At least 199 records · Page 11

Diagenesis is key to unlocking outcrop fracture data suitable for quantitative extrapolation to geothermal targets

Exceptionally large, well-exposed sandstone outcrops in New York provide insights into folds, deformation bands, and fractures that could influence permeability, heat exchange, and stimulation outcomes of geothermal reservoir targets. Cambrian Potsdam Sandstone with <5% porosity contains decimeter-scale open, angular-limbed monoclines <0.5 km apart with associated low-porosity mm-wide cataclastic deformation bands. Crossing and abutting relationships among sub-vertical opening-mode fractures show four chronological Sets A–D, striking NNW, NE, NW, and ENE, respectively. Fracture lengths and heights range from millimeters to tens of meters. Sets A and C macro-fractures, and possibly B and D, contain quartz deposits. All sets have abundant associated quartz cemented microfractures that also record set orientations and crosscutting relations. Quartz cement deposits—evidence of diagenesis—are the key to identifying attributes of outcrop fractures suitable for extrapolation to geothermal targets in sandstones because they show which fractures formed in the subsurface. Set A fluid inclusion homogenization temperatures (120°C–129°C) are compatible with fracture at >3 km depth. Fractures are stiff and those ≥0.05 mm (Set C) and ≥0.1 mm (Set A) are open and potentially conducive to flow. Sets A and D are abundant in outcrops with close fracture spacing—0.18 m and 0.68 m, respectively—and define a rectangular connectivity network dominated by crossing and abutting X and Y nodes. Set A aperture distributions follow a power law with slope –0.8 up to 0.15 mm; other sets have lognormal distributions. Set A and D microfractures are weakly clustered, while macro-fractures commonly have 1D anticlustered (regular or periodic) arrangements at shorter length scales (<0.2 m). Sub-horizontal fractures are barren and may have formed near the surface. Fracture heights, lengths, and spatial arrangements show good trace connectivity but low open connectivity. For geothermal applications, outcrop results predict low initial well-test permeabilities owing to quartz disconnecting open fractures, but stimulation of closely spaced microfractures and partly open macro-fractures could yield high surface area for heat exchange. Quantitative extrapolation of key fracture attributes like abundance, orientation, spatial arrangement, length, and open fracture connectivity is possible from outcrops to fractured reservoirs if differing thermal histories and diagenesis are accounted for.

02 PETROLEUM↗

Incorporating Heterogeneity into 3D Geologic Models for the Alluvial Basin Reference Case

The unsaturated zone alluvium reference case is one of several geologic systems under consideration by the U.S. Department of Energy Office of Nuclear Energy for hosting repositories for spent nuclear fuel and associated waste (Sevougian et al., 2019). As noted by Mariner et al. (2018), the generic alluvial basin offers positive attributes that merit its consideration as a reference case by the Spent Fuel and Waste Science and Technology (SFWST) campaign. Hundreds of alluvial basins and sub-basins are scattered across the arid western United States (Figure 1-1). Precipitation and infiltration rates are relatively low with high evapotranspiration, resulting in deep regional water tables. Deep regional water tables allow for significant vertical separation between proposed repository depths and groundwater and thus longer transport paths from a hypothetical repository to an aquifer. Accumulations of alluvial sediments within these basins are typically on the order of hundreds of meters, and locally may exceed 1,000 m in thickness, as is the case for the Deming sub-basin in southern New Mexico. In alluvial basins, alluvium creates a thick geologic host medium that serves as the natural barrier system (NBS) in the conceptual model framework of a geologic disposal system and isolates the waste packages from receptors in the biosphere. Further, alluvial basin fill is typically comprised of stacked playa and lacustrine deposits along the basin axis (Perry et al., 2018). Characterized by low permeability, these layers protect the biosphere above the repository and the groundwater resources below the repository by limiting flow and transport of radionuclides.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Causes of and Solutions to Wind Speed Bias in NREL's 2020 Offshore Wind Resource Assessment for the California Pacific Outer Continental Shelf

