Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Fluence field optimization for noise and dose objectives in CT

Purpose: Selecting the appropriate imaging technique in computed tomography (CT) inherently involves balancing the tradeoff between image quality and imaging dose. Modulation of the x-ray fluence field, laterally across the beam, and independently for each projection, may potentially meet user-prescribed, regional image quality objectives, while reducing radiation to the patient. The proposed approach, called fluence field modulated CT (FFMCT), parallels the approach commonly used in intensity-modulated radiation therapy (IMRT), except ''image quality plans'' replace the ''dose plans'' of IMRT. This work studies the potential noise and dose benefits of FFMCT via objective driven optimization of fluence fields. Methods: Experiments were carried out in simulation. Image quality plans were defined by specifying signal-to-noise ratio (SNR) criteria for regions of interest (ROIs) in simulated cylindrical and oblong water phantoms, and an anthropomorphic phantom with bone, air, and water equivalent regions. X-ray fluence field patterns were generated using a simulated annealing optimization method that attempts to achieve the spatially-dependent prescribed SNR criteria in the phantoms while limiting dose (to the volume or subvolumes). The resulting SNR and dose distributions were analyzed and compared to results using a bowtie filtered fluence field. Results: Compared to using a fixed bowtie filtered fluence, FFMCT achieved superior agreement with the target image quality objectives, and resulted in integral dose reductions ranging from 39 to 52%. Prioritizing dose constraints for specific regions of interest resulted in a preferential reduction of dose to those regions with some tradeoff in SNR, particularly where the target low dose regions overlapped with regions where high SNR was prescribed. The method appeared fairly robust under increased complexity and heterogeneity of the object structure. Conclusions: These results support that FFMCT has the potential to meet prescribed image quality objectives, while decreasing radiation exposure to the patient. Tradeoffs between SNR and dose may not be eliminated, but might be more efficiently managed using FFMCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Initial Investigation of the Small Feature Detection Capability of the ORNL Fast Neutron Tomographic Imaging System

A variety of fast neutron imaging simulations and measurements were performed to investigate the spatial resolution and small feature detection capability of a fast-neutron tomographic imaging system developed at Oak Ridge National Laboratory. The system uses an associated particle DT (deuterium-tritium) neutron generator as the source and 25 mm × 25 mm × 100 mm plastic scintillators as the neutron detectors. Two image quality indicators were examined: 1) a variety of long steel pins embedded axially in the interior of a polyethylene cylinder and 2) a variety of short steels pins embedded radially in the surface of a shielded polyethylene cylinder. Measurements demonstrated detectability down to approximately 3 mm. Further data analysis may show improved detection performance and allow a more precise determination of the spatial resolution and small feature detection limit. The current DT generator has a neutron production spot size of about 3.5 mm, which appears to be the limiting factor in the current system configuration.

Wright, Michael C.↗

MERGING GALAXY CLUSTERS: OFFSET BETWEEN THE SUNYAEV-ZEL'DOVICH EFFECT AND X-RAY PEAKS

Galaxy clusters, the most massive collapsed structures, have been routinely used to determine cosmological parameters. When using clusters for cosmology, the crucial assumption is that they are relaxed. However, subarcminute resolution Sunyaev-Zel'dovich (SZ) effect images compared with high-resolution X-ray images of some clusters show significant offsets between the two peaks. We have carried out self-consistent N-body/hydrodynamical simulations of merging galaxy clusters using FLASH to study these offsets quantitatively. We have found that significant displacements result between the SZ and X-ray peaks for large relative velocities for all masses used in our simulations as long as the impact parameters were about 100-250 kpc. Our results suggest that the SZ peak coincides with the peak in the pressure times the line-of-sight characteristic length and not the pressure maximum (as it would for clusters in equilibrium). The peak in the X-ray emission, as expected, coincides with the density maximum of the main cluster. As a consequence, the morphology of the SZ signal, and therefore the offset between the SZ and X-ray peaks, change with viewing angle. As an application, we compare the morphologies of our simulated images to observed SZ and X-ray images and mass surface densities derived from weak-lensing observations of the merging galaxy cluster CL0152-1357, we find that a large relative velocity of 4800 km s{sup -1} is necessary to explain the observations. We conclude that an analysis of the morphologies of multi-frequency observations of merging clusters can be used to put meaningful constraints on the initial parameters of the progenitors.

