Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow meter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

GEER Status Update

History: The Glenn Extreme Environments Rig (GEER) first became operational in the early part of 2015. Since that time GEER has completed a number of scientific tests and has undergone improvements in the chemical delivery system and analytics following a year of operations experience. Recent Updates: In June 2016, the GEER process system was rebuilt to provide a more robust system, higher accuracy and new capabilities. New insulation was installed on the exterior of the pressure vessel and gas lines. The newly revamped GEER plumbing system can provide extremely precise custom gas mixtures using any gas desired by the investigator in any combination. GEER can heat the resulting mixture up to 500 deg C and 1500 psia. The 304 stainless steel vessel walls were polished to reduce corrosion rate and reduce unwanted chemical reactions. The process lines were replaced with high purity Sulfinert coated tubing. The GEER team added the ability to individually boost specialty gases to GEER thus allowing operators to make very precise changes to the gas chemistry inside of GEER during a test while at high temperature and pressure. High accuracy mass flow meters were added to further improve gas mixing accuracy and precision. An in-line, integrated Inficon MicroGC Fusion was added for real time gas analysis along with a high purity gas sampling system, providing fully automated, real time analysis of the gas chemistry inside of GEER in minutes. This complements a co-located mass spectrometer and both are used for regular monitoring of the vessel chemistry. All internal vessel components were replaced with polished 304SS equivalents. Hot vent down capability was increased. Finally, an automated liquid injection system was added and is rated for max vessel operating conditions of (1500 psia, 500 C). Recent Results and Publications: In May 2016, GEER completed a test that exposed high temperature electronics to Venus surface conditions for 21.5 days. This demonstrated the potential for operating robotic spacecraft in the Venus environment without the need for thermal or environmental protection. Results from this test were published in December 2016 and received national media attention. In April 2017 GEER implemented an 80 day test at Venus surface conditions to simulate chemical weathering of expected Venus minerals. This test supported a ROSES award to a team led by Prof. Ralph Harvey of Case Western Reserve University. The test concluded in July 2017 and nearly doubled previous operation record of 42 days at Venus surface conditions. Preliminary results of these and previous experiments were presented at the recent Venus Modeling Workshop. In June 2017, NASA TM2017-219437 "Chemical and Microstructural Changes in Metallic and Ceramic Materials Exposed to Venusian Surface Conditions" was published. This report provides an extensive and valuable resource detailing the behavior of a variety of engineering materials at Venus surface conditions. Community Involvement: An external science advisory panel has been formed.

Kremic, Tibor↗

Characterization of Thermal Protection Systems: An Analysis of Optical & Thermal Properties

Thermal Protection System Materials & thermal control coatings were characterized by a variety of methodologies including heat flow meter method (HFM), dynamic scanning calorimetry (DSC), fourier transform infrared spectroscopy (FTIR), and Ultra-Violet & Visible light spectroscopy (UV-VIS). Physical properties were measured to aid in the construction of thermal response models for a number a projects including MEDLI and MEDLI2. Comparing pre-flight predictions with actual flight data can allow for a reduction of margins and improve designs. The models enable design of TPS for flight missions and analysis of flight data to understand aerothermal environments experienced on the mission. This presentation reveals critical information: heat capacity (cp vs T), thermal conductivity ( vs T), and emissivity (E vs T) for Super Lightweight Ablative (SLA), Phenolic Impregnated Carbon Ablative (PICA-D), & Heatshield for Extreme Entry Environment Technology (HEEET). These properties were also measured for various thermal control coatings manufactured by AZ Technology. A portion of this work is incomplete and highlights questions to investigate in the future.

