Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high field sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Signatures of cosmic-ray interactions on the solar surface

The fluxes of neutrinos, gamma rays, antiprotons, neutrons, and antineutrons that result from collisions of high-energy Galactic cosmic rays with the solar atmosphere are estimated. The results are sensitive to assumptions about cosmic-ray transport in the magnetic fields of the inner solar system. The high-energy photon flux should be observable by the Gamma Ray Observatory. The neutrino flux should produce less than one event per year in the next generation of neutrino telescopes. The antiproton flux is unobservable against the Galactic background. The neutron and antineutron fluxes are detectable only if neutrons produced in terrestrial cosmic-ray events may be discriminated against.

Seckel, D.↗

Characteristics and selection of near-fault simulated earthquake ground motions for nonlinear analysis of buildings

Earthquake-induced ground shaking near rupturing faults is highly sensitive to the rupture characteristics, seismic wave propagation patterns and site conditions, and field recordings of near-fault shaking are relatively sparse. These challenges complicate the assessment of the seismic performance of near-fault structures. A common approach to representing near-fault ground motion in engineering analysis is to explicitly consider and select records with strong directivity pulses (pulse records). We use three-dimensional high-resolution physics-based earthquake simulations to test this approach in the context of scenario-based ground motion record selection, and to study the important characteristics of near-fault ground shaking. We highlight the deficiencies associated with classifying near-fault simulated records as “pulse” or “non-pulse,” based on the presence of a single dominating pulse in the velocity time history. We show that this approach is inadequate for characterizing near-fault shaking on soft soils which can be dominated by both forward rupture directivity and basin amplification effects. We conduct ground motion selection experiments for the analysis of near-fault structures with and without explicit classification of the pulse features in the records, and evaluate the bias in the predicted structural demands. We find that the maximum interstory drift demands on building structures imposed by unscaled site-specific simulated ground motion records selected based on relevant spectral shape features are not sensitive to the classification of records as pulse/non-pulse. Therefore, with regard to predicting the maximum interstory drifts in near-fault buildings, we do not find justification for the binary pulse classification of near-fault records.

42 ENGINEERING↗

Relative sensitivity of plastic scintillator: A comparative analysis with 60 Co gamma rays, deuterium–deuterium, and deuterium–tritium neutrons

A plastic scintillator has found extensive application in the realm of high-energy physics and national security science. Many applications in those fields often involve the simultaneous production of photons, neutrons, and charged particles, which makes the relative sensitivity information for these different radiation types important. In this study, we have adopted a multi-head detector comprised of a plastic scintillator and high gain phototubes, which provides a large dynamic range and linearity. A comparative study on the relative sensitivities of plastic scintillators was facilitated by adopting three distinct radiation calibration sources (i.e., 60 Co γ rays, DD neutrons, and DT neutrons). Neutrons from a DD source generate a comparable level of scintillation to gamma rays emitted by 60 Co (i.e., 60 Co-γ/DD-n = 0.92 ± 16%). DT neutrons induce ~3.5 times the scintillation observed with DD neutrons (i.e., DT-n/DD-n = 3.5 ± 28%). In addition, the Geant4 simulation granted us valuable insights into the relative sensitivity of the scintillator. This comparative study will provide a useful database for users in diverse applications.

47 OTHER INSTRUMENTATION↗

Airborne Spectral Measurements of Ocean Directional Reflectance

During summer of 2001 NASA's Cloud Absorption Radiometer (CAR) obtained measurement of ocean angular distribution of reflected radiation or BRDF (bidirectional reflectance distribution function) aboard the University of Washington Convair CV-580 research aircraft under cloud-free conditions. The measurements took place aver the Atlantic Ocean off the eastern seaboard of the U.S. in the vicinity of the Chesapeake Light Tower and at nearby National Oceanic and Atmospheric Administration (NOAA) Buoy Stations. The measurements were in support of CLAMS, Chesapeake Lighthouse and Aircraft Measurements for Satellites, field campaign that was primarily designed to validate and improve NASA's Earth Observing System (EOS) satellite data products being derived from three sensors: MODIS (MODerate Resolution Imaging Spectro-Radiometer), MISR (Multi-angle Imaging Spectro-Radiometer) and CERES (Clouds and Earth s Radiant Energy System). Because of the high resolution of the CAR measurements and its high sensitivity to detect weak ocean signals against a noisy background, results of radiance field above the ocean are seen in unprecedented detail. The study also attempts to validate the widely used Cox-Munk model for predicting reflectance from a rough ocean surface.

