Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “instruments & instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

FY20 Report for Instrumentation Development for the Transient Testing Program

This yearly report provides a summary of accomplishments carried out under funding from the Department of Energy (DOE) Nuclear Technology Research and Development (NTRD) program for in-pile instrumentation supporting the transient testing program in FY20. These activities were performed in support of cross-cutting transient testing experiment objective. In this year, specific instrument R&D has been a lesser priority to years past, with complementary instrumentation R&D being ramped up under the DOE Advanced Sensors and Instrumentation Program. The primary focus of the work in FY20 pertain to defining a process and system, developed over the past several years, for developing, qualifying, and deploying instrumentation in in-pile experiments. The purpose of this report is to provide a summary of these outcomes and be a reference for researchers that are interested in developing in-pile instrumentation, with a particular emphasis on the Transient Reactor Test (TREAT) facility for deployment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Landsat Instrument Suite (LandIS) Sensor Design for the Landsat 10 Mission

Landsat 10 will be the upcoming mission in the 50+ year Landsat series of Earth observation platforms. The centerpiece of the observatory will be a super-spectral imager known as the Landsat Instrument Suite (LandIS). The sensor will feature 26 spectral channels from the visible through near-, short-wave, and thermal infrared wavelengths with spatial resolutions of 10, 20, and 60 meters on the ground, depending on the band. These enhancements over the legacy Landsat instruments will ensure data continuity with the existing archive and will expand upon the core Landsat capabilities to enable new applications in Earth science. After a competitive procurement, NASA selected the design submitted by the Raytheon Company for the LandIS instrument. The innovative Raytheon instrument concept utilizes an advanced whiskbroom architecture to fulfill the strict radiometric, spatial, and geometric image quality requirements demanded by the Landsat 10 mission and fits within restrictive mass, volume, and power constraints. The instrument will continue the Landsat directive to image all daylit land and near-shore water areas, along with select nighttime imaging. On-board calibration source data will ensure high radiometric and geometric accuracy and stability consistent with previous missions to enable continuity in data products available to users. This paper discusses the driving requirements for LandIS and provides a description of the chosen design and operations concept of the instrument.

Requirements↗

Instrumentation for the In-Core Real-Time Mechanical Testing of Structural Materials (INCREASE) Project

Idaho National Laboratory (INL), in collaboration with the Electric Power Research Institute (EPRI), the Nuclear Regulatory Commission (NRC), the French Atomic and Alternative Energies Commission (CEA), the Joint Research Center (JRC), the Nuclear Research and Consultancy Group (NRG), and the Research Center Rez (CVR), started a Joint Experimental Program (JEEP) project that operates within the Nuclear Energy Agency’s Framework for Irradiation Experiments (FIDES II) program in order to develop capabilities for the in-core real-time mechanical testing of structural materials. This effort will focus on designing a shared capsule capable of housing a variety of in-core mechanical testing instrumentation allowing enhanced experiments for the material science community. The outcome of the project would be high-priority, stress relaxation data for stainless-steel-based materials provided by EPRI and CEA. Stress relaxation is a major phenomenon that contributes to material degradation in nuclear reactor components. Currently, nuclear material stress relaxation is assessed both before and after irradiation, using complex and costly post-irradiation examination (PIE) activities. In-situ data would support the development of precision modeling and simulation of this degradation phenomena and would provide validation and benchmarking for existing models using the PIE data. As part of the U.S. Department of Energy Advanced Sensor and Instrumentation (ASI) program, INL has fabricated and tested out-of-core mechanical test instrumentation. This instrumentation was designed for easy adaptation to the irradiation capsule proposed under this JEEP, and can be deployed to measure real-time stress relaxation under pressurized-water reactor (PWR) conditions. This initial effort will partially serve to replace the testing capabilities lost because of shutting down the Halden Boiling Water Reactor (HBWR). The project would provide these capabilities to the international community via a shared capsule design that is easily adaptable to additional material test reactors. The design features will incorporate expansion to PWR and non-light-water reactor (LWR) environments that will be developed in future work. The capsule and instrumentation will be demonstrated in the Massachusetts Institute of Technology Reactor (MITR) for phase I and the Petten High Flux Reactor (HFR) for phase II irradiations to deliver real-time stress relaxation data on high priority stainless steel structural materials.

