Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “insolation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Dynamic modeling and sensitivity analysis of solar thermal energy conversion systems

Since the energy input to solar thermal conversion systems is both time variant and probabilistic, it is unlikely that simple steady-state methods for estimating lifetime performance will provide satisfactory results. The work described here uses dynamic modeling to begin identifying what must be known about input radiation and system dynamic characteristics to estimate performance reliably. Daily operation of two conceptual solar energy systems was simulated under varying operating strategies with time-dependent radiation intensity ranging from smooth input of several magnitudes to input of constant total energy whose intensity oscillated with periods from 1/4 hour to 6 hours. Integrated daily system output and efficiency were functions of both level and dynamic characteristics of insolation. Sensitivity of output to changes in total input was greater than one.

Hamilton, C. L.↗

Investigation of techniques for inventorying forested regions. Volume 2: Forestry information system requirements and joint use of remotely sensed and ancillary data

The author has identified the following significant results. Effects of terrain topography in mountainous forested regions on LANDSAT signals and classifier training were found to be significant. The aspect of sloping terrain relative to the sun's azimuth was the major cause of variability. A relative insolation factor could be defined which, in a single variable, represents the joint effects of slope and aspect and solar geometry on irradiance. Forest canopy reflectances were bound, both through simulation, and empirically, to have nondiffuse reflectance characteristics. Training procedures could be improved by stratifying in the space of ancillary variables and training in each stratum. Application of the Tasselled-Cap transformation for LANDSAT data acquired over forested terrain could provide a viable technique for data compression and convenient physical interpretations.

Nalepka, R. F.↗

Potential applications of digital, visible, and infrared data from geostationary environmental satellites

An hourly, digital data base from the Visible/Infrared Spin-Scan Radiometer (VISSR) instrument on the GOES-1 and SMS-2 geostationary satellites is described. Several examples of developmental applications of these quantitative digital data are presented. These include a review of recent attempts to develop products that are of use to meteorologists who provide services to aviation, agriculture, forestry, hydrology, oceanography, and climatology. The sample products include high resolution thermal gradients of land and ocean surfaces, thermal change analyses, fruit frost/freeze application, cloud-top altitude analysis, analysis of hurricane characteristics, and analyses of solar insolation.

Miller, D. B.↗

Accelerated/abbreviated test methods, study 4 of task 3 (encapsulation) of the low-cost silicon solar array project

Inherent weatherability is controlled by the three weather factors common to all exposure sites: insolation, temperature, and humidity. Emphasis was focused on the transparent encapsulant portion of miniature solar cell arrays by eliminating weathering effects on the substrate and circuitry (which are also parts of the encapsulant system). The most extensive data were for yellowing, which were measured conveniently and precisely. Considerable data also were obtained on tensile strength. Changes in these two properties after outdoor exposure were predicted very well from accelerated exposure data.

Kolyer, J. M.↗

Development and testing of shingle-type solar cell molecules

The details of a shingle module design which produces in excess of 97 watts/sq m of module area at 1 kW/sq m insolation and at 60 C are reported. This selected design employs a tempered glass coverplate to provide the primary solar cell structural support. The fabrication and testing of a preproduction module of this design has demonstrated that this selected approach will meet the environmental testing requirements imposed by the contract.

Shepard, N. F.↗

An inverter/controller subsystem optimized for photovoltaic applications

Conversion of solar array dc power to ac power stimulated the specification, design, and simulation testing of an inverter/controller subsystem tailored to the photovoltaic power source characteristics. Optimization of the inverter/controller design is discussed as part of an overall photovoltaic power system designed for maximum energy extraction from the solar array. The special design requirements for the inverter/ controller include: a power system controller (PSC) to control continuously the solar array operating point at the maximum power level based on variable solar insolation and cell temperatures; and an inverter designed for high efficiency at rated load and low losses at light loadings to conserve energy.

Pickrell, R. L.↗

An evaluation of in situ ozone sensor performance during a cold frontal passage

The capabilities of the electrochemical concentration cell ozonesonde for measuring the vertical profile of atmospheric ozone were studied during a three day experiment at Wallops Island, Virginia, and Norfolk, Virginia. Using ancillary measurements at the surface and the spectrophotometer, it was concluded that the ozonesonde measures the total ozone overburden to within 10% of the real value. By releasing the balloon-borne instruments at a rate of four per day at each of the two sites, an indication was obtained of the temporal and spatial scales of atmospheric ozone variability. No significant effects of a weak cold front passage or of the loss of insolation at night were seen. An isolated incident of anomalously high ozone concentration at the peak of the profile was attributed to sporadic instrument performance effects. The data base currently available is not adequate for determining an exact cause of the anomaly.

Parsons, C. L.↗

Performance and stability analysis of a photovoltaic power system

The performance and stability characteristics of a 10 kVA photovoltaic power system are studied using linear Bode analysis and a nonlinear analog simulation. Power conversion efficiencies, system stability, and system transient performance results are given for system operation at various levels of solar insolation. Additionally, system operation and the modeling of system components for the purpose of computer simulation are described.

Merrill, W. C.↗

Evaluation of initial collector field performance at the Langley Solar Building Test Facility

The thermal performance of the solar collector field for the NASA Langley Solar Building Test Facility is given for October 1976 through January 1977. An 1180 square meter solar collector field with seven collector designs helped to provide hot water for the building heating system and absorption air conditioner. The collectors were arranged in 12 rows with nominally 51 collectors per row. Heat transfer rates for each row are calculated and recorded along with sensor, insolation, and weather data every 5 minutes using a mini-computer. The agreement between the experimental and predicted collector efficiencies was generally within five percentage points.

