Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A study of high-temperature heat pipes with multiple heat sources and sinks. I - Experimental methodology and frozen startup profiles. II - Analysis of continuum transient and steady-state experimental data with numerical predictions

Experimental profiles for heat pipe startup from the frozen state were obtained, using a high-temperature sodium/stainless steel pipe with multiple heat sources and sinks to investigate the startup behavior of the heat pipe for various heat loads and input locations, with both low and high heat rejection rates at the condensor. The experimental results of the performance characteristics for the continuum transient and steady-state operation of the heat pipe were analyzed, and the performance limits for operation with varying heat fluxes and location are determined.

Faghri, A.↗

Response of a stably stratified atmosphere to low-level heating - An application to the heat island problem

Two-dimensional airflow characteristics past a heat island are investigated using both a linear analytic model and a nonlinear numerical model in the context of the response of a stably stratified atmosphere to specified low-level heating in a constant shear flow. Results from the steady-state, linear, analytic solutions exhibit typical flow response fields that gravity waves produce in response to the local heat source in the presence of environmental flow. The magnitude of the perturbation vertical velocity is shown to be much larger in the shear-flow case than in the uniform-flow case. Two distinct flow features are observed for larger heating amplitude (hence, larger nonlinearity factor): the gravity-wave-type response field on the upstream side of the heat island and the strong updraft circulation cell located on the downstream side. As the heating amplitude increases, the updraft circulation cell strengthens and shifts farther downwind. The strong updraft cell is believed to be partly responsible for precipitation enhancement observed on the downstream side of the heat island. It is found that the continuing downwind propagation of the updraft circulation cell is related to basic-state wind speed.

Baik, Jong-Jin↗

Heat transfer in thin, compact heat exchangers with circular, rectangular, or pin-fin flow passages

Heat transfer and pressure drop have been measured of three thin, compact heat exchangers in helium gas at 3.5 MPa and higher, with Reynolds numbers of 450 to 36,000. The flow geometries for the three heat exchanger specimens were: circular tube, rectangular channel, and staggered pin fin with tapered pins. The specimens were heated radiatively at heat fluxes up to 77 W/sq cm. Correlations were developed for the isothermal friction factor as a function of Reynolds number, and for the Nusselt number as a function of Reynolds number and the ratio of wall temperature to fluid temperature. The specimen with the pin fin internal geometry had significantly better heat transfer than the other specimens, but it also had higher pressure drop. For certain conditions of helium flow and heating, the temperature more than doubled from the inlet to the outlet of the specimens, producing large changes in gas velocity, density, viscosity, and thermal conductivity. These changes in properties did not affect the correlations for friction factor and Nusselt number in turbulent flow.

Olson, D. A.↗

Heat pipe heat transport system for the Stirling Space Power Converter (SSPC)

Life issues relating to a sodium heat pipe heat transport system are described. The heat pipe system provides heat, at a temperature of 1050 K, to a 50 kWe Stirling engine/linear alternator power converter called the Stirling Space Power Converter (SSPC). The converter is being developed under a National Aeronautics and Space Administration program. Since corrosion of heat pipe materials in contact with sodium can impact the life of the heat pipe, a literature review of sodium corrosion processes was performed. It was found that the impurity reactions, primarily oxygen, and dissolution of alloy elements were the two corrosion process likely to be operative in the heat pipe. Approaches that are being taken to minimize these corrosion processes are discussed.

Alger, Donald L.↗

Forced Convection Boiling and Critical Heat Flux of Ethanol in Electrically Heated Tube Tests

Electrically heated tube tests were conducted to characterize the critical heat flux (transition from nucleate to film boiling) of subcritical ethanol flowing at conditions relevant to the design of a regeneratively cooled rocket engine thrust chamber. The coolant was SDA-3C alcohol (95% ethyl alcohol, 5% isopropyl alcohol by weight), and tests were conducted over the following ranges of conditions: pressure from 144 to 703 psia, flow velocities from 9.7 to 77 ft/s, coolant subcooling from 33 to 362 F, and critical heat fluxes up to 8.7 BTU/in(exp 2)/sec. For the data taken near 200 psia, critical heat flux was correlated as a function of the product of velocity and fluid subcooling to within +/- 20%. For data taken at higher pressures, an additional pressure term is needed to correlate the critical heat flux. It was also shown that at the higher test pressures and/or flow rates, exceeding the critical heat flux did not result in wall burnout. This result may significantly increase the engine heat flux design envelope for higher pressure conditions.

