Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion mobility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Synthetic Accessibility and Sodium Ion Conductivity of the Na8–x A x P2O9 (NAP) High-Temperature Sodium Superionic Conductor Framework

Advancement of solid-state electrolytes (SSEs) for all solid-state batteries typically focuses on modification of a known structural framework to improve conductivity, e.g., cation substitution for an immobile ion or varying the concentration of the mobile ions. Novel frameworks can be disruptive by enabling fast ion conduction aided by different structure and diffusion mechanisms, thereby unlocking optimal conductors with different properties. Herein, we perform a high-throughput survey of a structural framework for sodium ion conduction, Na8–x A x P2O9 (NAP), to understand the family’s thermodynamic stability, synthesizability, and ionic conduction. We show that the parent phase Na4TiP2O9 (NTP) undergoes a structural distortion (with accompanying conductivity transition) due to unstable phonons arising from pseudo-Jahn–Teller mode in the 1D titanium chains. Screening compounds in which Ti is substituted by other metals computationally reveal a number of candidates that are predicted to be low in formation energy and have high predicted ionic conductivities. High-throughput experimental and subsequent methodology optimization trials deliver one new compound, Na4SnP2O9 (NSP). X-ray diffraction (XRD), microscopy, and spectroscopy characterization indicate that the room-temperature structure of NSP is similar to the high-temperature, orthorhombic NTP phase but with some small unresolved structural differences. These uncharacterized structural details are speculated to limit the ion conductivity. Temperature-dependent XRD and electrochemical impedance spectroscopy indicate multiple coupled conductivity–structure transitions at a high temperature. We demonstrate the challenges with synthesis development and a priori identification of promising SSE phases as a major bottleneck in new (energy) materials development.

Chemical reactions↗

Evaluating Ion Accumulation and Storage in Traveling Wave Based Structures for Lossless Ion Manipulations

Structures for lossless ion manipulations (SLIM) technology has demonstrated high resolving power ion mobility separation and flexibility to integrate complex ion manipulations into a single experimental platform. To enable IMS separations, trapping/accumulating ions inside SLIM (or in-SLIM) prior to injection of a packet for separations provides ease of operation and reduces the need for dedicated ion traps external to SLIM. To fully characterize the ion accumulation process, we have evaluated the effect of TW amplitudes, ion collection times, and storage times on the “in-SLIM” accumulation process. The study utilized a SLIM module comprising 5 distinct tracks, each with a specific ion accumulation configuration. The effect of the TW conditions on the accumulation process was investigated for a 3-peptide mixture: kemptide, angiotensin II, and neurotensin at a TW speed of 106 m/s. The effect of ion accumulation time/collection time and storage time was investigated, in addition to TW amplitude. Overall, the signal of the analyte ions increased when the ion collection time increased from 49 to 163 ms but decreased when the ion collection time increased further to 652 ms due to the space charge effects. Ion losses were observed at high TW amplitudes (e.g., 15 V p–p and 20 V p–p ). In addition, under space charge conditions (e.g., collection times of 163 and 652 ms), the signal of the analyte ions decreased with an increase in storage times for all TW amplitudes applied to the trapping region. For ion accumulation, the data indicate that gentler TW conditions must be utilized to minimize ion losses and fragments to benefit from the “in-SLIM” accumulation process. Finally, wider SLIM tracks provided better performance than those with narrower tracks.

59 BASIC BIOLOGICAL SCIENCES↗

Middle atmosphere electrical structure during MAC/EPSILON

Extensive use of rocket-launched probes during the the MAC/EPSILON campaign at the Andoya Rocket Range, Norway, has enabled the characterization of the region's electrical environment for all four flight series. The first rocket salvo was conducted during daylight (October 15, 1987) and the subsequent three occurred at night (October 21 and 28 and November 12, 1987), all of them during geomagnetically disturbed conditions. Measurements of polar electrical conductivity, ion mobility, and number density are presented, and their associated structure is investigated for local auroral ionization effects. This is believed to be the first time that Gerdien condenser mobility measurements have indicated a heavy-ion presence (positively charged aerosols) in the auroral mesopause region.

