Engineering PapersSearch

SEARCH · Engineering Papers

Results for “field measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

876 records · Page 11

Global Precipitation Measurement (GPM) Spacecraft Lithium Ion Battery Micro-Cycling Investigation

The Global Precipitation Measurement (GPM) spacecraft was jointly developed by NASA and JAXA. It is a Low Earth Orbit (LEO) spacecraft launched on February 27, 2014. The power system is a Direct Energy Transfer (DET) system designed to support 1950 watts orbit average power. The batteries use SONY 18650HC cells and consist of three 8s by 84p batteries operated in parallel as a single battery. During instrument integration with the spacecraft, large current transients were observed in the battery. Investigation into the matter traced the cause to the Dual-Frequency Precipitation Radar (DPR) phased array radar which generates cyclical high rate current transients on the spacecraft power bus. The power system electronics interaction with these transients resulted in the current transients in the battery. An accelerated test program was developed to bound the effect, and to assess the impact to the mission.

Lithium Ion Battery Performance

Experimental Effervescence and Freezing Point Depression Measurements of Nitrogen in Liquid Methane-Ethane Mixtures

NASA is designing an unmanned submarine to explore the depths of the hydrocarbon-rich seas on Saturn’s moon Titan. Data from Cassini indicates that the Titan north polar environment sustains stable seas of variable concentrations of ethane, methane, and nitrogen, with a surface temperature near 93 K. The submarine must operate autonomously, study atmosphere/sea exchange, interact with the seabed, hover at the surface or any depth within the sea, and be capable of tolerating variable hydrocarbon compositions. Currently, the main thermal design concern is the effect of effervescence on submarine operation, which affects the ballast system, science instruments, and propellers. Twelve effervescence measurements on various liquid methane-ethane compositions with dissolved gaseous nitrogen are thus presented from 1.5 bar to 4.5 bar at temperatures from 92 K to 96 K to simulate the conditions of the seas. After conducting effervescence measurements, two freezing point depression measurements were conducted. The freezing liquid line was depressed more than 15 K below the triple point temperatures of pure ethane (90.4 K) and pure methane (90.7 K). Experimental effervescence measurements will be used to compare directly with effervescence modeling to determine if changes are required in the design of the thermal management system as well as the propellers.

Freezing Point Depression

SCOAPE-II: A 2024 Multiplatform Measurement Campaign off the US Gulf Coast to Assess Oil and Gas Emissions on the Outer Continental Shelf

Nine years ago, the Department of Interior’s Bureau of Ocean Energy Management (BOEM), the Agency with Air Quality (AQ) jurisdiction over the Outer Continental Shelf (OCS) of the US Gulf Coast west of 87.5° W longitude, asked NASA to determine the feasibility of using satellite data to measure offshore emissions in a region of concentrated oil and natural gas (ONG) operations. To study this issue NASA and BOEM conducted the May 2019 Satellite Coastal and Oceanic Atmospheric Pollution Experiment (SCOAPE) cruise in the Gulf. SCOAPE addressed both technological and scientific issues related to measuring nitrogen dioxide (NO 2 , a common air pollutant), including contrasting near-shore and deepwater regimes. Given the April 2023 launch of the geostationary Tropospheric Emissions: Monitoring of Pollution (TEMPO) AQ satellite, a 2024 SCOAPE-II was conducted in the Gulf with both ship and aircraft measurements. We present an overview of the SCOAPE-II campaign, analysis and validation of satellite-observed NO 2 , and evaluate measurements of methane from ship, aircraft, and satellite near ONG platforms. Our SCOAPE-II results are as follows: 1) Satellite NO 2 measurements (∼13:30 local time) from the TROPOspheric Monitoring Instrument (TROPOMI) are more accurate than TEMPO’s hourly scans (8.6% vs. 23.6% mean absolute bias); a new version of TEMPO data is currently being processed; 2) ship and aircraft measurements captured dozens of NO 2 and methane plumes from ONG operations, showing that they are persistent emitters; 3) satellite measurements of methane failed to replicate ship and aircraft measurements, presenting ongoing challenges for operational emissions monitoring over the Gulf.

