Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

PSIDD3: Post-Scan Ultrasonic Data Display System for the Windows-Based PC Including Fuzzy Logic Analysis

Post-Scan Interactive Data Display (PSIDD) III is a user-oriented Windows-based system that facilitates the display and comparison of ultrasonic contact data. The system is optimized to compare ultrasonic measurements made at different locations within a material or at different stages of material degradation. PSIDD III provides complete analysis of the primary wave forms in the time and frequency domains along with the calculation of several frequency dependent properties including Phase Velocity and Attenuation Coefficient and several frequency independent properties, like the Cross Correlation Velocity. The system allows image generation on all of the frequency dependent properties at any available frequency (limited by the bandwidth used in the scans) and on any of the frequency independent properties. From ultrasonic contact scans, areas of interest on an image can be studied with regard to underlying raw waveforms and derived ultrasonic properties by simply selecting the point on the image. The system offers various modes of in-depth comparison between scan points. Up to five scan points can be selected for comparative analysis at once. The system was developed with Borland Delphi software (Visual Pascal) and is based on a SQL database. It is ideal for classification of material properties, or location of microstructure variations in materials.

Lovelace, Jeffrey J.↗

Ultrasonic Data Display and Analysis System Developed (Including Fuzzy Logic Analysis) for the Windows-Based PC

Post-Scan Interactive Data Display (PSIDD) III is a user-oriented Windows-based system that facilitates the display and comparison of ultrasonic contact measurement data obtained at NASA Glenn Research Center's Ultrasonic Nondestructive Evaluation measurement facility. The system is optimized to compare ultrasonic measurements made at different locations within a material or at different stages of material degradation. PSIDD III provides complete analysis of the primary waveforms in the time and frequency domains along with the calculation of several frequency-dependent properties including phase velocity and attenuation coefficient and several frequency-independent properties, like the cross correlation velocity. The system allows image generation on all the frequency-dependent properties at any available frequency (limited by the bandwidth used in the scans) and on any of the frequency-independent properties. From ultrasonic contact scans, areas of interest on an image can be studied with regard to underlying raw waveforms and derived ultrasonic properties by simply selecting the point on the image. The system offers various modes of indepth comparison between scan points. Up to five scan points can be selected for comparative analysis at once. The system was developed with Borland Delphi software (Visual Pascal) and is based on an SQL data base. It is ideal for the classification of material properties or the location of microstructure variations in materials. Along with the ultrasonic contact measurement software that it is partnered with, this system is technology ready and can be transferred to users worldwide.

Lovelace, Jeffrey J.↗

Image Quality Indicator for Infrared Inspections

The quality of images generated during an infrared thermal inspection depends on many system variables, settings, and parameters to include the focal length setting of the IR camera lens. If any relevant parameter is incorrect or sub-optimal, the resulting IR images will usually exhibit inherent unsharpness and lack of resolution. Traditional reference standards and image quality indicators (IQIs) are made of representative hardware samples and contain representative flaws of concern. These standards are used to verify that representative flaws can be detected with the current IR system settings. However, these traditional standards do not enable the operator to quantify the quality limitations of the resulting images, i.e. determine the inherent maximum image sensitivity and image resolution. As a result, the operator does not have the ability to optimize the IR inspection system prior to data acquisition. The innovative IQI described here eliminates this limitation and enables the operator to objectively quantify and optimize the relevant variables of the IR inspection system, resulting in enhanced image quality with consistency and repeatability in the inspection application. The IR IQI consists of various copper foil features of known sizes that are printed on a dielectric non-conductive board. The significant difference in thermal conductivity between the two materials ensures that each appears with a distinct grayscale or brightness in the resulting IR image. Therefore, the IR image of the IQI exhibits high contrast between the copper features and the underlying dielectric board, which is required to detect the edges of the various copper features. The copper features consist of individual elements of various shapes and sizes, or of element-pairs of known shapes and sizes and with known spacing between the elements creating the pair. For example, filled copper circles with various diameters can be used as individual elements to quantify the image sensitivity limit. Copper line-pairs of various sizes where the line width is equivalent to the spacing between the lines can be used as element-pairs to quantify the image resolution limit.