This report provides the results of a detailed analysis into the causes of high wind speed bias in the 20-year wind resource data set for offshore California the National Renewable Energy Laboratory (NREL) released in 2020, herein called CA20. The data set was developed using the state-of-the-art Weather Research and Forecasting (WRF) model. Notably, no floating lidars were available at the time in offshore California to validate offshore hub-height wind speeds. In late 2020, the Pacific Northwest National Laboratory (PNNL) deployed two floating lidars in the California outer continental shelf (OCS), near the Bureau of Ocean Energy Management (BOEM) call areas of Humboldt and Morro Bay. Using these observations through 2021, NREL found considerable bias in modeled hub-height winds at both locations: up to +2 m/s at Humboldt over a 6-month period, and up to +1 m/s at Morro Bay over a one-year period. Upon the discovery of this bias, the Department of Energy (DOE) and BOEM funded NREL and PNNL to investigate the causes of, impacts of, and solutions to the bias in the CA20 data set. This report summarizes the findings of this research. We first investigated whether different WRF model setups could lead to reduced bias. We found that the choice of planetary boundary layer (PBL) scheme - which controls the vertical turbulent mixing of momentum, heat, and moisture in the lowermost part of the atmosphere - greatly affected hub-height wind speeds in the region. Specifically, switching from the Mellor-Yamada-Nakanishi-Niino (MYNN) scheme used in CA20 (and widely used across a range of operational and research weather models) to the less common Yonsei University (YSU) scheme nearly eliminated the bias at both the Humboldt and Morro Bay lidar locations. The large discrepancy between the MYNN- and YSU-modeled hub-height winds pointed towards the role of atmospheric stability. In general, PBL schemes agree well in conditions of high turbulence and mixing, normally referred to as "unstable" conditions. By contrast, PBL schemes start to diverge in "stable" conditions, where turbulence is low and thermal stratification (i.e., higher temperature air sitting on top of colder air) greatly suppresses vertical mixing. Under such conditions, winds aloft can decouple from surface effects and greatly accelerate, causing high wind speeds at hub-height and frequent low-level jets (LLJs). We determined that these stable conditions are in fact dominant in offshore California. The region is characterized by moderate-to-extreme stable stratification with a LLJ on average around 200 meters above sea-level. To our knowledge, no wind energy area globally has as strongly stable stratification as offshore California. Under these extreme conditions, we determined that the MYNN scheme models higher stability than YSU, resulting in less vertical turbulent mixing than YSU, allowing for the acceleration of hub-height winds, more intense LLJs, and higher-amplitude inertial oscillations. Using surface observations, we found that MYNN overestimates near-surface stability, whereas YSU tends to model stability better. We then considered several short-term case studies to assess additional meteorological drivers of the bias at Humboldt. We found that during synoptic scale northerly flows driven by the North Pacific High and inland thermal low, a coastal warm bias in the MYNN case studies contributes to the modeled wind speed bias by altering the boundary layer thermodynamics via a thermal wind mechanism. Given the strong performance of the YSU-based runs in offshore California, NREL has produced and published an updated version of the CA20 data set with YSU as the PBL scheme. This updated data set is now part of NREL's 2023 National Offshore Wind (NOW-23) data set, which covers all the U.S. offshore waters. The development and final validation of the NOW-23 data set in offshore California is documented in this report.

17 WIND ENERGY↗

Congestion Management Solutions for Enhanced Distribution System Operations with Aggregated Distribution Grid Resources Providing Grid Services and Market Participation

Microgrids and other aggregations of distribution grid resources (DGRs) are poised to actively participate in electricity markets and provide essential grid services in the coming years. In fact, DGRs already play such a role through behind-the-meter (BTM) demand response programs and small-scale BTM dispatchable generation initiatives. At the same time, the rapid growth of artificial intelligence (AI) and cryptocurrency datacenters imposes significant, often unpredictable, demands on the power distribution system. Aggregated DGRs can serve as flexible resources that help mitigate these pressures by using available transmission and distribution capacity more efficiently, supporting resource adequacy and other reliability services, and providing bridge strategies while long-term transmission infrastructure is being developed. The impacts this activity will have on distribution networks are not fully understood and could present significant challenges for distribution utilities due to capacity constraints and the need for congestion management. Technical issues include reverse power flow, variability and possible degradation of equipment integrity, voltage violations, and customer power quality concerns. These issues will likely intensify as electricity market operators across the United States implement Federal Energy Regulatory Commission Order 2222 over the next few years.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Unclassified Source Term and Radionuclide Data for the Groundwater Flow and Contaminant Transport Model for Corrective Action Units 101 and 102: Central and Western Pahute Mesa, Nye County, Nevada, Revision 1