Cole, Brian↗

Evaluation of the Maximum Soluble Water Recovery from Pretreated Urine Brines in Low Earth Orbit

The Urine Processor Assembly (UPA) on the International Space Station recovers water from pretreated urine by thin-film, vacuum compression distillation (VCD). A number of iterative improvements to the distiller assembly (DA) have enabled increases in on-orbit water recovery and improved distillate water quality at on-orbit recoveries up to 87% by volume relative to the volume of pretreated urine. The phosphoric acid-based pretreatment formulation has enabled these higher recoveries on-orbit since May of 2016. Application of simple empirical chemistry models have allowed water recovery of sulfuric-acid pretreated urine from the Russian Orbiting segment to be distilled with phosphoric acid pretreated urine from the U.S. Orbiting Segment. Returned liquid brine from brine filters in the UPA brine loop have enabled empirical measurement of gypsum solubility as a function of recovery, conductivity, or mass density in the real brines of ISS. Calculations of maximum soluble recovery, MSR, are based on preventing the precipitation of gypsum, which is the first mineral to precipitate for both types of pretreated urine. A statistical urine model of urine composition provides an estimate of worst-case urine from a crew of three during one year of operations on ISS. The MSR is defined based on the worst-case concentrations of urinary calcium and urinary sulfate that are pretreated, pooled, and distilled. The potential to increase water recoveries above 87% without gypsum precipitation are evaluated. The potential benefits and costs of the addition of a conductivity sensor or a Coriolis mass flow meter to the brine loop are evaluated.

Dean L Muirhead↗

Experimental Investigation of a Phase Change Material Charged Serpentine Heat Exchanger with Louvered Fins

Phase change material heat exchangers (PCM-HX) can be used as a latent heat thermal energy storage (LHTES) component in heat pump applications to further enhance the efficiency of a heat pump as well as to yield financial savings by peak-load shifting. In this paper, a low-cost commercially available aluminum serpentine heat exchanger with louvered fins was experimentally investigated to check its thermal performance as a PCM-HX. A transparent rectangular box fabricated from acrylic plates served as a PCM container. Two cameras were used to capture the phase change process of the PCM on the front and top sides of the container during the experiment. A total of 88 installed temperature sensors throughout the test setup and a mass flow meter enabled a quantitative analysis of the PCM-HX as well. The energy balance deviation between the estimated theoretical and experimentally calculated PCM storage was ±14% considering the often-neglected heat loss and thermal mass of the PCM-HX. PCM temperature profiles, charge and discharge rates, and energy densities under different test conditions were also investigated.

42 ENGINEERING↗

Low flow vortex shedding flowmeter

The purpose was to continue a development project on a no moving parts vortex shedding flowmeter used for flow measurement of hypergols. The project involved the design and construction of a test loop to evaluate the meter for flow of Freon which simulates the hypergol fluids. Results were obtained on the output frequency characteristics of the flow meter as a function of flow rate. A family of flow meters for larger size lines and ranges of flow was sized based on the results of the tested meter.

Waugaman, Charles J.↗

Application of a laser interferometer skin-friction meter in complex flows

The application of a nonintrusive laser-interferometer skin-friction meter, which measures skin friction with a remotely located laser interferometer that monitors the thickness change of a thin oil film, is extended both experimentally and theoretically to several complex wind-tunnel flows. These include two-dimensional seperated and reattached subsonic flows with large pressure and shear gradients, and two and three-dimensional supersonic flows at high Reynolds number, which include variable wall temperatures and cross-flows. In addition, it is found that the instrument can provide an accurate location of the mean reattachment length for separated flows. Results show that levels up to 120 N/sq m, or 40 times higher than previous tests, can be obtained, despite encountering some limits to the method for very high skin-friction levels. It is concluded that these results establish the utility of this instrument for measuring skin friction in a wide variety of flows of interest in aerodynamic testing.

Monson, D. J.↗

Meter accurately measures flow of low-conductivity fluids

An electromagnetic flowmeter has been adjusted to minimize the errors inherent in measuring the flow of low conductivity fluids. This is done through use of a direct-coupled, differential cathode follower, whose grid potential is adjustable with respect to ground levels.

