Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “field performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

High-Performance Thermoelectric Generators for Field Deployments

Thermoelectric power generation is a reliable energy harvesting technique for directly converting heat into electricity. Recent studies have reported the thermal-to-electrical energy conversion efficiency of thermoelectric generators (TEGs) up to 11% under laboratory settings. However, the practical effectiveness of TEGs deployed under real environments is still not more than a few percent. In this study, we provide fundamental insight on the operation of TEGs in realistic environments by illustrating the combinatory effect of thermoelectric material properties, device boundary conditions, and environmental thermal resistivity on TEG performance in conjunction with the module parameters. Using numerical and experimental studies, we demonstrate the existence of a critical heat transfer coefficient that dramatically affects the design and performance of TEGs. Results provide a set of concrete design criteria for developing efficient TEGs that meet the metrics for field deployments. High-performance TEGs demonstrated in this study generated up to 28% higher power and 162% higher power per unit mass of thermoelectric materials as compared to the commercial module deployed for low-grade waste heat recovery. This advancement in understanding the TEG operation will have a transformative impact on the development of scalable thermal energy harvesters and in realizing their practical targets for efficiency, power density, and total output power.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Narrowband Rejection of Reaction Wheel and Environmental Disturbances for the WFIRST OMC Testbed

The Wide Field Infrared Survey Telescope (WFIRST) is a NASA observatory with two scientific instruments. The first is the Wide Field Instrument (WFI) designed to perform wide field imaging and surveys of the near infrared (NIR) sky. The second is a coronagraph (CGI) that will enable astronomers to detect and measure properties of planets in other solar systems. The coronagraph requires 0.5 milli-arcsecond (mas) RMS pointing per axis of the line of sight (LOS) to achieve a contrast of 1x10-9. This paper discusses the approach used for achieving this level of pointing performance on the occulting mask coronagraph (OMC) testbed at JPL. This testbed uses a low-order wavefront sensing (LOWFS) camera and fast steering mirror (FSM) to suppress injected LOS jitter and environmental LOS jitter. The injected jitter includes representative broadband spacecraft attitude control system (ACS) LOS motion and tonal LOS jitter caused by the reaction wheel assemblies (RWA). The environmental jitter includes thermal LOS variations and harmonics of the line noise. The LOWFS camera uses high flux from the obscured science target to achieve high rate measurements of the LOS. These measurements are augmented with fictitious RWA tachometer information and an estimate of the line noise frequency. A LOS servo using a combination of feedback and feedforward control is used in the testbed to compensate for all of the disturbance sources and to mitigate jitter caused by in-band camera noise. The feedforward uses a novel robust least mean squares (RLMS) filter algorithm to reject the RWA and line frequency tones. High fidelity models of the sensors, disturbances and actuator are presented in this paper. These models were developed as part of a simulation of the LOS control system. Performance results from the hardware testbed at the Jet Propulsion Laboratory (JPL) are discussed in this paper.

Shields, Joel↗

The magnetic field of the earth - Performance considerations for space-based observing systems

Basic problems inherent in carrying out observations of the earth magnetic field from space are reviewed. It is shown that while useful observations of the core and crustal fields are possible at the peak of the solar cycle, the greatest useful data volume is obtained during solar minimum. During the last three solar cycles, the proportion of data with a planetary disturbance index of less than 2 at solar maximum was in the range 0.4-0.8 in comparison with solar minimum. It is found that current state of the art orbit determination techniques should eliminate orbit error as a problem in gravitational field measurements from space. The spatial resolution obtained for crustal field anomalies during the major satellite observation programs of the last 30 years are compared in a table. The relationship between observing altitude and the spatial resolution of magnetic field structures is discussed. Reference is made to data obtained using the Magsat, the Polar Orbiting Geophysical Observatory (POGO), and instruments on board the Space Shuttle.

Webster, W. J., Jr.↗

2024 Geothermal Rising Conference Poster

As part of a U.S. DOE Geothermal Technologies Office funding opportunity, Geysers Power Company, LLC, an indirect subsidiary of Calpine Corporation, partnered with Sandia National Labs, EGI at the University of Utah, and Texas A&M University to demonstrate increased drilling performance at The Geysers Geothermal Field. The performance target in the drilling demonstrations is at least a 25% improvement in rates of penetration with increased time on bottom for each bit. The planned drilling demonstrations are being conducted as part of an existing drilling campaign intended to enhance reservoir utilization. A major goal of the project is to assess the effectiveness of implementing mechanical specific energy (MSE) and drilling dysfunction diagnosis and remediation in these challenging environments, as well as alternate bit technologies. The first demonstration well has been completed, with a total of 15 PDC bit runs in the 17.5”, 12.25” and 8.5” sections. Initial analysis shows ROP gains in all three hole sections, especially in the 17.5” and 12.25” sections, compared with conventional roller cone bit runs in the demonstration well and offset wells. However in the 8.5” hole, wear and damage to the PDC bits resulted in relatively short bit runs. Analysis is underway to take advantage of the positive results and remediate the challenges.