Burke, Eric↗

Gamma-ray imaging of Np-237 metal using an organic glass imager

Neutron and gamma-ray imaging systems are deployed within the field of nuclear safeguards for the detection and localization of special nuclear materials and other materials of interest. 237 Np is one of these materials of interest due its presence in spent nuclear fuel and potential for use in nuclear weapons when purified. Here, for the first time, a 6 kg neptunium sphere (98.8 wt% 237 Np) was measured using a dual-particle imager, from the University of Michigan, consisting of organic glass and inorganic scintillators. The novel composition of organic glass scintillator was recently developed at Sandia National Labs and has been used in particle imaging systems due to its time resolution and particle discrimination capabilities. Gamma-ray energy spectra from single and coincident events were extracted and the sequencing of Compton scatter and photoelectric absorption gamma-ray events was used to generate images using simple backprojection. The emissions of interest in this work are the 312 keV and 416 keV gamma rays from 233 Pa, a daughter isotope from the neptunium decay series. The results of this work show that there is close agreement between the true source location in angular space and the converged location from the gamma ray images created using the system. The gamma spectroscopy from single and coincident events also identified the characteristic emission from the daughter isotope and could be used to assist with the identification of 237 Np. Furthermore, successful localization of the source with 5 s of data demonstrates the practical application of the imaging system for imaging and detection of material in weapons-useable quantities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Systems Map, Monitor, and Manage Earth's Resources

SpecTIR LLC, headquartered in Reno, Nevada, is recognized for innovative sensor design, on-demand hyperspectral data collection, and image-generating products for business, academia, and national and international governments. SpecTIR's current vice president of business development has brought a wealth of NASA-related research experience to the company, as the former principal investigator on a NASA-sponsored hyperspectral crop-imaging project. This project, made possible through a Small Business Technology Transfer (STTR) contract with Goddard Space Flight Center, aimed to enhance airborne hyperspectral sensing and ground-truthing means for crop inspection in the Mid-Atlantic region of the United States. Areas of application for such technology include precision farming and irrigation; oil, gas, and mineral exploration; pollution and contamination monitoring; wetland and forestry characterization; water quality assessment; and submerged aquatic vegetation mapping. Today, SpecTIR maintains its relationship with Goddard through programs at the University of Maryland in College Park, Maryland, and at the U.S. Department of Agriculture campus in Beltsville, Maryland. Additionally, work continues on the integration of hyperspectral data with LIDAR systems and other commercial-off-the-shelf technologies.

Source record↗

Analytical methods for superresolution dislocation identification in dark-field X-ray microscopy

In this work, we develop several inference methods to estimate the position of dislocations from images generated using dark-field X-ray microscopy (DFXM)—achieving superresolution accuracy and principled uncertainty quantification. Using the framework of Bayesian inference, we incorporate models of the DFXM contrast mechanism and detector measurement noise, along with initial position estimates, into a statistical model coupling DFXM images with the dislocation position of interest. We motivate several position estimation and uncertainty quantification algorithms based on this model. We then demonstrate the accuracy of our primary estimation algorithm on synthetic realistic DFXM images of edge dislocations in single-crystal aluminum. We conclude with a discussion of our methods’ impact on future dislocation studies and possible future research avenues.

36 MATERIALS SCIENCE↗

Using AI for Wave-front Estimation with the Rubin Observatory Active Optics System

Abstract The Vera C. Rubin Observatory will, over a period of 10 yr, repeatedly survey the southern sky. To ensure that images generated by Rubin meet the quality requirements for precision science, the observatory will use an active-optics system (AOS) to correct for alignment and mirror surface perturbations introduced by gravity and temperature gradients in the optical system. To accomplish this, Rubin will use out-of-focus images from sensors located at the edge of the focal plane to learn and correct for perturbations to the wave front. We have designed and integrated a deep-learning (DL) model for wave-front estimation into the AOS pipeline. In this paper, we compare the performance of this DL approach to Rubin’s baseline algorithm when applied to images from two different simulations of the Rubin optical system. We show the DL approach is faster and more accurate, achieving the atmospheric error floor both for high-quality images and low-quality images with heavy blending and vignetting. Compared to the baseline algorithm, the DL model is 40× faster, the median error 2× better under ideal conditions, 5× better in the presence of vignetting by the Rubin camera, and 14× better in the presence of blending in crowded fields. In addition, the DL model surpasses the required optical quality in simulations of the AOS closed loop. This system promises to increase the survey area useful for precision science by up to 8%. We discuss how this system might be deployed when commissioning and operating Rubin.

