Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating and cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Solar heating and cooling system installed at RKL Controls Company, Lumberton, New Jersey

The final results of the design and operation of a computer controlled solar heated and cooled 40,000 square foot manufacturing building, sales office, and computer control center/display room are summarized. The system description, test data, major problems and resolutions, performance, operation and maintenance manual, equipment manufacturers' literature, and as-built drawings are presented. The solar system is composed of 6,000 square feet of flat plate collectors, external above ground storage subsystem, controls, absorption chiller, heat recovery, and a cooling tower.

Source record↗

The design of a solar energy collection system to augment heating and cooling for a commercial office building

Analytical studies supported by experimental testing indicate that solar energy can be utilized to heat and cool commercial buildings. In a 50,000 square foot one-story office building at the Langley Research Center, 15,000 square feet of solar collectors are designed to provide the energy required to supply 79 percent of the building heating needs and 52 percent of its cooling needs. The experience gained from the space program is providing the technology base for this project. Included are some of the analytical studies made to make the building design changes necessary to utilize solar energy, the basic solar collector design, collector efficiencies, and the integrated system design.

Basford, R. C.↗

Prototype solar heating and cooling systems including potable hot water

Progress is reviewed in the development, delivery, and support of two prototype solar heating and cooling systems including potable hot water. The system consisted of the following subsystems: collector, auxiliary heating, potable hot water, storage, control, transport, and government-furnished site data acquisition.

Source record↗

Use of cooling air heat exchangers as replacements for hot section strategic materials

Because of financial and political constraints, strategic aerospace materials required for the hot section of future engines might be in short supply. As an alternative to these strategic materials, this study examines the use of a cooling air heat exchanger in combination with less advanced hot section materials. Cycle calculations are presented for future turbofan systems with overall pressure ratios to 65, bypass ratios near 13, and combustor exit temperatures to 3260 R. These calculations quantify the effect on TSFC of using a decreased materials technology in a turbofan system. The calculations show that the cooling air heat exchanger enables the feasibility of these engines.

Gauntner, J. W.↗

Use of cooling air heat exchangers as replacements for hot section strategic materials

Because of financial and political constraints, strategic aerospace materials required for the hot section of future engines might be in short supply. As an alternative to these strategic materials, this study examines the use of a cooling air heat exchanger in combination with less advanced hot section materials. Cycle calculations are presented for future turbofan systems with overall pressure ratios to 65, bypass ratios near 13, and combustor exit temperatures to 3260 R. These calculations quantify the effect on TSFC of using a decreased materials technology in a turbofan system. The calculations show that the cooling air heat exchanger enables the feasibility of these engines. Previously announced in STAR as N83-34946

Gauntner, J. W.↗

Heat transfer and core neutronics considerations of the heat pipe cooled thermionic reactor

The authors summarize the results of detailed neutronic and thermal-hydraulic evaluations of the heat pipe cooled thermionic (HPTI) reactor design, identify its key design attributes, and quantify its performance characteristics. The HPTI core uses modular, liquid-metal core heat transfer assemblies to replace the liquid-metal heat transport loop employed by in-core thermionic reactor designs of the past. The nuclear fuel, power conversion, heat transport, and heat rejection functions are all combined into a single modular unit. The reactor/converter assembly uses UN fuel pins to obtain a critical core configuration with in-core safety rods and reflector controls added to complete the subassembly. By thermally bonding the core heat transfer assemblies during the reactor core is coupled neutronically, thermally, and electrically into a modular assembly of individual power sources with cross-tied architecture. A forward-facing heat pipe radiator assembly extends from the reactor head in the shape of a frustum of a cone on the opposite side of the power system from the payload. Important virtues of the concept are the absence of any single-point failures and the ability of the core to effectively transfer the TFE waste heat load laterally to other in-core heat transfer assemblies in the event of multiple failures in either in-core and radiator heat pipes.

Determan, W. R.↗

Problems encountered in solar heating and cooling systems

Report discussing various experiences of workers at Marshall Space Flight Center in developing solar heating and cooling systems is presented. Presents compilation of problems and their resolutions which can assist designers of solar-energy systems and prevent repetition of errors.

Cash, M.↗

Central Data Processing System (CDPS) user's manual: Solar heating and cooling program

The software and data base management system required to assess the performance of solar heating and cooling systems installed at multiple sites is presented. The instrumentation data associated with these systems is collected, processed, and presented in a form which supported continuity of performance evaluation across all applications. The CDPS consisted of three major elements: communication interface computer, central data processing computer, and performance evaluation data base. Users of the performance data base were identified, and procedures for operation, and guidelines for software maintenance were outlined. The manual also defined the output capabilities of the CDPS in support of external users of the system.

Source record↗

Heat pipe cooling of power processing magnetics

The constant demand for increased power and reduced mass has raised the internal temperature of conventionally cooled power magnetics toward the upper limit of acceptability. The conflicting demands of electrical isolation, mechanical integrity, and thermal conductivity preclude significant further advancements using conventional approaches. However, the size and mass of multikilowatt power processing systems may be further reduced by the incorporation of heat pipe cooling directly into the power magnetics. Additionally, by maintaining lower more constant temperatures, the life and reliability of the magnetic devices will be improved. A heat pipe cooled transformer and input filter have been developed for the 2.4 kW beam supply of a 30-cm ion thruster system. This development yielded a mass reduction of 40% (1.76 kg) and lower mean winding temperature (20 C lower). While these improvements are significant, preliminary designs predict even greater benefits to be realized at higher power. This paper presents the design details along with the results of thermal vacuum operation and the component performance in a 3 kW breadboard power processor.

