County Land-Use Regulations for Solar Energy Development in Colorado

We present a survey of county-level policies on ground-mounted solar development across Colorado, including both solar-specific ordinances as well as general land-use code that might be applicable in counties without solar-specific policies. This report provides an accessible reference for stakeholders interested in identifying counties with particular regulations or in analyzing the diversity of regulations across Colorado. We defined a set of search criteria to find information on solar definitions and classifications, permitting processes, and use-specific requirements in each of Colorado's 64 counties. With those criteria, we reviewed relevant ordinances, land-use code, and comprehensive and master plans. If any uncertainties were identified, we contacted county officials for clarification. The findings are categorized and mapped to illustrate the distribution of key policies adopted across Colorado's counties on the following topics: solar definitions, solar siting policy documentation, categorization of PV systems for permitting, 1041 permitting, solar on agricultural land, panel height restrictions, fencing requirements, vegetation management, visual impacts, decommissioning plans, and financial assurance for decommissioning. Additionally, we identify and discuss policies that might impact the deployment of agrivoltaics, a dual land use combining both agriculture and solar on the same land, which might not fit neatly in existing zoning definitions and solar-specific regulations.

14 SOLAR ENERGY↗

Eligibility Assessment of Items in the TA-60 Rack Assembly and Alignment Complex Legacy Storage Yard

The U.S. Department of Energy, National Nuclear Security Administration, Los Alamos Field Office (NA-LA), documented and evaluated seven structures in the Technical Area 60 (TA-60) Rack Assembly and Alignment Complex (RAAC) legacy storage yard at Los Alamos National Laboratory (LANL or Laboratory) for listing in the National Register of Historic Places (National Register). This documentation and evaluation was conducted in compliance with Section 106 of the National Historic Preservation Act of 1966, as amended; the Code of Federal Regulations (36 CFR 800); the Programmatic Agreement among the U.S. Department of Energy, National Nuclear Security Administration, Los Alamos Field Office, the New Mexico State Historic Preservation Office and the Advisory Council on Historic Preservation Concerning Management of the Historic Properties at Los Alamos National Laboratory, Los Alamos New Mexico (PA)1; and A Plan for the Management of the Cultural Heritage at Los Alamos National Laboratory, New Mexico (LANL’s Cultural Resources Management Plan (2017). NA-LA makes the following National Register eligibility determinations: la cuna; the rack transporter (jeep, rack trailer, and steering dolly); the Mexia diagnostic rack; the Mexia device canister; the Mexia device mounting stand; and the Mexia target stand are eligible for listing in the National Register, and the second steering dolly is not eligible for listing in the National Register. This National Register evaluation was completed because LANL proposes to develop a consolidated waste facility in TA-60 next to the former RAAC. Across 3.56 acres, LANL proposes to construct an 8,000-square-foot, pre-engineered waste storage building; a 1,500-square-foot office/warehouse building; and 28,500 square feet of covered storage. The development will also include access control features and fencing, parking spaces, and utilities. Additionally, the Laboratory will continue to use the southern part of TA-60-0017 and reuse TA-60-0086 and TA-60-0324 in the development. The consolidated waste facility will operate as a central accumulation area—storing universal waste, mixed low-level (radioactive) waste, hazardous chemicals, and New Mexico special waste—until the waste can be shipped off site.

99 GENERAL AND MISCELLANEOUS↗

Economically Viable Intermediate to Long Duration Hydrogen Energy Storage Solutions for Fossil Fueled Assets

