Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Towards Portable Laser Desorption Postionization Mass Spectrometry Utilizing Microchip Laser Pulses

A 355 nm, 1.5 ns, up to 1 kHz microchip laser system has been tested to both yield ablation spots and postionize material within a plasma plume. A 30 µJ pulse energy microchip laser successfully ablated all samples: 6601 aluminum, 316 and 304 stainless steel, and Mo metal. While visible ablation craters were observed on all samples mentioned above, the stainless-steel samples displayed visible color changes in the resolidified iron, indicating ionization with the 355 nm pulses during ablation. Additionally, when used to intercept a plasma plume of Cs 2 CO 3 made with a separate laser system, the microchip laser pulses yielded Cs + emission signal otherwise not observed. With these experiments completed, the microchip laser has been successfully verified for readiness to be integrated into the front end of a mass spectrometer system as the ion source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

National User Resource for Biological Accelerator Mass Spectrometry (Final Report)

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH- funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool. The User Resource’s forte will be ultra-high sensitivity quantitation of radiocarbon and selected other radioisotopes for research studies where isotopes are required. Radioisotope labeling studies have been and will continue to be an important tool for addressing many complex biomedical science problems. AMS is a specialized and unique type of mass spectrometry that provides absolute quantitation of radiocarbon and other relevant radioisotopes with extreme sensitivity, having limits of detection in real samples on the order of a few attomol/mg of sample at measurement precisions of ~3%. It is the only instrumental method capable of quantifying radioisotope-labeled agents routinely in real-world samples with such precision and sensitivity. The sensitivity of AMS allows for the quantification of radiolabeled metabolites in extremely complex matrices of cells and organisms at very low concentrations and in small samples. AMS allows studies to be conducted without perturbing metabolism leading to more relevant quantification of metabolic rates and pathways. In addition, it enables quantification of pharmacokinetic and metabolic properties of toxicants at environmentally relevant concentrations in model systems as well as the ability to quantify pharmacokinetics and other molecular endpoints directly in humans. Such quantitative assessments can 1) improve risk assessment for toxicants, 2) address safety and efficacy considerations for therapeutic entities, 3) deepen understanding of xenobiotic and intermediary metabolism, 4) help understand the interactions between critical molecular pathways, and 5) improve efforts to model and predict various metabolic and biological states. These capabilities have been applied in a number of areas including research in carcinogenesis, toxicology, nutrition, pharmacology/drug development and basic biological science. As a NIGMS National Resource the National User Resource for Biological Accelerator Mass Spectrometry will help NIH funded scientists achieve a deeper understanding of the etiology of human health concerns by (1) enabling the quantification of pharmacokinetics and other molecular endpoints directly in humans; (2) offering the ability to conduct quantitative studies using biologics such as proteins or lipids, and thereby reducing the amount of radioisotope usage in biomedical labs; and (3) enabling more relevant studies of metabolic pathways in health and disease through the use of much lower, more biologically-relevant, concentrations of metabolic substrates in cells and intact organisms. Such studies support NIGMS’s basic biomedical research areas that contribute to the understanding of fundamental cellular and physiological principles and enable research supported by the Biophysics, Biomedical Technology, and Computational Biosciences (BBCB); Genetics and Molecular, Cellular, and Developmental Biology (GMCDB); Pharmacology, Physiology, Biological Chemistry (PPBC) and Training, Workforce Development, and Diversity (TWD) Divisions. Over the next five years, our goals are to: 1. Improve the efficiency of operation for AMS measurements through installation of new interfaces to our AMS systems, technical modifications to improve gas accepting ion source efficiency and upgrading our data analysis software for improved ease of use and data reporting. 2. Increase the accessibility and visibility of ultra-sensitive 14C measurements for the biomedical research community by training of new investigators and expanding our national user base. 3. Provide high throughput, ultra-sensitive 14C analysis for the NIGMS and NIH user community.