Meyer, Michael L.↗

Effects of Cross-Sectional Shape, Solidity, and Distribution of Heat-Transfer Coefficient on the Torsional Stiffness of Thin Wings Subjected to Aerodynamic Heating

A study has been made of the effects of varying the shape, solidity, and heat-transfer coefficient of thin wings with regard to their influence on the torsional-stiffness reduction induced by aerodynamic heating. The variations in airfoil shape include blunting, flattening, and combined blunting and flattening of a solid wing of symmetrical double-wedge cross section. Hollow double-wedge wings of constant skin thickness with and without internal webs also are considered. The effects of heat-transfer coefficients appropriate for laminar and turbulent flow are investigated in addition to a step transition along the chord from a lower to a higher constant value of heat-transfer coefficient. From the results given it is concluded that the flattening of a solid double wedge decreases the reduction in torsional stiffness while slight degrees of blunting increase the loss. The influence of chordwise variations in heat-transfer coefficient due to turbulent and laminar boundary-layer flow on the torsional stiffness of solid wings is negligible. The effect of a step transition in heat-transfer coefficient along the chord of a solid wing can, however, become appreciable. The torsional-stiffness reduction of multiweb and hollow double-wedge wings is substantially less than that calculated for a solid wing subjected to the same heating conditions.

Thomson, Robert G.↗

Measurement of the Heat Capacity of He-II Under a Heat Current Near the Lambda Transition

We present preliminary measurements of the heat capacity of superfluid helium-4 under an applied heat current near the lambda transition. The calorimeter is a standard cylindrical thermal conductivity cell with a 0.6 mm gap between two copper endplates. The sidewall is made of stainless steel. A heat current density in the range of 1 to 4 microW/sq cm is applied through the helium sample while a pulse method is used to measure the heat capacity. Temperature changes are recorded with high-resolution thermometers (HRTs) located on the top and bottom endplates. Corrections are made to the readings of the HRTs to account for the Kapitza boundary resistance and the anomalous Kapitza boundary resistance. After the corrections, both the top and the bottom HRTs. give the same heat capacity values. The heat capacity is found to be much larger than the prediction of recent theories. We also plotted our data on a scaled plot to test the prediction of scaling by the theories. The result and its interpretation will be presented. The cell height was deliberately made to be thin to reduce the effects of gravity. Nonetheless, gravity is expected to have significant effects on the heat capacity data in the temperature range of our measurement. A space experiment would remove this unwanted gravity effect and allow the true physics to be examined. Moreover, in the absence of gravity, a deeper cell can be used allowing HRTs to be mounted on to the sidewall providing direct measurements of the helium temperature, unaffected by the anomalous Kapitza boundary resistance.

Harter, Alexa W.↗

Loop Heat Pipe Operation Using Heat Source Temperature for Set Point Control

Loop heat pipes (LHPs) have been used for thermal control of several NASA and commercial orbiting spacecraft. The LHP operating temperature is governed by the saturation temperature of its compensation chamber (CC). Most LHPs use the CC temperature for feedback control of its operating temperature. There exists a thermal resistance between the heat source to be cooled by the LHP and the LHP's CC. Even if the CC set point temperature is controlled precisely, the heat source temperature will still vary with its heat output. For most applications, controlling the heat source temperature is of most interest. A logical question to ask is: "Can the heat source temperature be used for feedback control of the LHP operation?" A test program has been implemented to answer the above question. Objective is to investigate the LHP performance using the CC temperature and the heat source temperature for feedback control

Ku, Jentung↗

Monitoring and Assessing Heat Vulnerability to Identify Locations for Heat Mitigation Efforts in Sarasota, Florida