79 ASTRONOMY AND ASTROPHYSICS↗

Stereographic cloud heights from imagery of SMS/GOES satellites

Stereographic pairs of SMS/GOES images, generated simultaneously by the spin-scan cameras of each of two geostationary satellites (SMS 1 and SMS 2, separated by 32 degrees of longitude on February 17, 1975), have been analyzed photogrammetrically to yield cloud heights with a two-sigma uncertainty of 500 meters. The 32-degree angle between the image plane of the two satellites, plus the distortions involved in transferring the image of a nearly full hemisphere of the earth onto a plane, required the development of a special instrument to permit stereographic compilation. Cloud heights measured stereographically compared favorably with heights of the same clouds measured by radar and IR methods. The same SMS image pairs were used to measure mountain-top heights with a mean deviation of 0.24 km from cartographic values.

Minzner, R. A.↗

Anisotropic emission from comets: Fans versus jets. 1: Concept and modeling

Jets and fans of dust ejected from discrete emission sources on the sunlit side of comet nuclei were studied. Computer-generated images of these features illustrate the diversity of patterns that can be explained by varying the position of the spin axis, rotation period, location and extent of the active area, and the ejecta's dynamical constants for a given Sun-Earth-comet geometry. It is shown that an emission fan is generated by rotation of a high-latitude source about the spin axis of the nucleus with a relatively high obliquity, but that the fan's formation is rather insensitive to the rotation period. It appears that at least for comets with perihelia well outside the Earth's orbit, the position angle of a fan's observed axis virtually coincides with the projected direction of the spin axis, thus constraining the spatial orientation of the latter.

Sekanina, Z.↗

Uncertainty analysis of PIV measurements in bubbly flows considering sampling and bubble effects with ray optics modeling

In this report, a modeling-based approach is developed to investigate the external sources of uncertainty in particle image velocimetry (PIV) measurements for two-phase bubbly flows. Primarily relied on ray optics modeling, this study focuses on the uncertainty in PIV measurements due to bubble-induced light distortion. In addition, the uncertainty due to sampling is also considered through synthetic PIV images generated from Monte Carlo sampling. Based on a PIV-planar laser induced florescence (PLIF) measurement system, three case studies are performed and discussed, considering respectively the sampling effect, bubble effect, and the combination of these two effects. These case studies confirm the validity of the ray optics modeling in obtaining accurate particle images through a benchmark test. Furthermore, it is also found that the bubble effect could significantly influence the particle images. On the other hand, the result of the case study with synthetic PIV images indicates that the bubble effect on particle images can be minimized by removing “outliers” in the obtained velocity vector field through a multi-pass post-processing procedure. However, the uncertainty of the velocity measurements will still increase.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Conceptual design study for an advanced cab and visual system, volume 1

A conceptual design study was conducted to define requirements for an advanced cab and visual system. The rotorcraft system integration simulator is for engineering studies in the area of mission associated vehicle handling qualities. Principally a technology survey and assessment of existing and proposed simulator visual display systems, image generation systems, modular cab designs, and simulator control station designs were performed and are discussed. State of the art survey data were used to synthesize a set of preliminary visual display system concepts of which five candidate display configurations were selected for further evaluation. Basic display concepts incorporated in these configurations included: real image projection, using either periscopes, fiber optic bundles, or scanned laser optics; and virtual imaging with helmet mounted displays. These display concepts were integrated in the study with a simulator cab concept employing a modular base for aircraft controls, crew seating, and instrumentation (or other) displays. A simple concept to induce vibration in the various modules was developed and is described. Results of evaluations and trade offs related to the candidate system concepts are given, along with a suggested weighting scheme for numerically comparing visual system performance characteristics.

Rue, R. J.↗

Statistical mechanics and invariant perception

The problem of discrimination among ensembles of images generated by distortions of a prototype and the addition of noise is considered. As the noise level is increased, the discrimination task becomes qualitatively more difficult in that optimal discrimination requires the computation of increasingly longer-ranged correlations, or the solution of increasingly difficult optimization problems. These results suggest the use of such image ensembles in probing the computational abilities of the human visual system, and possible theoretical implications of such experiments are discussed.

