Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Spread Spectrum Time Domain Reflectometry (SSTDR) Digital Twin Simulation of Photovoltaic Systems for Fault Detection and Location

Utilizing spread spectrum time domain reflectometry (SSTDR) to detect, locate, and characterize faults in photovoltaic (PV) systems is examined in this paper. We present a method to obtain the model parameters that are needed to produce digital twin SSTDR responses for PV systems. The digital twin SSTDR responses could be used to predict faults within the PV systems. Here, the model parameters are the reflection and transmission coefficients at each impedance discontinuity in the PV system along with the propagation coefficients across each PV cable segment. We obtain model parameter by applying inverse modeling techniques to experimental SSTDR data associated with PV systems. Our model parameters can be used in any digital twin simulation method for modeling reflectometry in frequency-dependent and complex loads. For validation, we used the model parameters in a graph network simulation engine and adapted it to be used for SSTDR digital twin simulations in PV systems. We produced simulations for 0 to 10 PV modules connected in series. We also simulated SSTDR responses for open circuit disconnections in a PV setup containing 10 PV modules in series. Results show that all but one simulated disconnect locations match experimental disconnection locations of the same setup with an error of less than 5%.

14 SOLAR ENERGY↗

Soft-Fault Detection Technologies Developed for Electrical Power Systems

The NASA Glenn Research Center, partner universities, and defense contractors are working to develop intelligent power management and distribution (PMAD) technologies for future spacecraft and launch vehicles. The goals are to provide higher performance (efficiency, transient response, and stability), higher fault tolerance, and higher reliability through the application of digital control and communication technologies. It is also expected that these technologies will eventually reduce the design, development, manufacturing, and integration costs for large, electrical power systems for space vehicles. The main focus of this research has been to incorporate digital control, communications, and intelligent algorithms into power electronic devices such as direct-current to direct-current (dc-dc) converters and protective switchgear. These technologies, in turn, will enable revolutionary changes in the way electrical power systems are designed, developed, configured, and integrated in aerospace vehicles and satellites. Initial successes in integrating modern, digital controllers have proven that transient response performance can be improved using advanced nonlinear control algorithms. One technology being developed includes the detection of "soft faults," those not typically covered by current systems in use today. Soft faults include arcing faults, corona discharge faults, and undetected leakage currents. Using digital control and advanced signal analysis algorithms, we have shown that it is possible to reliably detect arcing faults in high-voltage dc power distribution systems (see the preceding photograph). Another research effort has shown that low-level leakage faults and cable degradation can be detected by analyzing power system parameters over time. This additional fault detection capability will result in higher reliability for long-lived power systems such as reusable launch vehicles and space exploration missions.

Button, Robert M.↗

A New High-Impedance-Fault Detection Method to Prevent Power-Line-Induced Wildfires

High Impedance Faults (HIFs) occur when energized power lines come into contact with high impedance ground surfaces, such as tree branches and grassland. HIFs have the potential to cause arcing, leading to vegetation ignition and the initiation of wildfires. The challenge in detecting HIFs comes from the high impedance of the partially conductive materials in contact with the power lines. They create a fault current of low magnitude and traditional protective devices struggle to detect such faults. This paper proposes a novel HIF detection algorithm based upon the analyzed arcing signatures associated with HIFs. The algorithm is evaluated using the Australian Public Bushfire Safety Program (PBSP) dataset. For comparative analysis, a state-of-the-art commercial HIF detection product is also evaluated using the same dataset. The proposed algorithm demonstrates higher detection accuracy over the commercial products with fewer false flags and undetected faults.

grasslands↗

Machine learning for photovoltaic single axis tracker fault detection and classification

More than 81% of the annual capacity of utility-scale photovoltaic (PV) power plants in the U.S. use single-axis trackers (SATs) due to SATs delivering 4% in capacity factor on average over fixed-array systems. However, SATs are subject to faults, such as software misconfigurations and mechanical failures, resulting in suboptimal tracking. If left undetected, the overall power yield of the PV power plant is reduced significantly. Minimizing downtime and ensuring efficient operation of SATs requires robust detection and diagnosis mechanisms for SAT faults. We present a machine learning framework for implementing real-time SAT fault detection and classification. Our implementation of the proposed framework reliably identifies measurements taken from a test PV system undergoing emulated SAT faults relative to state-of-the-art algorithms and produces nearly zero false positives on our testing days. Code and data are available at https://pvpmc.sandia.gov/tools.