36 MATERIALS SCIENCE↗

Evolution of LIBS technology to mobile instrumentation for expediting firearm-related investigations at the laboratory and the crime scene

Gunshot residue (GSR) is one of the few forensic disciplines that lack accurate screening techniques. This study proposes using a mobile LIBS instrument to detect inorganic GSR and compares performance to a previously validated laboratory instrument. The mobile LIBS is designed with advanced configurations specifically for on-site GSR analysis, including a CMOS detector and a sampling chamber that holds up to six typical GSR collection devices with separate gas flow ports to prevent cross-contamination. A significant novelty of the portable instrument is its image magnification, which allows quick searching and visualization of GSR particle morphology. The single-particle imaging and elemental composition capability is one of a kind and offers superior confirmatory features for GSR. The mobile LIBS performance was evaluated for residues collected from the hands of shooters (100 samples) and non-shooters (200 background samples), analyzed sequentially by the mobile instrument and then the laboratory instrument. Accuracies better than 98.8% were obtained by both instruments, demonstrating their suitability for trace IGSR detection from skin specimens. Implementation of this methodology is anticipated to drastically speed up response times (i.e., from several hours per sample by standard SEM-EDS practice to a few minutes by LIBS). The screening methods can be easily incorporated into workflows to improve decision-making processes at the crime scene and laboratory settings, reduce backlogs, and improve case management.

47 OTHER INSTRUMENTATION↗

Instrument Control Software for Spectrophotometers

SRNL has developed instrument control software for diode array spectrophotometers that can be used for real time monitoring of dynamic systems. This software has evolved through several iterations as instruments have been developed for use in processing facilities at Savannah River Site. There are several noteworthy features of the software. The wavelength calibration is checked and updated in real time against reference emission lines that are designed into the instrument light source. Nonlinearities and offsets associated with the intensity response of the instruments are characterized, and absorbance spectra are appropriately corrected. These actions are necessary for accurate calculation of an absorbance spectrum from the intensity responses of two individual diode array detectors. The corrections also result in the spectra obtained for a particular sample by two (or more) different diode array detector pairs being nearly identical. This property assures consistent measurements at multiple locations with different instruments. It also permits the use of a single analyte calibration across many instruments without modification and without loss of accuracy

47 OTHER INSTRUMENTATION↗

Prism Assembly for Roman Space Telescope Wide Field Instrument Slit-less Spectroscopy

The Roman Space Telescope (RST) is a three mirror anastigmat design with a 2.4 m primary mirror. RST will be based in L2 orbit, from where it will provide science information on exoplanets and dark energy using the Coronagraph Instrument (CGI) and Wide Field Instrument (WFI). The WFI features a 300 megapixel near-infrared detector array which provides a field of view 100 times larger than that of Hubble Space Telescope. The Prism Assembly is a small add-on instrument to the Roman Space Telescope’s Wide Field Instrument (WFI), installed in a slot in WFI’s element wheel. The Prism assembly has a passband from 0.75 µm to 1.8 µm, enabling a survey of redshifts in the range 0.2 to 1.7 µm. It provides low resolution slit-less spectroscopy with a spectral resolution R > 70 for all wavelengths, and R < 170 for λ > 0.8 µm across the full field. The Prism Assembly has the potential to provide more supernova spectra than ground-based spectroscopy during the mission lifetime. Being a late add-on to the RST mission, the Prism Assembly has had restrictions on size, weight and geometry, and a challenging schedule, which has dictated much of the implementation. Despite these challenges, the Prism Assembly is a pocket-sized high-performance spectrographic element, implemented as a refractive, all-spherical optical design using only two elements, one S-TIH-1 glass and one CaF2. This presentation will give an overview of the Prism Assembly, from design and implementation, through alignment, test and calibration. (100 words): The Roman Space Telescope is a three mirror anastigmat design with a 2.4 m primary mirror, which will provide science information on dark energy and exoplanets. The Prism Assembly is a small add-on instrument to the telescope’s Wide Field Instrument, enabling low resolution slit-less spectroscopy with a spectral resolution 70 < R < 170 across the full field from λ= 0.75 µm to 1.8 µm. The Prism Assembly is a refractive, all-spherical optical design using a glass and a CaF2 element. This presentation will give an overview of the Prism Assembly, from design and implementation, through alignment, test and calibration.