Located in the coastal subtropical region, Florida’s Sarasota County receives plenty of sunlight for more than half of the year. However, the ongoing rise in summer temperatures attributed to climate change poses an increasing vulnerability to extreme heat for the residents. Moreover, the area's high relative humidity exacerbates the discomfort of high temperatures, thereby intensifying the severity of heat events and elevating the risks of heat-related illnesses. Our collaborations with Sarasota County Sustainability underscore shared concerns about the impact of urban heat island (UHI) on the community. We utilized Earth observation data from NASA Landsat 8 and Landsat 9’s Thermal Infrared Sensors (TIRS) and the International Space Station’s Ecosystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS) to model UHI effects within the county during the summer from 2019 to 2023. By implementing the open-source Integrated Valuation of Ecosystem Services and Tradeoffs (InVEST) Urban Cooling software model, ArcGIS ModelBuilder, and principal component analysis, we identified the land surface temperature variance within the county and areas that are least capable of mitigating the effects of UHI. In addition, we use socioeconomic and demographic data as indicators to quantify vulnerability at the census tract level. The results revealed that heat intensity varies significantly across Sarasota County, with the highest temperatures being in the more developed western part of the region. We pinpointed that at least three vulnerable communities reside in high-heat regions: North Sarasota, Venice, and North Port. These areas demonstrate a confluence between socioeconomic sensitivity and environmental hazard, indicating a high priority in future heat mitigation efforts.

Theresia Phoa↗

Suitable low Global Warming Potential (GWP) refrigerants for two-speed Heat Pumps for residential applications based on speed Heat Pumps for residential applications based on simulated performance simulated performance

Cold climate Heat Pumps (CCHPs) using single-speed compressors in tandem have been successfully built and tested to reach its performance metrics with outdoor temperatures as low as -25°C. CCHPs must be designed to alleviate the problems of too high discharge temperatures, low suction pressure and high-pressure ratio at low ambient conditions and insufficient heating capacity relative to the heating capacity at 8.3°C. In this paper we recognize those concerns. Low-GWP refrigerants are screened based on the shape of their T-S saturation boundary. Simulations of the performance of low-GWP refrigerants (R32, R454B, R466A, and R452B) relative to R410A is done using the DOE/ORNL Heat Pump Design Model at the component level. Systemic inefficiency, the root cause of lost work, is addressed by component-level exergy analysis to refine design options. CCHPs using low-GWP refrigerants addresses issues of reducing energy consumption, lowering carbon footprint, and enabling environmentally sustainability. The CCHP was designed to meet a HSPF > 11.0 and SEER > 15.0 having adequate heat pump heating capacity down to -25°C. It is estimated that at least 2.6 million U.S homes using electric furnaces and heat pumps in cold or very old climates with an annual energy consumption of 0.17EJ would benefit by CCHPs.

Ally, Moonis↗

Experimental Investigation on Heating Performance of a Cold Climate Thermoelectric-Assisted Heat Pump

To accelerate the electrification of air source heat pumps (ASHPs) in cold climates across the United States, various initiatives have been launched to enhance the effectiveness of ASHPs. One avenue of research involves incorporating thermoelectric (TE) technology into vapor compression refrigeration cycles. This study aims to assess the heating performance of a cold climate ASHP by employing TE modules as a liquid line subcooler. The tested system is a nominal 4.5-ton split heat pump utilizing R410A, equipped with a scroll compressor and an accumulator. An electronic expansion valve was employed for both cooling and heating modes. Two configurations of TE sub-coolers, one utilizing 2 TE bundles and the other 4 TE bundles, were integrated into the liquid line of the tested system. The heating performance of these configurations was evaluated. The results revealed that activating the TE subcooler led to a notable increase in total heat capacity, reaching 1318 W at -15.0 °C and 1164 W at -19.0 °C. The corresponding TE coefficients of performance (COPs) were 1.76 and 1.63, respectively. The activation of the TE sub-cooler resulted in a slight reduction in the overall system COP, with a decrease ranging from -2.6% to -4.2% for these two temperatures. The system COPs were measured at 2.10 and 1.86 for -15.0 °C and -19.0 °C, respectively. This prototype demonstrated a significant augmentation in heating capacity with a minimal sacrifice in COP.