This report documents the evaluation of information and data available on the unclassified source term and radionuclide (RN) contamination for Central and Western Pahute Mesa (PM): Corrective Action Units (CAUs) 101 and 102. The Central and Western PM CAUs constitute two areas of the Nevada National Security Site (NNSS) used for underground nuclear testing (Figure 1-1). Eighty-five underground nuclear tests were conducted at the PM CAUs between 1965 and 1992 (NNSA/NFO, 2015b). Underground nuclear tests deposit radioactive elements in the subsurface, resulting in groundwater contamination in the vicinity of the underground test locations. At the PM CAUs, the testing resulted in more than 2.68 × 10 7 curies (Ci) of radioactivity (decay-corrected to September 30, 2012) remaining underground (Finnegan et al., 2016). Of the 85 underground nuclear tests conducted at the PM CAUs, three were shallow tests detonated within 200 meters (m) of the surface and referred to as the “near-surface tests”; the remaining 82 were detonated deeper than 200 m below ground surface (bgs) and are referred to as the “deep underground tests” in this document.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A hierarchical framework for aggregating grid-interactive buildings with thermal and battery energy storage

The behind-the-meter (BTM) thermal and battery energy storage can help improve energy efficiency, reduce energy costs, and enhance energy resilience, particularly in rural areas and for disadvantaged communities. Aggregating numerous BTM energy storage systems can act as a price influencer with a significant source of load shifting and peak demand reduction. An integrated and scalable control mechanism is required to effectively utilize energy storage systems and flexible building loads to maximize the economic benefits, considering various distribution system constraints. Here, this paper presents an innovative hierarchical coordination framework for energy storage and flexible load in buildings, considering various factors such as electricity prices, thermal comfort, and distribution system modeling and constraints. At the upper level, a distribution system operator optimizes the power flow to minimize its power procurement costs from the electricity wholesale market, while at the lower level, aggregators determine the optimal dispatch of battery and thermal energy storage systems in multiple buildings on behalf of end-users to minimize operating costs according to the power prices. These problems are solved using a game-theoretic approach through negotiations between the distribution system operator and aggregators as a bi-level decision model. Simulation case studies have been performed for a test distribution network with a number of building end-users using energy storage systems to quantify the performance of aggregators. The results demonstrate that the proposed strategy can reduce peak load for a reliable electricity distribution network while saving electricity bills for customers.

25 ENERGY STORAGE↗

Simulation-Based Analysis of Feeder Operation with Different PV Smart Inverter Functions on an Actual Distribution System: Preprint

High penetration of photovoltaics (PV) in distribution feeders can cause problems, such as overvoltage, reverse power flow, and large net load changes. Traditional voltage regulation devices, such as capacitors and voltage regulators, can solve some of these problems but might have some delays. Today, smart inverters are gradually being used to provide voltage regulation and frequency support in distribution systems. Different smart inverter settings have been recommended in various rules and standards; however, the potential benefits and their impacts on distribution system operation are not well compared and studied. This paper presents a comparison of different smart inverter settings as applied to a distribution system. An actual feeder model from San Diego Gas & Electric Company is used to conduct the simulation. Additionally, a load disaggregation method is proposed to disaggregate the load and PV profile for each load location using advanced metering infrastructure net load measurements. Then, different smart inverter settings are applied to the PV systems in the feeder, and the simulation results are compared. The results show that the implementation of specific functions of smart inverters can reduce voltage exceedances, and the utility can determine the specific inverter setting based on its operational requirements.

