Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “feedback control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

The Value of Watching How Materials Grow: A Multimodal Case Study on Halide Perovskites

Material synthesis is one of the most important aspects in humankinds’ endeavor to discover and create new materials for energy applications. One strategy to tailor materials with desired functions in a rational way is by knowing how functions relate to structure, synthetic variables, arrangement of atoms and molecules, and how functions evolve during synthesis. In order to accelerate materials synthesis, discovery, and optimization by 10 times it is the right time now to integrate computational tools, synthesis, and characterization. One particular barrier to realizing this concept is the understanding of when and how phases form in real time during synthesis, which is challenging to asses by existing theoretical frameworks. In addition, transient or metastable phases with positive free energy above the lowest-free energy ground state can be revealed by such real time (in situ) measurements. Metastable materials are ubiquitous in condensed matter and can show superior properties compared to their equilibrium form. This work discusses the value of emerging multimodal in situ characterizations exemplified on hybrid halide perovskites. Finally, the ways in which the implementation of in situ measurements can advance the materials science synthesis field as well as their role to enable close-loop feedback control and autonomous synthesis are discussed.

36 MATERIALS SCIENCE↗

Large-scale additive manufacturing of self-heating molds

Large-scale material extrusion additive manufacturing technology is becoming the new mainstream technology for scaled-up composite mold and die applications. This paradigm shift in composite processing technology is primarily driven by out-of-autoclave tooling applications, in which fiber reinforced composite molds with scaled-up sizes and embedded heating elements are attractive. The present research describes the design, manufacturing, and testing of self-heating composite molds fabricated via a large-scale pellet extrusion 3D printing machine with an integrated wire co-extrusion tool. Polycarbonate (PC) composites reinforced with carbon fiber (PC/CF; 20 wt.%) and glass fiber (PC/GF; 20 wt.%) were used to fabricate mold parts. Joule heating thermal test results showed that uniform temperatures (~100 °C) were achieved for both PC/CF and PC/GF mold surfaces, using a custom-made feedback control power supply and infrared thermography. Mechanical characterizations, including tensile and flexural testing were performed on the wire-embedded and un-wired PC/CF and PC/GF base specimens to investigate the impact of the fiber reinforcement as well as the embedded wires. In the direction of extrusion, the ultimate tensile stress of PC/CF was 105 MPa, and that of PC/GF was 73 MPa, while the neat PC value was 64 MPa. Inner-bead voids and interfacial gaps were observed and characterized via optical and scanning electron microscopy. The embedded wires and inner bead impacted the mechanical properties of the composites. Furthermore, the stiffness of the wire-embedded mold was still satisfactory, proving that the technology can be used to fabricate additively manufactured out-of-oven/autoclave molds.

36 MATERIALS SCIENCE↗

Correlating armature and needle dynamics with voltage waveforms of solenoid-actuated GDI injector

The injector voltage hump that appears near the needle closing has been used for the real-time monitoring and feedback control of fuel injection duration in modern engines. This voltage hump has been thought to result from the abrupt change in electromagnetic induction by the stoppage of needle motion but detailed electromagnetic processes and associated armature and needle dynamics during the needle closing have not been thoroughly investigated in a wide range of injection conditions, which knowledge is crucial for the delicate control of fuel injection based on the voltage hump. Here, the current study analyzes the transient armature and needle dynamics of a solenoid-actuated gasoline direct injection injector using an X-ray phase-contrast imaging technique. Then, the results are correlated with voltage waveforms during the needle closing transient under various injection pressures, injection pulse durations, and dwell times of split injections. The time derivatives of voltage waveforms showed lower and upper peaks in order in the regime of the voltage hump. Inconsistent with conventional understandings, the lower peak timing of the voltage derivative did not match with the timing of needle closing (end of injection) but rather matched with the abrupt descent timing of the armature and needle. The inflection timing and upper peak timing of the voltage derivative matched with the timings of actual needle closing and armature closing respectively. The amplitude of the voltage hump was near linearly dependent on the needle closing speed. The needle closing speed decreased upon the decrease of injection pulse duration and injection pressure which made it difficult to detect the voltage humps in ballistic injection regimes and low injection pressures. In split injection conditions, the voltage hump of the first injection was not detectable if the dwell time was shorter than the needle closing delay, the time from the current cut-off to the actual needle closing.

