Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault injection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Grid-Forming Inverters for Stability Improvements in Bulk Power Systems with High Inverter-Based Resources Penetration

The grid-forming inverter (GFM) has been considered recently as a means to enhance grid stability in areas with Inverter-based Resources (IBRs) concentration. This paper assesses the potential improvements the GFM can bring to Bulk-power Systems (BPS) through two distinct studies. The first study was conducted on West Texas in ERCOT with presence of more than 35GW of IBRs, the Grid-Following (GFL) batteries were replaced with GFM batteries. The results demonstrate that the GFM significantly improved the voltage profile and active power injection during and after a fault. The second study focused on a local area within ERCOT grid. In this case, a battery operating as GFL within the local study area was replaced with a GFM battery. The findings clearly illustrate that GFM can strengthen the area and allow a higher IBRs power generation and a higher power export from the local study area.

Quedan, Amro↗

Understanding Power Systems Protection in the Clean Energy Future

Wind and solar power and battery energy storage are often referred to as inverter-based resources (IBRs), which means they rely on power electronics (inverters) to generate grid-compatible electricity. This is unlike the fossil, nuclear, and hydroelectric plants that use spinning synchronous generators that have provided nearly all U.S. electricity until recently. Synchronous generators can inherently provide several services used to maintain a safe and stable grid and as they are replaced with IBRs it becomes important to understand how these services can be provided. One of these services is fault current, or the ability to inject large amounts of current during a short circuit. This current can easily be detected with low-cost equipment such as circuit breakers. IBRs do not inherently produce large amounts of fault current, and this may eventually require finding alternative sources of fault current or new system protection schemes. This document describes several alternative approaches to maintaining fault current protection and provide a safe, reliable power grid.

14 SOLAR ENERGY↗

Fault Slip and Fluid Flow: Seismic Source Analysis to Assess Role of Multiple Slip Patches in Fault Permeability

The relationship between fault reactivation, microearthquakes (MEQs), and permeability evolution during fluid injection plays a critical role in energy harvesting and waste disposal. Recent studies have demonstrated the possibility of predicting fault permeability using cumulative seismic moments of MEQs quantitatively. To understand the underlying physical processes, we conduct fault reactivation experiments using Utah FORGE granitoid and analyze acoustic emission (AE) signals generated during stepwise increases in fluid injection pressure. Frequency analysis of thousands of calibrated AE signals reveals that fault reactivation produces multiple AE source patches with millimeter-scale radii—smaller than the sample fault radius. The cumulative area of the reactivated patches covers the fault multiple times over (∼10x–50x area) for each pressure step. These findings provide mechanistic insight that measured permeability enhancement is not driven by a single large slip event, but by the sequential and interacting activation of multiple slip patches that create a continuous flow pathway.

Nurshal, M. E. M. [Pennsylvania State University, ↗

An ontology-based fault generation and fault propagation analysis approach for safety-critical computer systems at the design stage

Abstract Fault propagation analysis is a process used to determine the consequences of faults residing in a computer system. A typical computer system consists of diverse components (e.g., electronic and software components), thus, the faults contained in these components tend to possess diverse characteristics. How to describe and model such diverse faults, and further determine fault propagation through different components are challenging problems to be addressed in the fault propagation analysis. This paper proposes an ontology-based approach, which is an integrated method allowing for the generation, injection, and propagation through inference of diverse faults at an early stage of the design of a computer system. The results generated by the proposed framework can verify system robustness and identify safety and reliability risks with limited design level information. In this paper, we propose an ontological framework and its application to analyze an example safety-critical computer system. The analysis result shows that the proposed framework is capable of inferring fault propagation paths through software and hardware components and is effective in predicting the impact of faults.

97 MATHEMATICS AND COMPUTING↗

MIL-M-38510/470 test vectors: Fault detection efficiency measurement via hardware fault simulation

The stuck fault detection efficiency of the test vectors developed for the MIL-M-38510/470 NASA was measured using a hardware stuck fault simulator for the 1802 microprocessor. Thirty-nine stuck faults were not detected out of a total of 874 injected into the combinatorial and sequential parts of the microprocessor. Since undetected faults can create catastrophic errors in equipment designed for high reliability applications, it is recommended that the MIL-M-38510/470 NASA be enhanced with additional test vectors so as to achieve 100% stuck fault detection efficiency.