distribution system↗

The EGS Collab Project: Learnings from Experiment 1

The primary objective of the EGS Collab Project sponsored by DOE is to increase the understanding needed to efficiently implement enhanced geothermal systems (EGS). One goal of the EGS Collab project is to create a collaborative research environment in which to study stimulation of crystalline rock at the 10 meter scale. Key to this effort is the collection of high quality data to allow comparison to numerical coupled process models in an effort to build confidence in the codes and modeling techniques used. In response to this, the EGS Collab team has created an underground test bed at the Sanford Underground Research Facility (SURF) in Lead SD at a depth of approximately 1.5 km to examine hydraulic fracturing (Experiment 1). We are currently designing a second test bed aimed at investigating shear stimulation (Experiment 2). At the Experiment 1 location, we have characterized our host rock using laboratory testing and numerous field-based geophysical and geological techniques, and created a well-instrumented test bed to allow us to carefully monitor stimulation events and flow tests. In addition to the installed geophysical sensors, we have used tracer tests, differences in the ambient microbial communities at flow collection locations, and cold water injection to inform us about dynamic flow pathways. In Experiment 1, we have hydraulically stimulated the host rock in a number times at several locations in one well, creating new fractures that connect to existing fractures between the injection and production boreholes. We have performed long-term ambient and chilled water injection tests as an analog to EGS, and have monitored system changes resulting from these water injections through geophysical monitoring, flow and pressure measurements, tracer tests, and microbiology. Here, we summarize the tests performed, issues identified including poroelastic and thermoelastic effects, Joule-Thomson effects, restarting effects, indications of flow channeling, and the primary learnings from Experiment 1.

Enhanced Geothermal Systems, EGS Collab, stimulati↗

Electrical Resistivity Tomography Monitoring of In Situ Soil Flushing at the Hanford 100-K East Area: 100KE Soil Flushing Monitoring

Former operations in the 100-KE Area at the Hanford Site resulted in vadose zone hexavalent chromium that provides a source of groundwater contamination. Previous efforts to remediate vadose zone chromium involved excavation and offsite treatment of contaminated soils. Although much of the chromium was removed, contamination still exists in native soil between the water table and the bottom of the pit, which has since been backfilled. In-situ soil flushing was tested at the 100-KE Area to accelerate the removal of the remaining hexavalent chromium in the vadose zone. Soil flushing works by applying clean flush water at the surface, which mobilizes and transports chromium as it migrates downward to the water table. Once the chromium reaches the water table, it is hydraulically contained, extracted, and treated through pump and treat operations. The efficacy of soil flushing is directly related to the volume of clean water that infiltrates through contaminated soils. Therefore, performance monitoring requires and understanding of flush water migration through the vadose zone. It is challenging to comprehensively assess soil flushing performance via borehole access due to the limited volume of investigation afforded by a given wellbore. As an alternative, 3D time-lapse electrical resistivity tomography (ERT) was tested as a method of monitoring the distribution of flush water over time within the vadose zone. ERT is a method of imaging the bulk electrical conductivity of the subsurface, which is highly dependent on water saturation levels in unconsolidated and unsaturated sediments. Thus, the timing and location of changes in bulk conductivity caused by soil flushing can be used to infer flush water migration pathways. In this report we present results of 3D time-lapse ERT imaging during two separate soil flushing campaigns conducted during the spring and summer months of 2022 and 2023. Results show generally that: 1) Pit backfill materials appear to nominally have larger permeability than native soils. Consequently, the boundary between pit backfill and native soil had a significant impact on flush water migration, causing some flush water to migrate along the pit boundary to the bottom of the pit. 2) Non-uniform flows, likely caused by variations in hydrogeologic properties, developed in the pit backfill materials, resulting in uneven flush water distribution on the southern margin of the soil flushing zone. 3) Redistribution of water at the interface between backfill materials and Hanford formation materials likely facilitated elevated and uniform distribution of flush water within native soils beneath the deeper parts of the pit boundary beneath the center of the flush zone, which presumably overlie soils with elevated chromium contamination. These areas appear to have been infiltrated by higher volumes of flush water than the northern and southern margins of the flush zone. 4) In comparison to 2022, high flush water application rates significantly improved flush water distribution throughout the target flushing zone. 5) Imaging resolution was limited to a depth of approximate 20 meters below the land surface, due primarily to limitations on the lateral extent of the surface ERT array. The ~10 m region of the vadose zone between approximately 130 meters elevation and the water table at approximately 120 meters elevation was unresolved.

