Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image plates”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Formation of scandium carbides and scandium oxycarbide from the elements at high-(P, T) conditions

Synchrotron diffraction experiments with in situ laser heated diamond anvil cells and multi-anvil press synthesis experiments have been performed in order to investigate the reaction of scandium and carbon from the elements at high-(P,T) conditions. It is shown that the reaction is very sensitive to the presence of oxygen. In an oxygen-rich environment the most stable phase is ScO{sub x}C{sub y}, where for these experiments x=0.39 and y=0.50-0.56. If only a small oxygen contamination is present, we have observed the formation of Sc{sub 3}C{sub 4}, Sc{sub 4}C{sub 3} and a new orthorhombic ScC{sub x} phase. All the phases formed at high pressures and temperatures are quenchable. Experimentally determined elastic properties of the scandium carbides are compared to values obtained by density functional theory based calculations. - Graphical Abstract Legend (TOC Figure): Table of Contents Figure Selected images recorded with a MAR345 image plate detector show the reaction of alpha-Sc and graphite at high-(P,T) conditions. Left: mixture of alpha-Sc and graphite. Right: recovered sample after laser heated the diamond anvil cell.

36 MATERIALS SCIENCE↗

Tritium Decay Helium-3 Effects in Tungsten

A critical challenge for long-term operation of ITER and beyond to a Demonstration reactor (DEMO) and future fusion reactor will be the development of plasma-facing components (PFCs) that demonstrate erosion resistance to steady-state/transient heat fluxes and intense neutral/ion particle fluxes under the extreme fusion nuclear environment, while at the same time minimizing in-vessel tritium inventories and permeation fluxes into the PFC’s coolant. Tritium will diffuse in bulk tungsten at elevated temperatures, and can be trapped in radiation-induced trap site (up to 1 at. % T/W) in tungsten [1,2]. Tritium decay into helium-3 may also play a major role in microstructural evolution (e.g. helium embrittlement) in tungsten due to relatively low helium-4 production (e.g. He/dpa ratio of 0.4-0.7 appm [3]) in tungsten. Tritium-decay helium-3 effect on tungsten is hardly understood, and its database is very limited. Two tungsten samples (99.99 at. % purity from A.L.M.T. Co., Japan) were exposed to high flux (ion flux of 1.0x1022 m-2s-1 and ion fluence of 1.0x1026 m-2) 0.5%T2/D2 plasma at two different temperatures (200, and 500°C) in Tritium Plasma Experiment (TPE) at Idaho National Laboratory. Tritium implanted samples were stored at ambient temperature in air for more than 3 years to investigate tritium decay helium-3 effect in tungsten. The tritium distributions on plasma-exposed was monitored by a tritium imaging plate technique during storage period [4]. Thermal desorption spectroscopy was performed with a ramp rate of 10°C/min up to 900°C to outgas residual deuterium and tritium but keep helium-3 in tungsten. These helium-3 implanted samples were exposed to deuterium plasma in TPE to investigate helium-3 effect on deuterium behavior in tungsten. The results show that tritium surface concentration in 200°C sample decreased to 30 %, but tritium surface concentration in 500°C sample did not alter over the 3 years storage period, indicating possible tritium retention in helium-3 bubble. This paper reports the initial experimental observation of tritium-decay helium-3 in tungsten exposed to deuterium/tritium plasma along with electron microscope analysis and also discusses a Tritium Migration Analysis Program (TMAP) analysis of tritium-decay helium-3 effects on tritium retention in tungsten for DEMO and future fusion reactor. [1] Y. Hatano, et.al., Nucl. Fusion 53 (2013) 073006 [2] M. Shimada, et.al., Nucl. Fusion 55 (2015) 013008 [3] M. Sawan, Fus. Sci. Technol. 66 (2014) 272 [4] T. Otsuka, Fus. Sci. Technol. 60 (2011) 1539 This work was prepared for the U.S. Department of Energy, Office of Fusion Energy Sciences, under the DOE Idaho Field Office contract number DE-AC07-05ID14517.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tritium distributions on W-coated divertor tiles used in the third JET ITER-like wall campaign

Tritium (T) distributions on tungsten (W)-coated plasma-facing tiles used in the third ITER-like wall campaign (2015–2016) of the Joint European Torus (JET) were examined by means of an imaging plate technique and β-ray induced x-ray spectrometry, and they were compared with the distributions after the second (2013–2014) campaign. Strong enrichment of T in beryllium (Be) deposition layers was observed after the second campaign. In contrast, T distributions after the third campaign was more uniform though Be deposition layers were visually recognized. The one of the possible explanations is enhanced desorption of T from Be deposition layers due to higher tile temperatures caused by higher energy input in the third campaign.