This report was prepared as an account of work sponsored by the Office of Fossil Energy and Carbon Management of U.S. Department of Energy under Funding Opportunity Announcement Number DE-FOA-0002332 “Energy Storage for Fossil Power Generation”. The work aimed to explore and advance an innovative hydrogen energy storage system – the synergistically integrated hydrogen energy storage system (SIHES) – that has the following characteristics: • Compatible with existing or new coal and gas fuel electricity generation units, • best suited for intermediate to long duration energy storage, from 12 hours to weeks even months, and • capable of storing energy at the utility scale – hundreds of MWh to GWh energy storage with power output level in tens to hundreds of MW. Preliminary front-end engineering design (Pre-FEED) studies was carried out to develop and refine a site-specific SIHES as peaking power generation units (so named as HyPeaker) as the first market entry point, to demonstrate both the technical feasibility and the economic viability to integrate the HyPeaker “within the fence” of a fossil power plant. This specific site was TVA’s Johnsonville Combustion Turbine Plant. The HyPeaker was designed and engineered to integrate with a 60MW aeroderivative gas turbine unit already available at TVA’s Johnsonville site. This site-specific HyPeaker consists of an alkaline electrolyzer to produce hydrogen from CO 2 free electricity sources, an innovative low-cost high-pressure hydrogen storage system (Big-Ton) and the aero gas turbine to generate electricity using blend of hydrogen and natural gas. A holistic system level technoeconomic analysis tool specific to HyPeaker was developed to optimize the engineering design of the Johnsonville site-specific HyPeaker for cost and performance. The optimal design and specification of the Johnsonville site-specific HyPeaker are the following: • Alkaline electrolyzer: 3MW • Big-Ton storage vessel: 11,000kg H 2 at 3000psi. • 4-stage diaphragm hydrogen compressor: 55kg-H 2 /hr from 150psi to 3000psi. The HyPeaker is designed to provide sufficient hydrogen for 90% continuous operation of the HyPeaker. All major components have design life of 30 years. The capex of HyPeaker is estimated at $\$$7.1M. This included $\$$1.5M for the electrolyzer, $\$$5.6M for the storage vessel and compressor. The cost of aero gas turbine was included as it is already available at the site. Key findings are: • HyPeaker can be designed, manufactured, installed and integrated with the fossil power plants, with sub-systems and components commercially available on the market today, even when it is scaled up to an order of magnitude larger than the one at the Johnsonville site. HyPeaker is a technologically viable solution to cover a wide range of energy storage duration needs, from daily peaking operation to seasonal shifting for fossil fueled assets. • The cost advantage of SCCV based Big-Ton H 2 storage vessel made it possible to “oversize” the H 2 storage subsystem to achieve overall system level cost optimization. The benefits are two-fold. First, it allows to significantly reduce the capacity and cost of electrolyzer by spreading H 2 production over a much longer period of time when the fuel cost for electricity production is low. Second, it allows to balance the hydrogen production and usage shift over weeks to months to meet the peak demands. As such, the capital cost of HyPeaker system using the Big-Ton was less than half of the cost of a system with today’s steel tube based H 2 storage system. The HyPeaker has even better cost advantage Li-ion battery based energy storage system. The estimated capital cost of Li-Ion battery system would be at $\$$38M, under the same projected 20-year electricity generation profile of the Johnsonville site. This is over 5 times more expensive than the HyPeaker system. • Since industry scale energy storage systems do not have 100% energy conversion and storage efficiency, energy storage systems using fossil fuel generated electricity would increase the CO 2 emission. This is particularly the case for HyPeaker due to its low round trip efficiency. Therefore, a more sensible solution would be to the excessive or curtailed electricity from CO 2 emission free sources such as solar farms, wind farms or nuclear power plants, to produce hydrogen, and integrate them with the HyPeaker. Electricity from TVA’s nuclear power plants was used for the Johnsonville HyPeaker. • The economic viability of HyPeaker is expected to be further improved when global supply chains are taken into consideration. For the same Johnsonville site specific HyPeaker, the capex would be reduced to ~$\$$3.6M from ~$\$$7.1M, and the added LCOE is reduced to ~$\$$85/MWh. With the bipartisan Infrastructure Investment and Jobs Act, the cost of domestically produced HyPeaker sub-systems would be at the level of today’s global suppliers. Since the peaking units generally operate at peak usage period, thereby demanding higher price, the projected $\$$85/MWh LCOE would be within the realm of financial viability for utility operators.