42 ENGINEERING↗

Parameter dependencies of the experimental nitrogen concentration required for detachment on ASDEX Upgrade and JET

While current tokamak experiments are beginning to use real-time feedback control systems to manage the plasma exhaust, future tokamaks still require validation of theoretical models used to predict the threshold impurity concentration required to sufficiently reduce the power and particle fluxes to the divertor. This work exploits new spectroscopic measurements of the divertor nitrogen concentration, c n , in partially detached N 2 -seeded H-mode plasmas on ASDEX Upgrade (AUG) and JET with the ITER-Like Wall (JET-ILW) to test the parameter dependencies of the power flowing to the outer divertor, P div,outer , and the separatrix electron density, n e.sep . A least-squares regression of the AUG measurements demonstrates that the threshold c n required for detachment scales as $c_n∝P^{1.19±0.32}_{div,outer}n^{-2.77±0.36}_{e,sep}$. This scaling of n e,sep is also consistent with the measurements from JET which, at constant P div,outer , show $c_n∝n^{-2.43±0.27}_{e,sep}$. The dependencies of P div,outer and n e.sep is demonstrated over at least a factor of two change in both parameters and indicates a stronger dependence on n e.sep in comparison to the Lengyel model, which could be due to the assumption in this model that the heat flux channel width is independent of density. This first assessment of detachment scaling with impurity seeding highlights the need for further analysis of the systematic uncertainties of the measurement and more consistent scenarios from more tokamaks to investigate the machine size scaling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and Assessment of a Novel Approach for Ecosystem Warming Experiments in High‐Energy Tidal Wetlands

Abstract Coastal salt marshes have an important role in climate change adaptation and mitigation. Direct and indirect responses to warming are expected to vary along the marsh elevation gradient, making ecosystem responses to warming at this marine‐terrestrial ecotone uncertain. The Marsh Ecosystem Response to Increased Temperatures (MERIT) experiment was established in 2018 on the North Sea coast of Germany. Experimental plots are evenly distributed over three elevational marsh zones (pioneer, low marsh, and high marsh) and include three temperature treatments (ambient, +1.5°C, +3.0°C). MERIT's novel design combines active warming (horizontal surface warming cables and vertical soil warming pins) with passive, partially covered domes. For performance assessment, temperature deltas between ambient and warmed plots were calculated and evaluated at seasonal, daily, and diurnal timescales. We used Linear Mixed Models with Residual Maximum Likelihood for evaluating warming treatment effects and constraining environmental factors. MERIT was effective at ecosystem warming in this high‐energy environment both above‐ and belowground. Mixed models show that warming treatment dominates temperature differences belowground and at the soil surface, along with factors such as wind speed, flooding duration, and solar radiation. Aboveground warming was lower than belowground warming, but the dome design minimized issues seen in other open‐top chamber experiments. The combination of passive aboveground warming with feedback‐controlled active surface and belowground heating provides a setup for understanding warming effects on tidal ecosystems without altering the natural impacts of wind, radiation, and tidal inundations at high‐energy coastlines. Our design creates opportunities to expand future warming experiments to remote locations and technically challenging environments.

Environmental Sciences & Ecology↗

Direct observation of tRNA-chaperoned folding of a dynamic mRNA ensemble

T-box riboswitches are multi-domain noncoding RNAs that surveil individual amino acid availabilities in most Gram-positive bacteria. T-boxes directly bind specific tRNAs, query their aminoacylation status to detect starvation, and feedback control the transcription or translation of downstream amino-acid metabolic genes. Most T-boxes rapidly recruit their cognate tRNA ligands through an intricate three-way stem I-stem II-tRNA interaction, whose establishment is not understood. Using single-molecule FRET, SAXS, and time-resolved fluorescence, we find that the free T-box RNA assumes a broad distribution of open, semi-open, and closed conformations that only slowly interconvert. tRNA directly binds all three conformers with distinct kinetics, triggers nearly instantaneous collapses of the open conformations, and returns the T-box RNA to their pre-binding conformations upon dissociation. This scissors-like dynamic behavior is enabled by a hinge-like pseudoknot domain which poises the T-box for rapid tRNA-induced domain closure. This study reveals tRNA-chaperoned folding of flexible, multi-domain mRNAs through a Venus flytrap-like mechanism.

