Fire-induced failure mode testing for dc-powered control circuits.
No abstract prepared.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract prepared.
No abstract prepared.
Not Available
Fundamental aspects and attendant failure mechanisms for high-temperature composites are summarized. These include in situ matrix behavior, load transfer, limits on matrix ductility to survive a given number of cyclic loadings, fundamental parameters which govern thermal stresses, vibration stresses and impact resistance, as well as their attendant failure mechanisms and failure sequences. The resulting guidelines are presented in terms of simple equations which are suitable for the preliminary assessment of the merits of a particular high-temperature composite in a specific application.
As the design of Micro-Electro-Mechanical System (MEMS) devices matures and their application extends to critical areas, the issues of reliability and long-term survivability become increasingly important. This paper reviews some general approaches to addressing the reliability and qualification of MEMS devices for space applications.
In 2022, NASA’s Artemis program returned the agency to lunar space, propelled by the Orion European Service Module (ESM). Through rigorous ground test campaigns for Artemis I and II and the collection and transmission of operational data during the Artemis I flight, the Safety and Mission Assurance (S&MA) team created and maintained a robust database of component nonconformances. This study analyzes in-flight and ground processing findings on the Artemis ESM propulsion subsystem to track reliability and safety metrics, as well as comparing the data to that of previous human spaceflight programs, Apollo and Space Shuttle. In drawing a comparison to the Artemis I flight, recommendations can be made for the Artemis II crewed mission to ensure best practices for flight safety, including redundancy and failure tolerance in the system. The results reinforce a need for robust safety standards and caution against the complacency of a single successful test flight.
In 2022, NASA’s Artemis program returned the agency to lunar space, propelled by the Orion European Service Module (ESM). Through rigorous ground test campaigns for Artemis I and II and the collection and transmission of operational data during the Artemis I flight, the Safety and Mission Assurance (S&MA) team created and maintained a robust database of component nonconformances. This study analyzes in-flight and ground processing findings on the Artemis ESM propulsion subsystem to track reliability and safety metrics, as well as comparing the data to that of previous human spaceflight programs, Apollo and Space Shuttle. In drawing a comparison to the Artemis I flight, recommendations can be made for the Artemis II crewed mission to ensure best practices for flight safety, including redundancy and failure tolerance in the system. The results reinforce a need for robust safety standards and caution against the complacency of a single successful test flight.
A review was made of failures and irregularities experienced on nickel cadmium batteries for 31 spacecraft. Only rarely did batteries fail completely. In many cases, poorly performing batteries were compensated for by a reduction in loads or by continuing to operate in spite of out-of-voltage conditions. Low discharge voltage was the most common problem observed in flight spacecraft (42%). Spacecraft batteries are often designed to protect against cell shorts, but cell shorts accounted for only 16% of the failures. Other causes of problems were high charge voltage (16%), battery problems caused by other elements of the spacecraft (10%), and open circuit failures (6%). Problems of miscellaneous or unknown causes occurred in 10% of the cases.
Fundamental aspects of and attendant failure mechanisms for high temperature composites are summarized. These include: (1) in-situ matrix behavior; (2) load transfer; (3) limits on matrix ductility to survive a given number of cyclic loadings; (4) fundamental parameters which govern thermal stresses; (5) vibration stresses; and (6) impact resistance. The resulting guidelines are presented in terms of simple equations which are suitable for the preliminary assessment of the merits of a particular high temperature composite in a specific application.
Ways in which failure can occur in reduced-order, orbit determination filter, error covariance calculations are discussed. In the context of this article, reduced-order filters denote nonoptimal filters which include fixed levels of uncertainty in some parameters of the measurement models or in the spacecraft dynamical model which are not explicitly estimated in the filter equations. Failure is defined as an increase in the orbit determination covariance with the addition of data or as an unreasonable growth in the covariance with time, i.e., nonasymptotic behavior of the covariance. Some simple, known cases of failure are discussed along with their traditional remedies. In addition, more modern remedies are discussed which are currently under development at the Jet Propulsion Laboratory. The article first describes the known problems of reduced-order filters when they are employed for orbit determination, and their traditional remedies. Then, having defined these, the relevancy and desirability of the more modern remedies are made apparent.