47 OTHER INSTRUMENTATION↗

Warm Front End Upgrade for the PIP-II Linac

The warm front end for the PIP-II Linac consists of an Ion-source, an RFQ, and four buncher cavities. The LLRF systems for these were the first ones developed more than a decade ago for use at the test stands. Some were VXI crate based, and others used early generation FPGA boards that are light in resources. These LLRF systems and the one for the first superconducting cryomodule, the HWR will be upgraded with the ARRIA 10 SOC-FPGA chassis with EPICS interfaces like the rest of the PIP-II Linac. The RFQ and the HWR have unique resonance control systems which are integrated into the LLRF controller hardware. The results of the initial testing with a cavity emulator will be presented.

Reyes, Lennon [Fermilab] (ORCID:0009000891155652)↗

Configuration Management Plan

The Los Alamos Neutron Science Center (LANSCE) is located at Technical Area 53 (TA-53) at Los Alamos National Laboratory (LANL) in Los Alamos, New Mexico. LANSCE is driven by an 800 megaelectronvolt (MeV) proton accelerator that delivered its first beam in 1972. The LANSCE accelerator is unique in that it accelerates both H– (to full energy of 800 MeV) and H+ ions (up to 100 MeV currently but has accelerated high-power H+ beam to 800 MeV in the past) and supports five separate experimental areas that operate simultaneously, with each having different timing and beam current requirements. Many of the LANSCE accelerator front-end components date back to original commissioning in 1972, including the ion sources, Cockcroft-Walton (CW) generators, and the Drift Tube LINAC (DTL), which accelerates the beam up to 100 MeV.

43 PARTICLE ACCELERATORS↗

A High-Field Polarized 3 He Target for Jefferson Lab’s CLAS12 Spectrometer

Polarized 3He nuclear targets are invaluable surrogates for polarized neutron targets in spin-dependent scattering studies of the structure of matter. Traditional polarized 3He targets have seen steady improvements and active use over the last three decades, however they have been limited to operation in low magnetic fields. This has precluded their use in spectrometers that utilize high-magnetic-field tracking systems, such as Jefferson Lab's CLAS12 spectrometer. Developments in high-magnetic-field metastability exchange optical pumping of 3He, recently incorporated into the design of a polarized 3He ion source for RHIC and the EIC, could enable a new, polarized 3He fixed target to operate within high fields. Combining high-field techniques with the double-cell cryogenic target design used for the MIT-Bates 88-02 experiment, polarization and target density comparable to traditional polarized 3He targets could be reached while within a high magnetic field environment. We discuss the conceptual design for such a target, show our progress in this target's development, and outline plans for in-beams tests in Jefferson Lab's Hall B.

Maxwell, James↗

NIBS 2020 Reference Sheets

In preparation for NIBS 2020 various labs prepared reference sheets containing key information about their ion sources and the machines that they serve. The contents of the reference sheets have been formatted and edited into this paper for posterity and ease of access.

Welton, Robert F.↗

Compact high gradient ion accelerating structure

A high gradient linear accelerating structure can propagate high frequency waves at a negative harmonic to accelerate low-energy ions. The linear accelerating structure can provide a gradient of 50 MV/m for particles at a β of between 0.3 and 0.4. The high gradient structure can be a part of a linear accelerator configured to provide an energy range from an ion source to 450 MeV/u for 12 C 6+ and 250 MeV for protons. The linear accelerator can include one or more of the following sections: a radiofrequency quadrupole (RFQ) accelerator operating at the sub-harmonic of the S-band frequency, a high gradient structure for the energy range from ˜45 MeV/u to ˜450 MeV/u.

Kutsaev, Sergey↗

Time-drift Aware RF Optimization with Machine Learning Techniques

The Fermilab Linac delivers 400 MeV H- beam to the rest of the accelerator chain. Providing stable intensity, energy, and emittance is key since it directly affects downstream machines. To operate high current beam, accelerators must minimize uncontrolled particle loss; this can be accomplished by minimizing beam longitudinal emittance via RF parameter optimization. However, RF tuning is required daily since the resonance frequency of the accelerating cavities is affected by ambient temperature and humidity variations and thus drifts with time. In addition, the energy and phase space distribution of particles emerging from the ion source are subject to fluctuations. Such drift is not unique to Fermilab, but rather affects most laboratories. We are exploring machine learning (ML) algorithms for automated RF tuning for 2 objectives: optimization of Linac output energy and phase oscillation correction, with an emphasis on time-drift aware modeling that can account for conditions changing over time.