08 HYDROGEN↗

PathTrace and MPVEASI: A Path Analysis Comparative Validation Study

Developed in 2018, PathTrace is a software package built with the intention of making path analysis simple and intuitive. PathTrace is a top-down pathway analysis software where a user is able to explore vulnerable pathways into a facility. The intention of utilizing a software tool like PathTrace is to characterize an existing physical protection system (PPS) and to upgrade the system to achieve a high level of response interruption, or probability of interruption (P I ) of the adversary. There are four steps for conducting path analysis using PathTrace. The first step is to identify an image to use to build the model and scale the model within PathTrace using a section of known distance (wall or fence perimeter, for example). The scaling process will produce a grid of cells through which the user is able to build a model. The second step is to fill out the grid of cells with four categories of materials: Barriers, Detection Areas, Jumps, and Targets. These materials apply associated delay and detection values to the cells in which they are applied. The third step is to represent the adversary and response forces. The adversaries are represented by their capabilities in interacting with the materials identified in step two, and the response is represented by how quickly they will be able to respond to an adversary attack. Finally, the user is able to take all of the information from the previous three steps and perform a Most Vulnerable Path (MVP) analysis. In this stage, the user is able to visualize vulnerable adversary pathways and reason about how to upgrade these pathways to provide a high level of P I .

97 MATHEMATICS AND COMPUTING↗

Convergence of Emerging Technologies - Spotter Test Results

The SpotterRF CK5 is a low-power draw doppler radar, approximately the size of a book (7” x 9”, see Figure 1). It is intended to provide coverage over short ranges (125 m). The SpotterRF CK5B radar was tested in a two-fence perimeter environment and followed the vendor-recommended configuration (Figure 2), with the exception of rotating the radar 90 degrees about the horizontal axis. The radar is advertised to take approximately 10 minutes to set up.

47 OTHER INSTRUMENTATION↗

Mitigation for Removal of Building 01-103 in the Area 1 Subdock, Nevada National Security Site, Nye County, Nevada

Building 01-103, the Drill Bit Repair Building was originally recorded as SHPO Resource No. B18848 in 2020 during an architectural survey of the Area 1 Subdock (Collins et al. 2022). It was recommended individually eligible for listing in the NRHP under Criteria A and C and contributing to the significance of the Area 1 Subdock Historic District. The SHPO concurred with these determinations in a letter dated April 29, 2022 (Reed 2022). The Drill Bit Repair Building retains all seven aspects of integrity. The location, materials, workmanship, feeling, and association have not changed since its original construction. The design was modified slightly in 1996 with the addition of a removable and non-destructive chain-link fence. Nearby buildings 01-101 and 01-102 were removed (Collins and Menocal 2020) but the other buildings and storage yards remain. Therefore, the integrity of setting has been changed, but not to the degree that the building no longer conveys its significance (see Figures 4 and 5 for comparison). Building 01-103 was constructed in 1985 to coincide with the relocation of the Area 3 Subdock to Area 1. The design for the new Subdock provided a centralized cluster of buildings surrounded by two large storage yards. The buildings included administrative and engineering office space, warehouses, a radiograph building, and Building 01-103 as the drill bit maintenance and repair building, among others. The Drill Bit Repair Building was critical to the success of underground nuclear testing and is eligible under Criterion A for its contribution to broad patterns of history by maintaining specially designed equipment for underground nuclear testing at the NNSS. It is also eligible under Criterion C as it is the only recorded example of a facility built specifically for the maintenance of big-hole drill bits on the NNSS. As it retains both significance and integrity, it remains individually eligible under Criteria A and C. In addition to its individual significance, the Drill Bit Repair Building also contributes to the significance of the Area 1 Subdock Historic District as a representative of a big-hole drilling support facility necessary for underground nuclear testing. The building and the equipment therein were designed specifically for testing at the NNSS, where much of the early technology and methods for big-hole drilling were developed. Its removal will result in not only the demolition of a contributing element but also a change in the physical features of the district’s setting that contribute to its historic significance. The change in setting will diminish the district’s integrity. However, the district still contains numerous examples of other buildings constructed for the purpose of supporting big-hole drilling and remains eligible under Criteria A and C.

