Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image charge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Charge Transfer Plasmonics in Bespoke Graphene/α-RuCl 3 Cavities

Surface plasmon polaritons (SPPs) provide a window into the nano-optical, electrodynamic response of their host material and its dielectric environment. Graphene/α-RuCl 3 serves as an ideal model system for imaging SPPs since the large work function difference between these two layers facilitates charge transfer that hole dopes graphene with n ~ 10 13 cm –2 free carriers. In this work, we study the emergent THz response of graphene/α-RuCl 3 heterostructures using our home-built cryogenic scanning near-field optical microscope. Using phase-resolved imaging, we clearly observe long wavelength, heavily damped THz SPPs in a series of variable-size graphene cavities. From this, we extract the plasmonic wavelength and scattering rate in the graphene/α-RuCl 3 heterostructures. We determine that the measured plasmon wavelength and electronic scattering rate match our heterostructures’ theoretically predicted values. Here, our results demonstrate that shaping graphene into bespoke cavity structures enables observation and quantification of SPPs in heavily doped graphene that are largely not addressable with other experimental techniques. Moreover, the manifest lack of metallicity observed in the adjacent doped α-RuCl 3 layer provides significant constraints on the nature of the interfacial charge transfer in this 2D heterostructure.

36 MATERIALS SCIENCE↗

Revealing the Nano-Scale Structure and Properties of Pinholes in SiOx Layers for POLO Contacts

In this contribution, we report on the charge collection characteristics of silicon photovoltaic devices with passivated contacts based on the c-Si/SiOx /poly-Si structure. Using electron-beam induced current (EBIC) imaging in plan-view and cross-section orientations, we find that charge collection in a device with a 1.5-nm-thick SiOx layer is fairly uniform in the p-n junction region and does not appear to be influenced by pyramidal surface texture. In contrast, a device with a 2.2-nm-thick oxide layer shows significant spatial variation in the charge-collection signal. The locations where we observe preferential collection of excess carriers is very sensitive to the processing conditions used to grow and breakup the SiOx passivation layer. In some cases the apexes of the pyramids exhibit reduced EBIC signal as the valleys between adjacent pyramids show the strongest collection. Other conditions yield enhanced charge collection at well defined spots on pyramid faces with no observable collection in the valleys.

EBIC↗

Ultrafast structural response to charge redistribution within a photosinthetic reaction centre

This data set contains stream files, difference maps and SVD maps obtained from data processing of time-resolved serial femtosecond crystallography measurements performed at LCLS XFEL, used to construct the images and perform the analysis published in the paper "Ultrafast structural response to charge redistribution within a photosinthetic reaction centre". Two (2) time points plus a dark state from 2015 ('a' label) as well as five (5) time points plus a dark state from 2016 ('b' label) are provided.

CXI↗

Hydroscanner: Instrumentation for Water Ingress Imaging in Photovoltaic Module Packaging Materials

A new iteration of the Hydroscanner prototype was designed and built during the execution of the contract. Compared to the previous designs, the communication port was changed from ethernet to USB C, since it provides a more seamless integration as a peripheral unit. An additional advantage is that one single port can be used for both communication and power up of the infrared camera. Although the power requirements are higher than the typical amount provided by a laptop computer, the camera can be run as a peripheral from a docking station when connected to a thunderbolt charging port. The software interface was modified to accommodate two imaging modes, an 8-bit and 14-bit image display. The 8-bit images use a custom colorization scheme that divides all pixels in the image into bins of equal width, such that images containing a wide range of brightness display the intermediate pixel intensities in greyscale values that enhance the contrast. The 14-bit images provide the direct readout from the focal plane array of the camera and can be saved as a text file for later processing in other software packages (MATLAB, Python).