43 PARTICLE ACCELERATORS↗

LLRF System for the Fermilab PIP-II Superconducting LINAC

PIP-II is an 800 MEV superconducting linac that is in the initial acceleration chain for the Fermilab accelerator complex. The RF system consists of a warm front-end with an ion source, RFQ and buncher cavities along with 25 superconducting cryo-modules comprised of five different acceleration \(\beta\). The LLRF system for the LINAC has to provide field and resonance control for a total of 125 RF cavities.The LLRF system design is in the final design review phase and will enter the production phase next year. The PIP-II project is an international collaboration with various partner labs contributing subsystems. The LLRF system design for the PIP-II Linac is presented and the specification requirements and system performance in various stages of testing are described in this paper.

43 PARTICLE ACCELERATORS↗

A compact dication source for Ba 2+ tagging and heavy metal ion sensor development

Here, we present a tunable metal ion beam that delivers controllable ion currents in the picoamp range for testing of dry-phase ion sensors. Ion beams are formed by sequential atomic evaporation and single or multiple electron impact ionization, followed by acceleration into a sensing region. Controllability of the ionic charge state is achieved through tuning of electrode potentials that influence the retention time in the ionization region. Barium, lead, and cadmium samples have been used to test the system, with ion currents identified and quantified using a quadrupole mass analyzer. Realization of a clean Ba 2+ ion beam within a bench-top system represents an important technical advance toward the development and characterization of barium tagging systems for neutrinoless double beta decay searches in xenon gas. This system also provides a testbed for investigation of novel ion sensing methodologies for environmental assay applications, with dication beams of Pb 2+ and Cd 2+ also demonstrated for this purpose.

47 OTHER INSTRUMENTATION↗

Characterization of Gas Bremsstrahlung sources at the Electron-Ion Collider

This report estimates the potential impact of Gas Bremsstrahlung, generated as the electron beam traverses the straight sections of the storage ring and impinges onto selected locations of the Electron-Ion Collider. The source terms were calculated for routine operation scenarios at three different energies: 5, 10 and 18 GeV, using the FLUKA Monte Carlo particle transport and interaction code. The source term’s power distributions were validated and compared with the Gas Bremsstrahlung produced in the long straight sections of the National Synchrotron Light Source II storage ring.

43 PARTICLE ACCELERATORS↗

Atomistic simulations for investigation of substrate effects on lipid in-source fragmentation in secondary ion mass spectrometry

In beam-based ionization methods, the substrate plays an important role on the desorption mechanism of molecules from surfaces. Both the specific orientation that a molecule adopts at a surface and the strength of the molecule-surface interaction can greatly influence desorption processes, which in turn will affect the ion yield and the degree of in-source fragmentation of a molecule. In the beam-based method of secondary ion mass spectrometry (SIMS), in-source fragmentation can be significant and molecule specific due to the hard ionization method of using a primary ion beam for molecule desorption. To investigate the role of the substrate on orientation and in-source fragmentation, we have used atomistic simulations—molecular dynamics in combination with density functional theory calculations—to explore the desorption of a sphingolipid (palmitoylsphingomyelin) from a model surface (gold). We then compare SIMS data from this model system to our modeling findings. Using this approach, we found that the combined adsorption and binding energy of certain bonds associated with the headgroup fragments (C3H8N+, C5H12N+, C5H14NO+, and C5H15PNO4+) was a good predictor for fragment intensities (as indicated by relative ion yields). This is the first example where atomistic simulations have been applied in beam-based ionization of lipids, and it presents a new approach to study biointerfacial lipid ordering effects on SIMS imaging.