Gatebe, Charles K.↗

A small helium-cooled infrared telescope for Spacelab 2

A helium cooled telescope of 15 cm aperture is being designed and constructed jointly by the University of Arizona, the Smithsonian Astrophysical Observatory and the Marshall Space Flight Center for high sensitivity infrared astronomical observations from Spacelab 2. A focal plane array of ten detectors provide a total field of view of 3 deg and cover the wavelength regions 4.5-8.5, 6-7, 9-16, 18-30 and 80-120 microns. A highly redundant all sky survey will be conducted by repeated scanning of the sky during many orbits of the spacecraft. High redundancy will allow discrimination among variable and constant celestial sources and several types of variable nearby sources. The principal astronomical result of the survey will be the absolute flux measurement of low surface brightness, large scale celestial infrared emissions but it will also extend existing IR sky surveys by a factor of 10 in point source sensitivity. The experiment will also make significant engineering measurements of contaminants in the Shuttle environment, test the technology of storage and utilization of large quantities of superfluid helium in space and test mechanical designs for future infrared telescopes for the Space Shuttle.

Gautier, T. N., III↗

Modeling of surface-state induced inter-electrode isolation of n -on- p devices in mixed-field and γ -irradiation environments

Position sensitive n-on-p silicon sensors will be utilized in the tracker and in the High Granularity Calorimeter (HGCAL) of the Compact Muon Solenoid (CMS) experiment at High Luminosity Large Hadron Collider (HL-LHC). The detrimental effect of the radiation-induced accumulation of positive net oxide charge on position resolution in n-on-p sensors has typically been countered by the application of isolation implants like p-stop or p-spray between n + -electrodes. In addition to the positively charged layer inside the oxide and close to the Si/SiO 2 -interface, surface damage introduced by ionizing radiation in SiO 2 -passivated silicon particle detectors includes the accumulation of trapped-oxide-charge and interface traps. A previous study of either n/γ (mixed field)- or γ-irradiated Metal-Oxide-Semiconductor (MOS) capacitors showed evidence of substantially higher introduction rates of acceptor- and donor-type deep interface traps (N it,acc/don ) in mixed-field environment. Here, in this work, an inter-pad and -strip resistance (or resistivity (ρ int )) simulation study of n-on-p sensors with and without p-stop isolation implants was conducted for both irradiation types. Higher levels of ρint showed correlation to higher densities of deep N it,acc/don , with the inter-pad isolation performance of the mixed-field irradiated sensors becoming independent of the presence of p-stop implant between the n + - electrodes up to about 100 kGy. The low introduction rates of deep N it,acc/don in γ-irradiated sensors resulted in high sensitivity of ρ int to the presence and peak doping of p-stop above the lowest dose of about 7 kGy in the study. As a consequence of the advantageous influence of radiation-induced accumulation of deep N it on the inter-electrode isolation, position sensitive n-on-p sensors without isolation implants may be considered for future HEP-experiments where the radiation is largely due to hadrons.

Akchurin, N. [Texas Tech Univ., Lubbock, TX (Unite↗

Rate-dependent strength and deformation heterogeneity of B4C-reinforced Al composite: Time-resolved imaging with synchrotron X-rays