Mitchell, J. D.↗

Exploring new frontiers in type 1 diabetes through advanced mass-spectrometry-based molecular measurements

Type 1 diabetes (T1D) is a devastating autoimmune disease for which advanced mass spectrometry (MS) methods are increasingly used to identify new biomarkers and better understand underlying mechanisms. For example, integration of MS analysis and machine learning has identified multimolecular biomarker panels. In mechanistic studies, MS has contributed to the discovery of neoepitopes, and pathways involved in disease development and identifying therapeutic targets. However, challenges remain in understanding the role of tissue microenvironments, spatial heterogeneity, and environmental factors in disease pathogenesis. Recent advancements in MS, such as ultra-fast ion-mobility separations, and single-cell and spatial omics, can play a central role in addressing these challenges. Here, in this work, we review recent advancements in MS-based molecular measurements and their role in understanding T1D.

60 APPLIED LIFE SCIENCES↗

Transport coefficients of gaseous ions in an electric field

A general theory of ion mobility formulated by Kihara (1953) is extended to ion diffusion and to mixtures of neutral gases. The theory assumes that only binary collisions between ions and neutral particles need to be taken into account and that the velocity distribution function of the neutral particles is Maxwellian. These assumptions make it possible to use a linearized Boltzmann equation. Questions of mobility are considered along with aspects of diffusion and deviations from Fick's law of diffusion.

Whealton, J. H.↗

Ambient Ion Trapping and Separations for High Throughput Structurally Selective Material Deposition

While ion mobility coupled to mass spectrometry (IMS/MS) has been increasingly adapted to biological analysis, the structural and molecular specificity offered by IMS/MS has untapped potential for creating novel materials (for energy, catalysis, biomolecular switches etc.) with rationally tailored properties by precisely controlling the chemical structure and composition of these materials. While electrochemical and catalytic properties of the bulk material are understood by mass-selective ion-soft-landing, different structures of one molecule can exhibit distinct properties from the bulk. Many biological phenomenon occur at interfaces and are highly structurally specific. IMS/MS offers means to separate molecules in a sample (which is first ionized and released to gas phase from the condensed phase) based on mass and structure. Species thus separated can potentially be deposited onto surfaces with molecular and structural specificity, to perform fundamental investigations for understanding critical interfacial phenomenon. Key performance metrics for IMS/MS analysis are resolution of separations and sensitivity. Recently developed Structures for Lossless Ion Manipulations (SLIM)4 enabled unprecedented resolution in IMS separations. In addition, high sensitivity was enabled in SLIM due to lossless confinement of ions using radio frequency fields. Thus, SLIM enabled extremely long path length separations (up to 0.1 km thus far) providing efficient separation of molecular ions never before achieved (e.g. isotopologues, D&L amino acids). While SLIM has unprecedented analytical separations power/utility, the use of SLIM platform for depositing mobility and mass selected molecular ions has two specific technological challenges: (a) Pulsed nature of IMS separations and their low duty cycle and (b) the need for a low vacuum of ~4 torr for lossless ion confinement. These limitations lead to long deposition times due to loss of ions generated from the sample. Enabling ion confinement at atmospheric pressure will be path-breaking contribution to the fundamental understanding of ion manipulations and separations and will also enable novel science currently precluded due to the inability of the present technologies to confine ions under ambient conditions. Traditionally used radio frequency fields are ineffective in confining ions at high pressures due to ion/neutral collisions. To address these, we propose to (a) develop methods for confining and manipulating ions for lossless IMS separations at atmospheric pressure enabling high sensitivity and throughput and (b) use the high specificity of IMS/MS and high throughput from ambient ion confinement to perform mobility and mass selective ion deposition at atmospheric pressure. Our goal is to enable the study of the fundamental properties of energy/catalysis materials and biomolecules. This project paves the way for high-throughput, mass and structure selective material deposition for highly specific surface creation/functionalization (discussed in Section 2 of the report). Further, the developments reported continue to push the boundaries of this process to ambient conditions (discussed in Section 3 of the report). We conclude with a list of specific intellectual property and publications which have been the outcome of this funded project.