54 ENVIRONMENTAL SCIENCES↗

Development of a Two-Dimensional CASTLE Transmission-Line Model for all Levels of Saturn

This report describes a two-dimensional model of Saturn based on the CASTLE transmission line code. Building on previous modeling efforts, 2D circuit models based on the “chain-link fence” geometry are constructed for pre-ReCap Saturn and post-ReCap Saturn. The 2D model results are in better agreement with data from Shot 4550 measurements of load currents and doses then the previous 1D model. Lower doses (9%) predicted by the new model can be compensated by increasing the load A-K gap.

43 PARTICLE ACCELERATORS↗

Principles and Options for Designing Battery Energy Storage Zoning Ordinances

Deployment of battery energy storage (BESS) systems, both standalone and as part of hybrid systems paired with generation, has rapidly increased in the United States in recent years as utilities and communities have deployed storage to improve electric grid reliability and act as a cost-effective alternative to larger grid infrastructure. The modular nature of BESS technologies means systems may be built near other existing land uses, creating the potential for conflicts with neighboring landowners that can be managed and mitigated through zoning and permitting requirements established by local jurisdictions. While many cities and counties have adopted ordinances specific to BESS into their local zoning codes, these ordinances vary significantly in their requirements and level of detail. Meanwhile, many other jurisdictions, including those home to proposed or existing BESS projects, lack any specific language related to BESS in their zoning codes. Local planning and zoning officials have limited capacity and may lack the familiarity with BESS technologies needed to develop ordinances or otherwise make reasonable zoning decisions that balance safety, community impacts, and other goals. The resulting uncertainty at the local zoning level has led developers to withdraw projects in some areas and has spurred moratoria or bans on energy storage projects in others. This report intends to provide practical resources for practitioners interested in reasonable and effective local regulation of battery energy storage. It does not present a model zoning ordinance, but rather is intended to complement model ordinances developed by others by providing additional context and analysis regarding the structure of energy storage zoning ordinances and the decision points for local officials. Zoning ordinances at the city, town, and county level across the U.S. were surveyed alongside two template model ordinances to identify common elements and options for regulating the zoning and siting of BESS. Common elements identified and analyzed include definitions and general requirements, including cutoffs or tiers used to apply regulations to different system sizes and the permitted zones where jurisdictions allow BESS to be sited; visual, noise, and aesthetic requirements, including property line setbacks, fencing and visual screening, noise, and lighting requirements; and safety and planning requirements, such as site plans, decommissioning plans or funds, and requirements for access by emergency services. The report also summarizes some of the more unique regulations, including those that place additional restrictions on BESS at the local level.

25 ENERGY STORAGE↗

Non-Resource Conservation and Recovery Act Corrective Action Unit (CAU) Post-Closure Inspection Report, Nevada National Security Site, Nevada For Calendar Year 2025

This report includes visual inspection results, descriptions of maintenance and repair activities, and recommendations for CY 2025 for use restrictions (URs) at corrective action sites (CASs) located on the Nevada National Security Site and on the Nevada Test and Training Range (NTTR) that are accessed through the NNSS Main Gate. This document is arranged by project activity (i.e., Industrial Sites, Soils, and Defense Threat Reduction Agency [DTRA]); then by corrective action unit (CAU); and then by CAS. Post-closure UR inspections are performed on an annual basis, unless as noted in text. Post-closure UR inspections verify the condition of physical controls required by each UR, which may include the following activities: • Visual verification of the legibility of signs • Visual inspection of fencing, signs, monuments, and/or markers for indications of wear • Visual inspection of soil covers for indications of subsidence, erosion, or unauthorized use Deficiencies in UR requirements that were identified during CY 2024 inspections and not addressed in the CY 2024 report are addressed in this CY 2025 report.