Hansen, I. G.↗

Temperature distribution of a hot water storage tank in a simulated solar heating and cooling system

A 2,300-liter hot water storage tank was studied under conditions simulating a solar heating and cooling system. The initial condition of the tank, ranging from 37 C at the bottom to 94 C at the top, represented a condition midway through the start-up period of the system. During the five-day test period, the water in the tank gradually rose in temperature but in a manner that diminished its temperature stratification. Stratification was found not to be an important factor in the operation of the particular solar system studied.

Namkoong, D.↗

Prototype solar heating and cooling systems

A collection of monthly status reports are given on the development of eight prototype solar heating and cooling systems. This effort calls for the development, manufacturing, test, system installation, maintenance, problem resolution, and performance evaluation. The systems are 3-, 25-, and 75-ton size units.

Source record↗

Optimization of a heat-pipe-cooled space radiator for use with a reactor-powered Stirling engine

The design optimization of a reactor-Stirling heat-pipe-cooled radiator is presented. The radiator is a self-deploying concept that uses individual finned heat pipe 'petals' to reject waste heat from a Stirling engine. Radiator optimization methodology is presented, and the results of a parametric analysis of the radiator design variables for a 100-kW(e) system are given. The additional steps of optiminzing the radiator resulted in a net system mass savings of 3 percent.

Moriarty, Michael P.↗

Solar-Heated and Cooled Office Building--Columbus, Ohio

Final report documents solar-energy system installed in office building to provide space heating, space cooling and domestic hot water. Collectors mounted on roof track Sun and concentrate rays on fluid-circulating tubes. Collected energy is distributed to hot-water-fired absorption chiller and space-heating and domestic-hot-water preheating systems.

Source record↗

A method to generate heating and cooling schedules based on data from connected thermostats

Internet-connected thermostats are a promising new source of temperature and operational data in homes because they record inside temperatures, setpoints, and HVAC runtimes every five minutes. Over 20 million Internet-connected thermostats have already been installed in American homes. Data from about 20,000 connected thermostats were collected and organized by climate zone, number of occupants, floor area, and day type. A method was developed to create up to 40 representative temperature schedules which, together, can more accurately capture the diversity of heating and cooling behaviors. These results are suitable for input into schedules for building energy simulation models. This information enables more realistic simulations of American heating and cooling behavior, leading to more accurate estimates of energy consumption and savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Estimating Future Changes of Energy Demand for Heating and Cooling Buildings at NASA Centers GC23J-1198

With its unique and trusted earth observations, NASA is a critical source in informing decisions that will help achieve the U.S. goal of Net-Zero Greenhouse Gas (GHG) Emissions by 2050. NASA’s Prediction of Worldwide Energy Resource (POWER) project facilitates the use of NASA Earth Science data holdings within the energy, agricultural, and building heating/cooling design industries. POWER packages solar and meteorological data from several NASA projects in a user friendly GIS-enabled web services system (https://power.larc.nasa.gov). As part of the development of new data products to support the energy and building heating/cooling design communities, we estimate the changes in energy required to heat and cool buildings in the future climate at 14 different NASA site locations spread throughout the continental United States, as projected by CMIP6 climate models under different emissions scenarios. Bias-corrected downscaled time series of meteorological variables are taken from NASA Earth Exchange (NEX) Global Daily Downscaled Projections (GDDP-CMIP6) downscaled climate model data. The spread between the different model projections is accounted for by analyzing both the ensemble average of 22 CMIP6 models and 6 representative models with different climate sensitivities and different interannual variability. Changes in energy use are estimated in two ways. First, changes in the total annual heating and cooling degree days (HDD and CDD, respectively) are calculated relative to the current climate. This is done at all 14 sites. Second, the downscaled time series are used as inputs into RETScreen(R), a clean energy management decision tool, to give an estimate of heating/cooling energy use for a typical office building. We use this estimation method with model data at Langley Research Center. In the next 50 years, the annual total of HDD (CDD) is projected to decrease by 8-38% (increase by 5-28%) at all sites, with the increase in CDD typically a larger magnitude the decrease in HDD. For a typical small office building at Langley Research Center, the amount of energy needed to cool increases by 33-54% and the amount of energy to heat decreases by 29-40%. POWER is working to develop long term climate data services based on these results to include in future data products to provide to users.

Bradley M. Hegyi↗

Solar heating and cooling technical data and systems analysis

The research activities described herein were concentrated on the areas of economics, heating and cooling systems, architectural design, materials characteristics, climatic conditions, educational information packages, and evaluation of solar energy systems and components.

Christensen, D. L.↗

Some calculations bearing on the heating and cooling of quiescent prominences

The evolution of heat along and perpendicular to magnetic fields threading quiescent prominences is discussed. It was shown that while heating of prominence material can occur on a time scale of the order of 1000's, individual flux tubes are effectively thermally insulated from neighboring tubes, since the transverse heat conduction time scale is of the order of 10000 per year. The exact solution to the one-dimensional parallel heat conduction problem is shown to differ significantly from the approximate solution of Ioshpa (1965). It was suggested that uneven heating of a quiescent prominence by the surrounding solar corona may contribute to surges and/or the 'winking' phenomenon recorded in many quiescent prominences. The signature of such a temperature pulse would be a sharp brightening of continuum radiation with a correlated decrease in the free-bound emission, followed by a slow recovery of both to their pre-heat pulse levels.

Lerche, I.↗