36 MATERIALS SCIENCE↗

PeakQC: A Software Tool for Omics-Agnostic Automated Quality Control of Mass Spectrometry Data

Mass spectrometry is broadly employed to study complex molecular mechanisms in various biological and environmental fields, enabling 'omics' research such as proteomics, metabolomics, and lipidomics. As study cohorts grow larger and more complex with dozens to hundreds of samples, the need for robust quality control (QC) measures through automated software tools becomes paramount to ensure the integrity, high quality, and validity of scientific conclusions from downstream analyses and minimize the waste of resources. Since existing QC tools are mostly dedicated to proteomics, automated solutions supporting metabolomics are needed. To address this need, we developed the software PeakQC, a tool for automated QC of MS data that is independent of omics molecular types (i.e., omics-agnostic). It allows automated extraction and inspection of peak metrics of precursor ions (e.g., errors in mass, retention time, arrival time) and supports various instrumentations and acquisition types, from infusion experiments or using liquid chromatography and/or ion mobility spectrometry front-end separations and with/without fragmentation spectra from data-dependent or independent acquisition analyses. Diagnostic plots for fragmentation spectra are also generated. Here, in this paper, we describe and illustrate PeakQC’s functionalities using different representative data sets, demonstrating its utility as a valuable tool for enhancing the quality and reliability of omics mass spectrometry analyses.

47 OTHER INSTRUMENTATION↗

PeakDecoder enables machine learning-based metabolite annotation and accurate profiling in multidimensional mass spectrometry measurements

Multidimensional measurements using state-of-the-art separations and mass spectrometry provide advantages in untargeted metabolomics analyses for studying biological and environmental bio-chemical processes. However, the lack of rapid analytical methods and robust algorithms for these heterogeneous data has limited its application. Here, we develop and evaluate a sensitive and high-throughput analytical and computational workflow to enable accurate metabolite profiling. Our workflow combines liquid chromatography, ion mobility spectrometry and data-independent acquisition mass spectrometry with PeakDecoder, a machine learning-based algorithm that learns to distinguish true co-elution and co-mobility from raw data and calculates metabolite identification error rates. We apply PeakDecoder for metabolite profiling of various engineered strains of Aspergillus pseudoterreus, Aspergillus niger, Pseudomonas putida and Rhodosporidium toruloides. Results, validated manually and against selected reaction monitoring and gas-chromatography platforms, show that 2683 features could be confidently annotated and quantified across 116 microbial sample runs using a library built from 64 standards.

59 BASIC BIOLOGICAL SCIENCES↗

Apolipoprotein A-I modulates HDL particle size in the absence of apolipoprotein A-II

Human high-density lipoproteins (HDLs) are a complex mixture of structurally related nanoparticles that perform distinct physiological functions. We previously showed that human HDL containing apolipoprotein A-I (APOA1) but not apolipoprotein A-II (APOA2), designated LpA-I, is composed primarily of two discretely sized populations. Here, we isolated these particles directly from human plasma by antibody affinity chromatography, separated them by high-resolution size-exclusion chromatography and performed a deep molecular characterization of each species. The large and small LpA-I populations were spherical with mean diameters of 109 Å and 91 Å, respectively. Unexpectedly, isotope dilution MS/MS with [ 15 N]-APOA1 in concert with quantitation of particle concentration by calibrated ion mobility analysis demonstrated that the large particles contained fewer APOA1 molecules than the small particles; the stoichiometries were 3.0 and 3.7 molecules of APOA1 per particle, respectively. MS/MS experiments showed that the protein cargo of large LpA-I particles was more diverse. Human HDL and isolated particles containing both APOA1 and APOA2 exhibit a much wider range and variation of particle sizes than LpA-I, indicating that APOA2 is likely the major contributor to HDL size heterogeneity. We propose a ratchet model based on the trefoil structure of APOA1 whereby the helical cage maintaining particle structure has two “settings”—large and small—that accounts for these findings. This understanding of the determinants of HDL particle size and protein cargo distribution serves as a basis for determining the roles of HDL subpopulations in metabolism and disease states.