79 ASTRONOMY AND ASTROPHYSICS↗

Accurate MTF measurement in digital radiography using noise response

Purpose: The authors describe a new technique to determine the system presampled modulation transfer function (MTF) in digital radiography using only the detector noise response. Methods: A cascaded-linear systems analysis was used to develop an exact relationship between the two-dimensional noise power spectrum (NPS) and the presampled MTF for a generalized detector system. This relationship was then utilized to determine the two-dimensional presampled MTF. For simplicity, aliasing of the correlated noise component of the NPS was assumed to be negligible. Accuracy of this method was investigated using simulated images from a simple detector model in which the ''true'' MTF was known exactly. Measurements were also performed on three detector technologies (an x-ray image intensifier, an indirect flat panel detector, and a solid state x-ray image intensifier), and the results were compared using the standard edge-response method. Flat-field and edge images were acquired and analyzed according to guidelines set forth by the International Electrotechnical Commission, using the RQA 5 spectrum. Results: The presampled MTF determined using the noise-response method for the simulated detector system was in close agreement with the true MTF with an averaged percent difference of 0.3% and a maximum difference of 1.1% observed at the Nyquist frequency (f{sub N}). The edge-response method of the simulated detector system also showed very good agreement at lower spatial frequencies (less than 0.5 f{sub N}) with an averaged percent difference of 1.6% but showed significant discrepancies at higher spatial frequencies (greater than 0.5 f{sub N}) with an averaged percent difference of 17%. Discrepancies were in part a result of noise in the edge image and phasing errors. For all three detector systems, the MTFs obtained using the two methods were found to be in good agreement at spatial frequencies less than 0.5 f{sub N} with an averaged percent difference of 3.4%. Above 0.5 f{sub N}, differences increased to an average of 20%. Deviations of the experimental results largely followed the trend seen in the simulation results, suggesting that differences between the two methods could be explained as resulting from the inherent inaccuracies of the edge-response measurement technique used in this study. Aliasing of the correlated noise component was shown to have a minimal effect on the measured MTF for the three detectors studied. Systems with significant aliasing of the correlated noise component (e.g., a-Se based detectors) would likely require a more sophisticated fitting scheme to provide accurate results. Conclusions: Results indicate that the noise-response method, a simple technique, can be used to accurately measure the MTF of digital x-ray detectors, while alleviating the problems and inaccuracies associated with use of precision test objects, such as a slit or an edge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulated refraction-enhanced X-ray radiography of laser-driven shocks

Refraction-enhanced x-ray radiography (REXR) is used to infer shock-wave positions of more than one shock wave, launched by a multiple-picket pulse in a planar plastic foil. This includes locating shock waves before the shocks merge, during the early time and the main drive of the laser pulse that is not possible with the velocity interferometer system for any reflector. Simulations presented in this paper of REXR show that it is necessary to incorporate refraction and attenuation of x rays along with the appropriate opacity and refractive-index tables to interpret experimental images. Simulated REXR shows good agreement with an experiment done on the OMEGA laser facility to image a shock wave. REXR can be applied to design multiple-picket pulses with a better understanding of the shock locations. Finally, this will be beneficial to obtain the required adiabats for inertial confinement fusion implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-G-JeP3-07: Real-Time Image Guided Radiation Therapy for Heterotopic Ossification in Patients After Hip Replacement

Purpose: To demonstrate the feasibility of using CBCT in a real-time image guided radiation therapy (IGRT) for single fraction heterotopic ossification (HO) in patients after hip replacement. In this real-time procedure, all steps, from simulation, imaging, planning to treatment delivery, are performed at the treatment unit in one appointment time slot. This work promotes real-time treatment to create a paradigm shift in the single fraction radiation therapy. Methods: An integrated real-time IGRT for HO was developed and tested for radiation treatment of heterotopic ossification for patient after hip replacement. After CBCT images are acquired at the linac, and sent to the treatment planning system, the physician determines the field and/or draws a block. Subsequently, a simple 2D AP/PA plan with prescription of 700 cGy is created on-the-fly for physician to review. Once the physician approves the plan, the patient is treated on the same simulation position. This real-time treatment requires the team of attending physician, physicist, therapists, and dosimetrist to work in harmony to achieve all the steps in a timely manner. Results: Ten patients have been treated with this real-time treatment, having the same beams arrangement treatment plan and prescription as our clinically regular CT-based 2D plans. The average time for these procedures are 52.9 ±10.7 minutes from the time patient entered the treatment room until s/he exited, and 37.7 ±8.6 minutes from starting CBCT until last beam delivered. Conclusion: The real-time IGRT for HO treatment has been tested and implemented to be a clinically accepted procedure. This one-time appointment greatly enhances the waiting time, especially when patients in high level of pain, and provides a convenient approach for the whole clinical staff. Other disease sites will be also tested with this new technology.