59 BASIC BIOLOGICAL SCIENCES↗

Atomistic simulations for investigation of substrate and salt effects on lipid in-source fragmentation in secondary ion mass spectrometry: A follow-up study

In-source fragmentation (ISF) poses a significant challenge in secondary ion mass spectrometry (SIMS). These fragment ions increase the spectral complexity and can lead to incorrect annotation of fragments as intact species. The presence of salt that is ubiquitous in biological samples can influence the fragmentation and ionization of analytes in a significant manner, but their influences on SIMS have not been well characterized. To elucidate the effect of substrates and salt on ISF in SIMS, we have employed experimental SIMS in combination with atomistic simulations of a sphingolipid on a gold surface with various NaCl concentrations as a model system. Our results revealed that a combination of bond dissociation energy and binding energy between N-palmitoyl-sphingomyelin and a gold surface is a good predictor of fragment ion intensities in the absence of salt. However, ion-fragment interactions play a significant role in determining fragment yields in the presence of salt. Additionally, the charge distribution on fragment species may be a major contributor to the varying effects of salt on fragmentation. This study demonstrates that atomistic modeling can help predict ionization potential when salts are present, providing insights for more accurate interpretations of complex biological spectra.

74 ATOMIC AND MOLECULAR PHYSICS↗

Pair momentum dependence of a tilted source in heavy-ion collisions

In noncentral heavy-ion collisions, the particle-emitting source can be tilted away from the beam direction, an effect that becomes particularly significant at collision energies of a few GeV and lower. This phenomenon, manifest itself in many observables such as directed flow, polarization, and vorticity, is therefore important to investigate. Here, in this paper, we study the consistency between the tilt extracted directly from the freeze-out distribution of pions and the tilt parameter obtained using the azimuthally sensitive femtoscopy (asHBT) method. Using the Ultrarelativistic Quantum Molecular Dynamics model, we demonstrate a strong dependence of the tilt parameter extracted with asHBT on the momentum of the particle pair. Considering the experimental challenges in accessing low particle momenta—where the tilt parameter extracted with asHBT closely matches the tilt of the freeze-out distribution of pions—we propose an exponential extrapolation method to obtain the tilt of the entire freeze-out distribution. This approach aims to enhance the accuracy of experimental measurements of tilt in noncentral heavy-ion collisions.

particle correlations & fluctuations↗

Conceptual Design and Analysis of In-Vessel Components for the Materials Plasma Exposure eXperiment (MPEX)

The materials plasma exposure experiment (MPEX) is a linear plasma divertor simulator currently undergoing conceptual design. The facility will expose material samples to steady-state plasma fluxes to examine plasma–material interactions (PMIs) that are expected in the next generation of fusion devices. The plasmas will be generated by a helicon source, with electron and ion heating sources of up to 800 kW possible. The peak heat fluxes of the target are expected to be up to 10 MW/m 2 . The facility will be capable of handling low-activation neutron-irradiated samples in order to examine the multivariate effects of neutron damage and plasma fluence. Neutron-irradiated samples are planned to be roughly of 10-mm diameter; however, plasma-facing components up to 60×600 mm can be accommodated. The steady-state nature of the device will require the magnetic confinement of the plasma to be achieved with superconducting magnets, with a maximum on-axis field of 2.5 T. In addition, since MPEX will be a steady-state device, in-vessel components need to be water cooled. The primary in-vessel components will be the target, the dump plate, the limiter, the skimmers, and the microwave absorber. The conceptual design of these components is presented here, including analyses that confirm that the designs are adequate to meet the requirements of MPEX operation.