Timoc, C. C.↗

Assessing Seismic Risk for CO2 Geologic Storage: Comparative Analysis of the Delaware Basin and Basin and Range Province Projects

ABSTRACT: Effective management of induced seismicity is critical for safe and sustainable CO2 storage. This study evaluates fault slippage risks in the Delaware Basin (Texas) and Basin and Range Province (Utah), integrating geological, operational, and geomechanical parameters to assess fault stability and seismic hazard mitigation. In the Delaware Basin, two sites were analyzed under an injection rate of 20,000 bbl/day over 25 years. One site showed low fault slip risk, while the other exhibited higher reactivation potential due to proximity to critically stressed faults. Sensitivity analysis revealed that increased pore pressure significantly heightened slip potential, highlighting the necessity of precise pressure control and real-time monitoring. In the Basin and Range Province, fault stability was evaluated at Neck of the Desert, Escalante Desert, Parowan, and Beaver sites under injection rates of 8,750 bbl/day per site over 30 years. Minimal fault slip risk was observed at Neck of the Desert and Escalante Desert sites, whereas Parowan and Beaver sites exhibited elevated slip potential due to semi-critically stressed faults sensitive to modest pore pressure increases. The findings demonstrate that fault slippage analysis, combined with sensitivity analysis of pore pressure and friction coefficients, is essential for understanding seismic risks. Continuous monitoring, adaptive injection management, and rigorous geomechanical analysis are key strategies for minimizing induced seismicity in CO2 sequestration projects.

58 GEOSCIENCES↗

Direct current momentary circuit interrupter

A momentary circuit interrupter in series connection with a mechanical switch to provide protection against short circuit faults in a DC power circuit. The momentary circuit interrupter injects a transient voltage pulse via a pulse transformer to reduce a DC fault current to near zero in a DC circuit branch, thus allowing the mechanical switch to disconnect the faulty branch under a near zero-current condition. The power electronic circuit on the primary side of the transformer controls the discharge of a plurality of pre-charged capacitors to generate the transient voltage pulse during the fault interruption process, but otherwise does not incur any power loss during normal operation. The secondary winding of the pulse transformer conducts the main DC current, and is highly conductive to minimize the conduction power loss. The invention provides ultrafast response to a short circuit fault (even faster than solid-state circuit breakers and much faster than hybrid circuit breakers), significantly reduced overcurrent stress in the power system, and/or ultralow conduction power losses.

Shen, Zheng John↗

Induced seismicity potential based on probabilistic geomechanics for the San Juan Basin CarbonSAFE project

Although geologic carbon sequestration projects have yet to induce — or may never induce — a damaging earthquake, experiences from other deep injection industries such as hydraulic fracturing, enhanced geothermal systems, and saltwater disposal suggest that effective quantitative seismic risk assessment is necessary for deep saline carbon capture and sequestration (CCS) projects. One such imminent CCS project is the San Juan Basin CarbonSAFE Phase III program. We use Monte Carlo probabilistic geomechanical analyses combined with observations of the geologic and operational parameters of the San Juan Basin site and suggest that this project is of low-induced seismic risk. The primary analysis is split into four sections. First, we assess the literature for faults and past seismicity, and at least five faulting scenarios are directly relevant. Second, we develop and calibrate an integrated earth model for the project site. Third, we perform Monte Carlo simulations that consider reasonable uncertainties of the geomechanical parameters. Of five tested faulting scenarios, only one presents high Coulomb failure functions, but fourth, we determine the risk to be low based on the combined lack of historical seismicity, the geologic framework of the faulting scenario, and the presence of saltwater injection at the same depth as the proposed supercritical carbon dioxide injection. The most sensitive parameters in the geomechanical calculations are the fault dip and the coefficient of friction. The least sensitive are the fault strike and the orientation of the maximum horizontal principal stress.