Dynamic (up to 5500 s -1 ) and quasi-static compression tests are conducted on a 15 wt% B4C particle-reinforced Al (B 4 C/Al) composite. In situ, high-speed synchrotron X-ray phase contrast imaging and digital image correlation are employed to map mesoscale deformation fields at μm and μs scales. The bulk stress–strain curves show significant strain and strain-rate hardening under dynamic compression. The strain-rate sensitivity exponent is an order of magnitude higher at high strain rates (> 10 3 s -1 ) than that at low strain rates (< 10 -2 s -1 ). Strain field mapping demonstrates distinct compressive strain localizations for both quasi-static and dynamic loading. Nevertheless, compressive strain localizations appear denser in spacing under dynamic loading, owing to spontaneous dislocation nucleation in both weak and strong zones. This results in a higher density of geometrically necessary dislocations, which contributes to the higher strain and strain-rate hardening of B 4 C/Al under dynamic loading. Additionally, the ratio of the maximum local strain to the bulk average is 1.5, and the local strain-rate enhancement cannot explain the increased rate sensitivity of B 4 C/Al under dynamic loading. Therefore, the rate-dependent deformation heterogeneity dominates the strain-rate hardening of B 4 C/Al. Postmortem analyses help correlate deformation features to particle- and grain-scale microstructures, yielding consistent results with mesoscale strain fields.

36 MATERIALS SCIENCE↗

Resonant torque differential magnetometry with high frequency quartz oscillators

Sensitive magnetometry has been a powerful probe for investigating quantum materials. Extreme conditions, such as sub-kelvin cryogenic temperatures and ultrahigh magnetic fields, demand further durability for sensitive magnetometry. However, significant mechanical vibrations and rapid magnetic field changes give enormous challenges to conventional magnetometry. Here, this article presents a possible solution to this problem by developing a new magnetometry technique using high-frequency quartz oscillators. The technique takes advantage of the symmetry and geometry of mechanical vibration configurations of standard commercially available MHz quartz oscillators, and the setup keeps the high quality factor resonance with the sample mounted on the oscillator. We further demonstrate the sensitivity of the technique using bismuth single crystals and a Fe 0.25 TaS 2 ferromagnetic material. Quantum oscillations are observed in the magnetometry response below 1 T, and the detected oscillation frequency is shown to come from the electron pockets of the bismuth.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Piezoelectric bulk acoustic resonators for dark photon detection

The kinetically mixed dark photon is a simple, testable dark matter candidate with strong theoretical motivation. Detecting the feeble electric field dark photon dark matter produces requires extremely sensitive detectors. Bulk acoustic resonators (BARs), with their exceptionally high-quality phonon modes, are highly sensitive detectors, and have previously leveraged this sensitivity to search for gravitational waves in the MHz to GHz frequency range. The BAR phonons are typically read out by detecting the electric field generated by the BAR materials’ piezoelectricity. Here we show that this piezoelectricity also rewards such detectors sensitivity to dark photon dark matter, as the dark electric field can resonantly excite BAR phonons. A single 10 g piezoelectric BAR in a large, cold, environment can be orders of magnitude more sensitive to the kinetic mixing parameter than any current experiment, with only a month-long exposure and thermally limited backgrounds.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetometry in a diamond anvil cell using nitrogen vacancy centers in a nanodiamond ensemble

The emerging field of optical magnetometry utilizing negative-charged nitrogen vacancy (NV – ) centers provides a highly sensitive lab bench technique for spatially resolved physical property measurements. Their implementation in high pressure diamond anvil cell (DAC) environments will become common as other techniques are often limited due to the spatial constraints of the sample chamber. Apparatus and techniques are described here permitting for more general use of magnetic field measurements inside a DAC using continuous wave optical detected magnetic resonance in NV – centers in a layer of nanodiamonds. A microstrip antenna delivers a uniform microwave field to the DAC and is compatible with simple metal gaskets, and the sensor layer of deposited nanodiamonds allows for simple determination of the magnetic field magnitude for B in the 1–100 G range. The ferromagnetic transition in iron at 18 GPa is measured with the apparatus, along with its hysteretic response.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In-Flight Performance of the Polarization Modulator in the CLASP Rocket Experiment

We developed a polarization modulation unit (PMU), a motor system to rotate a waveplate continuously. We applied this PMU for the Chromospheric Lyman-alpha SpectroPolarimeter (CLASP), a sounding rocket experiment to observe the linear polarization of the Lyman-alpha emission (121.6 nm vacuum ultraviolet) from the upper chromosphere and transition region of the Sun with a high polarization sensitivity of 0.1% for the first time and investigate the vector magnetic field. Rotation non-uniformity of the waveplate causes error in the polarization degree (i.e. scale error) and crosstalk between Stokes components. In the ground tests, we confirmed that PMU has superior rotation uniformity. CLASP was successfully launched on September 3, 2015, and PMU functioned well as designed. PMU achieved a good rotation uniformity during the flight and the high precision polarization measurement of CLASP was successfully achieved.