Lumsdaine, Arnold↗

Ion Clusters Reveal the Sources, Impacts, and Drivers of Freshwater Salinization

Population growth, land use change, climate change, and natural resource extraction are driving the salinization of freshwater resources worldwide. Reversing these trends will require data-centric approaches that identify salt sources, environmental drivers, and ecosystem responses. In this study, we applied principal component analysis and hierarchical clustering to identify ion covariance patterns, or “ion clusters,” in Broad Run, an urban stream in the Mid-Atlantic United States. These clusters correspond to distinct hydrologic regimes and reveal specific salinization risks: (1) phosphorus pollution mobilized during summer storms (Cluster 1); (2) elevated concentrations of sulfate and bicarbonate during baseflow (Cluster 2), likely reflecting groundwater discharge; and (3) elevated specific conductance and sodium, chloride, and potassium ion concentrations during snowmelt and rain-on-snow events (Cluster 3), driven by deicer and anti-icer wash-off. These ion fingerprints offer a transferable framework for diagnosing salt sources, assessing ecological risk, and identifying management targets. Our findings underscore the need for next-generation stormwater infrastructure and smart growth policies to protect aquatic life in rapidly urbanizing watersheds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of δ 13 C analyses of individual foraminifer ( Orbulina universa ) shells by secondary ion mass spectrometry and gas source mass spectrometry

Rationale: The use of secondary ion mass spectrometry (SIMS) to perform micrometer-scale in situ carbon isotope (δ 13 C) analyses of shells of marine microfossils called planktic foraminifers holds promise to explore calcification and ecological processes. The potential of this technique, however, cannot be realized without comparison to traditional whole-shell δ 13 C values measured by gas source mass spectrometry (GSMS). Methods: Paired SIMS and GSMS δ 13 C values measured from final chamber fragments of the same shell of the planktic foraminifer Orbulina universa are compared. The SIMS–GSMS δ 13 C differences (Δ 13 C SIMS-GSMS ) were determined via paired analysis of hydrogen peroxide-cleaned fragments of modern cultured specimens and of fossil specimens from deep-sea sediments that were either untreated, sonicated, and cleaned with hydrogen peroxide or vacuum roasted. After treatment, fragments were analyzed by a CAMECA IMS 1280 SIMS instrument and either a ThermoScientific MAT-253 or a Fisons Optima isotope ratio mass spectrometer (GSMS). Results: Paired analyses of cleaned fragments of cultured specimens (n = 7) yield no SIMS–GSMS δ 13 C difference. However, paired analyses of untreated (n = 18) and cleaned (n = 12) fragments of fossil shells yield average Δ 13 C SIMS-GSMS values of 0.8‰ and 0.6‰ (±0.2‰, 2 SE), respectively, while vacuum roasting of fossil shell fragments (n = 11) removes the SIMS–GSMS δ 13 C difference. Conclusions: The noted Δ 13 C SIMS-GSMS values are most likely due to matrix effects causing sample–standard mismatch for SIMS analyses but may also be a combination of other factors such as SIMS measurement of chemically bound water. The volume of material analyzed via SIMS is ~10 5 times smaller than that analyzed by GSMS; hence, the extent to which these Δ 13 C SIMS-GSMS values represent differences in analyte or instrument factors remains unclear.

58 GEOSCIENCES↗

Simulations of ion heating due to ion-acoustic instabilities in presheaths

Particle-in-cell, direct simulation Monte Carlo simulations reveal that ion-acoustic instabilities excited in presheaths can cause significant ion heating. Ion-acoustic instabilities are excited by the ion flow toward a sheath when the neutral gas pressure is small enough and the electron temperature is large enough. A series of 1D simulations were conducted in which neutral plasma (electrons and ions) was uniformly sourced with an ion temperature of 0.026 eV and different electron temperatures (0.1 eV–50 eV). Ion heating was observed when the electron-to-ion temperature ratio exceeded the minimum value predicted by linear response theory to excite ion-acoustic instabilities at the sheath edge (T e /T i ≈ 28). When this threshold was exceeded, the temperature equilibration rate between ions and electrons rapidly increased near the sheath so that the local temperature ratio did not significantly exceed the threshold for instability. This resulted in significant ion heating near the sheath edge, which also extended back into the bulk plasma; presumably due to wave reflection from the sheath. Furthermore, this ion-acoustic wave heating mechanism was found to decrease for higher neutral pressures, where ion-neutral collisions damp the ion-acoustic waves and ion heating is instead dominated by inelastic collisions in the presheath.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