58 GEOSCIENCES↗

Identification of Faults Susceptible to Induced Seismicity Final Report

The primary objective of this project (referred to as the State of Stress project or SoS project) was to predict the presence of faults susceptible to movement in the presence of fluid injection as a consequence of vertical pressure migration from the storage unit to the crystalline basement. These faults included those difficult to resolve with traditional interpretations of surface seismic: faults with no or minimal offset, faults in the crystalline basement where no seismic reflectors are present, subseismic faults (due to size), and faults undetected (e.g., due to unfavorable orientation with surface seismic survey).

25 ENERGY STORAGE↗

Induced microseismicity and tremor signatures illuminate different slip behaviours in a natural shale fault reactivated by a fluid pressure stimulation (Mont Terri)

SUMMARY Fault slip induced by fluid perturbation in shale formations may only lead to a sparse seismicity. However, fault slip may strongly impact the integrity of shale formations that serve as caprocks for geological reservoirs holding buoyant fluids such as CO2, natural gas or hydrogen. A better understanding of the fluid reactivation processes of fault and the seismic triggering process is therefore critical for reservoir monitoring and fault stability. Here we analyse the seismic responses of a shale fault exposed to fluid pressurization during an in situ field-scale injection experiment at ∼340 m depth in the Mont Terri underground research laboratory (Switzerland). Two main types of seismic signals are observed as the fault was activated and started to slowly slip. After an aseismic phase, we observed tremor signatures and an increase in noise amplitude, which were directly associated with the slowly propagating fault slip in response to fluid injection. These signatures were later followed by micro-earthquakes that seem to occur further away from the fluid-pressurized area. We interpret these micro-earthquakes to be triggered by stress perturbations from the main slip growth. These two classes of seismic responses therefore highlight two different processes. Tremors seem to be a more direct observation for the fluid-induced slip propagation than micro-earthquakes. Even hidden in the noise, they precede earthquake failures, thus providing a useful tool for monitoring fluid leakage activated by slow deformation on low permeable shale faults, with applications for sealing integrity of caprocks.

De Barros, Louis (ORCID:0000000255419162)↗

Behavior of Tidally Triggered Earthquakes Depends on Fluid Conditions

Seismicity at The Geysers geothermal field and in Oklahoma is heavily influenced by industrial activities related to energy production, though the mechanism in which earthquakes are induced or triggered is different. At The Geysers, much of the seismicity is linked to thermoelastic stresses caused by injecting cold water into hot rocks, whereas in Oklahoma, the seismicity is linked to a reduction of confining stress on faults due to increasing pore pressure resulting from wastewater injections. Here, in this study, we show that these contrasting conditions are also evident in tidally triggered earthquakes. At The Geysers, earthquakes preferentially occur during maximum extensional stress, which does not occur at the same time as maximum shear stress on optimally oriented faults in the regional stress field. In Oklahoma, earthquakes preferentially occur during maximum shear stress on optimally oriented faults rather than maximum extensional stress. The magnitude of tidal extensional stress is naturally much greater than tidal shear stress. However, in a fluid-saturated environment, pore pressure responds to changes in volume, which can counteract or reduce the effect of the applied stress. The difference in behavior at these two sites is indicative of the level of coupling between applied stress and pore pressure, corresponding to unsaturated conditions at The Geysers and high pore pressure in Oklahoma.

58 GEOSCIENCES↗

Application of Model-based Prognostics to a Pneumatic Valves Testbed

Pneumatic-actuated valves play an important role in many applications, including cryogenic propellant loading for space operations. Model-based prognostics emphasizes the importance of a model that describes the nominal and faulty behavior of a system, and how faulty behavior progresses in time, causing the end of useful life of the system. We describe the construction of a testbed consisting of a pneumatic valve that allows the injection of faulty behavior and controllable fault progression. The valve opens discretely, and is controlled through a solenoid valve. Controllable leaks of pneumatic gas in the testbed are introduced through proportional valves, allowing the testing and validation of prognostics algorithms for pneumatic valves. A new valve prognostics approach is developed that estimates fault progression and predicts remaining life based only on valve timing measurements. Simulation experiments demonstrate and validate the approach.