Love, E. G.↗

Local wall heat flux/temperature meter for convective flow and method of utilizing same

According to one embodiment of the invention, a method includes providing a conduit having a fluid flowing therethrough, disposing a plurality of temperature measurement devices inside a wall of the conduit, positioning at least some of the temperature measurement devices proximate an inside surface of the wall of the conduit, positioning at least some of the temperature measurement devices at different radial positions at the same circumferential location within the wall, measuring a plurality of temperatures of the wall with respective ones of the temperature measurement devices to obtain a three-dimensional temperature topology of the wall, determining the temperature dependent thermal conductivity of the conduit, and determining a multi-dimensional thermal characteristic of the inside surface of the wall of the conduit based on extrapolation of the three-dimensional temperature topology and the temperature dependent thermal conductivities.

Boyd, Ronald D.↗

Deployable Emergency Shutoff Device Blocks High-Velocity Fluid Flows

NASA's Marshall Space Flight Center has developed a device and method for blocking the flow of fluid from an open pipe. Motivated by the sea-bed oil-drilling catastrophe in the Gulf of Mexico in 2010, NASA innovators designed the device to plug, control, and meter the flow of gases and liquids. Anchored with friction fittings, spikes, or explosively activated fasteners, the device is well-suited for harsh environments and high fluid velocities and pressures. With the addition of instrumentation, it can also be used as a variable area flow metering valve that can be set based upon flow conditions. With robotic additions, this patent-pending innovation can be configured to crawl into a pipe then anchor and activate itself to block or control fluid flow.

Nabors, Sammy A.↗

Flow rate logging seepage meter

An apparatus for remotely measuring and logging the flow rate of groundwater seepage into surface water bodies. As groundwater seeps into a cavity created by a bottomless housing, it displaces water through an inlet and into a waterproof sealed upper compartment, at which point, the water is collected by a collection bag, which is contained in a bag chamber. A magnet on the collection bag approaches a proximity switch as the collection bag fills, and eventually enables the proximity switch to activate a control circuit. The control circuit then rotates a three-way valve from the collection path to a discharge path, enables a data logger to record the time, and enables a pump, which discharges the water from the collection bag, through the three-way valve and pump, and into the sea. As the collection bag empties, the magnet leaves the proximity of the proximity switch, and the control circuit turns off the pump, resets the valve to provide a collection path, and restarts the collection cycle.

Reay, William G.↗

P-107A hydrogen leak meter Final report

Flow improvement, mass flow calculations, matching cell factors, and temperature control of meter for hydrogen leakage measurements in liquid propulsion systems

MEASURING APPARATUS↗

Comparison of Inflation Processes at the 1859 Mauna Loa Flow, HI, and the McCartys Flow Field, NM

Basaltic lavas typically form channels or tubes during flow emplacement. However, the importance of sheet flow in the development of basalt ic terrains received recognition over the last 15 years. George Walke r?s research on the 1859 Mauna Loa Flow was published posthumously in 2009. In this paper he discusses the concept of endogenous growth, or inflation, for the distal portion of this otherwise channeldominated lava flow. We used this work as a guide when visiting the 1859 flow to help us better interpret the inflation history of the McCartys flow field in NM. Both well preserved flows display similar clues about the process of inflation. The McCartys lava flow field is among the you ngest (approx.3000 yrs) basaltic lava flows in the continental United States. It was emplaced over slopes of <1 degree, which is similar to the location within the 1859 flow where inflation occurred. Although older than the 1859 flow, the McCartys is located in an arid environ ment and is among the most pristine examples of sheet flow morphologies. At the meter scale the flow surface typically forms smooth, undula ting swales that create a polygonal terrain. The literature for simil ar features includes multiple explanatory hypotheses, original breakouts from adjacent lobes, or inflation related upwarping of crust or sa gging along fractures that enable gas release. It is not clear which of these processes is responsible for polygonal terrains, and it is po ssible that one explanation is not the sole cause of this morphology between all inflated flows. Often, these smooth surfaces within an inflated sheet display lineated surfaces and occasional squeeze-ups alon g swale contacts. We interpret the lineations to preserve original fl ow direction and have begun mapping these orientations to better interpret the emplacement history. At the scale of 10s to 100s of meters t he flow comprises multiple topographic plateaus and depressions. Some depressions display level floors with surfaces as described above, while some are bowl shaped with floors covered in broken lava slabs. Th e boundaries between plateaus and depressions are also typically smoo th, grooved surfaces that have been tilted to angles sometimes approaching vertical. The upper margin of these tilted surfaces displays lar ge cracks, sometimes containing squeeze-ups. The bottom boundary with smooth floored depressions typically shows embayment by younger lavas. It appears that this style of terrain represents the emplacement of an extensive sheet that experiences inflation episodes within prefer red regions where lateral spreading of the sheet is inhibited, thereby forming plateaus. Depressions are often the result of non-inflation and can be clearly identified by lateral squeeze-outs along the pit walls that form when the rising crust exposes the still liquid core of the sheet. Our current efforts are focused on.

