At least 199 records · Page 11

Detection prospects for the Cosmic Neutrino Background using laser interferometers

The cosmic neutrino background is a key prediction of Big Bang cosmology which has not been observed yet. The movement of the earth through this neutrino bath creates a force on a pendulum, as if it were exposed to a cosmic wind. We revise here estimates for the resulting pendulum acceleration and compare it to the theoretical sensitivity of an experimental setup where the pendulum position is measured using current laser interferometer technology as employed in gravitational wave detectors. We discuss how a significant improvement of this setup can be envisaged in a micro gravity environment. The proposed setup could also function as a dark matter detector in the sub-MeV range, which currently eludes direct detection constraints.

79 ASTRONOMY AND ASTROPHYSICS↗

NAVY PRECISION OPTICAL INTERFEROMETER OBSERVATIONS OF THE EXOPLANET HOST {kappa} CORONAE BOREALIS AND THEIR IMPLICATIONS FOR THE STAR'S AND PLANET'S MASSES AND AGES

We used the Navy Precision Optical Interferometer to measure the limb-darkened angular diameter of the exoplanet host star {kappa} CrB and obtained a value of 1.543 {+-} 0.009 mas. We calculated its physical radius (5.06 {+-} 0.04 R{sub Sun }) and used photometric measurements from the literature with our diameter to determine {kappa} CrB's effective temperature (4788 {+-} 17 K) and luminosity (12.13 {+-} 0.09 L{sub Sun }). We then placed the star on an Hertzsprung-Russell diagram to ascertain the star's age (3.42{sup +0.32}{sub -0.25} Gyr) and mass (1.47 {+-} 0.04 M{sub Sun }) using a metallicity of [Fe/H] = +0.15. With this mass, we calculated the system's mass function with the orbital elements from a variety of sources, which produced a range of planetary masses: m{sub p}sin i = 1.61-1.88 M{sub Jup}. We also updated the extent of the habitable zone for the system using our new temperature.

79 ASTRONOMY AND ASTROPHYSICS↗

PLANETARY TRANSITS WITH THE ATACAMA LARGE MILLIMETER/SUBMILLIMETER ARRAY RADIO INTERFEROMETER

Planetary transits are commonly observed at visible wavelengths. Here we investigate the shape of a planetary transit observed at radio wavelengths. Solar maps at 17 GHz are used as a proxy for the stellar eclipse by several sizes of planets from super-Earths to hot Jupiters. The relative depth at mid-transit is the same as observed at visible wavelengths, but the limb brightening of the stellar disk at 17 GHz is clearly seen in the shape of the transit light curve. Moreover, when the planet occults an active region the depth of the transit decreases even further, depending on the brightness of the active region relative to the surrounding disk. For intense active region, with 50 times the brightness temperature of the surrounding disk, the decrease can supercede the unperturbed transit depth depending on the size of the eclipsing planet. For a super-Earth (R{sub p} = 0.02 R{sub s} ) crossing, the decrease in intensity is 0.04%, increasing to 0.86% in the case when a strong active region is present. On the other hand, for a hot Jupiter with R{sub p} = 0.17R{sub s} , the unperturbed transit depth is 3% increasing to 4.7% when covering this strong active region. This kind of behavior can be verified with observation of planetary transits with the Atacama Large Millimeter/submillimeter Array radio interferometer.

79 ASTRONOMY AND ASTROPHYSICS↗

The Tianlai dish pathfinder array: design, operation, and performance of a prototype transit radio interferometer

ABSTRACT The Tianlai Dish Pathfinder Array is a radio interferometer designed to test techniques for 21 cm intensity mapping in the post-reionization universe as a means for measuring large-scale cosmic structure. It performs drift scans of the sky at constant declination. We describe the design, calibration, noise level, and stability of this instrument based on the analysis of about 5% of 6200 h of on-sky observations through 2019 October. Beam pattern determinations using drones and the transit of bright sources are in good agreement, and compatible with electromagnetic simulations. Combining all the baselines, we make maps around bright sources and show that the array behaves as expected. A few hundred hours of observations at different declinations have been used to study the array geometry and pointing imperfections, as well as the instrument noise behaviour. We show that the system temperature is below 80 K for most feed antennas and that noise fluctuations decrease as expected with integration time, at least up to a few hundred seconds. Analysis of long integrations, from 10 nights of observations of the North Celestial Pole (NCP), yielded visibilities with amplitudes of 20–30 mK, consistent with the expected signal from the NCP radio sky with ${\lt}10\,$ mK precision for 1 MHz × 1 min binning. Hi-pass filtering the spectra to remove smooth spectrum signal yields a residual consistent with zero signal at the $0.5\,$ mK level.

