Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “laser operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Measurement of the QE Map

113 MHz SRF gun utilized CsK 2 Sb and Na 2 KSb cathodes, which were irradiated with a pulsed green laser with a wavelength of 0.53 microns. The drive laser generated 78 kHz pulses with an acousto-optic modulator selecting the desired number of pulses reaching the cathode. The operator can select the aperture size, defining the laser spot diameter on the cathode, and the power level, which is controlled by a rotating polarizer. The laser power reaching the cathode can be measured with a meter based on a photodiode. The quantum efficiency (QE) of a photocathode serves as a primary indicator of its state. Small QE renders the cathode unusable when the desired bunch charge cannot be achieved. Strong variations in the quantum efficiency on the cathode surface might lead to the growth of the beam emittance due to the space charge effects. We have created a routine to measure the distribution of the QE on the cathode. The operator selects the aperture size, the central spot location, and the scan ranges for both planes. The scan starts from the central spots and proceeds along a spiral-like trajectory, making N rounds. The number of rounds can be chosen, and the total number of measured points is (2N+1) 2 . The laser spot movement is shown in Fig. 1.

43 PARTICLE ACCELERATORS↗

Shaping Micro-Bunched Electron Beams for Compact X-ray Free-Electron Lasers with Transverse Gradient Undulators

Laser-modulator-based micro-bunching of electron beams has been applied to many novel operating modes of X-ray free-electron lasers from harmonic generation to attosecond pulse production. Recently, it was also identified as a key enabling technology for the production of a compact XFEL driven by a relatively low-energy beam. In traditional laser modulator schemes with low-energy and high-current bunches, collective effects limit the possible working points that can be employed, and thus it is difficult to achieve optimal XFEL performance. We propose to utilize transverse longitudinal coupling in a transverse gradient undulator (TGU) to shape micro-bunched electron beams so as to optimize their performance in a compact X-ray free-electron laser. We show that a TGU added to a conventional laser modulator stage enables much more flexibility in the design, allowing one to generate longer micro-bunches less subject to slippage effects and even lower the slice emittance of the micro-bunches. We present a theoretical analysis of laser-based micro-bunching with an added TGU, simulation of compression with collective effects in such systems, and finally XFEL simulations demonstrating the gains in peak power enabled by the TGU. Although we focus on the application to compact XFELs, what we propose is a general phase space manipulation that may find utility in other applications as well.

eSASE↗

Multi-operation tool for photovoltaic cell processing

Multi-operation tools for photovoltaic cell processing are described. In an example, a multi-operation tool includes a conveyor system to move a photovoltaic (PV) cell continuously along a conveyor path through a laser scribing station and an adhesive printing station. Furthermore, the PV cell may be aligned to a laser head of the laser scribing station and a printer head of the adhesive printing station in a single alignment operation prior to being laser scribed and printed with an adhesive in a continuous process.

Beckett, Nathan Phillips↗

Residual strain and microstructure evolution in 316L stainless steel fabricated by hybrid additive/subtractive manufacturing

The extreme thermal gradients in additive manufacturing (AM) result in residual strains. Subsequent machining operations can relieve the AM strains but can introduce additional strains. AM and machining on the same platform, also called interleaving, during hybrid manufacturing has been shown to improve productivity. However, the impacts of these operations on the resulting residual strains are not well understood. In this investigation, neutron diffraction was used to measure residual strains in hybrid manufactured 316L stainless steel where blown-powder laser directed energy deposition (DED), and machining operations were interleaved in 1-inch intervals. We observe that the dominant texture developed during AM, resulting from different spot sizes and deposition parameters, significantly affects residual strain evolution. A dominant <011> texture along the build direction does not show any strain localization during interleaved deposition and machining whereas a dominant <001> texture shows strong tensile strain localization consistent with the pauses for machining at the end of AM step. Using coolant during machining can further alter the residual strain evolution. Our work shows that a combination of AM parameters and machining strategy can be used to influence the nature and magnitude of residual strains in components fabricated using convergent manufacturing technologies.