54 ENVIRONMENTAL SCIENCES↗

Temporal partitioning of hatching, maturation, and surface activity by reptiles in Florida longleaf pine-wiregrass sandhills

Temporal partitioning of life history traits among syntopic reptiles can facilitate co-occurrence, but may be influenced by environmental factors and evolutionary history. We used 24 years of continuous capture data in the Florida sandhills to evaluate the timing and duration of hatching, maturation and/or surface activity for ten reptile species, spanning multiple clutch strategies, taxonomic relationships, and habits. We hypothesised: i) species would differ in seasonal timing of hatching and maturation; ii) hatching and maturation periods would be more seasonally-synchronised in fossorial than terrestrial or semi-aquatic reptiles; iii) monthly and annual temperature anomalies would be positively related to hatching, maturation, and surface activity anomalies, and iv) groupings of reptiles by clutch strategy, taxonomic relationship, and habit, would explain more variation in the timing and duration of hatching and maturation than species alone. Seasonal timing of response variables varied widely among species. Hatching peaked for > 1 species during most calendar months. Maturation and surface activity periods ranged from aseasonal to highly-seasonal among species. Hatching began 1.5 months earlier and was more prolonged for terrestrial than fossorial species overall. Hatching peaked in early to mid-summer for terrestrial and fossorial species, and winter for the semi-aquatic Kinosternon subrubrum. Terrestrial and fossorial species did not differ in average timing, duration, or overlap of maturation periods; semi-aquatic Liodytes pygaea matured more consistently across all seasons than other species. Monthly temperature anomalies were negatively correlated with monthly maturation for Plestiodon egregius. Annual temperature and precipitation anomalies were related to annual hatching, maturation, and surface activity trends for several species. Taxonomic relationship, habit, and species explained some variation in hatching and maturation timing and duration. Our results illustrate the influence of environment and evolutionary relationships on the timing of important life history traits. Keywords: Age class, Drift fence, Community, Interspecific, Life history

Zoology↗

Decontamination of Mixed Paper and Plastic Municipal Solid Waste Increases Low and High Temperature Conversion Yields

With the implementation of China’s Green Fence Policy and the following National Sword Policy, there is a need to divert previously accepted waste materials away from the landfill. Mixed plastic and paper wastes that are too contaminated to be economically recycled can be used for conversion into fuels and products. The effect of common contaminants present in waste streams must be determined to make municipal solid waste (MSW) a viable alternative to agricultural feedstocks for conversion. In this study, MSW was sourced from a dual stream materials recovery facility (MRF) in Emmet County, Michigan and characterized via mass balance. The most common contaminants in mixed paper and plastic were quantified and targeted for decontamination when mixed paper was explored for low temperature conversion pathways and plastics for high temperature conversion pathways. Ink, stickies, and plastic contamination were sorted out of the mixed paper stream and did not have an impact on sugar yields during enzymatic hydrolysis (EH). Although no improvement in yield was found, it was noted that copy paper within the mixed paper stream had an elevated pH and higher concentration of fermentation inhibitors, suggesting that intrinsic properties of some paper types may not be ideal for EH and fermentation conversion. Dilute alkaline pretreatment and mechanical refining of mixed paper increased the EH yield of mixed paper, suggesting this previously established process could be used as a decontamination method. “Dirt” and particulates were washed from mixed plastic using either an aqueous detergent or a non-aqueous chemical washing method. Liquid oil yields were increased during microwave assisted fast pyrolysis. All decontamination techniques met the cost target of less than $30/dry ton with plastic decontamination ranging from $18.16 to $24.81/dry ton. Because dilute alkaline pre-treatment and mechanical refining is considered part of the conversion process, the decontamination cost during feedstock preprocessing was considered $0/dry ton.

09 BIOMASS FUELS↗

Epidemiological Investigation of a Mortality Event in a Translocated Gopher Tortoise (Gopherus polyphemus) Population in Northwest Florida