Bleacher, Jacob E.↗

Guide to Flow Measurement for Electric Propulsion Systems

In electric propulsion (EP) systems, accurate measurement of the propellant mass flow rate of gas or liquid to the thruster and external cathode is a key input in the calculation of thruster efficiency and specific impulse. Although such measurements are often achieved with commercial mass flow controllers and meters integrated into propellant feed systems, the variability in potential propellant options and flow requirements amongst the spectrum of EP power regimes and devices complicates meter selection, integration, and operation. At the direction of the Committee on Standards for Electric Propulsion Testing, a guide was jointly developed by members of the electric propulsion community to establish a unified document that contains the working principles, methods of implementation and analysis, and calibration techniques and recommendations on the use of mass flow meters in laboratory and spacecraft electric propulsion systems. The guide is applicable to EP devices of all types and power levels ranging from microthrusters to high-power ion engines and Hall effect thrusters. The establishment of a community standard on mass flow metering will help ensure the selection of the proper meter for each application. It will also improve the quality of system performance estimates by providing comprehensive information on the physical phenomena and systematic errors that must be accounted for during the analysis of flow measurement data. This paper will outline the standard methods and recommended practices described in the guide titled "Flow Measurement for Electric Propulsion Systems."

spacecraft electric propulsion (EP) systems↗

Meter for very slow flows

Solid-state sensing unit developed for use with NASA's Water-Quality Monitoring System can detect small velocity changes in slow moving fluid. Nonprotruding sensor is applicable to numerous other uses requiring sensitive measurement of slow flows.

Baxter, W. J., Jr.↗

Remote semi-continuous flow rate logging seepage meter

The movement of groundwater and its associated solutes from upland regions was implicated in the degradation of receiving surface water bodies. Current efforts to directly measure this influx of water incorporate manually operated seepage meters which are hindered by severe limitations. A prototype seepage meter was developed by NASA Langley Research Center and Virginia Polytechnic Institute and State University that will allow for the semi-continuous collection and data logging of seepage flux across the sediment water interface. The meter is designed to operate at depths to 40 meters, and alleviate or minimize all disadvantages associated with traditional methods while remaining cost effective. The unit was designed to operate independently for time periods on the order of weeks with adjustable sample sequences depending upon hydrologic conditions. When used in conjunction with commercially available pressure transducers, this seepage meter allows for correlations to be made between groundwater discharge and tidal/sea state conditions in coastal areas. Field data from the Chesapeake Bay and Florida Bay systems are presented.

Reay, William G.↗

Seeing through flows in Langley's 0.3-meter Transonic Cryogenic Tunnel

Viewing problems associated with the measurement of model deformation in cryogenic wind tunnels are discussed. Tests were conducted in the Langley 0.3-Meter Transonic Cryogenic Tunnel to assess viewing capabilities thru the flow field. The effects of condensation and turbulent boundary layers are discussed and a modelling procedure for image degradation is described.

Snow, W. L.↗

Vortex-Shedding Meters For Liquid And Liquid/Gas Flows

Flowmeters without moving parts developed as replacements for conventional turbine flowmeters. No maintenance required so meters installed permanently. In vortex-shedding flowmeter, piezoelectric or other suitable transducer probe senses changes of pressure caused by passage of vortices. Electronic circuitry processes pressure-change signals to extract vortex-passage frequency representing rate of flow.

Howard, Robert H.↗