CLASP↗

Clumping index estimation with 30°-tilted cameras in row crops: Evaluation of methods and segment size effects

The clumping index (CI) quantifies the spatial distribution of foliage elements and is essential for accurately estimating the plant area index (PAI), canopy radiative transfer, and photosynthesis. Traditionally, the finite-length averaging method (LX), the gap size distribution method (CC), and a combined approach of CC and LX (CLX) have been applied to instruments like TRAC and digital hemispherical photography to estimate CI. However, a comprehensive evaluation of these methods in row crops remains limited, especially regarding the influence of segment size on CI. Meanwhile, digital cameras offer a cost-effective and user-friendly solution for canopy measurements in row crops, yet their application in this context remains underexplored. In this study, we employed a new approach using a 30°-tilted digital camera to estimate CI in corn and soybean fields, applying the LX, CC, and CLX methods. We systematically assessed the performance of these three methods by combining field measurements in real-world fields with simulations using the LESS 3D radiative transfer model. Our results showed that CLX applied to the whole image and 45° segment offered accurate estimation of CI (bias within ±0.1, RMSE < 0.2) and PAI (bias within ±0.4, RMSE < 1) in real-world fields and LESS simulations. The accuracy of the LX method was highly sensitive to segment size, with the best performance observed at the 15° segment (PAI bias within ±0.4). In contrast, the CC method remained stable across different segment sizes, and its performance was generally comparable to that of LX, except at the 15° segment. Across view zenith angles, CI derived from CC generally showed a continuous increase, while those from LX and CLX followed a rising trend at small zenith angles but began to decline at 68°, likely due to an increasing proportion of no-gap segments. Seasonally, LX tended to show decreasing CI during early growth stages but increased as the canopy matured, whereas CC and CLX showed gradually increasing CI before plateauing at peak PAI. The 30°-tilted camera effectively captured CI variations across different angles and growth stages, making it a practical and robust instrument for row crop canopy structure analysis. Furthermore, applying these CI methods to digital cameras offers a low-cost and accessible CI estimation alternative, improving canopy structure monitoring accuracy in row crops.

30°-tilted camera↗

High- Q Microwave Dielectric Resonator for Axion Dark-Matter Haloscopes

The frequency band 1–15 GHz provides exciting prospects for resonant axion haloscopes as indicated by cosmological and astrophysical arguments. Among the challenges currently addressed to reach the required sensitivity, the development of high-quality factor cavities that tolerate multitesla fields plays a central role. We report a three-dimensional resonator based on a right-circular copper cavity with hollow cylinders that confine higher-order modes around the cylinder axis. Its effective volume at 10.3 GHz is 3.4 × 10 − 2 l, and under an 8-T field we measure an internal quality factor of more than nine million. A fine-tuning system limited to approximately 1 -MHz range is tested, useful for understanding the conditions required to run a haloscope with a cavity exceeding the axion quality factor. The cavity parameters we report demonstrate the potential of this unique resonator to probe galactic dark-matter axion at scan rates exceeding 2 MHz/day when the cavity is readout by a quantum-limited receiver.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Zero-crosstalk silicon photonic refractive index sensor with subwavelength gratings

Abstract Silicon photonic index sensors have received significant attention for label-free bio and gas-sensing applications, offering cost-effective and scalable solutions. Here, we introduce an ultra-compact silicon photonic refractive index sensor that leverages zero-crosstalk singularity responses enabled by subwavelength gratings. The subwavelength gratings are precisely engineered to achieve an anisotropic perturbation-led zero-crosstalk, resulting in a single transmission dip singularity in the spectrum that is independent of device length. The sensor is optimized for the transverse magnetic mode operation, where the subwavelength gratings are arranged perpendicular to the propagation direction to support a leaky-like mode and maximize the evanescent field interaction with the analyte space. Experimental results demonstrate a high wavelength sensitivity of − 410 nm/RIU and an intensity sensitivity of 395 dB/RIU, with a compact device footprint of approximately 82.8 μm 2 . Distinct from other resonant and interferometric sensors, our approach provides an FSR-free single-dip spectral response on a small device footprint, overcoming common challenges faced by traditional sensors, such as signal/phase ambiguity, sensitivity fading, limited detection range, and the necessity for large device footprints. This makes our sensor ideal for simplified intensity interrogation. The proposed sensor holds promise for a range of on-chip refractive index sensing applications, from gas to biochemical detection, representing a significant step towards efficient and miniaturized photonic sensing solutions. Graphical Abstract