Nokuse Plantation, a 22,055 ha private conservation preserve in northwest Florida, is a recipient site for gopher tortoises translocated from development sites in Florida. Since 2006, Nokuse has received over 5,000 tortoises from multiple development sites. During 2013–2015, 52 tortoises were found sick (n = 14) or dead (n = 38) in multiple soft-release enclosures in which tortoises consistently exhibited clinical signs, with additional sick (n = 5) and dead (n = 5) tortoises presenting similarly during 2016–2017. When found alive, tortoises behaved abnormally (e.g., frequently out of burrows during cold weather, pacing along enclosure fencing), appeared emaciated, were lethargic, and had developed redness under plastron scutes. Similar numbers of male (n = 28) and female (n = 32) tortoises were recovered along with two of unidentified sex, including mainly adults (n = 59) and three subadults. Physical examination, blood analysis, and other diagnostics were indicative of starvation and dehydration. Most sick tortoises provided with supportive care recovered. Necropsy findings generally confirmed starvation, with no evidence of infectious pathogens or contaminants. There were no apparent differences in quality of habitat, plant community, or soil or water among affected and unaffected enclosures. Botanical surveys indicated adequate forage quality and quantity, with no poisonous exotic or native plants detected. No land management practices changed prior to this event. Analysis of epidemiological data and demographic factors from before and during this mortality event identified initial density of tortoises in the enclosures as exerting the strongest influence on detection of tortoise morbidity and mortality. We believe that the stress associated with mixing tortoises from different populations and at higher densities during translocation impacted an individual tortoise’s ability to obtain or absorb adequate nutrients from foraging, ultimately leading to a wasting condition consistent with starvation. Based on our findings, we recommend a maximum of 3 gopher tortoises per ha in soft-release enclosures for translocation, but further research is warranted to investigate the complexity of stress and social pressures associated with translocation.

59 BASIC BIOLOGICAL SCIENCES↗

Computational Fluid Dynamics-Based Modeling of Methane Flows Around Oil and Gas Equipment

Recent studies estimate that emissions from oil and gas production facilities contribute between 20 and 50% of the total methane ( CH 4 ) emitted in the US; therefore, quantifying and reducing these emissions are crucial for achieving climate goals. Methane quantification depends on both measuring methane concentrations and converting them to emissions through a modeling framework. Currently, simple atmospheric dispersion models are primarily used to quantify emissions and concentrations, but these estimates are highly uncertain when quantifying emissions from complex aerodynamic sources, such as oil and gas facilities. This investigation used a CFD modeling approach, which can account for aerodynamic complexity but has hitherto not been used to model methane concentrations downwind of a methane release of a known rate, and compared it against in situ measurements. High-time-resolution (1 Hz) methane concentration and meteorological data were measured during experiments conducted at the METEC on 21 March and 11 July 2024. The METEC site configuration, measured wind data, and controlled emission rates were used as input for the CONVERGE CFD model to model downwind CH 4 concentration. The modeling was carried out between 20 and 70 m, from two different points of release in two separate controlled-release experiments, one from a separator and another from a wellhead. In these experiments, we found that the CFD model could predict the CH 4 concentrations downwind of the release to a good degree. The model was evaluated on multiple metrics to assess its performance in estimating methane concentrations at typical fence line distances (∼30 m). These results help us to understand external flows and the ability of CFD models to predict downwind concentrations in aerodynamically complex environments.

03 NATURAL GAS↗

CosTuuM: Polarized Thermal Dust Emission by Magnetically Oriented Spheroidal Grains

We present the new open-source C++-based Python library CosTuuM that can be used to generate infrared absorption and emission coefficients for arbitrary mixtures of spheroidal dust grains that are (partially) aligned with a magnetic field. We outline the algorithms underlying the software, demonstrate the accuracy of our results using benchmarks from literature, and use our tool to investigate some commonly used approximative recipes. We find that the linear polarization fraction for a partially aligned dust grain mixture can be accurately represented by an appropriate linear combination of perfectly aligned grains and grains that are randomly oriented, but that the commonly used picket fence alignment breaks down for short wavelengths. We also find that for a fixed dust grain size, the absorption coefficients and linear polarization fraction for a realistic mixture of grains with various shapes cannot both be accurately represented by a single representative grain with a fixed shape, but that instead an average over an appropriate shape distribution should be used. Insufficient knowledge of an appropriate shape distribution is the main obstacle in obtaining accurate optical properties. CosTuuM is available as a standalone Python library and can be used to generate optical properties to be used in radiative transfer applications.