36 MATERIALS SCIENCE↗

Compact spectroscopy of keV to MeV X-rays from a laser wakefield accelerator

We reconstruct spectra of secondary X-rays from a tunable 250–350 MeV laser wakefield electron accelerator from single-shot X-ray depth-energy measurements in a compact (7.5 × 7.5 × 15 cm), modular X-ray calorimeter made of alternating layers of absorbing materials and imaging plates. X-rays range from few-keV betatron to few-MeV inverse Compton to > 100 MeV bremsstrahlung emission, and are characterized both individually and in mixtures. Geant4 simulations of energy deposition of single-energy X-rays in the stack generate an energy-vs-depth response matrix for a given stack configuration. An iterative reconstruction algorithm based on analytic models of betatron, inverse Compton and bremsstrahlung photon energy distributions then unfolds X-ray spectra, typically within a minute. We discuss uncertainties, limitations and extensions of both measurement and reconstruction methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High energy electron acceleration with PW-class laser system

We performed electron acceleration experiment with PW-class laser and a plasma tube, which was created by imploding a hollow polystyrene cylinder. In this experiment, electron energies in excess of 600 MeV have been observed. Moreover, the spectra of a comparatively high-density plasma {approx}10{sup 19} cm{sup -3} had a bump around 10 MeV. Additionally, we performed the absolute sensitivity calibration of imaging plate for 1 GeV electrons from the injector Linac of Spring-8 in order to evaluate absolute number of GeV-class electrons in the laser acceleration experiment.

43 PARTICLE ACCELERATORS↗

Synchrotron radiation microdiffraction of ballistic molten wax microdrops

Using stroboscopic techniques, diffraction patterns of ballistic paraffin wax microdrops have been observed. The microdrops, generated by a high-temperature ink-jet system, travel through the 1 {mu}m synchrotron radiation beam with a speed of about 1.4 m/s. Diffraction patterns were recorded in flight by a charge couple device with a microchannel plate image intensifier stage, which was activated with the microdrop generation frequency of 1000 Hz during 2 {mu}s. The data show liquid microdrops with a constant temperature up to 8 mm from the ink-jet system capillary exit. The general technique could be adapted for studying fast structural processes, such as protein conformational changes in aqueous microdrops.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In-situ X-ray structure measurements on aerodynamically levitated high temperature liquids

High energy, high flux X-ray sources enable new measurements of liquid and amorphous materials in extreme conditions. Aerodynamic levitation in combination with laser beam heating can be used to access high purity and non-equilibrium liquids at temperatures up to 3000 K. In this work, a small aerodynamic levitator was integrated with high energy beamline 11 ID-C at the Advanced Photon Source. Scattered X-rays were detected with a Mar345 image plate. The experiments investigated a series of binary in the CaO-Al{sub 2}O{sub 3}, MgO-SiO{sub 2}, SiO{sub 2}-Al{sub 2}O{sub 3} metal oxide compositions and pure SiO{sub 2}. The results show that the liquids exhibit large changes in structure when the predominant network former is diluted. Measurements on glasses with the same compositions as the liquids suggest that significant structural rearrangement consistent with a fragile-strong transition occurs in these reluctant glass forming liquids as they vitrify.

36 MATERIALS SCIENCE↗

Positron generation through laser Compton scattering gamma ray

The positron source is developed through a high brightness gamma-ray beam, which is produced from a laser light scattering off a high-energy electron beam circulating in a storage ring. A thin Pb target is irradiated by the gamma ray to generate positrons via pair creation. By using imaging plate, we measured the generation rate and worked out the energy spectrum of generated positrons and electrons. The experimental results are close to that from Monte Carlo simulation. About 3618 positrons/s at several MeV can be generated by the present experimental setup, and this value can be improved by optimizing experimental conditions.