Space Instrumentation↗

Aeronautic instruments

The development of aeronautic instruments. Vibrations, rapid changes of the conditions of flight and of atmospheric conditions, influence of the air stream all call for particular design and construction of the individual instruments. This is shown by certain examples of individual instruments and of various classes of instruments for measuring pressure, change of altitude, temperature, velocity, inclination and turning or combinations of these.

INSTRUMENTS↗

Carbonate clumped isotope analysis (Δ 47 ) of 21 carbonate standards determined via gas‐source isotope‐ratio mass spectrometry on four instrumental configurations using carbonate‐based standardization and multiyear data sets

Rationale Clumped isotope geochemistry examines the pairing or clumping of heavy isotopes in molecules and provides information about the thermodynamic and kinetic controls on their formation. The first clumped isotope measurements of carbonate minerals were first published 15 years ago, and since then, interlaboratory offsets have been observed, and laboratory and community practices for measurement, data analysis, and instrumentation have evolved. Here we briefly review historical and recent developments for measurements, share Tripati Lab practices for four different instrument configurations, test a recently published proposal for carbonate‐based standardization on multiple instruments using multi‐year data sets, and report values for 21 different carbonate standards that allow for recalculations of previously published data sets. Methods We examine data from 4628 standard measurements on Thermo MAT 253 and Nu Perspective IS mass spectrometers, using a common acid bath (90°C) and small‐sample (70°C) individual reaction vessels. Each configuration was investigated by treating some standards as anchors (working standards) and the remainder as unknowns (consistency standards). Results We show that different acid digestion systems and mass spectrometer models yield indistinguishable results when instrument drift is well characterized. For linearity correction, mixed gas‐and‐carbonate standardization or carbonate‐only standardization yields similar results. No difference is observed in the use of three or eight working standards for the construction of transfer functions. Conclusions We show that all configurations yield similar results if instrument drift is robustly characterized and validate a recent proposal for carbonate‐based standardization using large multiyear data sets. Δ 47 values are reported for 21 carbonate standards on both the absolute reference frame (ARF; also refered to as the Carbon Dioxide Equilibrated Scale or CDES) and the new InterCarb‐Carbon Dioxide Equilibrium Scale (I‐CDES) reference frame, facilitating intercomparison of data from a diversity of labs and instrument configurations and restandardization of a broad range of sample sets between 2006, when the first carbonate measurements were published, and the present.

58 GEOSCIENCES↗

Shielding development for the spallation neutron source VENUS instrument

VENUS is a neutron imaging instrument that will use a broad range of neutron wavelengths, from epithermal to cold energies, and will include enhanced contrast mechanisms. It will offer novel energy-selective imaging techniques directly connecting complex engineering materials and systems’ structures, properties, and functions to reveal practical and fundamental answers about their real-world performance. Here, the instrument will be built at SNS beamline 10, facing the decoupled poisoned hydrogen moderator. The driving cost for the instrument is the beamline and instrument cave shielding. Final analyses were performed to evaluate the thickness and composition of shielding materials for the instrument cave and beamline to meet radiation safety criteria for the instrument to start up in 2024 after completing the SNS proton power upgrade.

43 PARTICLE ACCELERATORS↗

Southern Great Plains (SGP) Aerosol Observing System (AOS) Instrument Handbook

The ARM AOSs are not instruments in and of themselves, but rather each is a collection of instruments that make up what is termed the “ARM Baseline Instrumentation”. The AMF3 AOS consists of the instruments listed above as well as any “guest” instruments that may be present during any given intensive operational period (IOP). A series of subsystems operate in the background and are essential to the operation of the instruments and the AOS as a whole.

54 ENVIRONMENTAL SCIENCES↗

Laboratory Instrument Software Controlled Spread Spectrum Time Domain Reflectometry for Electrical Cable Testing