59 BASIC BIOLOGICAL SCIENCES↗

Strongly Correlated Ion Dynamics in Plastic Ionic Crystals and Polymerized Ionic Liquids

Understanding the mechanisms controlling ionic conductivity is critical for the development of the next generation of batteries and supercapacitors. This paper discusses the significant role played by ionic correlations in conductivity of concentrated ionic systems. Our studies of an organic ionic plastic crystal reveal that correlations in ions dynamics suppress conductivity by 25–100 times in comparison to the expected uncorrelated ionic conductivity estimated from the Nernst–Einstein relationship. Furthermore, additional analysis also demonstrates that ionic correlations suppress conductivity in polymerized ionic liquids and gel by ~10 times. Thus, ionic correlations, usually neglected in many studies, play a very important role in conductivity of concentrated ionic systems. These results cannot be explained by a diffusion of ion pairs because all these systems are essentially single ion conductors. In contrast, strongly correlated motions of mobile ions with the same charge (cation–cation or anion–anion correlations) are the major mechanism suppressing the ionic conductivity in these systems. Finally, on the basis of these results, we emphasize that charge transport rather than ion diffusion is critical for electrolyte performance and suggest the potential design of plastic crystals and polymer electrolytes with enhanced ionic conductivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Refining PeakDecoder Version 2

Novel computational tools for processing multidimensional mass spectrometry (MS) data are necessary to enable deeper and automated detection and quantification of metabolites in complex backgrounds. Multidimensional MS data includes measurements from liquid chromatography (LC) and ion mobility spectrometry (IM) separations, and precursor and fragment ion spectra collected in data-independent acquisition (DIA) mode. PeakDecoder is an artificial intelligence (AI)-based software that enables automated interpretation of this kind of data to identify and quantify individual metabolites in complex mixtures. The goal of this project was to improve and re-implement PeakDecoder in a better suited programming language to enable its commercialization.

97 MATHEMATICS AND COMPUTING↗

Gas chromatography/ion mobility spectrometry as a hyphenated technique for improved explosives detection and analysis

Ion Mobility Spectrometry (IMS) is currently being successfully applied to the problem of on-line trace detection of plastic and other explosives in airports and other facilities. The methods of sample retrieval primarily consist of batch sampling for particulate residue on a filter card for introduction into the IMS. The sample is desorbed into the IMS using air as the carrier and negative ions of the explosives are detected, some as an adduct with a reagent ion such as Cl(-). Based on studies and tests conducted by different airport authorities, this method seems to work well for low vapor pressure explosives such as RDX and PETN, as well as TNT that are highly adsorptive and can be found in nanogram quantities on contaminated surfaces. Recently, the changing terrorist threat and the adoption of new marking agents for plastic explosives has meant that the sample introduction and analysis capabilities of the IMS must be enhanced in order to keep up with other detector developments. The IMS has sufficient analytical resolution for a few threat compounds but the IMS Plasmogram becomes increasingly more difficult to interpret when the sample mixture gets more complex.

Mercado, AL↗

Field-Domain Ion Spectrometry

Field-domain ion spectrometry (FDIS) is variant of established technique known as ion-mobility spectrometry. Operates at atmospheric pressure and only requires small pump to draw air sample into instrument. Strength of retarding electric field varied to distinguish among ions of different mobilities. New concept offers potential for development of small, (hand-held), low-power, portable devices detecting airborne chemical substances in real-time at concentrations at parts-per-billion level.

Bowers, W. D.↗

What is the Role of Relative Humidity on Conductivity in Polymer Electrolytes?