Hu, Yifeng↗

Bio-inspired alula-based winglet design for enhanced heat transfer in high temperature fin-and-tube heat exchangers

Fin-and-tube heat exchangers (FTHEs) are widely used for high-temperature flue-gas heat recovery, but their performance is often limited by wake regions and non-uniform fin-surface temperatures. This study proposes and numerically evaluates four bio-inspired longitudinal vortex generator (VG) configurations in a high-temperature FTHE with flue-gas inlet temperature ∼1230 K: double-delta, curved double-delta, alula, and a new curved-alula geometry. The reference fin is not hydraulically plain; it already incorporates leading-edge separation columns and convex protrusions, so the alula-type winglets are assessed as downstream add-ons acting on a strongly disturbed flow. In a second step, perforations (one, two and three circular holes) are introduced into the curved-alula VGs to further tailor the flow field. Three-dimensional simulations with the Shear Stress Transpor (SST) $k - ω$ model, temperature-dependent flue-gas properties and conjugate conduction are carried out for gas-side Reynolds numbers $Re_g ≈ 8.0$ x $10^2 - 3.6$ x $10^3$ (mass flow rates 0.5 – 2.5 g/s), and the designs are compared in terms of surface heat flux, Nusselt number, friction factor and hydrothermal performance factor (HTPF). For this already-promoted fin, the additional downstream winglets provide moderate, incremental hydrothermal gains. At the highest Reynolds number, the best non-perforated design (curved-alula) increases surface heat flux from 1630.9 to 1794.7 kW/m² (∼ 10 % gain) and the Nusselt number from 227.6 to 242.6 (∼ 7 % gain), while the friction factor rises from 0.26 to about 0.30, yielding HTPF values close to unity (∼ 0.9 – 1.0). Introducing circular perforations into the curved-alula winglets acts mainly as a wake-bleeding refinement: the three-hole configuration provides a heat flux of 1824.7 kW/m² and a pressure drop of 127.9 Pa, with HTPF in the range ∼ 1.03 – 1.14 and a small (∼ 1 – 3 %) improvement over the solid curved-alula design. Flow-field analysis shows that the perforated curved-alula VGs shrink tube-wake regions, thin the thermal boundary layer and homogenize the fin-surface temperature (outlet-gas temperature ∼ 510 – 520 K and fin-surface temperature ∼ 420 – 421 K for the three-hole case). An optimal flue-gas mass flow rate of ∼ 1 g/s ($Re_g ≈ 1.5$ x $10^3$) is identified, beyond which additional heat-transfer gains are offset by rapidly increasing pressure losses. Overall, the results highlight that initial fin geometry and VG placement are as important as VG shape: alula-based winglets are expected to yield larger relative gains on simpler flat-fin layouts or when positioned closer to the fin leading edge and tube

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modelling of Wastewater Heat Recovery Heat Pump Systems

Wastewater heat recovery is currently an underutilized technology that could be part of solving the climate crisis. A large portion of the heat that leaves a building in the form of wastewater is potentially recoverable for pre-heating domestic hot water or other service water systems. While there are several different approaches to wastewater heat recovery, this project focused on creating detailed, integrated building models for wastewater heat recovery heat pump systems. EnergyPlus models were developed featuring inputs and assumptions corresponding to manufacturers’ specifications, performance lab test data and feedback from engineering consultants. EnergyPlus’s supervisory control Energy Management System objects were heavily relied upon to overcome modelling challenges. The developed EnergyPlus model was integrated into U.S. Department of Energy New Construction Reference Building models for various climate zones and building types to assess potential energy use, energy cost and greenhouse gas emission reductions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Flow Visualization, Heat Transfer, and Critical Heat Flux of Flow Boiling in Earth Gravity with Saturated Liquid-Vapor Mixture Inlet Conditions – In Preparation for Experiments Onboard the International Space Station

This study investigates flow boiling of n-Perfluorohexane with saturated two-phase mixture inlet in a rectangular channel of dimensions 114.6-mm heated length, 2.5-mm width, and 5 mm-height. The experiments were performed as part of the Mission Sequence Testing of the Flow Boiling and Condensation Experiment’s (FBCE) Flow Boiling Module (FBM) in the vertical upflow configuration in Earth gravity using the same experimental system that was launched to the International Space Station (ISS) in August 2021. The operating parameters varied are heating configuration (single- and double-sided), mass velocity (380 – 2400 kg/m2s), inlet quality (0.011 – 0.519), and inlet pressure (120 – 179 kPa). High-speed video photographs are presented to explain the two-phase flow patterns within the channel’s heated length. Flow patterns are constituted by low-density and high-density fronts moving along the channel, with the high-density fronts gradually reducing in length due to evaporation. Heat transfer results in terms of flow boiling curves, streamwise wall temperature profiles, streamwise heat transfer coefficient profiles, and average heat transfer coefficients are presented and trends discussed. CHF data from the present experiments are combined with prior databases to compile a consolidated FBCE-CHF database for saturated inlet to expand the ranges of operating conditions and include other flow orientations in Earth gravity. Experimental CHF trends are also discussed. The interfacial lift-off model shows a good CHF predictive accuracy evidenced by a mean absolute error of 11.97% for this consolidated database after constraining it to mass velocities greater than or equal to 500 kg/m2s. Finally, this study confirmed reliability of the upcoming ISS experiments for saturated inlet conditions and the collected Earth-gravity data will be compared to ISS microgravity data.