100 Area↗

Bayesian Framework for Multi-Timescale State Estimation in Low-Observable Distribution Systems

To support the smart grid paradigm, there has been a significant increase in sensor deployments and metering infrastructure in distribution systems. However, the measurements provided by these sensors and metering devices are typically sampled at different rates and could suffer from losses during the aggregation process. It is crucial to effectively reconcile the time-series measurements for a reliable state estimation. While weighted least squares has been the traditional approach for state estimation, sparsity-based approaches like matrix completion have become popular due to their superior performance in low-observability conditions. This paper proposes a Bayesian framework for both multi-timescale data aggregation and matrix completion based state estimation. Specifically, the multiscale time-series data aggregated from heterogenous sources are reconciled using a multitask Gaussian process that exploits the spatio-temporal correlations. Here, the resulting consistent timeseries alongwith the confidence bound on the imputations are fed into a Bayesian matrix completion method augmented with linearized power-flow constraints to accurately estimate the states in low-observability conditions. Results on three phase unbalanced IEEE 37 and IEEE 123 bus test systems reveal the superior performance of the proposed Bayesian framework. The computational complexity for the proposed Bayesian framework is also quantified.

42 ENGINEERING↗

Stable water isotopes and tritium data from porewater at Elkhorn Slough

Salt marshes are dynamic hydrologic systems where terrestrial groundwater, terrestrial surface water, and seawater mix due to bi-directional flows and pressure gradients. Due to the counteracting terrestrial and marine forcings that control these environments, we do not comprehensively understand water fluxes in these complex coastal systems. To understand the water sources, flow directions, and velocities in salt marsh porewater, we collected geochemical tracers across a hillslope-to-salt marsh continuum in a salt marsh experiencing daily inundation of estuarine surface water (SW) from tides and mixing of fresh seasonal groundwater. The experimental transect is located at the Elkhorn Slough National Estuarine Research Reserve.Here we present a data table (.csv) with the results of electrical conductivity, stable water isotopes, and tritium in porewater across several elevations in the hillslope-to-salt marsh continuum (information in the data set). We analyzed the stable water isotope samples by cavity ring-down spectroscopy in a Picarro L2130-i at the University of California Santa Cruz (accuracy of 0.025‰ and 0.1‰ for δ18O and δ2H, respectively). We measured the electric conductivity of the samples with an Orion Star™ A329 multiparameter meter (0.5% accuracy, Thermo Fisher Scientific, Massachusetts, USA). We analyzed 3H samples at Lawrence Livermore National Laboratory by helium-3 accumulation (Clarke et al., 1976; Surano et al., 1992).

54 ENVIRONMENTAL SCIENCES↗

Solar-Plus-Storage Program Design: Frameworks and Examples [Slides]

The Columbia River Treaty Tribes in the Pacific Northwest - the Nez Perce, Umatilla, Warm Springs, and Yakama - hold treaty-reserved fishing rights for the Columbia River, the largest river in North America flowing into the Pacific Ocean. The four Tribes, through the Columbia River Inter-Tribal Fish Commission (CRITFC), prepared a vision for a more harmonized energy and water system in their 2022 Energy Vision for the Columbia River Basin. In it, the four Tribes envision a future where the Columbia Basin electric power system supports healthy and harvestable fish and wildlife populations, protects Tribal treaty and cultural resources, and provides clean, reliable, and affordable electricity. To help realize the Energy Vision, CRITFC received technical assistance from the National Renewable Energy Laboratory (NREL) through the Communities Local Energy Action Program (LEAP) pilot with the goal of ensuring that the Tribes are fully informed and prepared to integrate their interests into regional power system planning. This resource aims to provide an overview of program and policy design frameworks for behind-the-meter (BTM) energy storage and solar-plus-storage programs and examples from across the United States. This information is intended to build CRITFC's understanding of potential policies and program designs that could support the deployment of solar photovoltaics (PV) and energy storage in the Pacific Northwest.