(cosmology:) large-scale structure of the Universe↗

Atmospheric Emitted Radiance Interferometer Optimal Estimation (AERIoe) Value-Added Product Report

The Atmospheric Emitted Radiance Interferometer (AERI) Optimal Estimation (AERIoe) algorithm (Turner and Löhnert 2014, Turner and Blumberg 2019) retrieves boundary-layer profiles of temperature and water vapor mixing ratio, together with cloud properties for a single-layer cloud (i.e., LWP, effective radius), from AERI-observed infrared radiance spectra and other measurements. The current AERIoe Value-Added Product (VAP) uses version 2.8 of David Turner's code, which uses additional inputs to constrain the retrieval including surface meteorology, microwave radiometer brightness temperatures at any number of frequencies (the U.S. Department of Energy Atmospheric Radiation Measurement [ARM] user facility typically used observations at 23.8 and 30.0 GHz), and Rapid Refresh numerical weather prediction model output. The method is a physical iterative retrieval that uses the optimal estimation framework (Rodgers 2000), so a full error covariance of the solution and the information content (in the form of degrees of freedom for signal) is provided for each retrieval.

54 ENVIRONMENTAL SCIENCES↗

A High-Temperature Multipoint Hydrogen Sensor Using an Intrinsic Fabry–Perot Interferometer in Optical Fiber

This paper presents a multiplexable fiber optic chemical sensor with the capability of monitoring hydrogen gas concentration at high temperatures up to 750 °C. The Pd-nanoparticle infused TiO 2 films coated on intrinsic Fabry–Perot interferometer (IFPI) array were used as sensory films. Strains induced upon exposure to hydrogen with varied concentrations can be monitored by IFPI sensors. The fiber sensor shows a repetitive and reversible response when exposed to a low level (1–6%) of hydrogen gas. Uniform sensory behavior across all the sensing cavities is demonstrated and reported in this paper.

47 OTHER INSTRUMENTATION↗

A Coaxial Cable Fabry-Perot Interferometer for Sensing Applications

This paper reports a novel coaxial cable Fabry-Perot interferometer for sensing applications. The sensor is fabricated by drilling two holes half-way into a coaxial cable. The device physics was described. The temperature and strain responses of the sensor were tested. The measurement error was calculated and analyzed.

temperature and strain measurement↗

NULLING DATA REDUCTION AND ON-SKY PERFORMANCE OF THE LARGE BINOCULAR TELESCOPE INTERFEROMETER

The Large Binocular Telescope Interferometer (LBTI) is a versatile instrument designed for high angular resolution and high-contrast infrared imaging (1.5–13 μ m). In this paper, we focus on the mid-infrared (8–13 μ m) nulling mode and present its theory of operation, data reduction, and on-sky performance as of the end of the commissioning phase in 2015 March. With an interferometric baseline of 14.4 m, the LBTI nuller is specifically tuned to resolve the habitable zone of nearby main-sequence stars, where warm exozodiacal dust emission peaks. Measuring the exozodi luminosity function of nearby main-sequence stars is a key milestone to prepare for future exo-Earth direct imaging instruments. Thanks to recent progress in wavefront control and phase stabilization, as well as in data reduction techniques, the LBTI demonstrated in 2015 February a calibrated null accuracy of 0.05% over a 3 hr long observing sequence on the bright nearby A3V star β Leo. This is equivalent to an exozodiacal disk density of 15–30 zodi for a Sun-like star located at 10 pc, depending on the adopted disk model. This result sets a new record for high-contrast mid-infrared interferometric imaging and opens a new window on the study of planetary systems.

79 ASTRONOMY AND ASTROPHYSICS↗

CONFRONTING STANDARD MODELS OF PROTO-PLANETARY DISKS WITH NEW MID-INFRARED SIZES FROM THE KECK INTERFEROMETER

We present near- and mid-infrared (MIR) interferometric observations made with the Keck Interferometer Nuller and near-contemporaneous spectro-photometry from the infrared telescope facilities (IRTFs) of 11 well-known young stellar objects, several of which were observed for the first time in these spectral and spatial resolution regimes. With au-level spatial resolution, we first establish characteristic sizes of the infrared emission using a simple geometrical model consisting of a hot inner rim and MIR disk emission. We find a high degree of correlation between the stellar luminosity and the MIR disk sizes after using near-infrared data to remove the contribution from the inner rim. We then use a semi-analytical physical model to also find that the very widely used “star + inner dust rim + flared disk” class of models strongly fails to reproduce the spectral energy distribution (SED) and spatially resolved MIR data simultaneously; specifically a more compact source of MIR emission is required than results from the standard flared disk model. We explore the viability of a modification to the model whereby a second dust rim containing smaller dust grains is added, and find that the 2-rim model leads to significantly improved fits in most cases. This complexity is largely missed when carrying out SED modeling alone, although detailed silicate feature fitting by McClure et al. recently came to a similar conclusion. As has been suggested recently by Menu et al., the difficulty in predicting MIR sizes from the SED alone might hint at “transition disk”-like gaps in the inner au; however, the relatively high correlation found in our MIR disk size versus stellar luminosity relation favors layered disk morphologies and points to missing disk model ingredients instead.

