Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

An experimental assessment of the imaging quality of the low energy gamma-ray telescope ZEBRA

One gamma-ray detection plane of the ZEBRA telescope, consisting of nine position sensitive scintillation crystal bars designed to operate over the spectral range 0.2 to 10 MeV, has been constructed in the laboratory. A series of experimental images has been generated using a scaled down flight pattern mask in conjunction with a diverging gamma-ray beam. Point and extended sources have been imaged in order to assess quantitatively the performance of the system.

Butler, R. C.↗

Geometrical-Based Generative Adversarial Network to Enhance Digital Rock Image Quality

X-ray microcomputed tomography (micro-CT) is a common tool for the study of porous media structures and properties. High-quality micro-CT data are required to accurately capture pore structures. Acquiring high-quality micro-CT data, however, is not always possible, owing to application limitations and experimental constraints. Therefore, we propose a geometrical-based generative adversarial network (GAN) to rapidly restore noisy micro-CT images to their clean counterparts. The training data and related ground-truth (GT) data are scanned for 7 min and 9.5 h, respectively. To evaluate the performance of the geometrical-based GAN, a 6003 voxel image that has never been used for training is reconstructed and compared with the corresponding GT image. Histogram matching and linear normalization are implemented to adjust the histogram of the reconstructed image to that of the GT image. A watershed-based segmentation method is then applied to delineate pore and solid phases. Lastly, we measure the Minkowski functionals and petrophysical properties, including absolute permeability, pore size distribution, drainage capillary pressure-saturation curve, and imbibition relative permeability, to estimate the physical accuracy of the denoised image. The results show that the proposed geometrical-based GAN can accurately restore noisy micro-CT data. By reducing the scanning time from 9.5 h to 7 min, the expenditure of collecting micro-CT can be decreased significantly. This is particularly important for applications where time-lapse images of a dynamic process are required, high-throughput imaging is necessary for real-time data analysis, or where the quantification of large sample volumes is required.

58 GEOSCIENCES↗

Software to model AXAF-I image quality

A modular user-friendly computer program for the modeling of grazing-incidence type x-ray optical systems has been developed. This comprehensive computer software GRAZTRACE covers the manipulation of input data, ray tracing with reflectivity and surface deformation effects, convolution with x-ray source shape, and x-ray scattering. The program also includes the capabilities for image analysis, detector scan modeling, and graphical presentation of the results. A number of utilities have been developed to interface the predicted Advanced X-ray Astrophysics Facility-Imaging (AXAF-I) mirror structural and thermal distortions with the ray-trace. This software is written in FORTRAN 77 and runs on a SUN/SPARC station. An interactive command mode version and a batch mode version of the software have been developed.

Ahmad, Anees↗

Multilayer X-ray mirrors - Interfacial roughness, scattering, and image quality

Scattering of the multilayer coatings used for our normal incidence soft X-ray telescope at a wavelength of 63.5 A has been measured at 1.54 A and grazing angles of incidence and at soft X-rays near normal incidence. Furthermore, the edge of the moon is used as a known test target to estimate the amount of scattering in the arcsec range from images obtained on the date of the solar eclipse on July 11, 1991. The internal surfaces of the coating are inspected by high-resolution electron microscopy. A theoretical model describing the evolution and replication of roughness from layer to layer throughout the structure, which is in agreement with all experimental data, is presented. We find that practically all roughness caused by the growth of the multilayer structure occurs at spatial frequencies which are too high to produce scattering. The substrate roughness is replicated at lower spatial frequencies which might produce scattering within the field of view of an instrument. However, roughness in this range is below the 0.5 A level, again resulting in insignificant amounts of scatter.

Spiller, Eberhard↗

SU-F-I-58: Image Quality Comparisons of Different Motion Magnitudes and TR Values in MR-PET