14 SOLAR ENERGY↗

Assessment of Updraft Modeling Bias Using Computational Fluid Dynamics

Golden Eagle (Aquila chrysaetos) habitats may overlap with wind energy development in some regions of the US. Eagles, and similar soaring bird species, are therefore at risk of collision with wind turbines when flying through wind farms. Recently developed behavioral modeling approaches can predict the presence of eagles near turbines within the rotor-swept layer but require reliable prediction of atmospheric flowfield conditions. In particular, the vertical component of the wind speed dictates a soaring bird's ability to maintain or gain altitude, since they rely on updrafts to subsidize their flight. In this work, we investigate the atmospheric conditions around a wind farm in complex terrain and compare methods for atmospheric characterization. We use computational fluid dynamics (specifically, large-eddy simulations, or LES) to simulate the atmospheric boundary layer over a region encompassing multiple wind farms with high temporal and spatial resolution (seconds and 10's of meters, respectively). We compare traditional non-simulation-based methods of determining the orographic updraft potential based on wind direction, terrain slope and aspect, with the flowfields from LES that include both orographic updrafts alone and combined thermal and orographic updrafts. Preliminary analysis suggests that although the model captures the horizontal pattern of vertical updrafts, their magnitude can be improved with information about the surface heat flux, which is usually correlated with time of the day. Within our study region, we found that the low-fidelity model may over- or underestimate updraft potential by up to 400% at 80 m AGL, depending on local orographic features. This can result in an inaccurate representation of eagle presence and, consequently, risk. Another important finding is that flowfield time-averaging can hide important details about the flight environment, including how thermally generated flow structures within the atmospheric boundary layer (e.g., convective rolls and/or cells) may be important drivers of eagle flight.

atmospheric turbulence↗

Integrated Framework of Multisource Data Fusion for Outage Location in Looped Distribution Systems

Accurate outage location is essential for expediting post-outage power restoration, minimizing outage duration, and enhancing the resilience of distribution networks. With the advent of advanced metering infrastructure, data-driven outage location methods have significantly advanced beyond traditional approaches that rely on manual inspections. However, existing methods still face critical challenges, like reliance on single-source data, limited ability to handle partially observable systems or difficulties with loop networks. To the best of our knowledge, no single approach has comprehensively addressed all of these challenges at once. To this end, this paper proposes a comprehensive multisource data fusion framework for outage locations via probabilistic graph networks. The framework consists of three key phases. First, a novel method for reconstituting distribution networks with loops is developed, transforming looped networks into multiple radial subnetworks that retain all outage causalities of the original network. Second, Bayesian network (BN) models are established for each subnetwork, integrating multiple data sources and network structures. Finally, a joint Gibbs sampling mechanism, featuring forward and backward information flow, is designed to merge data from separate BN models and maximize the utilization of limited evidence, ensuring accurate outage location identification. In conclusion, the framework was validated on two modified public test systems, and comparative studies confirmed its effectiveness.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DECOVALEX-2023: Task E Final Report

This is the Task E final report for DECOVALEX-2023. Task E is focused on understanding thermal, two-phase hydrological, and mechanical (TH2M) processes, especially related to predicting brine migration in the excavation damaged zone around a heated excavation in salt. Salt is attractive as a disposal medium for radioactive waste because it is self-healing and is essentially impermeable and essentially non-porous in the far field (away from excavations). Investigation of the short-term (days to years) near-field (centimeters to tens of meters) behavior of salt is important for radioactive waste disposal because this early period strongly controls the amount of brine in a salt repository. Brine leads to corrosion of waste forms and waste packages, and possible dissolution of radionuclides with brine transport being a potential transport vector to the accessible environment. The main test case used in Task E is the ongoing Brine Availability Test in Salt (BATS) heater test located underground at the Waste Isolation Pilot Plant (WIPP) near Carlsbad, New Mexico, USA. The Task was divided into a series of Steps. Step 0 was an introduction to processes in salt, that included matching historical unheated brine inflow data from boreholes at WIPP and matching temperature observations during BATS heater test 1a. Step 1 included validation of models against a thermo-poroelastic analytical solution relevant to heated boreholes in salt, and two-phase flow around an excavation in salt. Step 2 required all the individual components covered in steps 0 and 1 to come together to match observed brine inflow behavior during the BATS 1a heater test. There were a range of approaches from the teams, from mechanistic to prescriptive. Given the uncertainties in the problem, some teams used one- or two-dimensional models of the processes, while other teams included more geometrical complexity in three-dimensional models. The key learning points from Task E have been: • Heat conduction through salt typically requires non-linear thermal conductivity (as a function of temperature), but most models do a good job matching observations, given appropriate adjustments to the applied power and some thermocouple locations. • Thermal pressurization requires coupled thermal-hydrological-mechanical (THM) responses that consider the thermal expansion of the fluid and solid phases. • Initialization of two-phase flow models around a borehole or excavation in salt are more realistically represented as “wetting up”, rather than “drying down” (i.e., the initial state after excavation is mostly dry, rather than mostly wet). • The BATS 1a heater test includes a significant release of brine after the end of heating, which requires a large increase in permeability to recreate. Task E has been a great learning experience for all the teams involved, and feedback from the modeling teams has led to changes in the design of follow-on BATS experiments, which are now ongoing underground at WIPP. There was a balance throughout the task between freedom to model phenomena how each team saw fit, and prescriptiveness in problem design to bring the modeling teams closer together to allow attribution of smaller differences between models to different modeling choices. The modeling approaches seem to go through two phases: an early phase of discovery or testing, and a later phase of refinement and improvement. In future modeling efforts, different field data could be used (e.g., BATS 2) and more time should be included in the processes for teams to make multiple model refinement or even significant changes to their conceptual model or setup, based on lessons learned from the modeling exercise.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Paleotopography controls weathering of Cambrian-age profiles beneath the Great Unconformity, St. Francois Mountains, SE Missouri, U.S.A.