79 ASTRONOMY AND ASTROPHYSICS↗

Arctic observations and numerical simulations of surface wind effects on Multi-Angle Snowflake Camera measurements

Abstract. Ground-based measurements of frozen precipitation are heavily influenced by interactions of surface winds with gauge-shield geometry. The Multi-Angle Snowflake Camera (MASC), which photographs hydrometeors in free-fall from three different angles while simultaneously measuring their fall speed, has been used in the field at multiple midlatitude and polar locations both with and without wind shielding. Here, we present an analysis of Arctic field observations – with and without a Belfort double Alter shield – and compare the results to computational fluid dynamics (CFD) simulations of the airflow and corresponding particle trajectories around the unshielded MASC. MASC-measured fall speeds compare well with Ka-band Atmospheric Radiation Measurement (ARM) Zenith Radar (KAZR) mean Doppler velocities only when winds are light (≤5ms-1) and the MASC is shielded. MASC-measured fall speeds that do not match KAZR-measured velocities tend to fall below a threshold value that increases approximately linearly with wind speed but is generally <0.5ms-1. For those events with wind speeds ≤1.5ms-1, hydrometeors fall with an orientation angle mode of 12∘ from the horizontal plane, and large, low-density aggregates are as much as 5 times more likely to be observed. Simulations in the absence of a wind shield show a separation of flow at the upstream side of the instrument, with an upward velocity component just above the aperture, which decreases the mean particle fall speed by 55 % (74 %) for a wind speed of 5 m s−1 (10 m s−1). We conclude that accurate MASC observations of the microphysical, orientation, and fall speed characteristics of snow particles require shielding by a double wind fence and restriction of analysis to events where winds are light (≤5ms-1). Hydrometeors do not generally fall in still air, so adjustments to these properties' distributions within natural turbulence remain to be determined.

54 ENVIRONMENTAL SCIENCES↗

Interference Effects of Fuselage-Stored Missiles on Inlet Duct Model of an Interceptor-Type Aircraft at Mach Numbers 1.5 to 1.9

The effect of missile armament on the performance of an interceptor-type aircraft model has been determined at Mach numbers 1.5, 1.7, and 1.9 and at angles of attack to 19 deg. With this configuration missiles were carried in a bay located on the bottom of the aircraft fuselage and mounted to a rotatable missile door. Rotation of the door then brought the missiles into the external or firing position. The aircraft model was characterized by triangular-shaped normal-shock inlets located at the wing roots. Relatively short and curved subsonic diffusers fed simulated twin side-by-side turbojet engines. Inasmuch as the missile bay extended considerably ahead of the inlet station, rotation of the missile door created considerable disturbance of the flow entering the inlets. In comparison with the internal missile arrangement, the external missile configurations increased the model lift, drag, and pitching moment. While the diffuser-exit flow distortion and static-pressure fluctuations were not greatly affected, diffuser total-pressure recovery was reduced as much as 0.058 at Mach number 1.9 for one missile configuration. The most detrimental effect of missile-door rotation occurred at the transient door positions, or with the door halfwzy between the missiles-in and -out conditions. At this door position the flow into the inlets was highly asymmetrical. Although the performance of both left and right ducts was generally reduced, the inlet duct on the cavity side of the missile door was most severely penalized, becoming unstable recovery losses and increases in flow distortion. The installation of fuselage fences along the missile bay was only partially effective in reducing these losses.

Piercy, T. G.↗

Fan and wing force data from wind tunnel investigation of a 0.38 meter (15 inch) diameter VTOL model lift fan installed in a two dimensional wing

Test data are presented for a 38-cm (15-in.) diameter, 1.28 pressure ratio model VTOL lift fan installed in a two-dimensional wing and tested in a 2.74-by 4.58-meter (9-by 15-ft)V/STOL wind tunnel. Tests were run with and without exit louvers over a wide range of crossflow velocities and wing angle of attack. Tests were also performed with annular-inlet vanes, inlet bell-mouth surface disconuities, and fences to induce fan windmilling. Data are presented on the axial force of the fan assembly and overall wing forces and moments as measured on force balances for various static and crossflow test conditions. Midspan wing surface pressure coefficient data are also given.