Hybrid manufacturing↗

Beam Performance of the Positron Transport Line for CEBAF Positron Upgrade

The Low Energy Recirculator Facility (LERF) at Jefferson Lab, formerly operated for the Free-Electron Laser program, has been proposed as the injector complex for the planned 12 GeV CEBAF positron upgrade (Ce+BAF), with an additional pathway to support a potential 22 GeV CEBAF electron upgrade. In this configuration, LERF would generate and pre-accelerate positrons to 123 MeV, matching the present injection energy into the North Linac. Due to the relatively large emittance expected from the positron source, a comprehensive acceptance study has been performed from LERF through the CEBAF recirculating linacs and beam transport lines to the experimental halls. The objective is to establish the positron phase-space acceptance and provide design feedback to the positron production and capture systems. Furthermore, given CEBAF’s capability to deliver highly polarized beams, spin-tracking simulations have been carried out including magnet imperfections, alignment errors, and synchrotron-radiation–induced energy spread. Particular attention is given to the evolution of the spin tune and the corresponding depolarization mechanisms along the beam delivery path, especially for providing longitudinal polarization at the experimental halls. These results inform injector design choices and assess the overall feasibility of delivering high-polarization positron beams in CEBAF.

Ogur, S. [Thomas Jefferson National Accelerator Fa↗

Mid-infrared trace detection with parts-per-quadrillion quantitation accuracy: Expanding frontiers of radiocarbon sensing

Detection sensitivity is a critical characteristic to consider during selection of spectroscopic techniques. However, high sensitivity alone is insufficient for spectroscopic measurements in spectrally congested regions. Two-color cavity ringdown spectroscopy (2C-CRDS), based on intra-cavity pump–probe detection, simultaneously achieves high detection sensitivity and selectivity. This combination enables mid-infrared detection of radiocarbon dioxide ( 14 CO 2 ) molecules in room-temperature CO 2 samples, with 1.4 parts-per-quadrillion (ppq, 10 − 15 ) sensitivity (average measurement precision) and 4.6-ppq quantitation accuracy (average calibrated measurement error for 21 samples from four separate trials) demonstrated on samples with 14 C/C up to ∼ 1.5 × natural abundance ( ∼ 1,800 ppq). These highly reproducible measurements, which are the most sensitive and quantitatively accurate in the mid-infrared, are accomplished despite the presence of orders-of-magnitude stronger, one-photon signals from other CO 2 isotopologues. This is a major achievement in laser spectroscopy. A room-temperature-operated, compact, and low-cost 2C-CRDS sensor for 14 CO 2 benefits a wide range of scientific fields that utilize 14 C for dating and isotope tracing, most notably atmospheric 14 CO 2 monitoring to track CO 2 emissions from fossil fuels. The 2C-CRDS technique significantly enhances the general utility of high-resolution mid-infrared detection for analytical measurements and fundamental chemical dynamics studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pressure Gain, Stability, and Operability of Methane/Syngas Based RDEs Under Steady and Transient Conditions (Final Project Report)

The scope of this work addresses key issues associated with losses associated with the detonation wave and other processes internal to the RDE operation, as well as it develops modeling tools for the evaluation of these losses and exhaust emissions in RDEs. The main challenge in studying RDEs is that RDE performance is highly reliant on the specifics of the design so much so that simple/canonical systems alone cannot provide useful engineering information, but practical RDE designs are sufficiently complex and involve extreme operational environments that detailed access either experimentally (laser diagnostics, for instance) or computationally (direct numerical simulations) are as yet to become practical. To overcome this challenge, we have conducted a combined experimental/simulation/analytical study investigating key phenomena that control the characteristics of operation of RDEs. As a result, the study has developed tools and methods that can be used to evaluate performance and design approaches using reduced-physics models, with the assumptions validated using detailed simulations, and the model prediction tested using experimental observations. The specific objectives of the research were: (1) Develop and demonstrate a low-loss fully axial injection concept, taking advantage of stratification effects to alter the detonation structure and position the wave favorably within the combustor; (2) Obtain stability and operability characteristics of an RDE across operating conditions to aid in the development of operability and performance rules for the operations of other systems; and (3) Develop quantitative metrics for performance gain as well as quantitative description of the loss mechanisms through a combination of diagnostics development, reduced-order modeling, and detailed simulations. The work conducted here has made contribution on design of low-loss inlets that has broad application within the power generation industry for use with pressure gain combustion. The operability and stability of different designs, while focusing on axial air inlet designs, has been analyzed. The effect of nozzle and injection conditions was studied. Models and simulations of exhaust emissions, focusing on NOx emission has been developed and used to investigate how operation of the RDE affect NOx production using Lagrangian analysis of RDE simulations. This work has built on previous programs, with the goal of further understanding operation of RDEs and elevate the readiness of design consideration. In addition, a suite of diagnostic and modeling tools have been developed to obtain quantitative metrics on performance based on measurements, which can be readily transferred to other experimental configurations.