60 APPLIED LIFE SCIENCES↗

Deep-field analytical calibration

The next generation of imaging surveys, including the Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST), Euclid, and the Nancy Grace Roman Space Telescope, will provide unprecedented constraints on cosmology using weak gravitational lensing. To fully exploit this statistical power, shear measurement methods must achieve sub- per cent accuracy while mitigating systematic biases from noise, the point-spread function (PSF), blending, and shear-dependent detection. The analytical calibration framework (AnaCal) has demonstrated such accuracy but requires adding noise to images, reducing effective depth. We introduce Deep-Field Analytical Calibration (DEEP-FIELD AnaCal), an extension of AnaCal that uses deep-field images to compute shear responses while preserving the statistical power of wide-field data. We validate DEEP-FIELD AnaCal on isolated and blended galaxy image simulations with LSST-like conditions, finding it meets the stringent requirement of multiplicative bias $|m| < 3\times 10^{-3}$ at 99.7 per cent confidence. Compared to standard AnaCal applied to wide-field images, DEEP-FIELD AnaCal increases the effective galaxy number density from 17 to 30 arcmin$^{-2}$ for simulated 10-yr LSST data. With deep fields $10\times$ longer than the wide field, we find pixel noise variance in shear estimation is reduced by 30 per cent and overall uncertainty by $\sim 25~{{\ \rm per\ cent}}$. Finally, using the LSST Deep Drilling Fields strategy, we assess sample variance and find an equivalent calibration uncertainty of $\lesssim 0.3~{{\ \rm per\ cent}}$. These results demonstrate that DEEP-FIELD AnaCal offers a promising path to achieve the required shear calibration for upcoming weak lensing surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Quasiaperiodic grain boundary phases of Σ⁢5 tilt grain boundaries in refractory metals

We report ground-state structures and phase transitions in Σ⁢5⁢[001] tilt grain boundaries (GBs) in body-centered-cubic (bcc) refractory metals Nb, Ta, Mo, and W. Σ⁢5 tilt GBs have been extensively investigated over the past several decades, with their ground-state structure—composed of kite-shaped structural units—previously thought to be well understood. By performing a rigorous GB structure search that optimizes the number of atoms in the boundary core, we predict different quasiaperiodic “split kite” phases analogous to those previously found in GBs in face-centered-cubic metals. Furthermore, our results suggest that complex aperiodic phases of GBs appear to be a general phenomenon, as validated through density functional theory calculations. Moreover, the atoms in the split kite phase demonstrate distinct collective diffusion dynamics. Phase-contrast image simulations of split kites show better agreement with experimental observations, offering an alternative explanation for previous microscopy results and motivating future atomically resolved imaging of the GB structure.

Body-centered cubic↗

Using compressive sensing to recover images from PET scanners with partial detector rings