36 MATERIALS SCIENCE↗

Structural stability and compressibility of group IV transition metals-based bulk metallic glasses under high pressure

High-pressure x-ray diffraction studies have been carried out on the two group IV transition metals-based bulk metallic glasses (BMGs) Zr{sub 57}Cu{sub 15.4}Ni{sub 12.6}Al{sub 10}Nb{sub 5} and Ti{sub 42}Zr{sub 24}Cu{sub 15.5}Ni{sub 14.5}Be{sub 4} to a pressure of 30 GPa at ambient temperature in a diamond anvil cell. Image plate x-ray diffraction studies under high pressure were carried out at a synchrotron source and the two BMG diffraction bands can be followed to the highest pressure using an internal copper pressure standard. The amorphous phase is observed to be stable to the highest static pressure of 30 GPa suggesting that the phase change observed in dynamical pressure experiments is related to an increase in temperature. The measured bulk modulus (B{sub 0}) and its pressure derivative (B') are 118 GPa and 3.11 for Zr-based BMG and 116 GPa and 2.84 for Ti-based BMG. The measured bulk modulus for BMG's by x-ray diffraction technique is consistent with the ultrasonic measurements. The decompression data reveal an increase in density by 3%-4% at ambient condition after pressure cycling to 30 GPa indicating reduction in excess free volume.

36 MATERIALS SCIENCE↗

Note: Construction of x-ray scattering and x-ray absorption fine structure beamline at the Pohang Light Source

A new hard x-ray beamline, 10B KIST-PAL beamline (BL10B), has been designed and constructed at the Pohang Light Source (PLS) in Korea. The beamline, operated by Pohang Accelerator Laboratory-Korean Institute of Science and Technology consortium, is dedicated to x-ray scattering (XRS) and x-ray absorption fine structure (XAFS) experiments. X rays with photon energies from 4.0 to 16.0 keV are delivered to the experimental station passing a collimating mirror, a fixed-exit double-crystal Si(111) monochromator, and a toroidal mirror. Basic experimental equipments for XAFS measurement, a high resolution diffractometry, an image plate detector system, and a hot stage have been prepared for the station. From our initial commissioning and performance testing of the beamline, it is observed that BL10B beamline can perform XRS and XAFS measurements successfully.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The New Structural Materials Science Beamlines BL8A and 8B at Photon Factory

BL8A and 8B are new beamlines for structural materials science at Photon Factory. The primary characteristics of both beamlines are similar. The incident beam is monochromatized by the Si(111) double-flat crystal monochromator and focused at the sample position by a Rh-coated bent cylindrical quartz mirror. The Weissenberg-camera-type imaging-plate (IP) diffractometers were installed. The X-ray diffraction experiments for structural studies of strongly correlated materials, such as transition metals, molecular conductors, endohedral fullerenes, nano-materials, etc, are conducted at these stations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermal gradient crystals as tuneable monochromator for high energy X-rays

At the high energy synchrotron radiation beamline BW5 at DORIS III at DESY a new monochromator providing broad energy bandwidth and high reflectivity is in use. On a small 10x10x5 mm{sup 3} silicon crystal scattering at the (311) reflection a thermal gradient is applied, which tunes the scattered energy bandwidth. The (311) reflection strongly suppresses the higher harmonics allowing the use of an image plate detector for crystallography. The monochromator can be used at photon energies above 60 keV.

43 PARTICLE ACCELERATORS↗

The RIKEN Materials Science Beamline at SPring-8: Towards Visualization of Electrostatic Interaction

In order to visualize molecular interaction by the experimental electrostatic potential analysis we have optimized the optical parameters and developed the high-resolution Debye-Scherrer camera at the RIKEN materials science beamline, BL44B2 of SPring-8. For the purpose the camera was designed to be equipped with the hybrid X-ray detector system. One is the conventional detector, the imaging plate readout off-line to carry out high d(interplanar spacing)-resolution measurements and the other is the CCD detector, which can be operated in a camera at variable distances for high angle-resolution measurements. In addition we have been developing an in-situ properties measurement system to visualize the electrostatic interaction completely synchronized with material functions.