Boyle, R. J.↗

Solar power satellite status report

The development of a solar power satellite program is considered. It is suggested that the solar power satellite is an engineering rather than a science program - that is, that no scientific breakthroughs are required before initiating the project. Available technology is examined, and several key questions are discussed: how efficient is microwave transfer of energy; how feasible is construction in space; and will the advantages of continuous insolation compensate for the costs of building a solar power plant in synchronous orbit 23,000 miles above the earth.

Davis, H. P.↗

Temporal and latitudinal variations of stratospheric trace gases - A critical comparison between theory and experiment

Global calculations of stratospheric HOx, Clx, and NOx are presented which include the effects of planetary albedo and diurnal and seasonal variations of the insolation. Comparisons are made with a wide range of atmospheric measurements at different latitudes and altitudes. Agreement between theory and observations is generally within a factor of 2. The theory appears to explain adequately the major features of latitude and seasonal distributions of NO2 and HNO3. The results indicate that mesospheric OH makes an appreciable contribution to the total OH column abundance and strongly suggest that nitrogen oxides exist principally in the form of HNO3 at high latitudes in winter. There are difficulties in reconciling OH, ClO, and O3 observations in the upper stratosphere.

Wofsy, S. C.↗

Satellite mirror systems for providing terrestrial power - System concept

A system of orbiting reflectors, SOLARES, has been studied as a possible means of providing terrestrial power with a space system of minimum mass and complexity. The key impact that such a system, providing continuous and slightly concentrated insolation, makes on the economic viability of solar farming is demonstrated. New developments in solar sailing are incorporated to reduce mirror mass and transportation cost. The system is compatible with incremental implementation and continual expansion to produce the world's power needs. Key technology, environmental, and economic issues and payoffs are identified. SOLARES appears to be economically superior to other advanced, and even conventional, energy systems and could be scaled to completely abate our fossil fuel usage for power generation.

Billman, K. W.↗

Solar heating of the Martian dusty atmosphere

This paper examines the solar heating of the Martian atmosphere during the 1971 global dust storm observed by Mariner 9. Radiative scattering as well as absorption is included by utilizing the delta-Eddington approximation to the full radiative transfer equation. The necessary optical parameters are generated by a Mie program which uses a size distribution and a complex refractive index inferred from a number of sources, particularly from recent analyses of Mariner 9 UVS and TV observations. When uniform mixing of the dust is assumed, the solar heating per unit mass during a Martian global dust storm is remarkably uniform with height for small solar zenith angles. Heating rates may reach 80 K/day for overhead sunlight. Overall, 20% of the direct insolation is absorbed by the dust-laden atmosphere. Even optically thin widespread dust hazes may produce heating rates of several degrees Kelvin per day.

Zurek, R. W.↗

Liquid solar collector

Report documents evaluation test on commercial flat-plate solar collector that uses water as working fluid. Performance was measured before and after 34-day exposure to natural environment. Tables in metric and English units present data on air and water temperatures, waterflow, insolation, efficiency, and windspeed and direction.

Source record↗

Collector performance at various air-channel depths

Report describes evaluation of solar collector efficiency which was measured at airflow channel depths of 3, 2, 1, and 1/2 inches in solar simulator. Data were also recorded on absorber surface temperature, inlet and outlet temperatures, airflow and insolation rates, collector differential pressure and windspeed, for result tabulation and plotting.

Source record↗

Weathering of a flat-plate solar collector

Report contains performance evaluation of flat-plate liquid solar collector after 14-months of natural weathering. Collector efficiency was calculated and plotted as function of inlet liquid temperature. Measurements were made of ambient temperature, inlet and outlet temperatures, differential temperature and pressure, liquid flow rate, insolation, and windspeed.

Source record↗

Dryland pasture and crop conditions as seen by HCMM

The author has identified the following significant results. The soil moisture difference between the flight lines was partly due to water-holding capacity differences of the two soil types. Fields along the east flight line were in clay; while along the west flight line, the soil was sandy loam which holds less moisture. Due to differences in the amount of green material, the pastures were wetter than the wheat fields. Most of the pastures average from 40-80% green material, while wheat averages from 90-100% green material. A large amount of green material transpired more water and depleted the soil water content faster than dead vegetation. Visicorder data found temperature differences between the rangeland and winter wheat fields. Pasture had a larger percentage of dead material with different thermal properties than live vegetation, and surface temperature was primarily dependent on insolation. Dead material transpired less, but warms up faster than wheat fields.

Rosenthal, W. D.↗

Introductory assessment of orbiting reflections for terrestrial power generation

The use of orbiting mirrors for providing energy to ground conversion stations to produce electrical power is shown to be a viable, cost effective and environmentally sound alternative to satellite solar power stations and conventional power sources. This is accomplished with the use of very light weight metal coated polymeric films as mirrors which, after deployment at 800 km, are placed in operational orbit and controlled by solar radiation pressure. Relations are developed showing the influence of a number of parameters (mirror altitude, orbit inclination, period, mirror size and number, and atmospheric effects) on the reflected insolation that may be received by a ground spot as a function of location. Some attractive alternative uses of the reflection are briefly discussed as a beneficial adjuncts to the system.

Billman, K. W.↗