08 HYDROGEN↗

Design of a Thomson scattering diagnostic for the SMall Aspect Ratio Tokamak (SMART)

Here, we describe the design of a Thomson scattering (TS) diagnostic to be used on the SMall Aspect Ratio Tokamak (SMART). SMART is a spherical tokamak being commissioned in Spain that aims to explore positive triangularity and negative triangularity plasma scenarios at a low aspect ratio. The SMART TS diagnostic is designed to operate at high spatial resolution, 6 mm scattering length in the low-field side and 9 mm in the high-field side regions, and a wide dynamic range, electron temperature from 1 eV to 1 keV and density from 5 x 10 18 m -3 to 1 x 10 20 m -3 ⁠, to resolve large gradients formed at the plasma edge and in the scrape-off layer (SOL) under different triangularities and low aspect ratios. A 2 J @1064 nm laser will be used that is capable of operating in the burst mode at 1, 2, and 4 kHz to investigate fast phenomena and at 30 Hz to study 1 s (or more) long discharges. The scattered light will be collected over an angular range of 60° – 120° from 28 spatial points in the midplane covering the entire plasma width and the outer midplane SOL. Each scattering signal will be spectrally resolved on five wavelength channels of a polychromator to obtain the electron temperature measurement. We will also present a method to monitor in situ laser alignment in the core during calibrations and plasma operations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pushing the performance limits of long wavelength interband cascade lasers using innovative quantum well active regions

Here, we report significantly enhanced device performance in long wavelength interband cascade lasers (ICLs) by employing a recently proposed innovative quantum well (QW) active region containing strained InAsP layers. These ICLs were able to operate at wavelengths near 14.4 μm, the longest ever demonstrated for III–V interband lasers, implying great potential of ICLs to cover an even wider wavelength range. Also, by applying the aforesaid QW active region configuration on ICLs at relatively short wavelengths, ICLs were demonstrated at a low threshold current density (e.g., 13 A/cm 2 at 80 K) and at temperatures up to 212 K near 12.4 μm, more than 50 K higher than the previously reported ICLs with the standard W-shape QW active region at similar wavelengths. This suggests that the QW active region with InAsP layers can be used to improve device performance at the shorter wavelengths.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advanced Polymer Characterization: Modular Operations for Spectral Alignment by Iterative Compression (MOSAIC)

Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry encodes structural information across diverse homo- and copolymer ensembles, yet decrypting these spectra requires a systematic analytical approach. We introduce Modular Operations for Spectral Alignment by Iterative Compression (MOSAIC)─a general cipher algorithm that applies modular arithmetic to filter monomer-derived mass contributions and cluster MALDI peaks by nonconstitutional repeating units (non-CRUs). MOSAIC performs sequential modular operations using monomer mass differences as base units to compress complex spectral data, revealing end-group distributions and comonomer incorporation. As a demonstration, we applied MOSAIC to five copolymers formed by two different polymerization mechanisms. Furthermore, the resulting remainder–mass plots clearly resolve polymer homologs with distinct non-CRUs into visually apparent clusters, enabling intuitive assignment of mass spectral features.