Bialek, William↗

Dual-energy fast neutron imaging using tunable short-pulse laser-driven sources

Here a novel dual-energy fast neutron imaging technique is presented using short-pulse laser-driven neutron sources to leverage their inherent adaptive spectral control to enable 3D volume segmentation and reconstruction. Laser-accelerated ion beams incident onto secondary targets create directional, broadband, MeV-class neutrons. Synthetic radiographs are produced of multi-material objects using ion and neutron spectra derived from analytic and numerical models. It is demonstrated that neutron images generated from small changes to the neutron spectra, controlled by altering the initial laser conditions, are sufficient to isolate materials with differing attenuation coefficients. This is first demonstrated using a simplistic combinatorial isolation method and then by employing more advanced reconstruction algorithms to reduce artifacts and generate a segmentation volume of the constituent materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Structure of Coronal Loops

It is widely believed that the simple coronal loops observed by XUV imagers, such as EIT, TRACE, or XRT, actually have a complex internal structure consisting of many (perhaps hundreds) of unresolved, interwoven "strands". According to the nanoflare model, photospheric motions tangle the strands, causing them to reconnect and release the energy required to produce the observed loop plasma. Although the strands, themselves, are unresolved by present-generation imagers, there is compelling evidence for their existence and for the nanoflare model from analysis of loop intensities and temporal evolution. A problem with this scenario is that, although reconnection can eliminate some of the strand tangles, it cannot destroy helicity, which should eventually build up to observable scales. we consider, therefore, the injection and evolution of helicity by the nanoflare process and its implications for the observed structure of loops and the large-scale corona. we argue that helicity does survive and build up to observable levels, but on spatial and temporal scales larger than those of coronal loops. we discuss the implications of these results for coronal loops and the corona, in general .

Antiochos, Spiro K.↗

Database Integrity Monitoring for Synthetic Vision Systems Using Machine Vision and SHADE

In an effort to increase situational awareness, the aviation industry is investigating technologies that allow pilots to visualize what is outside of the aircraft during periods of low-visibility. One of these technologies, referred to as Synthetic Vision Systems (SVS), provides the pilot with real-time computer-generated images of obstacles, terrain features, runways, and other aircraft regardless of weather conditions. To help ensure the integrity of such systems, methods of verifying the accuracy of synthetically-derived display elements using onboard remote sensing technologies are under investigation. One such method is based on a shadow detection and extraction (SHADE) algorithm that transforms computer-generated digital elevation data into a reference domain that enables direct comparison with radar measurements. This paper describes machine vision techniques for making this comparison and discusses preliminary results from application to actual flight data.

Cooper, Eric G.↗

The Shuttle Mission Simulator computer generated imagery

Equipment available in the primary training facility for the Space Transportation System (STS) flight crews includes the Fixed Base Simulator, the Motion Base Simulator, the Spacelab Simulator, and the Guidance and Navigation Simulator. The Shuttle Mission Simulator (SMS) consists of the Fixed Base Simulator and the Motion Base Simulator. The SMS utilizes four visual Computer Generated Image (CGI) systems. The Motion Base Simulator has a forward crew station with six-degrees of freedom motion simulation. Operation of the Spacelab Simulator is planned for the spring of 1983. The Guidance and Navigation Simulator went into operation in 1982. Aspects of orbital visual simulation are discussed, taking into account the earth scene, payload simulation, the generation and display of 1079 stars, the simulation of sun glare, and Reaction Control System jet firing plumes. Attention is also given to landing site visual simulation, and night launch and landing simulation.

Henderson, T. H.↗

Alignment and Characterization of High Uniformity Imaging Spectrometers

Imaging spectrometers require precise adjustments, in some cases at the sub-micrometer level, in order to achieve auniform response over both the spectral and spatial dimensions. We describe a set of measurement techniques and theircorresponding alignment adjustments to achieve the 95% or higher uniformity specifications required for Earthobservingimaging spectrometers. The methods are illustrated with measurements from the Next Generation Imaging Spectrometer system that has been built at the Jet Propulsion Laboratory, California Institute of Technology, under contract with the National Aeronautics and Space Administration.

Offner spectrometer↗

Low-intensity x-ray and gamma-ray imaging device

Low-dosage, low-power X-ray system can be made completely self-contained, allowing fluoroscopy and radiography to be carried out in field and remote locations. New device, known as "lixiscope," can be used with conventional X-ray machine turned down to low level, or, it can be operated with radioisotope source for hand-held portable applications. Originally developed for X-ray astronomy, lixiscope obtains high sensitivity by using intermediate stages of photoelectron conversion and electron amplification to generate image suitable for direct viewing or for recording on film.

Yin, L. I.↗