Power-on failure has been the prevalent failure mechanism for solid tantalum capacitors in decoupling applications. A surge step stress test (SSST) has been previously applied to identify the critical stress level of a capacitor batch to give some predictability to the power-on failure mechanism [1]. But SSST can also be viewed as an electrically destructive test under a time-varying stress (voltage). It consists of rapidly charging the capacitor with incremental voltage increases, through a low resistance in series, until the capacitor under test is electrically shorted. When the reliability of capacitors is evaluated, a highly accelerated life test (HALT) is usually adopted since it is a time-efficient method of determining the failure mechanism; however, a destructive test under a time-varying stress such as SSST is even more time efficient. It usually takes days or weeks to complete a HALT test, but it only takes minutes for a time-varying stress test to produce failures. The advantage of incorporating a specific time-varying stress profile into a statistical model is significant in providing an alternative life test method for quickly revealing the failure mechanism in capacitors. In this paper, a time-varying stress that mimics a typical SSST has been incorporated into the Weibull model to characterize the failure mechanism in different types of capacitors. The SSST circuit and transient conditions for correctly surge testing capacitors are discussed. Finally, the SSST was applied for testing Ta capacitors, polymer aluminum capacitors (PA capacitors), and multi-layer ceramic (MLC) capacitors with both precious metal electrodes (PME) and base metal electrodes (BME). The test results are found to be directly associated with the dielectric layer breakdown in Ta and PA capacitors and are independent of the capacitor values, the way the capacitors were built, and the capacitors manufacturers. The test results also show that MLC capacitors exhibit surge breakdown voltages much higher than the rated voltage and that the breakdown field is inversely proportional to the dielectric layer thickness. The SSST data can also be used to comparatively evaluate the voltage robustness of capacitors for decoupling applications.
Systems which are placed on test at time zero, function for a period and die at some random time were studied. Failure may be due to one of several causes or modes. The parameters of the life distribution may depend upon the levels of various stress variables the item is subject to. Maximum likelihood estimation methods are discussed. Specific methods are reported for the smallest extreme-value distributions of life. Monte-Carlo results indicate the methods to be promising. Under appropriate conditions, the location parameters are nearly unbiased, the scale parameter is slight biased, and the asymptotic covariances are rapidly approached.
A combined theoretical-experimental investigation of failure in notched, graphite-epoxy, angle-ply laminates subjected to far-field compression loading indicates that failure generally initiates on the hole boundary and propagates along a line parallel to the fiber orientation of the laminate. The strength of notched laminates with specimen width-to-hole diameter ratios of 5 and 10 are compared to the strength of unnotched laminates. The experimental results are complemented by a three-dimensional finite element stress analysis that includes interlaminar stresses around holes in (+/- theta)s laminates. The finite element predictions indicate that failure is initiated by shear stresses at the hole boundary.
A combined experimental and analytical investigation of an adhesively bonded composite joint was conducted to characterize both the static and fatigue beyond growth mechanism under mode 1 and mixed-mode 1 and 2 loadings. Two bonded systems were studied: graphite/epoxy adherends bonded with EC 3445 and FM-300 adhesives. For each bonded system, two specimen types were tested: a double-cantilever-beam specimen for mode 1 loading and a cracked-lapshear specimen for mixed-mode 1 and 2 loading. In all specimens tested, failure occurred in the form of debond growth. Debonding always occurred in a cohesive manner with EC 3445 adhesive. The FM-300 adhesive debonded in a cohesive manner under mixed-mode 1 and 2 loading, but in a cohesive, adhesive, or combined cohesive and adhesive manner under mode 1 loading. Total strain-energy release rate appeared to be the driving parameter for debond growth under static and fatigue loadings.
A combined experimental and analytical investigation of an adhesively bonded composite joint was conducted to characterize both the static and fatigue beyond growth mechanism under mode 1 and mixed-mode 1 and 2 loadings. Two bonded systems were studied: graphite/epoxy adherends bonded with EC 3445 and FM-300 adhesives. For each bonded system, two specimen types were tested: a double-cantilever-beam specimen for mode 1 loading and a cracked-lapshear specimen for mixed-mode 1 and 2 loading. In all specimens tested, failure occurred in the form of debond growth. Debonding always occurred in a cohesive manner with EC 3445 adhesive. The FM-300 adhesive debonded in a cohesive manner under mixed-mode 1 and 2 loading, but in a cohesive, adhesive, or combined cohesive and adhesive manner under mode 1 loading. Total strain-energy release rate appeared to be the driving parameter for debond growth under static and fatigue loadings.
The application of general design approaches for preventing failures due to repeated load cycles is briefly discussed. Program objective, mission requirements, and structural design criteria are summarized. Discrete structural elements and associated sections were selected for detailed strength, fatigue, and fracture mechanics investigations.
Objectives include: a) Define major Command and Service Module (CSM) design considerations; b) List Command Module (CM) RCS failures and lessons learned; and c) List Service Module (SM) RCS failures and lessons learned.
Tectonic faults fail in a continuum of modes from slow earthquakes to elastodynamic rupture. Precursory variations in elastic wavespeed and amplitude, interpreted as indicators of imminent failure, have been observed in limited natural settings and lab experiments where they are thought to arise from contact rejuvenation and microcracking within and around the fault zone. However, the physical mechanisms and connections to fault creep are poorly understood. Here we vary loading stiffness during frictional shear to generate a range of slip modes and measure fault zone properties using transmitted elastic waves. We find that elastic wave amplitudes show clear changes before fault failure. The temporal onset of amplitude reduction scales with lab earthquake magnitude and the magnitude of this reduction varies with fault slip. Our data provide clear evidence of precursors to lab earthquakes and suggest that continuous seismic monitoring could be useful for assessing fault state and seismic hazard potential.