15 GEOTHERMAL ENERGY↗

Evaluation of Physics-Based Limiter Redesign Drilling and Alternative Bit Design at The Geysers

As part of a U.S. DOE Geothermal Technologies Office funding opportunity, Geysers Power Company, LLC, an indirect subsidiary of Calpine Corporation, partnered with Sandia National Labs, EGI at the University of Utah, and Texas A&M University to demonstrate increased drilling performance at The Geysers Geothermal Field. The performance target in the drilling demonstrations is at least a 25% improvement in rates of penetration with increased time on bottom for each bit. The project will leverage advances in oil and gas drilling technologies including PDC bits, along with the physics-based limiter redesign techniques championed in drilling demonstrations conducted at the Utah FORGE geothermal site. The planned drilling demonstrations are being conducted as part of an existing drilling campaign intended to enhance reservoir utilization. The wells are typically drilled to the top of the reservoir with mud and then air-drilled to total depth (TD) through fractured zones at temperatures ≥ 450°F. A major goal of the project is to assess the effectiveness of implementing mechanical specific energy (MSE) and drilling dysfunction diagnosis and remediation in these challenging environments, as well as alternate bit technologies. The first demonstration well has been completed, with a total of 15 PDC bit runs in the 17.5”, 12.25” and 8.5” sections. Initial analysis shows ROP gains in all three hole sections, especially in the 17.5” and 12.25” sections, compared with conventional roller cone bit runs in the demonstration well and offset wells. However in the 8.5” hole, wear and damage to the PDC bits resulted in relatively short bit runs. Analysis is underway to take advantage of the positive results and remediate the challenges.

15 GEOTHERMAL ENERGY↗

Physics-Based Limiter Redesign and Bit Performance Analysis at The Geysers

As part of a U.S. DOE Geothermal Technologies Office funding opportunity, Geysers Power Company, LLC (GPC), an indirect subsidiary of Calpine Corporation, partnered with Sandia National Labs, EGI at the University of Utah, and Texas A&M University to demonstrate increased drilling performance at The Geysers Geothermal Field. The performance target in the drilling demonstrations is at least a 25% improvement in rates of penetration, with increased footage on bottom for each bit coupled with increased bit life and time drilling. The project leverages advances in oil and gas drilling technologies including PDC bits, along with the physics-based limiter redesign techniques championed in drilling demonstrations conducted at the Utah FORGE geothermal site. The planned drilling demonstrations are being conducted as part of an existing drilling campaign intended to enhance reservoir utilization. The wells are typically drilled to the top of the reservoir with mud and then air-drilled to total depth (TD) through fractured zones at temperatures ≥ 450°F. A major goal of the project is to assess the effectiveness of implementing mechanical specific energy (MSE) and drilling dysfunction diagnosis and remediation in these challenging environments, as well as alternate rock reduction technologies. The first demonstration well has been completed, with 15 PDC bit runs in the 17.5”, 12.25” and 8.5” sections. Initial analysis shows ROP gains in all three sections, especially in the 17.5” and 12.25” sections, compared with conventional roller cone bit runs in the demonstration well and offset wells. However, in the 8.5” hole, wear and damage to the PDC bits resulted in relatively short bit runs. Analysis is underway to take advantage of the positive results and remediate the challenges. This paper provides updates on drilling activities conducted since the Phase 1 demonstration well at GDC-36 which was drilled from November 2023-January 2024. Additional analysis of the bit performance has been conducted. Furthermore, in subsequent wells drilled by GPC, PDC bits have been used extensively, building on the gains realized at GDC-36. GPC has continued to work with bit vendors to identify designs that last longer in the harsh, air-drilled 8.5” portions of the wells. Planning for the Phase 2 demonstration at Prati-44 is ongoing.