Wang, Hanlin M. [University of Illinois at Urbana−↗

The 2022 magneto-optics roadmap

Abstract Magneto-optical (MO) effects, viz. magnetically induced changes in light intensity or polarization upon reflection from or transmission through a magnetic sample, were discovered over a century and a half ago. Initially they played a crucially relevant role in unveiling the fundamentals of electromagnetism and quantum mechanics. A more broad-based relevance and wide-spread use of MO methods, however, remained quite limited until the 1960s due to a lack of suitable, reliable and easy-to-operate light sources. The advent of Laser technology and the availability of other novel light sources led to an enormous expansion of MO measurement techniques and applications that continues to this day (see section 1). The here-assembled roadmap article is intended to provide a meaningful survey over many of the most relevant recent developments, advances, and emerging research directions in a rather condensed form, so that readers can easily access a significant overview about this very dynamic research field. While light source technology and other experimental developments were crucial in the establishment of today’s magneto-optics, progress also relies on an ever-increasing theoretical understanding of MO effects from a quantum mechanical perspective (see section 2), as well as using electromagnetic theory and modelling approaches (see section 3) to enable quantitatively reliable predictions for ever more complex materials, metamaterials, and device geometries. The latest advances in established MO methodologies and especially the utilization of the MO Kerr effect (MOKE) are presented in sections 4 (MOKE spectroscopy), 5 (higher order MOKE effects), 6 (MOKE microscopy), 8 (high sensitivity MOKE), 9 (generalized MO ellipsometry), and 20 (Cotton–Mouton effect in two-dimensional materials). In addition, MO effects are now being investigated and utilized in spectral ranges, to which they originally seemed completely foreign, as those of synchrotron radiation x-rays (see section 14 on three-dimensional magnetic characterization and section 16 on light beams carrying orbital angular momentum) and, very recently, the terahertz (THz) regime (see section 18 on THz MOKE and section 19 on THz ellipsometry for electron paramagnetic resonance detection). Magneto-optics also demonstrates its strength in a unique way when combined with femtosecond laser pulses (see section 10 on ultrafast MOKE and section 15 on magneto-optics using x-ray free electron lasers), facilitating the very active field of time-resolved MO spectroscopy that enables investigations of phenomena like spin relaxation of non-equilibrium photoexcited carriers, transient modifications of ferromagnetic order, and photo-induced dynamic phase transitions, to name a few. Recent progress in nanoscience and nanotechnology, which is intimately linked to the achieved impressive ability to reliably fabricate materials and functional structures at the nanoscale, now enables the exploitation of strongly enhanced MO effects induced by light–matter interaction at the nanoscale (see section 12 on magnetoplasmonics and section 13 on MO metasurfaces). MO effects are also at the very heart of powerful magnetic characterization techniques like Brillouin light scattering and time-resolved pump-probe measurements for the study of spin waves (see section 7), their interactions with acoustic waves (see section 11), and ultra-sensitive magnetic field sensing applications based on nitrogen-vacancy centres in diamond (see section 17). Despite our best attempt to represent the field of magneto-optics accurately and do justice to all its novel developments and its diversity, the research area is so extensive and active that there remains great latitude in deciding what to include in an article of this sort, which in turn means that some areas might not be adequately represented here. However, we feel that the 20 sections that form this 2022 magneto-optics roadmap article, each written by experts in the field and addressing a specific subject on only two pages, provide an accurate snapshot of where this research field stands today. Correspondingly, it should act as a valuable reference point and guideline for emerging research directions in modern magneto-optics, as well as illustrate the directions this research field might take in the foreseeable future.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photonic Crystal Surface Emitting GaSb-Based Type-I Quantum Well Diode Lasers

The GaSb-based epitaxially regrown monolithic diode PCSELs operating near 2 μm at room temperature in continuous wave regime and generating 30 mW of output power from 200 μm diameter aperture have been designed and fabricated. Here, the devices demonstrated CW threshold current density of about 500 A/cm 2 . The laser output power was enhanced thanks to increased buried void area fill-factor in the photonic crystal layer with multiple voids per unit cell. The PCSEL generated ultra-low divergence donut shape beams at the currents near threshold. At higher injection currents, the device brightness was limited by excitation of the higher order lateral modes. Generation of the vector-vortex beams of different types by different band edge states of the buried photonic crystal was observed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Additive manufacturing of amorphous metal soft magnetic composites

Soft magnet alloys are used as magnetic cores for electric motors, transformers, wind turbines and other power generation systems. Soft magnetic cores are expensive and time consuming to manufacture in the complex shapes required for next-generation devices using conventional press and sinter powder metallurgy. The objective of this effort is to additively manufacture high performance soft magnets, with reduced cost and reduced material waste and 10x lower energy (core) loss at the high operating frequencies of many electric machines. Laser powder bed fusion additive manufacturing is used as the fabrication method. Electrical steel and amorphous alloys atomized powders are used as a feedstock materials. Magnetic cores are printed in topology optimized structures such as the Hilbert curve because this has been shown to reduce energy losses by minimizing the eddy currents that circulate within the magnet at high frequencies. In our project, we succeed in printing FeSi 3.5wt% and FeSi 6.5wt% electrical steels, and iron-based soft magnetic amorphous alloys in the shape of Hilbert and Peano curve topology optimized structures. We found that the Peano curve has a higher cut-off frequency than the Hilbert curve, and that amorphous alloys have high cut-off frequencies and higher mechanical hardness than electrical steels. Processing conditions such as laser power, scan speed, and hatching pattern were optimized to achieve high density prints, and optimize magnetic performance. We find that the printing of amorphous alloy soft magnetic cores may be technoeconomically feasible for large scale applications such as transformers, for which supply chain issues and the labor costs of manual fabrication of magnetic cores is prohibitive in some cases.