satellite validation

In-Flight Calibration of ESA Hera’s Hyperscout-H Imager

ESA’s Hera space mission is on its way to the mission target, the binary asteroid (65803) Didymos. HyperScout-H, one of the instruments onboard Hera, is a hyperspectral imager operating in the visible and near-infrared regions between 0.65 and 0.95 μm. HyperScout-H will enable a detailed assessment of the composition of both objects, Didymos and its satellite Dimorphos, the characterization of space weathering effects, and the possible presence of exogenous material on their surfaces. To monitor instrument functionality, calibration exposures are acquired regularly. This article describes the in-flight calibrations carried out for HyperScout-H during the commissioning and cruise phases. Bias and dark exposures, as well as stellar field observations, were acquired several times after launch. We update the calibration data and monitor instrument performance in the space environment. In addition, images of Earth and Moon were acquired from distances of 1.5 × 10 6 to 2.0 × 10 6 km, and Mars and its satellite were imaged during the flyby. In five images, the surface of Mars fills the entire field of view, enabling cross-validation of HyperScout-H results with those reported by other Mars missions. We characterize the detector under in-flight operational conditions. The calibration data indicate that the bias pattern is stable, the dark current remains negligible for short exposures, and the detector response is highly linear. We quantify the field-of-view alignment and geometric distortion, and evaluate the point spread function based on the stellar field observations. Stellar observations and Mars swing-by data provide updated radiometric calibration constants, suggesting that in-flight conditions have slightly modified the detector’s spectral response. In-flight calibrations are essential to ensure data quality and reliability.

Image Processing

Magnetic brightening and nanoscale imaging of spin-polarized helical edge modes in ZrTe 5

Efficient charge transport remains a fundamental challenge for nanoelectronic devices, as their performance is constrained by high dissipation and the impedance mismatch between high-frequency signal sources and nanoscale circuit interfaces. Although topologically protected helical edge modes offer a dissipationless and backscattering-resilient alternative, achieving nanoscale control over these modes requires direct visualization of their spatial electrodynamics, especially under high-frequency operation. Here, by utilizing cryogenic magneto-infrared scattering-type scanning near-field optical microscopy (cm-IR-sSNOM), we image spin-polarized helical edge channels in ZrTe 5 at the nanoscale, revealing magnetic-field-induced brightening as a high-frequency electrodynamic signature of robust topological edge modes. Operating at 1.8 K and under a magnetic field of up to 5 T, we observe the emergence of edge-state polarizability at infrared frequencies that is notably resilient to the magnetic gaps that typically quench d.c. and microwave edge transport. Our results reveal a topological ‘two-lane’ spatial reorganization in which an external magnetic field induces a spin-population imbalance between counterpropagating edge modes. Favoured helical branches are confined against physical boundaries to activate a net infrared near-field contrast. This electrodynamic response scales linearly with the number of atomic layers, which confirms that individual layers in ZrTe 5 preserve their discrete quantum spin Hall identities. These findings may be useful for developing topological spintronic devices, as the magnetic infrared tunability of helical edge channels provides a pathway for low-loss nanoscale interconnects and high-speed information processing.

36 MATERIALS SCIENCE

Squeezing quantum states in three-dimensional twisted crystals

Bloch's theorem provides a conventional starting point for describing wave propagation in periodic media, but in ordered materials where competing spatial periods coexist it is rendered ineffective, often with dramatic consequences. Here we develop an alternate approach that uses coherent free-particle vortex states to study quantum states in supertwisted crystals: three-dimensional stacks of atomically thin two-dimensional layers. Here, this formalism leads naturally to the representation of the spectrum using squeezed coherent states, and it reveals the crucial role of a Coriolis coupling in the equations of motion. This identifies an underlying noncommutative geometry and novel edge state structure in a family of complex ordered structures.