59 BASIC BIOLOGICAL SCIENCES↗

Exploring electron-beam induced modifications of materials with machine-learning assisted high temporal resolution electron microscopy

Directed atomic fabrication using an aberration-corrected scanning transmission electron microscope (STEM) opens new pathways for atomic engineering of functional materials. In this approach, the electron beam is used to actively alter the atomic structure through electron beam induced irradiation processes. One of the impediments that has limited widespread use thus far has been the ability to understand the fundamental mechanisms of atomic transformation pathways at high spatiotemporal resolution. Here, we develop a workflow for obtaining and analyzing high-speed spiral scan STEM data, up to 100 fps, to track the atomic fabrication process during nanopore milling in monolayer MoS 2 . An automated feedback-controlled electron beam positioning system combined with deep convolution neural network (DCNN) was used to decipher fast but low signal-to-noise datasets and classify time-resolved atom positions and nature of their evolving atomic defect configurations. Through this automated decoding, the initial atomic disordering and reordering processes leading to nanopore formation was able to be studied across various timescales. Using these experimental workflows a greater degree of speed and information can be extracted from small datasets without compromising spatial resolution. This approach can be adapted to other 2D materials systems to gain further insights into the defect formation necessary to inform future automated fabrication techniques utilizing the STEM electron beam.

36 MATERIALS SCIENCE↗

Design study of a combined interferometer and polarimeter for a high-field, compact tokamak

This article is the first design study of a combined interferometer and polarimeter on a compact, high-field, high-density, net-energy tokamak. Recent advances in superconducting technology have made possible designs for compact, high magnetic field fusion power plants, such as ARC [Sorbom et al., Fusion Eng. Des. 100, 378 (2015)], and experiments, such as SPARC [Greenwald et al., PSFC Report No. RR-18-2 (2018)]. These new designs create both challenges and opportunities for plasma diagnostics. The diagnostic proposed in this work, called InterPol, takes advantage of unique opportunities provided by high magnetic field and density to measure both line-averaged density and poloidal magnetic field with a single set of CO 2 and quantum cascade lasers. These measurements will be used for fast density feedback control, constraint of density and safety factor profiles, and density fluctuation measurements. Synthetic diagnostic testing using a model machine geometry, called MQ1 (Mission Q ≥ 1), and profiles simulated with Tokamak Simulation Code indicate that InterPol will be able to measure steady state density and poloidal magnetic field, as well as fluctuations caused by toroidal Alfven eigenmodes and other phenomena on a high-field compact tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advances in physics understanding of high poloidal beta regime toward steady-state operation of CFETR

Experimental and modeling investigations of the high βp scenarios on the DIII-D and EAST tokamaks show advantages in high energy confinement, avoidance of n = 1 MHD, and core-edge integration with reduced heat flux, making this scenario an attractive option for CFETR steady-state operation. Experiments show that plasmas with high confinement and high density can be achieved with neutral beam injection on DIII-D (β p ~ 2.2, β N ~ 3.5, f BS ~ 50%, f Gw ~ 1.0, H 98y2 ~ 1.5) and pure RF power on EAST (β P ~ 2.0, β N ~ 1.6, f BS ~ 50%, f Gw ~ 0.8, H 98y2 > 1.3). By tailoring the current density profile, a q-profile with local (off-axis) negative shear is achieved that yields improved confinement and MHD stability. Transport analysis and simulation suggest that the combination of high density gradient and high Shafranov shift allows turbulence stabilization and higher confinement. Using on-axis ECH injection, tungsten accumulation is avoided on EAST, and this is reproduced in modeling. Reduced heat flux (by >40%) and maintenance of high core confinement is achieved with active feedback control of the radiated divertor, an important result for long pulse operation in tokamaks. In conclusion, the improved physics understanding and validated modeling tools are used to design a 1GW steady-state scenario for CFETR.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First application of a digital mirror Langmuir probe for real-time plasma diagnosis

We report for the first time, a digital Mirror Langmuir Probe (MLP) has successfully sampled plasma temperature, ion saturation current, and floating potential together on a single probe tip in real time in a radio-frequency driven helicon linear plasma device. This is accomplished by feedback control of the bias sweep to ensure a good fit to I–V characteristics with a high frequency, high power digital amplifier, and field-programmable gate array controller. Measurements taken by the MLP were validated by a low speed I–V characteristic manually collected during static plasma conditions. Plasma fluctuations, induced by varying the axial magnetic field($\widetilde{f}$ = 10 Hz), were also successfully monitored with the MLP. Further refinement of the digital MLP pushes it toward a turn-key system that minimizes the time to deployment and lessens the learning curve, positioning the digital MLP as a capable diagnostic for the study of low radio-frequency plasma physics. These demonstrations bolster confidence in fielding such digital MLP diagnostics in magnetic confinement experiments with high spatial and adequate temporal resolution, such as edge plasma, scrape-off layer, and divertor probes.