ABSTRACT Precambrian (1.4 to 1.5 Ga) granite and rhyolite in the St. Francois Mountains at the northeast corner of the Ozark Plateau in Missouri has been altered down to a depth up to 8 meters below the Great Unconformity (the contact between Paleozoic sedimentary rock and underlying Precambrian). Petrographic, geochemical, and mineralogic data indicate that at least two events generated this alteration: 1) surficial weathering due to subaerial exposure of the granite before Cambrian burial—this material is preserved as a paleosol; and 2) alteration due to reaction with basinal fluids channeled along the unconformity from nearby sedimentary basins long after burial by Paleozoic strata. To assess the variation between surficial weathering and basinal fluid alteration, we measured and sampled for petrologic, geochemical, and mineralogic data in the rock at and just below the Great Unconformity at three paleoelevations. Whole-rock geochemical oxide and X-ray diffraction data indicate that K-metasomatism and highly crystalline illite occurred in each profile. The K increase reflects crystallization of authigenic feldspar and illite from basinal fluids that were channeled along the Great Unconformity during younger Paleozoic fluid-flow events. Each profile also exhibits an upward increase in altered feldspar crystals and highly crystalline kaolinite, and an upward decrease in Ca and Na. Such changes reflect soil formation due to reaction with meteoric water before Cambrian burial, indicating that the altered granite was a paleosol before Paleozoic basinal fluid-flow events. Notably, the paleosol at the highest paleoelevation displays the least amount of paleoweathering and the paleosol at the lowest displays the greatest amount of paleoweathering. These results demonstrate that not only can characteristics of the paleosol just below the Great Unconformity be recognized in the St. Francois Mountains, despite subsequent alteration, but also it is possible to detect variations in soil thickness that were controlled by slope steepness and, therefore, water availability and/or soil creep or failure. This spatial relationship is compatible with studies of modern soils which indicate that soil character varies with position on a slope.

Geology↗

Reactive transport modeling of the Aquifer Thermal Energy Storage (ATES) system at Stockton University, New Jersey during seasonal operations