This research discusses development of a software-controlled laboratory instrument based spread spectrum time domain reflectometry system (SSTDR). This constitutes one task within PNNL’s Light Water Sustainability Program (LWRS) whose mission includes advancing nondestructive examination (NDE) techniques for off-line and on-line in-situ cable condition monitoring. In 2022, PNNL evaluated SSTDR for detection and characterization of a number of cable anomalies (Glass et al. 2022). The review included comparison of SSTDR to Frequency Domain Reflectometry (FDR) techniques which have enjoyed encouraging feedback and are starting to be used in nuclear power plants for periodic cable condition monitoring of cable systems as part of the plant’s overall cable aging management program. The FDR test introduces a broad-band chirp onto the cable at the cable end then listens for any reflection from a change of impedance along the cable caused by a damaged conductor or insulation, splices, contact with moisture, or other cable anomalies. The signal is captured in the frequency domain then transformed back to the time domain using an inverse Fourier transform (IFT). Based on the velocity of propagation, the impedance response signal is plotted against distance along the cable. Peak locations along the X-axis indicate the distance along the cable where a portion of the signal has been reflected back to the instrument as a result of a cable anomaly. The FDR test is considered the gold standard of reflectometry however it does require the cable to be de-energized to perform the test. The LIVEWIRE commercial SSTDR produces a similar plot to the FDR however all processing is in the time domain. A pseudo-random noise code (PN code) is input onto the cable conductor and the instrument listens for any reflected response from cable anomalies. The SSTDR processes the signal as an autocorrelation comparing the input PN code to any reflected signal detected. The autocorrelation analysis for thermal aging, water and water ingress detection, ground fault and phase-to-phase fault detection at various locations along the cable and with the cable attached and detached from a motor load, and on both energized and un-energized conditions were performed. These results were contrasted to Frequency Domain Reflectometry (FDR) measurements of the un-energized cable. Results were encouraging but indicated more work was warranted – particularly with the SSTDR, it seemed that the insulation damage would likely be better evaluated with multiple bandwidth cable tests particularly including larger bandwidths than were possible with the current commercial instrument. The commercial instrument’s bandwidth was set at 6, 12, 24, and 48MHz but note that SSTDR and FDR definitions of bandwidth trend similarly but are not the same. The FDR response could be more broadly adjusted, and the bandwidth of 100 to 500 MHz produced the best responses. FDR responses to anomalies were clearer than SSTDR responses and indications were that a broader bandwidth SSTDR may lead to improved SSTDR detection capability. This project used a laboratory instrument based SSTDR (primarily using an Arbitrary Waveform Generator (AWG) and a digital oscilloscope plus Python in-house software) that allowed software adjustment of the SSTDR bandwidth, window functions applied to the exciting Pseudo-random Noise (PN) code plus and other aspects of the SSTDR signal processing. Hereafter, this will be referred to as the PNNL SSTDR. Evaluating specific performance of the PNNL SSTDR is left to a separate report. This report documents hardware and software development to produce the SSTDR cable test system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of TPS flight test and operational instrumentation

Thermal and flow sensor instrumentation was developed for use as an integral part of the space shuttle orbiter reusable thermal protection system. The effort was performed in three tasks: a study to determine the optimum instruments and instrument installations for the space shuttle orbiter RSI and RCC TPS; tests and/or analysis to determine the instrument installations to minimize measurement errors; and analysis using data from the test program for comparison to analytical methods. A detailed review of existing state of the art instrumentation in industry was performed to determine the baseline for the departure of the research effort. From this information, detailed criteria for thermal protection system instrumentation were developed.

Carnahan, K. R.↗

Report on monitoring and support instruments for solar physics research from Spacelab

The Quick Reaction and Special Purpose Facility Definition Team for Solar Physics Spacelab Payloads examined a variety of instruments to fulfill the following functions: (1) solar physics research appropriate to Spacelab, (2) correlative data for research in such fields as aeronomy, magnetospheric physics, ionospheric physics, meteorology and climatology, (3) target selection for activity alert monitoring and (4) pointing accuracy monitoring of Spacelab platforms. In this examination the team accepted a number of restrictions and qualifications: (1) the cost of such instruments must be low, so as not to adversely impact the development of new, research class instrumentation in the early Spacelab era; (2) the instruments should be of such a size that they each would occupy a small fraction of a pointing system, and (3) the weight and power consumption of the instruments should also be small. With these restrictions, the instruments chosen are: the visible light telescope and magnetograph, the extreme-ultraviolet telescope, and the solar irradiance monitor.