36 MATERIALS SCIENCE

The ABCs of phase retrieval: Connecting the acronyms of scanning transmission electron microscopy

High-resolution scanning transmission electron microscopy (S/TEM) is an indispensable tool for characterizing the structure and properties of materials down to the atomic scale. Conventional S/TEM imaging, however, is limited by the phase problem, whereby the phase of the electron exit wave is lost upon detection. Recent advances in diffractive imaging and 4D-STEM have enabled a range of phase-retrieval techniques that computationally reconstruct the missing information encoded in the phase of the transmission function. These approaches offer improved dose efficiency and enhanced sensitivity to weakly scattering signals, extending quantitative imaging to beam-sensitive materials composed of light elements. In this work, we introduce the phase problem in electron microscopy and survey the diverse landscape of phase-retrieval techniques used in the field. Despite their many acronyms and algorithmic variations, these techniques share a common physical and mathematical foundation. We present a unified framework that connects these seemingly distinct methods, from parallax imaging and tilt-corrected bright-field (tcBF-STEM), to aberration-corrected bright-field (acBF-STEM), optimum bright-field (OBF-STEM) and single-sideband (SSB) ptychography, as well as first-moment integrated center of mass techniques (iCOM) and iterative ptychographic algorithms. Based on these insights, we discuss the opportunities and practical limitations of applying these methods across different materials systems, detector designs, and microscope configurations.Graphical abstractRepresentative electron microscopy configurations used for phase retrieval and diffractive imaging in S/TEM: (a) Zernike phase-contrast transmission electron microscopy (TEM), (b) small-convergence-angle four-dimensional scanning transmission electron microscopy (4D-STEM) for nanobeam-based phase reconstruction methods, and (c) large-convergence-angle 4D-STEM for ptychographic and related diffractive imaging techniques reviewed in this work.

36 MATERIALS SCIENCE

Elastic Modulus Measurement at High Temperatures for Miniature Ceramic Samples Using Laser Micro-Machining and Thermal Mechanical Analyzer

In this paper, we demonstrate a method of measuring the flexural elastic modulus of ceramics at an intermediate (~millimeter) scale at high temperatures. We used a picosecond laser to precisely cut microbeams from the location of interest in a bulk ceramic. They had a cross-section of approximately 100 μm × 300 μm and a length of ~1 cm. They were then tested in a thermal mechanical analyzer at room temperature, 500 °C, 800 °C, and 1100 °C using the four-point flexural testing method. We compared the elastic moduli of high-purity Al2O3 and AlN measured by our method with the reported values in the literature and found that the difference was less than 5% for both materials. This paper provides a new and accurate method of characterizing the high-temperature elastic modulus of miniature samples extracted from representative/selected areas of bulk materials.

Chemistry

Mechanisms of Protonic Nonvolatile Memory Device

A nonvolatile memory device based on protonic transport in oxides has been proposed. The mobile H+ ions are introduced into the SiO2 layer by annealing Si/SiO2/Si structures in H2 at temperatures greater than 500 deg C. This effect has only been observed for confined oxides that have been annealed at greater than or equal to 1100 C prior to the hydrogenation anneal. This includes buried oxides such as Unibond and SIMOX as well as thermal oxides annealed with a polysilicon cap. An applied field moves the charge within the oxide and the charge stops moving when the field is removed. In a memory device, the hydrogen-annealed oxide is the gate oxide and the position of the mobile charge is sensed by the shift of the I-V curve. Much is still not understood about the motion of the charge across the buried oxide. Previous work has assumed that H+ transport and the time it takes to traverse the oxide is governed by interactions within the bulk of the oxide. Based on parameters that affect the transport time, we conclude that H+ trapping and detrapping at the Si/SiO2 interface are more important than H+ interactions within the oxide bulk. These parameters include the applied field, the H+ concentration and the oxide thickness. One consequence is that projections of device write-time based on the previous assumptions of H+ transport mechanisms may be overly optimistic.