Purpose: Most positron emission tomography/computed tomography (PET/CT) scanners consist of tightly packed discrete detector rings to improve scanner efficiency. The authors’ aim was to use compressive sensing (CS) techniques in PET imaging to investigate the possibility of decreasing the number of detector elements per ring (introducing gaps) while maintaining image quality. Methods: A CS model based on a combination of gradient magnitude and wavelet domains (wavelet-TV) was developed to recover missing observations in PET data acquisition. The model was designed to minimize the total variation (TV) and L1-norm of wavelet coefficients while constrained by the partially observed data. The CS model also incorporated a Poisson noise term that modeled the observed noise while suppressing its contribution by penalizing the Poisson log likelihood function. Three experiments were performed to evaluate the proposed CS recovery algorithm: a simulation study, a phantom study, and six patient studies. The simulation dataset comprised six disks of various sizes in a uniform background with an activity concentration of 5:1. The simulated image was multiplied by the system matrix to obtain the corresponding sinogram and then Poisson noise was added. The resultant sinogram was masked to create the effect of partial detector removal and then the proposed CS algorithm was applied to recover the missing PET data. In addition, different levels of noise were simulated to assess the performance of the proposed algorithm. For the phantom study, an IEC phantom with six internal spheres each filled with F-18 at an activity-to-background ratio of 10:1 was used. The phantom was imaged twice on a RX PET/CT scanner: once with all detectors operational (baseline) and once with four detector blocks (11%) turned off at each of 0 °, 90 °, 180 °, and 270° (partially sampled). The partially acquired sinograms were then recovered using the proposed algorithm. For the third test, PET images from six patient studies were investigated using the same strategy of the phantom study. The recovered images using WTV and TV as well as the partially sampled images from all three experiments were then compared with the fully sampled images (the baseline). Comparisons were done by calculating the mean error (%bias), root mean square error (RMSE), contrast recovery (CR), and SNR of activity concentration in regions of interest drawn in the background as well as the disks, spheres, and lesions. Results: For the simulation study, the mean error, RMSE, and CR for the WTV (TV) recovered images were 0.26% (0.48%), 2.6% (2.9%), 97% (96%), respectively, when compared to baseline. For the partially sampled images, these results were 22.5%, 45.9%, and 64%, respectively. For the simulation study, the average SNR for the baseline was 41.7 while for WTV (TV), recovered image was 44.2 (44.0). The phantom study showed similar trends with 5.4% (18.2%), 15.6% (18.8%), and 78% (60%), respectively, for the WTV (TV) images and 33%, 34.3%, and 69% for the partially sampled images. For the phantom study, the average SNR for the baseline was 14.7 while for WTV (TV) recovered image was 13.7 (11.9). Finally, the average of these values for the six patient studies for the WTV-recovered, TV, and partially sampled images was 1%, 7.2%, 92% and 1.3%, 15.1%, 87%, and 27%, 25.8%, 45%, respectively. Conclusions: CS with WTV is capable of recovering PET images with good quantitative accuracy from partially sampled data. Such an approach can be used to potentially reduce the cost of scanners while maintaining good image quality.

60 APPLIED LIFE SCIENCES↗

The Advanced Gamma-ray Imaging System (AGIS) - Simulation Studies

The Advanced Gamma-ray Imaging System (AGIS) is a US-led concept for a next-generation instrument in ground-based very-high-energy gamma-ray astronomy. The most important design requirement for AGIS is a sensitivity of about 10 times greater than current observatories like Veritas, H.E.S.S or MAGIC. We present results of simulation studies of various possible designs for AGIS. The primary characteristics of the array performance, collecting area, angular resolution, background rejection, and sensitivity are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Image segmentation for analyzing galaxy-galaxy strong lensing systems

The goal of this Letter is to develop a machine learning model to analyze the main gravitational lens and detect dark substructure (subhalos) within simulated images of strongly lensed galaxies. Using the technique of image segmentation, we turn the task of identifying subhalos into a classification problem, where we label each pixel in an image as coming from the main lens, a subhalo within a binned mass range, or neither. Our network is only trained on images with a single smooth lens and either zero or one subhalo near the Einstein ring. On an independent test set with lenses with large ellipticities, quadrupole and octopole moments, and for source apparent magnitudes between 17–25, the area of the main lens is recovered accurately. On average, only 1.3% of the true area is missed and 1.2% of the true area is added to another part of the lens. In addition, subhalos as light as 10 8.5 M ⊙ can be detected if they lie in bright pixels along the Einstein ring. Furthermore, the model is able to generalize to new contexts it has not been trained on, such as locating multiple subhalos with varying masses or more than one large smooth lens.

79 ASTRONOMY AND ASTROPHYSICS↗

Testing the no-hair theorem with event horizon telescope observations of Sagittarius A*

The advent of the Event Horizon Telescope (EHT), a millimeter-wave very long baseline interferometric array, has enabled spatially resolved studies of the subhorizon-scale structure for a handful of supermassive black holes. Among these, the supermassive black hole at the center of the Milky Way, Sagittarius A* (Sgr A*), presents the largest angular cross section. Thus far, these studies have focused on measurements of the black hole spin and the validation of low-luminosity accretion models. However, a critical input in the analysis of EHT data is the structure of the black hole spacetime, and thus these observations provide the novel opportunity to test the applicability of the Kerr metric to astrophysical black holes. Here we present the first simulated images of a radiatively inefficient accretion flow (RIAF) around Sgr A* employing a quasi-Kerr metric that contains an independent quadrupole moment in addition to the mass and spin that fully characterize a black hole in general relativity. We show that these images can be significantly different from the images of an RIAF around a Kerr black hole with the same spin and demonstrate the feasibility of testing the no-hair theorem by constraining the quadrupolar deviation from the Kerr metric with existing EHT data. Equally important, we find that the disk inclination and spin orientation angles are robust to the inclusion of additional parameters, providing confidence in previous estimations assuming the Kerr metric based on EHT observations. However, at present, the limits on potential modifications of the Kerr metric remain weak.