15 GEOTHERMAL ENERGY↗

Field Test and Thermal Performance Comparison of a Novel Underground Thermal Battery with a Single U-tube Borehole Heat Exchanger for Geothermal Heat Pump Application

Geothermal Heat Pumps (GHP) are a proven technology to electrify and decarbonize space heating and cooling by utilizing the thermally consistent underground as a heat sink or source. However, the high drilling costs of conventional borehole heat exchangers (BHEs) associated with GHP systems and subsurface heterogeneity have been two major challenges to their widespread adoption. In this paper, we present results from a field-scale pilot of an Underground Thermal Battery (UTB) as a potential alternative to a conventional BHE. To benchmark the UTB performance, a side-by-side field test was conducted to compare the UTB with a conventional BHE installed at the same site. The UTB was installed in a 7.01-meter-deep borehole having a diameter of 0.9 meter, whereas the conventional BHE (with single U-tube loop) is in a borehole with 36.6-meter depth and 0.15-meter diameter. Both are integrated into a GHP system to meet the thermal energy demands of office space at the Illinois Energy Farm on the University of Illinois Urbana-Champaign campus. The system’s performance is compared in terms of heat transfer rate, outlet temperatures, and contributions to the overall thermal power of the GHP system under varying thermal demands and in different heat pump operation modes: heating only, cooling only, and hybrid (alternative, diurnal heating and cooling). Results to date indicate that the UTB delivers a more consistent response under during a time period of varying thermal demands. Its operational performance is better during short-term with higher thermal demands, while the conventional BHE performs better under continuous, long-term thermal demands.

Pokhrel, Sajjan [ORNL] (ORCID:0000000228523749)↗

HERMeS Thruster Magnetic Field Topology Optimization Study: Performance, Stability, and Wear Results

NASA's Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5kW Technology Demonstration Unit-1 (TDU-1) has been the subject of extensive technology maturation in preparation for flight system development. The TDU-1 thruster implements a magnetically shielded field topology and has demonstrated the elimination of the discharge channel erosion as a life limiting mechanism. Extensive wear testing the TDU Hall thrusters has identified the thruster front pole covers as the next life limiting component. This effort aims to explore and investigate alternate magnetic field topologies to assess whether reductions in the front pole cover erosion can be attained while still maintaining very low erosion rates on the discharge channel walls. Four candidate magnetic field topologies that reduce the effectiveness of the shielding along the discharge channel walls with the intent to also reduce the erosion rates along the front pole covers were designed. Three of the four candidate magnetic field topologies (B1, B2, and B4) have been manufactured and were subjected to an extensive test campaign that includes laser induced fluorescence (LIF), performance, stability, wear, plume, and thermal characterization. In Phase I, LIF measurements along the discharge chamber centerline found that upstream retraction of the thruster's peak magnetic field does result in an upstream shift of the acceleration zone but the magnitude of the shift does not correspond one-to-one to the shift in the location of the peak radial magnetic field magnitude. Phase II test segment results found at a normalized thruster magnetic field setting of 1, the thruster performance was very similar for all configurations. Discharge current waveforms ripple data indicated that configurations Bo, B1, and B2 has similar oscillatory profiles with the B2 configuration transitioning to higher oscillatory mode at 400V instead of the 450V observed for configurations B0 and B1. Configuration B4 ripple data indicates that the thruster was operating in a very oscillatory mode above 350V. Inner front pole cover erosion rates for configuration B1 were approximately 65% relative to B0 and the erosion rates for configuration B2 were 40% relative to B0. Analysis of the performance, stability, and wear test results of configurations B0, B1, B2, and B4 indicates that configuration B2 may present an alternative option for B0 because it mostly maintained the same performance and stability as configuration B0 but with 40% of the inner front pole cover erosion rate.

Kamhawi, Hani↗

Improved performance of a near-field thermophotovoltaic device by a back gapped reflector

Various spectral control techniques can be applied to improve the performance of a thermophotovoltaic (TPV) device. For example, a back surface reflector (BSR) is a common structure to improve the performance of TPV devices. A conventional metal BSR structure enhances the photogeneration rate by increasing the absorption probability of photons via back surface reflections, affording a second chance for absorption. However, the effects of surface passivation and external luminescence introduced by BSR structures have been previously ignored, which potentially decreases the performance of TPV devices. Recently, a back gapped reflector (BGR) structure was proposed to greatly improve the performance of far-field TPV devices by reducing imperfect reflections at the semiconductor-metal interface. In the present work, the performance improvement on a thin-film, near-field InAs TPV device with a BGR is investigated, comparing its performance to that with a conventional metal BSR. Surface passivation conditions are also investigated to further improve the performance of TPV devices with back reflectors. Further, the output power and efficiency are calculated using an iterative model combining fluctuational electrodynamics and the full drift diffusion model. For the well-passivated condition, when the BSR is replaced by the BGR, the calculated conversion efficiency of the near-field TPV was improved from 16.4% to 21% and the output power was increased by 10%. Finally, the absorption of the back reflectors and external luminescence loss are analyzed to explain the performance improvement.