prediction↗

DeFault: DEep‐Learning‐Based FAULT Delineation Using the IBDP Passive Seismic Data at the Decatur CO2 Storage Site

Abstract The carbon capture, utilization, and storage (CCUS) framework is an essential component in reducing greenhouse gas emissions, with its success hinging on the comprehensive knowledge of subsurface geology and geomechanics. Passive seismic event relocation and fault detection offer vital insights into subsurface structures and the ability to monitor fluid migration pathways. Accurate identification and localization of seismic events, however, face significant challenges, including the necessity for high‐quality seismic data and advanced computational methods. To address these challenges, we introduce a novel deep learning method, , specifically designed for passive seismic source relocation and fault delineating for passive seismic monitoring projects. By leveraging data domain‐adaptation, allows us to train a neural network with labeled synthetic data and apply it directly to field data. Using , the passive seismic sources are automatically clustered based on their recording time and spatial locations, and subsequently, faults and fractures are delineated accordingly. We demonstrate the efficacy of on a field case study involving injection related microseismic data from Decatur, Illinois area. Our approach accurately and efficiently relocated passive seismic events, identified faults and could aid in potential damage induced by seismicity. Our results highlight the potential of as a valuable tool for passive seismic monitoring, emphasizing its role in ensuring CCUS project safety. This research bolsters the understanding of subsurface characterization in CCUS, illustrating machine learning’s capacity to refine these methods. Ultimately, our work has significant implications for CCUS technology deployment, an essential strategy in combating climate change. Plain Language Summary In our quest to tackle climate change, we use a strategy known as carbon capture, utilization, and storage (CCUS) to keep greenhouse gases out of the atmosphere. This strategy relies heavily on our ability to understand what's happening deep under the earth's surface. To make sure we store super critical safely, we need to accurately map out the geological structure, especially faults, but this is tough without high‐quality data and complex computer programs. We've developed a new tool called “DeFault,” which uses advanced machine learning to improve how we find and map these underground features. “DeFault” is smart enough to learn from numerically simulated data and then apply what it’s learned to real‐world situations. It groups together seismic activity—tiny tremors and shifts in the earth—based on when and where they happen, which helps us spot where there might be cracks or faults. We tested “DeFault” in Illinois, where CO 2 is injected underground, and it successfully pinpointed where these tremors occurred and mapped out the faults, helping to prevent accidents accurately in the future. Our study shows that “DeFault” will be a powerful ally in making CCUS safer and more effective, especially for the Illinois Basin Decatur Project. Key Points Faults and fractures introduced by carbon storage can be monitored by passive seismicity DeFault algorithm enables an automatic process for accurate and efficient passive seismic event locating and clustering

58 GEOSCIENCES↗

Searching for Grid-Forming Technologies That Do Not Impact Protection Systems: A promising technology

The design of legacy-line protection elements has been guided by the behavior of synchronous machines during faults. Because of the significant field-winding inductance and rotating mass, the magnitude, angular frequency, and phase angle of the back-electromotive force (EMF) voltage waveforms of synchronous machines remain practically constant for several hundreds of milliseconds after a fault occurs. Furthermore this has facilitated the engineering of the memory-polarization technique in mho distance elements, which has been effective for machine-dominant power grids. However, this assumption is no longer held for inverter-based resources (IBRs) because of the lack of field winding and moment of inertia in power electronics devices. Notably, the negative-sequence directional overcurrent protection and the quadrilateral distance elements have been impacted by early IBRs with grid-following (GFL) controls because they did not inject negative-sequence currents during asymmetrical faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Potential Seismicity Along Basement Faults Induced by Geological Carbon Sequestration

Large-scale CO 2 sequestration into geological formations has been suggested to reduce CO 2 emissions from industrial activities. However, much like enhanced geothermal stimulation and wastewater injection, CO 2 sequestration has a potential to induce earthquake along weak faults, which can be considered a negative impact on safety and public opinion. This research shows the physical mechanisms of potential seismic hazards along basement faults driven by CO 2 sequestration under variation in geological and operational constraints. Specifically we compare the poroelastic behaviors between multiphase flow and single-phase flow cases, highlighting specific needs of evaluating induced seismicity associated with CO 2 sequestration. In contrast to single-phase injection scenario, slower migration of the CO 2 plume than pressure pulse may delay accumulation of pressure and stress along basement faults that may not be mitigated immediately by shut-in of injection. The impact of multiphase flow system, therefore, needs to be considered for proper monitoring and mitigation strategies.