P J Macfarlane

Proceedings of the 25th International Instrumentation Symposium, May 7-10, 1979, Anaheim, California

The papers deal essentially with the instrumentation needs of the transportation industry, machinery diagnostics, and energy research. The sessions covered include: acoustic emission, reentry vehicle ground and flight testing, performance of nose tip materials, instrumentation for solar heating and cooling systems, vibration measurement, data acquisition and analysis, system for aerospace pressure measurements, wind tunnel instrumentation and control, energy source instrumentation, nondestructive testing, pressure and flow measurements, automated test facilities, strain measurements, electrooptical instrumentation, thermal measurements, microcomputer applications in instrumentation and automation, flight testing, blast pressure measurement, two-phase liquid/gas mass flow measurement, and machinery monitoring and instrumentation.

Conferences

Harness Thermal Heat Loss Measurement for a Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

TVAC

Harness Thermal Heat Loss Measurement for A Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

Thermal

Harness Thermal Heat Loss Measurement for A Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

TVAC

Advanced Non-Intrusive Instrumentation for Propulsion Engines

Changes in engine technology such as higher temperatures, higher tip speeds, new metal/composite/ceramic materials together with radical changes in design philosophy will require amongst other prerequisites the ability to measure and to monitor key internal gas and structural characteristics. The symposium papers presented non-intrusive measurement and analysis technologies in the following categories: Laser Point Measurements (11); Absorption and Infrared Techniques (4); Paints - Surface Sensors (6); Laser Induced Fluorescence (6); Mechanical (7); Films (5); Laser Planar Measurement (9); and a Keynote Address.

Propulsion

Laser–plasma amplification of an ultrabroadband laser pulse to 0.3 TW

Producing on-target laser intensities much greater than 10 23 W cm −2 with current laser technologies is a roadblock to accessing new regimes of physics such as strong-field quantum electrodynamics. Laser–plasma amplifiers show promise to realize these intensities by augmenting the final amplifier and compressor in traditional chirped-pulse-amplification architectures with a plasma-based amplification and compression stage that operates at a much higher damage threshold. Here we demonstrate amplification of an ultrabroadband (>60 nm) pulse in a laser–plasma Raman amplifier. We directly amplified seed intensities up to 3.7 × 10 15 W cm −2 and measured efficiencies up to 8.7%. Single-shot SPIDER measurements show a factor-of-2 reduction in the amplified pulse duration with final powers up to 0.3 TW, a 10× improvement over previous results. Final pulse durations of 64 fs are measured. Energy transfers greater than 220 mJ from the picosecond pump into the seed result in a 30× energy amplification of a 7.6 mJ seed. These results set the stage for a compact plasma afterburner based on Raman amplification that could extend the scientific capability of existing petawatt-class laser facilities to enable experiments at the intensity frontier.

Shaw, J. L. [Univ. of Rochester, NY (United States

Microgravity Effects on Standardized Cognitive Performance Measures

The purpose of this experiment, selected to fly on the International Microgravity Laboratory (IML-2) Spacelab mission, is to determine the effects of microgravity upon the cognitive skills which are critical to successful performance of many tasks on board the Space Shuttle. Six tests from the Unified Tri-service Cognitive Performance Assessment Battery (UTC-PAB) will be administered to the Mission Specialists to fulfill the goals of this experiment. These tests are based upon current theoretical models of human performance and the hypothesized effects of microgravity. The principle objective is the identification of the effects of microgravity upon specific information processing skills affecting performance from those of fatigue and shifts in work/rest cycles. Multiple measures of both short and long term fatigue will be obtained and used as a major independent variable for the analysis of these performance data. Scientific supporting studies will determine optimum practice and performance testing schedules for the astronauts. The same tests will be used post-flight to collect data on the recovery of any cognitive performance impairment compared with pre-flight, baseline levels.

Samuel G Schiflett