external luminescence↗

Effect of field of view on performing a low altitude maneuvering task

Visual systems with a single window display are often utilized in ground based simulators used to study helicopter flying qualities during visual low altitude maneuvering tasks. The effects of this limited field of view (FOV) on pilot assessments of flying qualities are uncertain. A study was conducted using a variable stability UH-1H helicopter to compare restricted and unrestricted FOV for a range of flying qualities. With the restricted FOV, the pilots reported reduced ground track precision owing to loss of visual contact with the course markers. However, the predictable ground track of the repeated S-turn task with no obstacles made it easy for them to anticipate their maneuvers, and resulted in only a slight degradation of pilot ratings. This degradation was not sensitive to large changes in helicopter flying qualities.

Carico, Dean↗

Low-field-orientation effect on REBCO tape performance and its power cable application

Low field characteristics, including field orientation dependence relations for four different commercially available REBCO tapes, were investigated in an external field of up to 0.3 T at 77 K. A design method of the performance of a twisted stacked-tape conductor (TSTC) has been developed for a power transmission line. Cable critical current is obtained from an averaged self-field distributed over the cable cross section and the minimum critical current obtained from the field orientation dependence in transverse fields experimentally measured for the single tapes. The performance of three types of TSTCs, i.e., single-, double-, and triple-channel configurations, has been assessed for the four REBCO tapes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Navier-Stokes predictions of multifunction nozzle flows

A two-dimensional, Navier-Stokes code developed by Imlay based on the implicit, finite-volume method of MacCormack has been applied to the prediction of the flow fields and performance of several nonaxisymmetric, convergent-divergent nozzles with and without thrust vectoring. Comparisons of predictions with experiment show that the Navier-Stokes code can accurately predict both the flow fields and performance for nonaxisymmetric nozzles where the flow is predominantly two-dimensional and at nozzle pressure ratios at or above the design values. Discrepancies between predictions and experiment are noted at lower nozzle pressure ratios where separation typically occurs in portions of the nozzle. The overall trends versus parameters such as nozzle pressure ratio, flap angle, and vector angle were generally predicted correctly.

Wilmoth, Richard G.↗

The New LOTIS Test Facility

The Large Optical Test and Integration Site (LOTIS) at the Lockheed Martin Space Systems Company in Sunnyvale, CA is designed for the verification and testing of optical systems. The facility consists of an 88 foot temperature stabilized vacuum chamber that also functions as a class 10k vertical flow cleanroom. Many problems were encountered in the design and construction phases. The industry capability to build large chambers is very weak. Through many delays and extra engineering efforts, the final product is very good. With 11 Thermal Conditioning Units and precision RTD s, temperature is uniform and stable within 1oF, providing an ideal environment for precision optical testing. Within this chamber and atop an advanced micro-g vibration-isolation bench is the 6.5 meter diameter LOTIS Collimator and Scene Generator, LOTIS alignment and support equipment. The optical payloads are also placed on the vibration bench in the chamber for testing. This optical system is designed to operate in both air and vacuum, providing test imagery in an adaptable suite of visible/near infrared (VNIR) and midwave infrared (MWIR) point sources, and combined bandwidth visible-through-MWIR point sources, for testing of large aperture optical payloads. The heart of the system is the LOTIS Collimator, a 6.5m f/15 telescope, which projects scenes with wavefront errors <85 nm rms out to a 0.75 mrad field of view (FOV). Using field lenses, performance can be extended to a maximum field of view of 3.2 mrad. The LOTIS Collimator incorporates an extensive integrated wavefront sensing and control system to verify the performance of the system.

Bell, R. M.↗

Imposing equilibrium on experimental 3-D stress fields using Hodge decomposition and FFT-based optimization

Here, we present a methodology to impose micromechanical constraints, i.e. stress equilibrium at grain and sub-grain scale, to an arbitrary (non-equilibrated) voxelized stress field obtained, for example, by means of synchrotron X-ray diffraction techniques. The method consists in finding the equilibrated stress field closest (in L 2 -norm sense) to the measured non-equilibrated stress field, via the solution of an optimization problem. The extraction of the divergence-free (equilibrated) part of a general (non-equilibrated) field is performed using the Hodge decomposition of a symmetric matrix field, which is the generalization of the Helmholtz decomposition of a vector field into the sum of an irrotational field and a solenoidal field. The combination of: a) the Euler–Lagrange equations that solve the optimization problem, and b) the Hodge decomposition, gives a differential expression that contains the bi-harmonic operator and two times the curl operator acting on the experimental stress field. These high-order derivatives can be efficiently performed in Fourier space. The method is applied to filter the non-equilibrated parts of a synthetic piecewise constant stress fields with a known ground truth, and stress fields in Gum Metal, a beta-Ti-based alloy measured in-situ using Diffraction Contrast Tomography (DCT). In both cases, the largest corrections were obtained near grain boundaries.