Hydrogeochemical processes associated with Aquifer Thermal Energy Storage (ATES) operations can often impact the system performance owing to mineral precipitation either at the wellbore or in the aquifer owing to changes in temperature and fluid disequilibria. Although failure of ATES systems due to mineral precipitation ("fouling") is common, predictive reactive-transport models have rarely been applied to plan their design and operation. Here, the objective of this study is to develop a reactive-transport model by coupling thermal, hydrological, and chemical (THC) processes to evaluate effects of introduced atmospheric oxygen on water chemistry, mineral precipitation/dissolution, porosity, and permeability changes associated with an ATES system at Stockton University (New Jersey, USA). The THC model builds on a Thermal-Hydrological-Mechanical (THM) model of the site that evaluated system failure owing to possible fracturing in the caprock or around the wellbore. The causes of the system failure are not known – potential causes include hydraulic fracturing owing to elevated pump pressures that took place, a flow pathway created by one of the boreholes, or a pre-existing natural hydrologic connection between the upper unconfined aquifer and the ATES aquifer, any of which could have led to oxygenated water entering the reservoir and causing the observed Fe-oxide fouling on well screens. The THC model is used to evaluate some of the hypotheses and observations regarding system failure owing to geochemical processes. The reactive-transport code TOUGHREACT V4 was used to model the THC processes during seasonal heating and cooling operations at the Stockton ATES site over 6 years of operation. In the THC simulations, the primary effects on geochemistry were observed when the injection water is saturated with atmospheric oxygen. Simulations show greater precipitation of goethite near the cold wells as compared to the warm wells. Although volume fractions of Fe-hydroxides were relatively small, the model was aimed at processes in the aquifer at the scale of meters and larger rather than at the scale of mm or cm (i.e., a well screen). Kaolinite is the dominant precipitating phase, also around the cold wells. Illite dissolves near the cold wells and precipitates near the warm wells. There is a net decrease in the porosity near the cold wells and increase near the warm wells, although a slight amount of thermal contraction near the cold wells and expansion near the warm wells is responsible for a significant proportion of the porosity change. Owing to the coarse discretization of the numerical grid near the wells (compared to the screen thickness) the magnitude of permeability changes at the wellbore are likely underestimated. The reactive transport model in this study can be used for characterization of aquifers, optimizing the operational parameters (temperature, pressure, pH etc.), and planning of mitigation strategies for ATES systems.

15 GEOTHERMAL ENERGY↗

Development, Monitoring, and Control of Fracture Thermal Energy Storage in Crystalline Rock Formations (DEMO-FTES) [Abstract]

Approximately half of global energy consumption is used for heating and cooling. Because fossil fuels are used to meet most of this demand, heating and cooling of buildings produces a large portion of global greenhouse gas (GHG) emissions. The proposed project seeks to demonstrate the feasibility of a seasonal thermal energy storage concept called fracture thermal energy storage (FTES), which has the potential to dramatically lower energy requirements for heating and cooling and improve the resilience of building energy systems. FTES is a technique for building a highly efficient heat exchanger by creating a carefully designed set of fractures in the ground below a building. This heat exchanger allows thermal energy to be stored over seasonal timeframes—for example, hot thermal energy that is easily captured in the summer or energy from waste heat sources—to meet heating needs during colder months. FTES offers a solution with a relatively small footprint and lower cost compared to currently operating aquifer thermal energy storage (ATES) systems and could be used in the many areas without aquifers suitable for ATES. If commercialized, FTES systems could exceed the 2.5 TWh of energy storage per year from the more than 2,800 ATES systems in operation worldwide, which range from 0.1 MW to 30 MW. The savings in CO2 emissions per year are also expected to match or exceed individual ATES projects, with the largest, a 30 MW system used to provide heating and cooling to the University of Technology in Eindhoven in the Netherlands, estimated to save 13,000 tons of CO2 emissions per year. FTES utilizes mature drilling and fracturing technology and therefore has the potential to be rapidly commercialized once demonstrated. The ability to construct and establish flow through an FTES heat exchanger has been demonstrated by a previous project and the potential for efficient, large-capacity energy storage has been shown using numerical models. However, no experimental validation of these numerical estimates of thermal energy storage has been made. The first crucial need to advance FTES technology is to identify the sensitivity of key metrics such as thermal energy storage and production rates, capacities, and efficiencies to design parameters such as the number of fractures, depth/temperature of fractures, size of fractures, and circulation rates. The second crucial need is experimental testing of achievable thermal performance with optimized system design parameters. The proposed scope of work seeks to systematically address these two critical needs through a highly complementary international collaboration spanning theory, laboratory, and mesoscale field evaluation. The proposed work plan calls for using dimensional analysis and existing state-of-the-art numerical simulators to design carefully scaled laboratory and 10-meter-scale field tests of the thermal efficiency of FTES. The existing advanced laboratory and intermediate-scale field testbeds that will be used for this project will allow for detailed monitoring of the system performance during the test and of how the performance changes across time and length scales. These results will determine the feasibility of full- scale FTES systems. If the thermal performance is consistent with model predictions, the results will provide a strong economic justification for rapid commercialization of FTES technology in a wide range of geographical areas.

25 ENERGY STORAGE↗