Flow boiling↗

Thermodynamic Modeling of Heat Engines Including Heat Transfer and Compression–Expansion Irreversibilities

In this paper, a thermodynamic model based on an endoreversible engine approach is developed to analyze the performance of heat engines operating under different thermodynamic cycles. The model considers finite heat transfer rate, variable heat source and sink temperatures, and irreversibilities associated with the expansion and compression. Expressions for the maximum power and efficiency at maximum power output are obtained as a function of hot and cold reservoir temperatures, the equivalent isentropic efficiency of compression and expansion components, and the effective conductance ratio between heat exchangers. In all cases, the Curzon–Ahlborn efficiency is retrieved at constant reservoir temperatures and neglected compression–expansion irreversibilities. The proposed model allows assessing the effect of isentropic efficiencies and heat exchanger design and operation characteristics for different thermodynamic cycles.

33 ADVANCED PROPULSION SYSTEMS↗

Searching for Suitable Binary Fluid for an Ejector Heat Pump for Domestic Water Heating

Water heating is a major source of energy consumption in the U.S. residential sector. Heat pumps can significantly increase the energy efficiency of water heating. An ejector heat pump (EHP) is a novel, thermally driven heat pump that uses an ejector as a thermocompressor. Choosing suitable working fluids is critical in developing high-performance EHPs. Therefore, this research screens binary fluid pairs (BFPs) for EHPs to produce domestic hot water at a high coefficient of performance (COP). The criteria for screening BFP candidates for EHP water heaters (EHPWHs) are established, and BFP candidates are shortlisted. This study identifies HFE7000, Novec649, HFE7100, HFE7200, and HFE7500 for the primary fluids and RE170, R600a, R600, and R1234ze(Z) for the secondary fluids. The thermodynamic model is employed to investigate the performance of EHPWHs using the shortlisted BFPs under various operating parameters, including the evaporation pressure of the primary working fluid in the high-temperature evaporator and the condensation temperature. In conclusion, the highest heating-cycle COP of 1.328 is achieved by an EHPWH operating with HFE7000/R600 at a condenser temperature of 50 °C and a pressure of 1.69 MPa in the high-temperature evaporator.

42 ENGINEERING↗

Regional suitability of heating tower heat pumps based on technical and economic performance maps

The heating tower heat pump (HTHP) technology is evolving rapidly due to its high performance in summer and frost-free characteristic in winter. However, lacking comprehensive comparisons between the HTHP and conventional methods, such as air-source heat pump (ASHP), and chiller and boiler, greatly limits its applications. To address this problem, this paper carries out technological and economic performance analyses of the three systems in 353 locations over China by the processes of building load calculation, system sizing, annual simulation, performance comparison, and demonstration. Energy saving principle and potential of the HTHP are presented and explained. Based on that, economic performance comparison is conducted by considering the energy conversion efficiency and prices. The results show that the HTHP has advantage over the ASHP in most locations in China. The improvement in annual coefficient of performance (COP) is about 10% to 20%. For the locations in southwest China like Chongqing, the improvement is also less than 10% due to the large regeneration penalization in winter and small difference between dry-bulb and wet-bulb temperature in summer. The annual COP of the HTHP is 10% to 23% higher than that of the chiller and boiler in hot summer and cold winter zone, and cold zone. However, the HTHP shows no advantage over the chiller and boiler in severe cold zone because of the low efficiency of heat pump in winter, neither in hot summer and warm winter zone due to the small heating load. Based on the results, technical and economic performance maps are developed to guide the application of the HTHP in different climate regions.

heating tower heat pump, air-source heat pump, chi↗