79 ASTRONOMY AND ASTROPHYSICS↗

The Advanced Gamma-ray Imaging System (AGIS): Simulation studies

The Advanced Gamma-ray Imaging System (AGIS) is a next-generation ground-based gamma-ray observatory being planned in the U.S. The anticipated sensitivity of AGIS is about one order of magnitude better than the sensitivity of current observatories, allowing it to measure gamma-ray emission from a large number of Galactic and extra-galactic sources. We present here results of simulation studies of various possible designs for AGIS. The primary characteristics of the array performance - collecting area, angular resolution, background rejection, and sensitivity - are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Initial Investigation of the Small Feature Detection Capability of the ORNL Fast Neutron Tomographic Imaging System

A variety of fast neutron imaging simulations and measurements were performed to investigate the spatial resolution and small feature detection capability of a version of the Oak Ridge National Laboratory fast neutron tomographic imaging system. Two image quality indicators were examined: (1) a variety of long steel pins embedded axially in the interior of a polyethylene cylinder, and (2) a variety of short steels pins embedded radially in the surface of a polyethylene cylinder. Measurements demonstrated detectability of about 3 mm. Further data analysis may show improved detection performance and allow a more precise determination of the spatial resolution. Our current simulation code takes only partial consideration of the DT generator neutron production spot size, with neutron production effectively originating at a single point. Simulations showed that features less than 2 mm should be detectable with an improved generator. Our current ING-27 DT generator has a neutron production spot size of about 3.5 mm, which appears to be the limiting factor at present. Generators with spot sizes as small as 1 mm are commercially available. Higher-power, small–spot size associated particle generators are at the prototype stage and are expected to be commercially available soon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sympathetic crystallization of CaH{sup +} produced by a laser-induced reaction

We investigated sympathetic Coulomb crystallization of CaH{sup +} ions produced by a laser-induced reaction through an excited state according to {sup 40}Ca{sup +}(4p {sup 2}P{sub 1/2}) + H{sub 2} {yields} {sup 40}CaH{sup +} + H. {sup 40}CaH{sup +} ions stored in a linear Paul trap were characterized by their secular-motion excitation spectrum and by the modified fluorescence images of crystallized Ca{sup +} ions. The number of two-species crystallized ions, the secular motion temperature, and the structure were determined by molecular dynamics simulations. Both the observed two-species ion crystals and simulation images demonstrate that the CaH{sup +} ions were sympathetically crystallized with their secular-motion temperature being less than 10 mK. We determined reaction rates from fluorescence images of two-species Coulomb crystals by systematically changing the reaction time. In addition a lower limit for the reaction rate coefficient k=8x10{sup -10} cm{sup 3}/s was obtained.

74 ATOMIC AND MOLECULAR PHYSICS↗

Cryo diffraction microscopy: Ice conditions and finite supports

Using a signal-to-noise ratio estimation based on correlations between multiple simulated images, we compare the dose efficiency of two soft x-ray imaging systems: incoherent brightfield imaging using zone plate optics in a transmission x-ray microscope (TXM), and x-ray diffraction microscopy (XDM) where an image is reconstructed from the far-field coherent diffraction pattern. In XDM one must computationally phase weak diffraction signals; in TXM one suffers signal losses due to the finite numerical aperture and efficiency of the optics. In simulations with objects representing isolated cells such as yeast, we find that XDM has the potential for delivering equivalent resolution images using fewer photons. This can be an important advantage for studying radiation-sensitive biological and soft matter specimens.

36 MATERIALS SCIENCE↗

Signal-to-noise and radiation exposure considerations in conventional and diffraction x-ray microscopy

Using a signal-to-noise ratio estimation based on correlations between multiple simulated images, we compare the dose efficiency of two soft x-ray imaging systems: incoherent brightfield imaging using zone plate optics in a transmission x-ray microscope (TXM), and x-ray diffraction microscopy (XDM) where an image is reconstructed from the far-field coherent diffraction pattern. In XDM one must computationally phase weak diffraction signals; in TXM one suffers signal losses due to the finite numerical aperture and efficiency of the optics. In simulations with objects representing isolated cells such as yeast, we find that XDM has the potential for delivering equivalent resolution images using fewer photons. As a result, this can be an important advantage for studying radiation-sensitive biological and soft matter specimens.

36 MATERIALS SCIENCE↗