Fault classification↗

Use of Traveling Wave Signatures in Medium-Voltage Distribution Systems for Fault Detection and Location

Protection systems are a critical feature for the proper operation of a power grid. Protection systems should be able to quickly detect, identify, locate, and isolate the faults within a time frame that prevents damage to grid components and reduces customer outages. As more inverter-based photovoltaics (PV) are integrated into the grid, phasor domain based protection schemes become more inaccurate due to low levels of fault current from inverters or respond too slowly to accurately identify fault conditions. This points to the need to identify and develop novel protection approaches for distribution systems with high penetration of inverter based PV. The main objective of the project is to develop new time domain-based protection schemes to enable more accurate and faster detection, identification and location of faults in distribution systems and/or microgrids with high penetration of inverter-based PV. Our approach aims to exploit the traveling waves that are generated during a fault or other disturbances in the grid.

14 SOLAR ENERGY↗

Composite Bending Box Section Modal Vibration Fault Detection

One of the primary concerns with Composite construction in critical structures such as wings and stabilizers is that hidden faults and cracks can develop operationally. In the real world, catastrophic sudden failure can result from these undetected faults in composite structures. Vibration data incorporating a broad frequency modal approach, could detect significant changes prior to failure. The purpose of this report is to investigate the usefulness of frequency mode testing before and after bending and torsion loading on a composite bending Box Test section. This test article is representative of construction techniques being developed for the recent NASA Blended Wing Body Low Speed Vehicle Project. The Box section represents the construction technique on the proposed blended wing aircraft. Modal testing using an impact hammer provides an frequency fingerprint before and after bending and torsional loading. If a significant structural discontinuity develops, the vibration response is expected to change. The limitations of the data will be evaluated for future use as a non-destructive in-situ method of assessing hidden damage in similarly constructed composite wing assemblies. Modal vibration fault detection sensitivity to band-width, location and axis will be investigated. Do the sensor accelerometers need to be near the fault and or in the same axis? The response data used in this report was recorded at 17 locations using tri-axial accelerometers. The modal tests were conducted following 5 independent loading conditions before load to failure and 2 following load to failure over a period of 6 weeks. Redundant data was used to minimize effects from uncontrolled variables which could lead to incorrect interpretations. It will be shown that vibrational modes detected failure at many locations when skin de-bonding failures occurred near the center section. Important considerations are the axis selected and frequency range.

Werlink, Rudy↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids

Increasing penetration levels of inverter based distributed energy resources (DERs) impact the legacy distribution system protection. Inverter based DERs provide approximately 1.2-2 pu fault current. In systems with high penetration of inverter based DERs, it is difficult for over-current based protection schemes to differentiate between normal loading conditions and a fault. Directional, distance, and adaptive forms of protection schemes are also affected by low fault currents. This paper analyzes fault generated traveling wave (TW) based high-frequency signatures in the distribution system. In order to simulate such signatures, frequency-dependent distributed parameter line modeling approach is used in this research work to represent distribution lines and underground cables. Modified IEEE 13-bus medium voltage test system is modeled in electromagnetic transient simulation tool and multiple transient scenarios are simulated in this test system. The results are analyzed to understand the high-frequency signatures that can be used to detect and locate faults under high penetration of DERs.

41 EE - Solar Energy Technologies Office (EE-4S)↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids

Increasing penetration levels of inverter based distributed energy resources (DERs) impact the legacy distribution system protection. Inverter based DERs provide approximately 1.2-2 pu fault current. In systems with high penetration of inverter based DERs, it is difficult for over-current based protection schemes to differentiate between normal loading conditions and a fault. Directional, distance, and adaptive forms of protection schemes are also affected by low fault currents. This paper analyzes fault generated traveling wave (TW) based high-frequency signatures in the distribution system. In order to simulate such signatures, frequency-dependent distributed parameter line modeling approach is used in this research work to represent distribution lines and underground cables. Modified IEEE 13-bus medium voltage test system is modeled in electromagnetic transient simulation tool and multiple transient scenarios are simulated in this test system. The results are analyzed to understand the high-frequency signatures that can be used to detect and locate faults under high penetration of DERs.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Provider and User Perspectives on Automated Fault Detection and Diagnostic Products for Packaged Rooftop Units

The goal of this project was to understand, based on the primary reporting of AFDD providers and building owners, 1) the features currently available for RTU AFDD in the market today, 2) how RTU AFDD is used by building owners and managers, 3) how well RTU AFDD meets their needs, and 4) what barriers stand in the way of its broad industry adoption. To achieve this goal, 13 AFDD providers were asked about their products and seven building owners were questioned about their practical experience related to the automated detection, diagnosis, and communication of RTU faults.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fault Analysis of Space Station DC Power Systems-Using Neural Network Adaptive Wavelets to Detect Faults

This paper describes the application of neural network adaptive wavelets for fault diagnosis of space station power system. The method combines wavelet transform with neural network by incorporating daughter wavelets into weights. Therefore, the wavelet transform and neural network training procedure become one stage, which avoids the complex computation of wavelet parameters and makes the procedure more straightforward. The simulation results show that the proposed method is very efficient for the identification of fault locations.