36 MATERIALS SCIENCE↗

Single and Double Shell Ignition Targets for the National Ignition Facility at 527 nm

Converting and using the National Ignition Facility (NIF) to deliver 527 nm light instead of its current 351 nm would allow the laser to deliver more energy and power to ignition targets. We update previous 527 nm target design work to reflect more contemporary target designs using high-density carbon capsules and low density helium gas filled Hohlraums. We extend single shell capsule designs based on current experimental results to higher energy and power and also explore double shell capsules, both driven by green light. These studies were completed using detailed pulse shapes found for targets that converged with acceptable 2D implosion symmetries and then used the Lava Lamp II code to confirm their feasibility at NIF. A 1.2× dimensional scaleup of one tuned NIF target at the limit of its current 351 nm capabilities and shot 170827 uses 3.3 MJ, at the limit of the current NIF's 527 nm capability. With the less-structured pulse of a double shell target, 3.7 MJ could be delivered by the laser. Our LPI calculations do not preclude operation at 527 nm, particularly for low fill Hohlraums, and suggest that the stimulated Raman backscatter may be no worse than the small quantities seen in 170827; stimulated forward Raman scattering may be present. If Stimulated Brillouin Scattering is too great, the much greater laser bandwidth available at 527 nm could be used to decrease backscatter. These larger targets with higher energy and power may offer a better chance of achieving ignition with only modest changes to the NIF laser.

43 PARTICLE ACCELERATORS↗

Removal of Metal Oxides from Reactor Metals/Alloys by Laser Ablation

Storage of low and intermediate level radioactive waste in a deep geological repository (L and ILW DGR): - Large volumes of metallic waste = increased production of hydrogen gas. - Large fraction of the metallic wastes are out-of-core reactor components. - Carbon steel feeder pipes. - Radioactive contamination is concentrated within the surface oxides. - Removal of surface contaminants would lead to volume reduction of metallic waste that is stored in L and ILW DGR. - Current decontamination techniques generate large volumes of secondary waste. Objectives: Oxide removal from carbon steel using a ytterbium fiber laser (1064 nm) with a particular focus on identifying the key laser parameters that affect the removal efficiency. Advantages of laser ablation: Generate low volumes of waste, Flexibility of deployment, Remote operation. Grow an oxide film on carbon steel with the incorporation of cobalt. Optimize laser cleaning technology for the removal of surface oxides. Incorporate an oxide collection system for the ablated particles. Conclusions: Objective 1 - Simulated inactive oxides on carbon steel, using Co{sup 2+} as a surrogate for Co radionuclide. Objective 2 - Optimized laser parameters (200 MW/cm{sup 2}, 3 scans, 15 μm overlap); Complete removal of cobalt from surface and bulk metal with optimized cleaning settings. Objective 3 - Glass fiber media H14 HEPA filters had highest collection yield; High oxide collection yields (∼100%). Future Work: Further testing of the liquid trap will verify the efficacy of the HEPA filter and determine the amount of ablated oxides that pass through. Testing of the laser ablation system needs to be done on other reactor materials along with the incorporation of different transition metal cations. Improvements to the oxide collection system are required to improve collection yields.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Novel Technology of Non-Contact Real-Time Radiation Damage Sensor for High Power Targets

High-power proton beams planned for forthcoming long-baseline neutrino experiments will subject solid targets to unprecedented radiation damage, threatening reliability and increasing costs. To address this challenge, we are building a real-time, non-contact sensor that tracks damage by measuring broadband laser reflectivity changes from the target surface. A low-power super-continuum Class 3B laser illuminates the sample inside a vacuum test chamber while a high-resolution fiber-coupled spectrometer captures S- and P-polarized light; spectral shifts reveal defect-driven variations in optical constants. My internship goal is to design, build, and commission this prototype by implementing a laser-safety interlock and light shield, integrating remote-operation cameras, and fabricating modular 3-D-printed mounts that enable tool-free swaps without disturbing alignment. The laser, spectrometer, and vacuum chamber have been delivered; interlock hardware, cameras, and mounts are in final assembly, and leak testing of the chamber is underway. Upcoming work will focus on initial calibration of the sensor and executing first beam-irradiation studies.

Pumarino, Rafael↗

Optimized matching conditions for self-guided laser wakefield accelerators

We revisit the matching conditions for self-guided laser pulse propagation in plasma and refine their formulation to maximize the energy of electrons produced via laser wakefield acceleration. Bayesian optimization, combined with particle-in-cell simulations carried out in a quasi-three-dimensional geometry and a Lorentz-boosted frame, is employed. The optimization identifies the maximum electron energy that a self-guided laser wakefield accelerator, driven by a laser of a given energy, can produce, together with the corresponding acceleration distance. Our results further demonstrate that electrons with energies close to the maximum value can be obtained across a relatively wide range of input parameters and without the need for their precise tuning. This provides substantial flexibility for experimental implementation and significantly relaxes the operational constraints associated with self-guided laser wakefield accelerators.

43 PARTICLE ACCELERATORS↗