79 ASTRONOMY AND ASTROPHYSICS↗

An accurate and efficient algorithm for detection of radio bursts with an unknown dispersion measure, for single-dish telescopes and interferometers

Astronomical radio signals are subjected to phase dispersion while traveling through the interstellar medium. To optimally detect a short-duration signal within a frequency band, we have to precisely compensate for the unknown pulse dispersion, which is a computationally demanding task. We present the “fast dispersion measure transform” algorithm for optimal detection of such signals. Our algorithm has a low theoretical complexity of 2N{sub f}N{sub t}+N{sub t}N{sub Δ}log{sub 2}(N{sub f}), where N{sub f}, N{sub t}, and N{sub Δ} are the numbers of frequency bins, time bins, and dispersion measure bins, respectively. Unlike previously suggested fast algorithms, our algorithm conserves the sensitivity of brute-force dedispersion. Our tests indicate that this algorithm, running on a standard desktop computer and implemented in a high-level programming language, is already faster than the state-of-the-art dedispersion codes running on graphical processing units (GPUs). We also present a variant of the algorithm that can be efficiently implemented on GPUs. The latter algorithm’s computation and data-transport requirements are similar to those of a two-dimensional fast Fourier transform, indicating that incoherent dedispersion can now be considered a nonissue while planning future surveys. We further present a fast algorithm for sensitive detection of pulses shorter than the dispersive smearing limits of incoherent dedispersion. In typical cases, this algorithm is orders of magnitude faster than enumerating dispersion measures and coherently dedispersing by convolution. We analyze the computational complexity of pulsed signal searches by radio interferometers. We conclude that, using our suggested algorithms, maximally sensitive blind searches for dispersed pulses are feasible using existing facilities. We provide an implementation of these algorithms in Python and MATLAB.

79 ASTRONOMY AND ASTROPHYSICS↗

Cosmology with the Laser Interferometer Space Antenna

The Laser Interferometer Space Antenna (LISA) has two scientific objectives of cosmological focus: to probe the expansion rate of the universe, and to understand stochastic gravitational-wave backgrounds and their implications for early universe and particle physics, from the MeV to the Planck scale. However, the range of potential cosmological applications of gravitational-wave observations extends well beyond these two objectives. This publication presents a summary of the state of the art in LISA cosmology, theory and methods, and identifies new opportunities to use gravitational-wave observations by LISA to probe the universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Compact instantaneous phase-shifting Sagnac interferometer for nanoscale tilt measurement

There is a large inter disciplinary need for high precision angular sensors in state-of-the-art technologies. This particularly applies to optical metrology in the field of Extreme Ultraviolet (EUV) or X-ray where the optics are commonly characterized in terms of slope errors at a nanoradian scale level. Here, in this paper, we present the in-lab development of an angular sensor based on a single reflection compact Sagnac interferometer using instantaneous phase shifting. Our automated prototype and first results show less than 15 nrad RMS repeatability, at least 200 nrad sensitivity and 280 nrad reproducibility over 100 μrad angular range.

36 MATERIALS SCIENCE↗

A Magnetometer Based on a Spin Wave Interferometer

Here, we describe a magnetic field sensor based on a spin wave interferometer. Its sensing element consists of a magnetic cross junction with four micro-antennas fabricated at the edges. Two of these antennas are used for spin wave excitation while two other antennas are used for detection of the inductive voltage produced by the interfering spin waves. Two waves propagating in the orthogonal arms of the cross may accumulate significantly different phase shifts depending on the magnitude and direction of the external magnetic field. This phenomenon is utilized for magnetic field sensing. The sensitivity attains its maximum under the destructive interference condition, where a small change in the external magnetic field results in a drastic increase of the inductive voltage, as well as in the change of the output phase. We report experimental data obtained for a micrometer scale Y 3 Fe 2 (FeO 4 ) 3 cross structure. The change of the inductive voltage near the destructive interference point exceeds 40 dB per 1 Oe. The phase of the output signal exhibits a π-phase shift within 1 Oe. The data are collected at room temperature. Taking into account the low thermal noise in ferrite structures, we estimate that the maximum sensitivity of the spin wave magnetometer may exceed attotesla.