Momoh, James A.↗

Application of Convolutional and Feedforward Neural Networks for Fault Detection in Particle Accelerator Power Systems

High voltage converter modulators (HVCM) provide power to the accelerating cavities of the spallation neutron source (SNS) facility. HVCM experience catastrophic failures, which increase the downtime of the SNS and reduce beam time. The faults may occur due to different reasons including failures of the resonant capacitor, core saturation due to the magnetic flux, insulated-gate bipolar transistor (IGBT) failures, and others. We recently have setup a HVCM test stand to develop and test machine learning models for anomaly detection and fault prognostics. In this work, we propose binary classifiers and autoencoder architectures based on convolutional (CNN) and feedforward neural networks (FNN) to facilitate distinguishing normal from faulty waveforms coming from the HVCM during operation. The results indicate that the CNN binary classifier is the best model among the four showing very stable performance in the training and testing sets with impressive metrics of precision and recall reaching up to 99\% with a very small uncertainty. The FNN classifier shows the least performance with a large uncertainty in its metrics. The performances of the two autoencoders based on CNN and FNN were in between, showing very good performance nonetheless.

Radaideh, Majdi↗

Two Trees: Migrating Fault Trees to Decision Trees for Real Time Fault Detection on International Space Station

We started from ISS fault trees example to migrate to decision trees, presented a method to convert fault trees to decision trees. The method shows that the visualizations of root cause of fault are easier and the tree manipulating becomes more programmatic via available decision tree programs. The visualization of decision trees for the diagnostic shows a format of straight forward and easy understands. For ISS real time fault diagnostic, the status of the systems could be shown by mining the signals through the trees and see where it stops at. The other advantage to use decision trees is that the trees can learn the fault patterns and predict the future fault from the historic data. The learning is not only on the static data sets but also can be online, through accumulating the real time data sets, the decision trees can gain and store faults patterns in the trees and recognize them when they come.

Lee, Charles↗

Holistic Measurement Driven Resilience: Combining Operational Fault and Failure Measurements and Fault Injection for Quantifying Fault Detection, Propagation and Impact. Final report

For HPC systems to date, application resilience to faults and failures has been accomplished by the brute- force method of checkpoint/restart, which allows an application to make forward progress in the face of system and application faults, errors, and failures independent of root cause or end result. It has remained the primary resilience mechanism because we lack a way to identify faults and anticipate consequences early enough to take meaningful mitigating action. However, checkpoint/restart implementations put a tremendous burden on system resources and on the applications themselves and is becoming less feasible at scale. Because we have not yet operated at scales at which checkpoint/restart fails to provide forward progress, despite increasing costs, vendors have had little motivation to provide the instrumentation necessary for early identification of faults and failures. However, as we move from petascale to exascale, component mean time to failure (MTTF) will render the existing techniques ineffectual and/or too expensive. Furthermore, fault recovery mechanisms such as failover and/or error correction introduce performance inconsistency. Instrumentation allowing early indication of problems and tools to enable use of such information by systems, operating systems, and applications offer an alternative, more scalable and less costly solution. In the HMDR project, we built on our experience and expertise developed and accumulated over years of research on design, monitoring, measurement, and assessment of resilient computing systems. Analysis of field data on the current and past generations of extreme-scale systems revealed several challenges that, if not addressed in increasingly larger and more complex systems, may hinder the effectiveness of future exascale computing systems. Specifically, i) file systems and interconnects in current-generation large-scale systems already operate at the margins of resiliency, including consistent performance, and may not scale to larger deployments; ii) automated, software-based failover mechanisms are frequently inadequate and can introduce wider failures, such that failures during recovery may lead to system/application failures, including system-wide outages; and iii) silent data corruption represents a critical fault mode and will require efficient detection mechanisms if next-generation applications are to take full advantage of exascale hardware. To address the above challenges, we assembled a team of world-renowned experts in resilient extreme- scale computing from the University of Illinois (Electrical and Computer Engineering, Computer Science, and NCSA), SNL, LANL, NERSC, and Cray. Our team includes representatives from centers that house many of the largest HPC resources in the world, both today and over the coming years. The team has a unique track record of research in i) system and application failure characterization based on the analysis of field data, ii) data-driven design of fault/error detection mechanisms, and iii) experimental characterization of system/application resiliency. The team includes system owners/operators who provide continuous data collection and access and ensure installation of appropriate analysis tools.

97 MATHEMATICS AND COMPUTING↗