Purpose: The aim of this work is to evaluate the accuracy and sensitivity of a respiratory-triggered MR-PET protocol in detecting four different sized lesions at two different magnitudes of motion, with two different TR values, using a novel PET-MR-CT compatible respiratory motion phantom. Methods: The eight-compartment torso phantom was setup adjacent to the motion stage, which moved four spherical compartments (28, 22, 17, 10 mm diameter) in two separate (1 and 2 cm) linear motion profiles, simulating a 3.5 second respiratory cycle. Scans were acquired on a 3T MR-PET system (Biograph mMR; Siemens Medical Solutions, Germany). MR measurements were taken with: 1) Respiratory-triggered T2-weighted turbo spin echo (BLADE) sequence in coronal orientation, and 2) Real-time balanced steady-state gradient echo sequence (TrueFISP) in coronal and sagittal planes. PET was acquired simultaneously with MR. Sphere geometries and motion profiles were measured and compared with ground truths for T2 BLADE-TSE acquisitions and real time TrueFISP images. PET quantification and geometry measurements were taken using standardized uptake values, voxel intensity plots and were compared with known values, and examined alongside MR-based attenuation maps. Contrast and signal-to-noise ratios were also compared for each of the acquisitions as functions of motion range and TR. Results: Comparison of lesion diameters indicate the respiratory triggered T2 BLADE-TSE was able to maintain geometry within −2 mm for 1 cm motion for both TR values, and within −3.1 mm for TR = 2000 ms at 2 cm motion. Sphere measurements in respiratory triggered PET images were accurate within +/− 5 mm for both ranges of motion for 28, 22, and 17 mm diameter spheres. Conclusion: Hybrid MR-PET systems show promise in imaging lung cancer in non-compliant patients, with their ability to acquire both modalities simultaneously. However, MR-based attenuation maps are still susceptible to motion derived artifacts and pose the potential to affect PET accuracy.

60 APPLIED LIFE SCIENCES↗

Simulation and studies of spaceborne synthetic aperture radar image quality with reduced bit rate

A computer simulation program that is used to study the effects of digitization in spaceborne synthetic aperture radar systems is described. An analytical study of the distortion noise introduced by the digitization process at various gain settings, sampling rates and bit error rates is presented and the results agree well with those obtained from the simulation program. The simulation program is also used to study the spatial frequency response of hard-limiting (quantizing to 1-bit) synthetic aperture radar systems. The implications of these results on synthetic aperture radar system design are discussed.

Li, F.↗

Effects of a despaced secondary of a Wolter type II telescope on image quality

The focal shift of the Wolter type II telescope, a glancing incidence analog of the normal incidence Cassegrain telescope, due to the despacing of the secondary with respect to the primary, is analyzed. The location of the rms best focus on the optical axis can be derived from a resulting expression. The results are verified by ray tracing of an actual Wolter type II telescope.

Saha, T. T.↗

A hybrid LBG/lattice vector quantizer for high quality image coding

It is well known that a vector quantizer is an efficient coder offering a good trade-off between quantization distortion and bit rate. The performance of a vector quantizer asymptotically approaches the optimum bound with increasing dimensionality. A vector quantized image suffers from the following types of degradations: (1) edge regions in the coded image contain staircase effects, (2) quasi-constant or slowly varying regions suffer from contouring effects, and (3) textured regions lose details and suffer from granular noise. All three of these degradations are due to the finite size of the code book, the distortion measures used in the design, and due to the finite training procedure involved in the construction of the code book. In this paper, we present an adaptive technique which attempts to ameliorate the edge distortion and contouring effects.

Ramamoorthy, V.↗

Software to model AXAF image quality

This draft final report describes the work performed under this delivery order from May 1992 through June 1993. The purpose of this contract was to enhance and develop an integrated optical performance modeling software for complex x-ray optical systems such as AXAF. The GRAZTRACE program developed by the MSFC Optical Systems Branch for modeling VETA-I was used as the starting baseline program. The original program was a large single file program and, therefore, could not be modified very efficiently. The original source code has been reorganized, and a 'Make Utility' has been written to update the original program. The new version of the source code consists of 36 small source files to make it easier for the code developer to manage and modify the program. A user library has also been built and a 'Makelib' utility has been furnished to update the library. With the user library, the users can easily access the GRAZTRACE source files and build a custom library. A user manual for the new version of GRAZTRACE has been compiled. The plotting capability for the 3-D point spread functions and contour plots has been provided in the GRAZTRACE using the graphics package DISPLAY. The Graphics emulator over the network has been set up for programming the graphics routine. The point spread function and the contour plot routines have also been modified to display the plot centroid, and to allow the user to specify the plot range, and the viewing angle options. A Command Mode version of GRAZTRACE has also been developed. More than 60 commands have been implemented in a Code-V like format. The functions covered in this version include data manipulation, performance evaluation, and inquiry and setting of internal parameters. The user manual for these commands has been formatted as in Code-V, showing the command syntax, synopsis, and options. An interactive on-line help system for the command mode has also been accomplished to allow the user to find valid commands, command syntax, and command function. A translation program has been written to convert FEA output from structural analysis to GRAZTRACE surface deformation file (.dfm file). The program can accept standard output files and list files from COSMOS/M and NASTRAN finite analysis programs. Some interactive options are also provided, such as Cartesian or cylindrical coordinate transformation, coordinate shift and scale, and axial length change. A computerized database for technical documents relating to the AXAF project has been established. Over 5000 technical documents have been entered into the master database. A user can now rapidly retrieve the desired documents relating to the AXAF project. The summary of the work performed under this contract is shown.

Ahmad, Anees↗