Source record↗

The SETI instrument development plan

The architecture of the instrument system for the SETI (Search for Extraterrestrial Intelligence) program is briefly described and the development approach used to implement the operational instruments is discussed. The two versions of the instrument system include a target survey instrument to observe at a very high sensitivity a selected set of interesting stars that have particular a priori promise, and a sky survey instrument to observe the entire celestial sphere at a lower sensitivity. The targeted survey utilizes the 305 meter antenna at Arecibo, Puerto Rico, a 64 meter DSN antenna, and other large radio telescopes. The Arecibo instrument provides the highest sensitivity by virtue of the antenna gain. The antenna line feeds cover an instantaneous frequency range of 50 MHz (tunable over 100 MHz), while the multichannel spectrum analyzer/signal detector is capable of analyzing a frequency segment 16 MHz wide with a maximum resolution of 1 Hz. The sky survey employs a listen-only, 34 meter antenna. The SETI breadboard development is also described.

Crow, R. B.↗

Eight microprocessor-based instrument data systems in the Galileo Orbiter spacecraft

Instrument data systems consist of a microprocessor, 3K bytes of Read Only Memory and 3K bytes of Random Access Memory. It interfaces with the spacecraft data bus through an isolated user interface with a direct memory access bus adaptor, and/or parallel data from instrument devices such as registers, buffers, analog to digital converters, multiplexers, and solid state sensors. These data systems support the spacecraft hardware and software communication protocol, decode and process instrument commands, generate continuous instrument operating modes, control the instrument mechanisms, acquire, process, format, and output instrument science data.

Barry, R. C.↗

In-flight assessment of workload using instrument scan

During instrument flight, the pilot obtains information concerning aircraft state by cross checking or scanning the flight instruments. The exact method of scanning the instrument panel varies from pilot to pilot but there are some basic features common to a good scan pattern. The method discussed may be considered a candidate for workload studies with piloting tasks which will invoke a regular visual scan (spatial/temporal pattern of eye movements) during instrument flight. It is important to point out that instrument scan by itself is not a complete indicator of workload nor is task attention necessarily associated with where the pilot happens to be looking at a particular instant. However, whenever instrument scan is required in a piloting task, analysis of scanning behavior may yield important direct or indirect information concerning workload.

Tole, J. R.↗

Mission description and in-flight operations of ERBE instruments on ERBS, NOAA 9, and NOAA 10 spacecraft

Instruments of the Earth Radiation Budget Experiment (ERBE) are operating on three different Earth-orbiting spacecraft. The Earth Radiation Budget Satellite (ERBS) is operated by NASA, and NOAA 9 and NOAA 10 weather satellites are operated by the National Oceanic and Atmospheric Administration (NOAA). This paper is the second in a series that describes the ERBE mission, and data processing and validation procedures. This paper describes the spacecraft and instrument operations for the second full year of in-orbit operations, which extend from February 1986 through January 1987. Validation and archival of radiation measurements made by ERBE instruments during this second year of operation were completed in July 1991. This period includes the only time, November 1986 through January 1987, during which all ERBE instruments aboard the ERBE, NOAA 9, and NOAA 10 spacecraft were simultaneously operational. This paper covers normal and special operations of the spacecraft and instruments, operational anomalies, and the responses of the instruments to in-orbit and seasonal variations in the solar environment.

Weaver, William L.↗

Telescience Testbed Program: A study of software for SIRTF instrument control

As a continued element in the Telescience Testbed Program (TTP), the University of Arizona Steward Observatory and the Electrical and Computer Engineering Department (ECE) jointly developed a testbed to evaluate the Operations and Science Instrument System (OASIS) software package for remote control of an instrument for the Space Infrared Telescope Facility (SIRTF). SIRTF is a cryogenically-cooled telescope with three focal plane instruments that will be the infrared element of NASA's Great Observatory series. The anticipated launch date for SIRTF is currently 2001. Because of the complexity of the SIRTF mission, it was not expected that the OASIS package would be suitable for instrument control in the flight situation, however, its possible use as a common interface during the early development and ground test phases of the project was considered. The OASIS package, developed at the University of Colorado for control of the Solar Mesosphere Explorer (SME) satellite, serves as an interface between the operator and the remote instrument which is connected via a network. OASIS provides a rudimentary windowing system as well as support for standard spacecraft communications protocols. The experiment performed all of the functions required of the MIPS simulation program. Remote control of the instrument was demonstrated but found to be inappropriate for SIRTF at this time for the following reasons: (1) programming interface is too difficult; (2) significant computer resources were required to run OASIS; (3) the communications interface is too complicated; (4) response time was slow; and (5) quicklook of image data was not possible.

Young, Erick T.↗