47 OTHER INSTRUMENTATION↗

Nonuniform Charge Collection in SiOx-Based Passivated-Contact Silicon Solar Cells

In this contribution, we report on the charge-collection characteristics of silicon photovoltaic devices using passivated contacts based on the c-Si/SiO x /poly-Si structure. Using electron-beam induced current (EBIC) imaging in plan-view and cross-section orientations, we find that charge collection in a device with a 1.5-nm-thick SiO x layer is fairly uniform in the p-n junction region and does not appear to be influenced by pyramidal surface texture. In contrast, a device with a 2.2-nm-thick oxide layer shows significant spatial variation in the charge-collection signal. The apexes of the pyramids exhibit reduced EBIC signal whereas the valleys between adjacent pyramids show the strongest collection. Our results indicate that charge collection in c-Si/SiO x /poly-Si structures can be influenced by both the properties of the SiO x layer and surface texture.

14 SOLAR ENERGY↗

Degradation Dynamics of Perovskite Solar Cells Under Fixed Reverse Current Injection

Previous studies of reverse-bias stability in perovskite solar cells have focused primarily on voltage controlled reverse-bias tests. Here we instead present an investigation of perovskite solar cell degradation under well-defined, constant reverse-current stress. We show that the choice of hole-transport layer dictates the dominant degradation pathway: cells using thick poly(triphenylamine) (PTAA) layers with better indium-doped tin oxide (ITO) coverage can tolerate high reverse bias but quickly undergo catastrophic breakdown under fixed reverse current near their one-sun maximum power-point. In contrast, cells modified with the phosphonic-acid interface layer MeO-2PACz, with poorer ITO coverage compared to PTAA, exhibit soft, gradual, and largely recoverable degradation, regardless of the shading conditions. For MeO-2PACz devices, degradation increases with both current magnitude and duration. Importantly, when normalized by injected charge (current times duration), lower currents applied over longer times cause more severe degradation than higher currents over shorter periods. Combining electrical measurements with spatially resolved photoluminescence imaging, we argue against shunt formation and instead support an ion- and charge-mediated interfacial electrochemical degradation mode.

Applied Physics (physics.app-ph)↗

On the redistribution of charge in La 0.7 Sr 0.3 CrO 3 /La 0.7 Sr 0.3 MnO 3 multilayer thin films

The atomic and electronic structures of La 0.7 Sr 0.3 MnO 3 (LSMO)/La 0.7 Sr 0.3 CrO 3 (LSCO) multilayer thin films are investigated using aberration corrected scanning transmission electron microscopy (STEM) imaging and spectroscopy. Atomic resolution high angle annular dark-field reveals that LSMO layers have an expanded out-of-plane lattice parameter compared to compressed LSCO layers, contrasting with x-ray diffraction measurements. The expansion is found to result from preferential oxygen vacancy formation in LSMO during STEM sample preparation as determined by electron energy-loss spectroscopy. The La/Sr atom column intensity is also found to oscillate by about 4% between the LSMO and LSCO layers, indicative of La/Sr concentration variation. Using energy-dispersive x-ray spectroscopy in combination with image simulations, we confirm the La/Sr inhomogeneity and elucidate the origin of charge redistribution within the multilayer. These results illuminate the sensitivity of the technique to subtle structural, chemical, and electronic features that can arise to compensate charge imbalances in complex oxide heterostructures.

36 MATERIALS SCIENCE↗

Transverse Single Spin Asymmetries of Heavy Flavor Electrons and Charged Pions in 200 GeV $p+p^{\uparrow}$ Collisions at Midrapidity

Transverse single spin asymmetries of particles produced in p+p^{\uparrow} p + p ↑ collisions provide insight on the partonic spin and momentum structure of hadrons; heavy flavor electrons provide access to initial state spin-momentum correlations of gluons in the proton, while charged pions provide access to initial and final state transverse spin effects. Charged particles are measured at midrapidity at PHENIX using the silicon vertex detector and central arm spectrometer, made of an electromagnetic calorimeter, a ring-imaging Cherenkov detector, and drift and pad chambers. Recent results for both electron and charged pion measurements from the 2015 running period will be presented.