43 PARTICLE ACCELERATORS↗

Commissioning of Angle Dispersive X-ray Diffraction Beamline on Indus-2

An Angle dispersive x-ray diffraction (ADXRD) beamline on bending magnet source of Indus-2 synchrotron (2.5 GeV, 300 mA) has been commissioned, for the study of single and polycrystalline samples. The beamline optics is based on vertically focusing Pt-coated pre and post mirrors and sagittal focusing Si (311) based double crystal monochromator. Experimental station consists of a six circle diffractometer equipped with scintillation detector and an image plate area detector for powder diffraction. XRD experiments have been performed to study single crystal and polycrystalline samples.

43 PARTICLE ACCELERATORS↗

High-resolution Thomson parabola for ion analysis

A new, versatile Thomson parabola ion energy (TPIE) analyzer has been designed, constructed, and used at the OMEGA-EP facility. Laser-accelerated multi-MeV ions from hemispherical C targets are transmitted through a W pinhole into a multi-kG magnetic field and subsequently through a parallel electric field of up to 25 kV/cm. The ion drift region has a user-selected length of 10, 50, or 80 cm. With the highest fields, 400-MeV C{sup 6+} and C{sup 5+} may be resolved. TPIE is ten-inch manipulator (TIM)-mounted at OMEGA-EP and can be used opposite either of the EP ps beams. The instrument runs on pressure-interlocked 15-Vdc power available in EP TIM carts. Flux control derives from the insertion depth into the target chamber and the user-selected pinhole dimensions. The detector consists of CR39 backed by an image plate. A fully relativistic simulation code for calculating ion trajectories was employed for design optimization. Excellent agreement of code predictions with the actual ion positions on the detectors is observed. Through pit counting of carbon-ion tracks in CR39, it is shown that conversion efficiency of laser light to energetic carbon ions exceeds {approx}5% for these targets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an x-ray diffraction camera used in magnetic fields up to 10 T

A high-field x-ray diffraction (HF-XRD) camera was developed to observe structural changes of magnetic materials in magnetic fields up to 10 T. The instrument mainly consists of a Debye-Scherrer-type camera with a diameter of 80.1 mm, a 10-T cryocooled superconducting magnet with a 100-mm room-temperature bore, an x-ray source, a power supply, and a chiller for the x-ray source. An x-ray detector (image plate) in the HF-XRD camera can be taken out and inserted into the magnet without changing the sample position. The performance of the instrument was tested by measuring the HF-XRD for silicon and ferromagnetic MnBi powders. A change of x-ray diffraction pattern was observed due to the magnetic orientation of MnBi, showing that the instrument is useful for studying field-induced orientation processes and structural properties of field-controlled materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative measurement of hard x-ray spectra for high intensity laser produced plasma

X-ray line spectra ranging from 17 to 77 keV were quantitatively measured with a Laue spectrometer, composed of a cylindrically curved crystal and a detector. Either a visible CCD detector coupled with a CsI phosphor screen or an imaging plate can be chosen, depending on the signal intensities and exposure times. The absolute sensitivity of the spectrometer system was calibrated using pre-characterized laser-produced x-ray sources and radioisotopes. The integrated reflectivity for the crystal is in good agreement with predictions by an open code for x-ray diffraction. The energy transfer efficiency from incident laser beams to hot electrons, as the energy transfer agency for specific x-ray line emissions, is derived as a consequence of this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-destructive assay of mechanical components using gamma-rays and thermal neutrons

This work presents the results obtained in the inspection of several mechanical components through neutron and gamma-ray transmission radiography. The 4.46 Multiplication-Sign 10{sup 5} n.cm{sup -2}.s{sup -1} thermal neutron flux available at the main port of the Argonauta research reactor in Instituto de Engenharia Nuclear has been used as source for the neutron radiographic imaging. The 412 keV {gamma}-ray emitted by {sup 198}Au, also produced in that reactor, has been used as interrogation agent for the gamma radiography. Imaging Plates - IP specifically designed to operate with thermal neutrons or with X-rays have been employed as detectors and storage devices for each of these radiations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