Ion transport properties in polymer electrolytes have been widely studied under rigorously dry and highly water-swollen conditions. However, the transition between these extremes, i.e., the low hydration regime, is still poorly understood at the molecular level and relevant to applications ranging from battery electrolytes to electrophoretic separations. Here, in this study, we apply atomistic molecular dynamics simulations to probe the role of hydration on ion mobilities and conductivities in LiTFSI-doped polyethers at low water content (less than 10% water by volume), which corresponds to 0−80% relative humidity conditions. With increasing water content, Li + ions exhibit two distinct regimes in their mobilities. At low water content, the majority of the Li + ions are weakly hydrated (two or fewer water molecules per Li + ion), maintaining strong interactions with their polymer solvation cage, and therefore exhibit only a weak increase in mobility relative to dry conditions. As water content increases, Li + ions form complete hydration shells, residing within water-rich domains that promote faster mobilities. Further, Li + mobilities increase more significantly in polymer electrolytes composed of more hydrophilic polymers and higher salt concentrations due to the formation of larger water-rich domains. In contrast, TFSI − has comparatively weak interactions with both the polymer and water, exhibiting a monotonic increase in mobility as a function of water content. Overall, these results help clarify the molecular mechanisms underlying ionic mobilities and conductivities in polymer electrolytes at low water content.

36 MATERIALS SCIENCE↗

Molecular understanding of ion transport in a zwitterionic electrolyte

Zwitterions (ZIs) are unique molecules that carry both positive and negative charges, resulting in overall charge neutrality and high dielectric constants. These distinctive properties have enabled broad applications of zwitterionic functionality, including the emerging use of ZIs in lithium-ion battery electrolytes. As a contribution to this developing field, we use all-atom molecular dynamics simulations to investigate the ion transport mechanisms in amorphous mixtures of a zwitterionic liquid containing a range of LiTFSI salt concentrations. Furthermore, the local coordination environment around the Li + ions plays a strong role in governing ionic conductivity, as well as the enhancement of Li + transport numbers with increasing salt concentration. Addition of small amounts of water leads to increased conductivity and ion mobilities due to the water coordinating with the Li + ions, which reduces direct interactions with larger charged species.

Classical molecular dynamic simulations↗

Light induced ion migration studies in perovskite solar cell using nonlinear impedance spectroscopy

Complex interactions between mobile ions and charge carriers in perovskite solar cells (PSCs) make it challenging to fully understand their dynamic interplay. Exposure to light further complicates these interactions, altering the system’s dynamics and inducing nonlinear effects that lead to changes in the J−V curve. Understanding these effects is crucial for improving the operational stability of PSCs. Impedance spectroscopy (IS) is a powerful technique for evaluating relaxation processes in the frequency domain; however, it is limited in capturing nonlinear contributions. Here, in this work, nonlinear impedance spectroscopy (NLIS) is employed to analyze the higher harmonic response to AC perturbation, both in the dark and after short-term light exposure. A shift in the low-frequency (LF) higher harmonic peak is observed after open-circuit light exposure, attributed to an altered electric field suggesting ion re-distribution, whereas closed-circuit exposure shows no LF shift, indicating minimal ion movement. Additionally, light exposure reduces higher-order admittance, more notably in open-circuit conditions, suggesting decreased recombination. Temperature-dependent analysis was conducted to characterize the activation energy of migrating species, identifying iodide as the dominant migrating ion.

14 SOLAR ENERGY↗

Mobilities of uranium and mercury ions in helium

The mobilities of mass-identified U(+) and Hg (+) ions in helium were determined in a drift tube-mass spectrometer. For uranium ions, a reduced mobility value is obtained at 305 K and a standard gas density of 2.69 x 10 to the 19th power/cu cm. The mobility of mercury ions is in agreement with two previous determinations. The effect of fast ion injection in drift mobility measurements is discussed, and a technique to circumvent these problems is described. The results are compared with existing theories of ion mobilities.

Johnsen, R.↗