Fitzgerald, Dillon↗

Atomistic learning in the electronically grand-canonical ensemble

Abstract A strategy is presented for the machine-learning emulation of electronic structure calculations carried out in the electronically grand-canonical ensemble. The approach relies upon a dual-learning scheme, where both the system charge and the system energy are predicted for each image. The scheme is shown to be capable of emulating basic electrochemical reactions at a range of potentials, and coupling it with a bootstrap-ensemble approach gives reasonable estimates of the prediction uncertainty. The method is also demonstrated to accelerate saddle-point searches, and to extrapolate to systems with one to five water layers. We anticipate that this method will allow for larger length- and time-scale simulations necessary for electrochemical simulations.

36 MATERIALS SCIENCE↗

Visualizing the atomic-scale origin of metallic behavior in Kondo insulators

A Kondo lattice is often electrically insulating at low temperatures. However, several recent experiments have detected signatures of bulk metallicity within this Kondo insulating phase. In this study, we visualized the real-space charge landscape within a Kondo lattice with atomic resolution using a scanning tunneling microscope. We discovered nanometer-scale puddles of metallic conduction electrons centered around uranium-site substitutions in the heavy-fermion compound uranium ruthenium silicide (URu 2 Si 2 ) and around samarium-site defects in the topological Kondo insulator samarium hexaboride (SmB 6 ). These defects disturbed the Kondo screening cloud, leaving behind a fingerprint of the metallic parent state. Our results suggest that the three-dimensional quantum oscillations measured in SmB 6 arise from Kondo-lattice defects, although we cannot exclude other explanations. Finally, our imaging technique could enable the development of atomic-scale charge sensors using heavy-fermion probes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tunable tunnel barriers in a semiconductor via ionization of individual atoms

individual adatoms deposited on an InSb(110) surface. The adatoms can be reproducibly dropped off from the STM tip by voltage pulses, and impact tunneling into the surface by up to ~100×. The spatial extent and magnitude of the tunneling effect are widely tunable by imaging conditions such as bias voltage, set current and photoillumination. We attribute the effect to occupation of a (+/0) charge transition level, and switching of the associated adatom-induced band bending. The effect in STM topographic images is well reproduced by transport modeling of filling and emptying rates as a function of the tip position. STM atomic contrast and tunneling spectra are in good agreement with density functional theory calculations for In adatoms. The adatom ionization effect can extend to distances greater than 50 nm away, which we attribute to the low concentration and low binding energy of the residual donors in the undoped InSb crystal. These studies demonstrate how individual atoms can be used to sensitively control current flow in nanoscale devices.

Physics↗

Characterization of a Pixelated Cadmium Telluride Detector System Using a Polychromatic X-Ray Source and Gold Nanoparticle-Loaded Phantoms for Benchtop X-Ray Fluorescence Imaging

In this paper, the imaging dose and scan time have been considered as the two major constraints for routine benchtop x-ray fluorescence computed tomography (XFCT) imaging. One way to address this issue is to acquire x-ray fluorescence (XRF) signals in parallel through a 2D array of single-crystal detectors or a pixelated detector along with the cone-beam x-ray source. To identify a detector system suitable for this purpose, a commercially available, fully spectroscopic cadmium telluride (CdTe) pixelated detector, HEXITEC (High-Energy X-ray Imaging Technology), was tested under the experimental conditions optimized for benchtop XFCT imaging of gold nanoparticles (GNPs). Specifically, two different parallel-hole stainless steel collimators were fabricated and coupled with the detector for seamless integration into our existing benchtop cone-beam XFCT system. After the detector deployment, this benchtop XFCT system was used to detect XRF photons from GNP-loaded phantoms. A pixel-merging algorithm was introduced to enhance the sensitivity of XRF photon detection thereby minimizing the scan time. The effect of pixel-level charge sharing correction algorithms was investigated within the context of benchtop XFCT imaging. The detector energy resolution, in terms of the full width at half maximum (FWHM) values at different gold K-shell XRF energies, was also determined. Of the two charge sharing correction algorithms examined, the charge sharing addition gave better sensitivity than the charge sharing discrimination (csd). On the other hand, under the current experimental conditions, the energy resolution of the HEXITEC detector was the best with the csd and estimated to be 1.56 keV FWHM at 66-69 keV photon energy. Overall, despite some degradation of the detector energy resolution (compared with typical single crystal CdTe detectors), the HEXITEC detector enabled parallel data acquisition under the experimental conditions typical of benchtop XFCT imaging and operated well within our benchtop XFCT setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-amplifier Sensing Charge-coupled Devices for Next Generation Spectroscopy

