the mean generation time. The neutron reflection from these regions is marginally improved with the use of an albedo boundary condition. Third, modeling of the control rod movement with a multi-scheme method is introduced and its current limitations are exposed. Fourth, we explore the effects of using a homogenized model with Superhomogenization equivalence and how that differs from fully heterogeneous simulations. Finally, the energy condensation effects for this graphite core are significant. Solutions with 10 and 26 energy groups show the benefits of using a finer coarse group structure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