36 MATERIALS SCIENCE↗

Status and Performance of HST Wide Field Camera 3

The HST Wide Field Camera 3 is a panchromatic UV-visible-near infrared camera whose development is currently nearing completion, for a planned installation into the Hubble Space Telescope during Servicing Mission 4. WFC3 provides two imaging channels. The UVIS channel features a 4096 x 4096 pixel CCD focal plane with sensitivity from 200 to 1000 nm and a 160 x 160 arcsec field of view. The UVIS channel provides unprecedented sensitivity and field of view in the near ultraviolet for HST. The IR channel features a 1014 x 1014 pixel HgCdTe focal plane covering 850 to 1700 nm with a 135 x 135 arcsec field of view, providing a substantial advance in IR survey efficiency for HST. The construction of WFC3 is nearly complete, and the instrument is well into its integration and test program. We present the current status of the instrument and its projected scientific performance when installed into HST.

Kimble, Randy↗

Measurement Techniques for the High-Contrast and in-Field Stray-Light Performance of Oci

Scheduled for launch in January 2024, the PACE mission represents NASA’s next investment in ocean biology, clouds, and aerosol data records [1]. A key feature of PACE is the inclusion of an advanced satellite radiometer known as the Ocean Color Instrument (OCI), a global mapping radiometer that combines multispectral and hyperspectral remote sensing. A critical requirement for OCI is the high-contrast or spatial cross-talk specification (also referred to as in-field stray-light response). The requirement states that for global top-of-atmosphere radiances based on measured MODIS radiances, the global average residual contamination shall be less than 0.15% for any multispectral band. Accurate resolution of high contrast in TOA radiance images is important to estimate stray light contamination due to clouds, for studying small scale features like ocean fronts and for working in coastal and estuarine areas where the scales are 1km. This occurs in all wavelengths in the spatial direction. Knowledge of high contrast resolution makes up part of the artifact budget. Accurate measurement of the high-contrast performance of OCI requires laboratory Ground Support Equipment (GSE) that projects a scene of sufficient quality that the unwanted stray light of the GSE itself is not confused with the stray light response of the telescope. This paper concerns the development, analyses and test of the GSE to ensure the quality of the projected image is sufficient to verify the OCI requirements. Optical models were developed for both the instrument as well as the GSE and laboratory environment. Simulation of various non-ideal parameters were critical to accurately predict performance. Measurements using COTS cameras and lenses were also made of the projected GSE image to reasonably verify the optical model predictions. Measured and modelled results from OCI are discussed.

OCI↗

Measurement Techniques for the High-Contrast and in-Field Stray-Light Performance of OCI

Scheduled for launch in January 2024, the PACE mission represents NASA’s next investment in ocean biology, clouds, and aerosol data records [1]. A key feature of PACE is the inclusion of an advanced satellite radiometer known as the Ocean Color Instrument (OCI), a global mapping radiometer that combines multispectral and hyperspectral remote sensing. A critical requirement for OCI is the high-contrast or spatial cross-talk specification (also referred to as in-field stray-light response). The requirement states that for global top-of-atmosphere radiances based on measured MODIS radiances, the global average residual contamination shall be less than 0.15% for any multispectral band. Accurate resolution of high contrast in TOA radiance images is important to estimate stray light contamination due to clouds, for studying small scale features like ocean fronts and for working in coastal and estuarine areas where the scales are 1km. This occurs in all wavelengths in the spatial direction. Knowledge of high contrast resolution makes up part of the artifact budget. Accurate measurement of the high-contrast performance of OCI requires laboratory Ground Support Equipment (GSE) that projects a scene of sufficient quality that the unwanted stray light of the GSE itself is not confused with the stray light response of the telescope. This paper concerns the development, analyses and test of the GSE to ensure the quality of the projected image is sufficient to verify the OCI requirements. Optical models were developed for both the instrument as well as the GSE and laboratory environment. Simulation of various non-ideal parameters were critical to accurately predict performance. Measurements using COTS cameras and lenses were also made of the projected GSE image to reasonably verify the optical model predictions. Measured and modelled results from OCI are discussed.

OCI, PACE, LSF, PSF, Stray-light, Contrast, Cross-↗