47 OTHER INSTRUMENTATION↗

Theoretical and experimental analysis of the modulated phase grating X-ray interferometer

X-ray grating interferometry allows for the simultaneous acquisition of attenuation, differential-phase contrast, and dark-field images, resulting from X-ray attenuation, refraction, and small-angle scattering, respectively. The modulated phase grating (MPG) interferometer is a recently developed grating interferometry system capable of generating a directly resolvable interference pattern using a relatively large period grating envelope function that is sampled at a pitch that is small enough that X-ray spatial coherence can be achieved by using a microfocus X-ray source or G0 grating. We present the theory of the MPG interferometry system for a 2-dimensional staggered grating, derived using Fourier optics, and we compare the theoretical predictions with experiments we have performed with a microfocus X-ray system at Pennington Biomedical Research Center, LSU. The theoretical and experimental fringe visibility is evaluated as a function of grating-to-detector distance. Additionally, quantitative experiments are performed with porous carbon and alumina compounds, and the mean normalized dark-field signal is compared with independent porosimetry measurements. Qualitative analysis of attenuation and dark-field images of a dried anchovy are shown.

47 OTHER INSTRUMENTATION↗

High-sensitivity plasma density retrieval in a common-path second-harmonic interferometer through simultaneous group and phase velocity measurement

Precise measurements of the plasma density in ionized gas cells and discharged capillaries are critical to the design and operation of plasma-based accelerators, active plasma lenses, and plasma-based radiation sources. In this manuscript, a spectral-domain common-path second-harmonic interferometer is upgraded with the simultaneous measurement of the group and phase velocity, allowing for high-sensitivity density characterization (from the phase velocity advance) without the need for phase tracking from zero-density (enabled by the group velocity delay). The technique is applied to 1.5-cm-long plasma structures, without density ambiguity in parameter scans with >2π phase jumps. Finally, the single-shot sensitivity in phase retrieval is demonstrated at 63 mrad, equivalent to a density-length product of 1.8·10 15 cm -2 . This is an improvement of ×45 compared to group velocity analysis alone.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design study of a combined interferometer and polarimeter for a high-field, compact tokamak

This article is the first design study of a combined interferometer and polarimeter on a compact, high-field, high-density, net-energy tokamak. Recent advances in superconducting technology have made possible designs for compact, high magnetic field fusion power plants, such as ARC [Sorbom et al., Fusion Eng. Des. 100, 378 (2015)], and experiments, such as SPARC [Greenwald et al., PSFC Report No. RR-18-2 (2018)]. These new designs create both challenges and opportunities for plasma diagnostics. The diagnostic proposed in this work, called InterPol, takes advantage of unique opportunities provided by high magnetic field and density to measure both line-averaged density and poloidal magnetic field with a single set of CO 2 and quantum cascade lasers. These measurements will be used for fast density feedback control, constraint of density and safety factor profiles, and density fluctuation measurements. Synthetic diagnostic testing using a model machine geometry, called MQ1 (Mission Q ≥ 1), and profiles simulated with Tokamak Simulation Code indicate that InterPol will be able to measure steady state density and poloidal magnetic field, as well as fluctuations caused by toroidal Alfven eigenmodes and other phenomena on a high-field compact tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A multi-chord, two-color interferometer using Hilbert transform phase detection for measuring electron density in spheromak plasmas

A new, four-chord, CO 2 /He–Ne heterodyne interferometer has been designed and built for measuring line-averaged plasma density in the HIT-SI3 and subsequent HIT-SIU sustained spheromak devices. The two-color system successfully eliminates vibration-induced errors caused by mirrors that are secured to the vacuum chamber and is able to resolve electron densities ne in the full operating range of 10 18 –10 20 m –3 in both experiments with an integrated error of 4.7 × 10 17 m –2 . Here, data are presented from high toroidal current plasma discharges, showing the time evolution of electron densities n e and j Φ /n e along multiple chords.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Imaging velocity interferometer system for any reflector (VISAR) diagnostics for high energy density sciences

Two variants of optical imaging velocimetry, specifically the one-dimensional streaked line-imaging and the two-dimensional time-resolved area-imaging versions of the Velocity Interferometer System for Any Reflector (VISAR), have become important diagnostics in high energy density sciences, including inertial confinement fusion and dynamic compression of condensed matter. Here, we give a brief review of the historical development of these techniques, then describe the current implementations at major high energy density (HED) facilities worldwide, including the OMEGA Laser Facility and the National Ignition Facility. We illustrate the versatility and power of these techniques by reviewing diverse applications of imaging VISARs for gas-gun and laser-driven dynamic compression experiments for materials science, shock physics, condensed matter physics, chemical physics, plasma physics, planetary science and astronomy, as well as a broad range of HED experiments and laser-driven inertial confinement fusion research.