58 GEOSCIENCES↗

Impacts of Different Operation Conditions and Geological Formation Characteristics on CO2 Sequestration in Citronelle Dome, Alabama

Major concerns of carbon dioxide (CO2) sequestration in subsurface formations are knowledge of the well injectivity and gas storage capacity of the formation, the CO2 pressure and saturation plume extensions during and after injection, and the risks associated with CO2 leakage and fault reactivation. Saline reservoirs are considered as one of the target formations for CO2 sequestration through structural, residual, dissolution, and mineral trapping mechanisms. The boundary condition of the saline reservoir dictates the pressure and saturation plume extension of the injected supercritical CO2 that could expand over large distances. This can lead to sources of risk, e.g., leakage and/or fault reactivation due to presence of wells, thief zones, and geological discontinuities. Therefore, there is a critical need to develop a model that describes how risk-related performance metrics (i.e., the CO2 saturation plume size, the pressure differential plume area, and the pressure differential at specific locations) vary as a function of the size of injection, time following injection, injection operations, and geologic environment. In this study, a systematic reservoir modeling studies of anthropogenic CO2 sequestration in Citronelle dome, Alabama, was performed where all relevant scenarios and conditions to address the questions of the saturation and pressure plume size in the area of review (AoR) and post-injection site care (PISC) are considered. The objective for this study was firstly to systematically simulate CO2 sequestration, i.e., saturation dynamics, and pressure behavior over a range of operational and geological conditions and to derive conclusions about the factors influencing saturation and pressure plume size, post-injection behavior, and the risk associated with them, by developing third-generation reduced order models (ROMs) for reservoir behavior. Finally, to assess the uncertainty associated with our studies, Latin Hypercube Sampling (LHS) together with an experimental design technique, i.e., Plackett–Burman design, was used. Application of Pareto charts and respond surfaces enabled us to determine the most important parameters impacting saturation and pressure plume sizes and to quantify the auto- and cross-correlation among different parameters in both history-matched and upscaled models.

58 GEOSCIENCES↗

Enabling Grid-Forming Control with Fault Ride-Through in Unbalanced Distribution Networks

Distribution networks are often unbalanced, causing oscillatory responses in inverter control designed for balanced conditions. Here, to address this problem, this paper proposes a novel time-domain transformation appropriate for inverter control and enables the decomposition of three-phase unbalanced signals into constant positive and negative components. Relations useful for calculating unbalanced active and reactive power are derived from first principle, providing insight into vector products of unbalanced three-phase signals. Furthermore, a grid-forming control effective under unbalanced conditions is developed, which delivers superior performance while meeting UNIFI1 specifications for grid-forming control under unbalanced conditions. specifications applicable to category 4 inverter-based resource, like setting and regulating frequency/voltage, providing voltage support, sharing active power, injecting negative sequence current, and riding through faults. A current limiter is proposed for safe fault ride-through and integrates with the grid-forming control featuring frequency/voltage droop controllers and current and voltage control loops. The transformation of interconnected inverters is formulated and stability of the proposed control analyzed to support robust parameter selections. The effectiveness of the proposed transformation and grid-forming control is demonstrated through analytical results and real-time simulation of a IEEE 123 distribution network on the Real-Time Digital Simulator. Comparison with existing methods shows that the proposed strategy satisfies the UNIFI specifications with a much better performance.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

DOE 10658 Project Sensitivity-Driven Wide Area Protection (SWAP) Coordination Tools for IBRs

Utilities have seen a rapid increase in solar, wind, and battery energy storage systems that interconnect to their electric system through inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well-known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protects the inverter’s sensitive power electronics devices from damage from conditions such as overcurrent. This results in a low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufacturers and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of focusing on one issue, this report looks broadly at all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspectives from different utility SMEs via questionnaire, the report summarizes the gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION↗