47 OTHER INSTRUMENTATION↗

Millimeter-wave electromagnetic monitoring for liquid metal droplet-on-demand printing

As new printing approaches emerge, in situ diagnostics to monitor the print quality in real-time become essential for long-term monitoring and feedback control. In this article, we present a millimeter-wave electromagnetic monitoring approach for liquid metal droplet-on-demand printing to support the high-speed and real-time evaluation of droplet ejection. An open-ended rectangular waveguide is placed perpendicular to a jetted droplet stream and operated at a continuous-wave frequency of 40 GHz. Liquid metal droplets with diameters as low as 1.2 mm are characterized, and droplet jetting events on the order of 500 μm are detected at ejection rates up to 80 Hz. The measured results demonstrate that trends at the macro-level (large-scale print variation and anomalies at the nozzle tip) as well as micro-level (droplet size, position, and dynamics) can be detected using this technique.

42 ENGINEERING↗

High resolution atomic force microscopy with an active piezoelectric microcantilever

Active microcantilevers with on-chip sensing and actuation provide significant advantages in tapping mode Atomic Force Microscopy (AFM). Collocated transduction allows for effective manipulation of cantilever dynamics through feedback control, enabling higher scan rates. However, the adjacency of the sensing and actuation electrodes is known to result in a high level of feedthrough, leading to a low imaging resolution. Readout circuit noise further deteriorates the imaging precision. Here, we investigate the noise sources that affect AFM microcantilevers with collocated aluminum nitride (AlN) actuator–sensor pairs. We reported these cantilevers in earlier work and demonstrated that they display a very low level of feedthrough between the actuation and sensing electrodes. We present a high signal-to-noise ratio (SNR) sensing method that enables us to demonstrate high-resolution AFM on a calibration grating with nm-step silicon carbide (SiC) terraces. In conclusion, measuring the Lorentzian response of the cantilever’s Brownian motion with the on-chip active sensor at resonance enables us to calibrate the dynamic stiffness at the first fundamental resonance mode, without utilizing an optical sensor.

47 OTHER INSTRUMENTATION↗

Preface to special topic: The High Repetition Rate Frontier in High-Energy-Density Physics

High-repetition-rate (HRR) experiments can collect large datasets with high temporal, spatial, and/or parametric resolution or large numbers of repeat measurements for statistics. HRR experiments also enable new experimental designs, including active feedback control loops and novel diagnostics, that can improve the reproducibility as well as the quantity of measurements. Together, these attributes make HRR experiments ideal for performing high-quality repeatable science. Until recently, these techniques have not been applied to high-energy-density–physics (HEDP) experiments, which are typically restricted to repetition rates of a few per day. However, recent advancements in lasers, pulsed-power drivers, target fabrication, and diagnostics are starting to change this fact, opening an exciting new frontier of HRR HEDP experiments. A mini-conference on this subject at the 2021 meeting of the American Physical Society Division of Plasma Physics brought together members of this growing community. As a result, the “High Repetition Rate Frontier in High-Energy-Density Physics” special topic in Physics of Plasmas highlights current progress in this exciting area.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implementing microwave impedance microscopy in a dilution refrigerator

We report the implementation of a dilution refrigerator-based scanning microwave impedance microscope with a base temperature of ∼100 mK. The vibration noise of our apparatus with tuning-fork feedback control is as low as 1 nm. Using this setup, we have demonstrated the imaging of quantum anomalous Hall states in magnetically (Cr and V) doped (Bi, Sb)2Te3 thin films grown on mica substrates. Both the conductive edge modes and topological phase transitions near the coercive fields of Cr- and V-doped layers are visualized in the field-dependent results. Our study establishes the experimental platform for investigating nanoscale quantum phenomena at ultralow temperatures.