We present characterization results and performance of a prototype Multiple-Amplifier Sensing (MAS) silicon charge-coupled device (CCD) sensor with 16 channels potentially suitable for faint object astronomical spectroscopy and low-signal, photon-limited imaging. The MAS CCD is designed to reach sub-electron readout noise by repeatedly measuring charge through a line of amplifiers during the serial transfer shifts. Using synchronized readout electronics based on the Dark Energy Spectroscopic Instrument CCD controller, we report a read noise of 1.03 e$^{−}$ rms pix$^{−1}$ at a speed of 26 μs pix$^{−1}$ with a single-sample readout scheme where charge in a pixel is measured only once for each output stage. At these operating parameters, we find the amplifier-to-amplifier charge transfer efficiency (ACTE) to be >0.9995 at low counts for all amplifiers but one for which the ACTE is 0.997. This charge transfer efficiency falls above 50,000 electrons for the read-noise optimized voltage configuration we chose for the serial clocks and gates. The amplifier linearity across a broad dynamic range from ∼300 to 35,000 e$^{−}$ was also measured to be ±2.5%. We describe key operating parameters to optimize on these characteristics and describe the specific applications for which the MAS CCD may be a suitable detector candidate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Halide Perovskites and Their Derivatives for Efficient, High‐Resolution Direct Radiation Detection: Design Strategies and Applications

Abstract The past decade has witnessed a rapid rise in the performance of optoelectronic devices based on lead‐halide perovskites (LHPs). The large mobility‐lifetime products and defect tolerance of these materials, essential for optoelectronics, also make them well‐suited for radiation detectors, especially given the heavy elements present, which is essential for strong X‐ray and γ‐ray attenuation. Over the past decade, LHP thick films, wafers, and single crystals have given rise to direct radiation detectors that have outperformed incumbent technologies in terms of sensitivity (reported values up to 3.5 × 10 6 µC Gy air −1 cm −2 ), limit of detection (directly measured values down to 1.5 nGy air s −1 ), along with competitive energy and imaging resolution at room temperature. At the same time, lead‐free perovskite‐inspired materials (e.g., methylammonium bismuth iodide), which have underperformed in solar cells, have recently matched and, in some areas (e.g., in polarization stability), surpassed the performance of LHP detectors. These advances open up opportunities to achieve devices for safer medical imaging, as well as more effective non‐invasive analysis for security, nuclear safety, or product inspection applications. Herein, the principles behind the rapid rises in performance of LHP and perovskite‐inspired material detectors, and how their properties and performance link with critical applications in non‐invasive diagnostics are discussed. The key strategies to engineer the performance of these materials, and the important challenges to overcome to commercialize these new technologies are also discussed.

36 MATERIALS SCIENCE↗

High spatial resolution neutron imaging of lithium-ion batteries: Correlating microstructure and lithium transport

Thick electrodes for lithium-ion batteries can increase the overall energy density, but increasing the electrode thickness introduces charge transport limitations. These limitations may be mitigated through proper electrode structuring. Here, high spatial resolution neutron imaging was used to understand the correlation between microstructure and lithium transport in lithium-ion anodes. Batteries with distinct graphite anode microstructures were produced and studied with high spatial resolution in operando neutron radiography to observe the effects of structure on transport. High spatial resolution neutron computed tomography was performed following in operando neutron radiography. X-ray computed tomography and scanning electron microscopy were used to observe the finer scale anode structure to complement neutron imaging. Solvent-free anodes containing a tightly-packed layered structure confined lithium movement close to the separator. This structure limited capacity, but supported better rate capability. Conversely, a more open pore structure in the wet cast anodes yielded higher capacity with reduced rate capability. Together, these results show that lithium distributions can be controlled by the macroscopic structure of the electrodes, the microstructural pore network, and the microscale active areas that support electrochemical reactions. Furthermore, multimodal imaging applying the complementary strengths of neutron and X-ray methods is shown as a tool for advancing battery design.