Materials Science↗

Exploring New Diamond Surfaces with Precision Chemistry and Quantum Spectroscopy

Point defects in diamond known as color centers are a promising platform for quantum sensing. As atom-like systems, they can exhibit excellent spin coherence and can be manipulated with light. As solid-state defects, they can be produced at high densities and be incorporated into scalable devices. Diamond is a uniquely excellent host; it has a large band gap, can be synthesized with sub-ppb impurity concentrations, and can be isotopically purified to eliminate magnetic noise from nuclear spins. Specifically, the nitrogen vacancy (NV) center has been demonstrated to be a highly sensitive, non-invasive magnetic probe capable of resolving the magnetic field of a single electron spin with nanometer spatial resolution. However, the development of NV centers and other color centers in diamond as a quantum platform crucially relies on developing methods to functionalize and process diamond surfaces. Diamond is the hardest material, making polishing and processing challenging, and diamond surfaces are inert and sterically hindered, making them notoriously difficult to chemically terminate and functionalize. Our approach is to discover new surface chemistries for diamond by combining multimodal surface spectroscopy with NV-based quantum spectroscopy to carefully characterize the diamond surface. We have developed a suite of techniques for characterizing the diamond surface using rapid tools for reaction screening and detailed surface spectroscopy tools for definitive identification of the surface bonding.

36 MATERIALS SCIENCE↗

Detector arrays for photometric measurements at soft X-ray, ultraviolet and visible wavelengths

The construction and modes of operation of the Multi-Anode Microchannel Array (MAMA) detectors are described, and the designs of spectrometers utilizing them are outlined. MAMA consists of a curved microchannel array plate, an opaque photocathode (peak quantum efficiency of 19% at 1216 A), and a multi-anode (either discrete- or coincidence-anode) readout array. Designed for use in instruments on spaceborne telescopes, MAMA can be operated in a windowless configuration in extreme-ultraviolet and soft X-ray wavelengths, or in a sealed configuration at UV and visible wavelengths. Advantages of MAMA include low applied potential (less than 3.0 kV), high gain (greater than 10 to the 6th electrons/pulse), low sensitivity to high-energy charged particles, and immunity to external magnetic fields of less than 500 Gauss

Timothy, J. G.↗

Study of the effects of impurities on the properties of silicon materials and performance of silicon solar cell

The effect of silicon film thickness on the energy conversion efficiency of a back surface field solar cell is investigated. A computer-aided design study on the dependence of efficiency peaks on the concentrations of the recombination and dopant impurities is presented. The illuminated current voltage characteristics of over 100 cell designs were obtained using the transmission line circuit model to numerically solve the Shockley Equations. Using an AM1 efficiency of 17% as a target value, it is shown that the efficiency versus thickness dependence has a broad maximum which varies less than 1% over more than three-to-one range of cell thickness from 30 to 100 microns. Optical reflecting back surface will give only a slight improvement of AM1 efficiency, about 0.7%, in this thickness range. The sensitive dependence of efficiency on patchiness across the back surface field, low high junction in thin cells is noted.

Sah, C. T.↗

The interstellar carbon abundance. II - Rho Ophiuchi and Beta Scorpii

A procedure designed to obtain increased sensitivity from high-dispersion IUE spectra by using a flat-field spectrum to remove nonrandom noise due to the response pattern of the SEC vidicon detector is described. Application of this procedure to spectra of Rho Oph and Beta(1) Sco near the spin-forbidden interstellar 2325 line of C II yields 2 sigma upper limits on absorption of W (lambda) not greater than about 4 mA. The resulting depletion of carbon from the interstellar gas toward Rho Oph exceeds a factor of 1.4.

Welty, D. E.↗