Instruments & Instrumentation↗

Low latency optical-based mode tracking with machine learning deployed on FPGAs on a tokamak

Active feedback control in magnetic confinement fusion devices is desirable to mitigate plasma instabilities and enable robust operation. Optical high-speed cameras provide a powerful, non-invasive diagnostic and can be suitable for these applications. Here, in this study, we process high-speed camera data, at rates exceeding 100 kfps, on in situ field-programmable gate array (FPGA) hardware to track magnetohydrodynamic (MHD) mode evolution and generate control signals in real time. Our system utilizes a convolutional neural network (CNN) model, which predicts the n = 1 MHD mode amplitude and phase using camera images with better accuracy than other tested non-deep-learning-based methods. By implementing this model directly within the standard FPGA readout hardware of the high-speed camera diagnostic, our mode tracking system achieves a total trigger-to-output latency of 17.6 μs and a throughput of up to 120 kfps. This study at the High Beta Tokamak-Extended Pulse (HBT-EP) experiment demonstrates an FPGA-based high-speed camera data acquisition and processing system, enabling application in real-time machine-learning-based tokamak diagnostic and control as well as potential applications in other scientific domains.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cross-correlation image analysis for real-time single particle tracking

Accurately measuring the translations of objects between images is essential in many fields, including biology, medicine, chemistry, and physics. One important application is tracking one or more particles by measuring their apparent displacements in a series of images. Popular methods, such as the center of mass, often require idealized scenarios to reach the shot noise limit of particle tracking and, therefore, are not generally applicable to multiple image types. More general methods, such as maximum likelihood estimation, reliably approach the shot noise limit, but are too computationally intense for use in real-time applications. These limitations are significant, as real-time, shot-noise-limited particle tracking is of paramount importance for feedback control systems. To fill this gap, we introduce a new cross-correlation-based algorithm that approaches shot-noise-limited displacement detection and a graphics processing unit-based implementation for real-time image analysis of a single particle.

Instruments & Instrumentation↗

A magnetic diagnostic suite for the Pegasus-III experiment

Pegasus-III is an ultralow aspect ratio spherical tokamak providing a dedicated US experiment for comparative solenoid-free startup studies. A new magnetic diagnostic suite for equilibrium and low frequency (<200 kHz) magnetohydrodynamic mode analysis has been installed. These new diagnostics address the significant challenges of measuring magnetic field in a high noise environment with the majority constrained to fit in an 8 mm diagnostic gap on the high field side. Electrostatic switching noise generated by the 16 independent current feedback-controlled power supplies produces dV cm /dt ~ 1 kV/μs and volt level common mode noise on the magnetics. Immunity to this switching noise is accomplished through differential signal runs and signal processing, along with end-to-end electromagnetic interference shielding. The magnetic measurements are simultaneously digitized at 1 MHz and conditioned by precision 8 pole Butterworth filters with a corner frequency of 200 kHz to prevent aliasing down to the 16-bit level over the full passband. Ex-vessel calibrations of the B p coils were completed with a typical uncertainty of <0.5%. Stray toroidal field pickup from coil misalignment or positioning errors is corrected using a physics-based model. Comparisons of the corrected measurements to modeling agree to within 1.3% on average. This is within the 1.5% measurement uncertainty that a sensitivity analysis determined is needed for accurate fast boundary and equilibrium reconstruction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and evaluation of an open-source, conformable skin-cooling system for body magnetic resonance guided focused ultrasound treatments

Magnetic resonance guided focused ultrasound (MRgFUS) treatment of tumors uses inter-sonication delays to allow heat to dissipate from the skin and other near-field tissues. Despite inter-sonication delays, treatment of tumors close to the skin risks skin burns. This work has designed and evaluated an open-source, conformable, skin-cooling system for body MRgFUS treatments to reduce skin burns and enable ablation closer to the skin. A MR-compatible skin cooling system is described that features a conformable skin-cooling pad assembly with feedback control allowing continuous flow and pressure maintenance during the procedure. System performance was evaluated with hydrophone, phantom and in vivo porcine studies. Sonications were performed 10 and 5 mm from the skin surface under both control and forced convective skin-cooling conditions. 3D MR temperature imaging was acquired in real time and the accumulated thermal dose volume was measured. Gross analysis of the skin post-sonication was further performed. Device conformability was demonstrated at several body locations. Hydrophone studies demonstrated no beam aberration, but a 5–12% reduction of the peak pressure due to the presence of the skin-cooling pad assembly in the acoustic near field. Phantom evaluation demonstrated there is no MR temperature imaging precision reduction or any other artifacts present due to the coolant flow during MRgFUS sonication. The porcine studies demonstrated skin burns were reduced in size or eliminated when compared to the control condition. An open-source design of an MRgFUS active skin cooling system demonstrates device conformability with a reduction of skin burns while ablating superficial tissues.

60 APPLIED LIFE SCIENCES↗