25 ENERGY STORAGE↗

Imaging hole-density inhomogeneity in arsenic-doped CdTe thin films by scanning capacitance microscopy

We report nanometer-scale hole-density imaging in As-doped CdTe films by scanning capacitance microscopy (SCM). The hole-density profiling is validated by contrasting a CdTe cross-section sample made by molecular-beam epitaxy with systematically increased As doping in a staircase pattern over the range of 10 15 -10 18 /cm 3 within a single film. In polycrystalline films, the carrier distribution is significantly nonuniform, with inhomogeneity ranging from several hundred nm to several um and hole density varying by one order of magnitude (low 10^16 to low 10 17 /cm 3 ). This nonuniformity is distributed randomly, independent of the grain structure and grain boundaries (GBs). Kelvin probe force microscopy (KPFM) maps the surface potential and is correlated to cathodoluminescence (CL) and SCM by imaging over identical areas. Higher potential and lower CL intensity are found on GBs but not by SCM contrast; this indicates positive GB charging and recombination, but not GB-specific hole-density changes. The overall KPFM potential image is in rough agreement with the SCM carrier distribution and indicates band-edge potential fluctuations. Nonuniform carrier concentration, potential fluctuations, and defect recombination can all cause voltage and performance loss in As-doped CdTe solar technology.

14 SOLAR ENERGY↗

Multiscale dynamics of charging and plating in graphite electrodes coupling operando microscopy and phase-field modelling

The phase separation dynamics in graphitic anodes significantly affects lithium plating propensity, which is the major degradation mechanism that impairs the safety and fast charge capabilities of automotive lithium-ion batteries. In this study, we present comprehensive investigation employing operando high-resolution optical microscopy combined with non-equilibrium thermodynamics implemented in a multi-dimensional (1D+1D to 3D) phase-field modeling framework to reveal the rate-dependent spatial dynamics of phase separation and plating in graphite electrodes. Here we visualize and provide mechanistic understanding of the multistage phase separation, plating, inter/intra-particle lithium exchange and plated lithium back-intercalation phenomena. A strong dependence of intra-particle lithiation heterogeneity on the particle size, shape, orientation, surface condition and C-rate at the particle level is observed, which leads to early onset of plating spatially resolved by a 3D image-based phase-field model. Moreover, we highlight the distinct relaxation processes at different state-of-charges (SOCs), wherein thermodynamically unstable graphite particles undergo a drastic intra-particle lithium redistribution and inter-particle lithium exchange at intermediate SOCs, whereas the electrode equilibrates much slower at low and high SOCs. These physics-based insights into the distinct SOC-dependent relaxation efficiency provide new perspective towards developing advanced fast charge protocols to suppress plating and shorten the constant voltage regime.

25 ENERGY STORAGE↗

Plasma temperature measurement with a silicon photomultiplier (SiPM)

The temperature of a nonneutral plasma confined in a Penning–Malmberg trap can be determined by slowly lowering one side of the trap’s electrostatic axial confinement barrier; the temperature is inferred from the rate at which particles escape the trap as a function of the barrier height. In many experiments, the escaping particles are directed toward a microchannel plate, and the resulting amplified charge is collected on a phosphor screen. The screen is used for imaging the plasma but can also be used as a Faraday cup (FC) for a temperature measurement. The sensitivity limit is then set by microphonic noise enhanced by the screen’s high-voltage bias. Alternately, a silicon photomultiplier (SiPM) can be employed to measure the charge via the light emitted from the phosphor screen. This decouples the signal from the microphonic noise and allows the temperature of colder and smaller plasmas to be measured than could be measured previously; this paper focuses on the advantages of a SiPM over a FC.

Hunter, E. D. (ORCID:0000000236242840)↗