Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Considerations for Fire Service Response to Residential Battery Energy Storage System Incidents

Renewable energy sources (e.g., rooftop photovoltaics, wind turbines) are capable of addressing our grid-level energy challenges by reducing environmental impacts, increasing resiliency, and increasing the supply of input energy. However, renewable energy sources alone are not a complete solution. The generation of power from major renewable energy sources fluctuates with the weather, creating significant challenges in matching electrical power generation to electrical power consumption. The value of renewable power generation sources is multiplied when paired with battery energy storage systems (ESS), which can store excess power generated from renewable energy sources when it is not consumed and deliver that power later when demand exceeds base power generation. Residential ESS units are frequently installed to support renewable energy initiatives by storing energy from intermittent sources such as photovoltaic panels. Residential ESS units also offer an alternative to gas-powered generators or other backup power means. Lithium-ion batteries are the most common residential ESS technology due to their affordability and energy density. Though lithium-ion systems come with benefits, there is also a risk of thermal runaway within this technology which can result in flammable gas release, fire, and explosion. As the installations of these products increase, the frequency of response to fire incidents involving these products will increase. In response to this new and evolving hazard, UL Solutions (ULS) and UL Fire Safety Research Institute (FSRI) have partnered with the International Association of Fire Fighters (IAFF) to conduct a series of large-scale tests sponsored by the US Department of Energy to characterize the challenges for fire fighters responding to fires involving residential energy storage systems. The project focuses on developing size-up and tactical considerations to support the fire service in navigating the evolving modern fireground.

25 ENERGY STORAGE↗

Thermal Stability of Silica for Application in Thermal Energy Storage: Preprint

Free from siting constraints, thermal energy storage (TES) shows promise as an economical alternative to traditional pumped-storage hydropower (PSH) and compressed air energy storage (CAES). As potential thermal energy storage media, many solid particles demonstrate stability over wide temperature ranges which allows for increased sensible energy storage density and is essential in achieving low-cost storage. Silica sand, in the form of a-quartz, is one such candidate. This work presents a brief review of relevant silica thermophysical properties and further investigates the thermal stability of silica particles as a candidate TES media by subjecting them to two different thermal campaigns: (1) a 500-hour thermal treatment at 1200°C under varied atmospheres; and (2) cycling 25, 50, and 100 times between 300°C and 1200°C. For both campaigns, particle stability is examined by means of pre- and post-treatment Mie scattering. An additional XRD analysis is conducted for the 500-hour treatment in air. Results indicate limited changes in both particle distribution and crystallographic structure which is promising for the application as solid particle media for thermal energy storage.

27 ARPA - Advanced Research Projects Agency-Energy↗

Fabrication, Modeling, and Testing of a Prototype for Particle Thermal Energy Storage Containment

Increasing penetration of variable renewable energy resources requires the deployment of energy storage at a range of durations. Long-duration energy storage (LDES) technologies will fulfill the need to firm variable renewable energy resource output throughout the year. Conventional electrochemical batteries (e.g., lithium-ion) are uneconomical in this role due to high energy capacity costs. Thermal energy storage (TES) is one promising technology for LDES applications because of its siting flexibility and ease of scaling. Particle-based TES systems use low-cost solid particles that have higher temperature limits than the molten salts used in traditional concentrated solar power systems. A key component in particle-based TES systems is the containment silo for the high-temperature (> 1100 degrees C) particles. This study combined experimental testing and computational modeling methods to design and characterize the performance of a particle containment silo for LDES applications. A containment silo prototype was built at a laboratory scale and used to validate a congruent transient finite element analysis (FEA) model. The validation compared the actual and predicted temperature profile through the prototype over six days as the particles cooled from their initial temperature. The performance of a commercial scale (> 5 GWhth) was then characterized using the validated model. The transient FEA model was subject to several charge-discharge cycles to mimic a possible operating schedule. The commercial-scale model predicted a storage efficiency in excess of 95% after five days of storage with a design storage temperature of 1200 degrees C. Insulation material and concrete temperature limits were considered as well. The validation of the methodology means the FEA model can simulate a range of scenarios for future applications. This work supports the development of a promising LDES technology with implications for grid-scale electrical energy storage, but also for thermal energy storage for industrial process heating applications.

ENERGY STORAGE↗

2020 Energy Storage Pricing Survey

The annual Energy Storage Pricing Survey (ESPS) series is designed to provide a standardized reference system price for various energy storage technologies across a range of different power and energy ratings. This is an essential first step in comparing systems of the different technologies’ usage costs and total cost of ownership. The final system prices are developed based on data from an extensive set of interviews with representatives across the manufacturing and project development value chain, plus available published data. This information is incorporated into a consistent methodology structure that will allow pricing information to be incorporated at whatever level it was obtained, ranging from component to fully installed system. The ESPS system pricing methodology breaks down the cost of an energy storage system into the following component categories: the storage module; the balance of system; the power conversion system; the energy management system; and the engineering, procurement, and construction costs. By evaluating each of the different component costs separately, a more accurate system cost can be developed that provides internal pricing consistency between different project sizes using the same technology, as well as between different technologies that utilize similar components.

25 ENERGY STORAGE↗

Fabrication, Modeling, and Testing of a Prototype Thermal Energy Storage Containment

Increasing penetration of variable renewable energy resources requires the deployment of energy storage at a range of durations. Long-duration energy storage (LDES) technologies will fulfill the need to firm variable renewable energy resource output year round; lithium-ion batteries are uneconomical at these durations. Thermal energy storage (TES) is one promising technology for LDES applications because of its siting flexibility and ease of scaling. Particle-based TES systems use low-cost solid particles that have higher temperature limits than the molten salts used in traditional concentrated solar power systems. A key component in particle-based TES systems is the containment silo for the high-temperature (>1100 degrees C) particles. This study combined experimental testing and computational modeling methods to design and characterize the performance of a particle containment silo for LDES applications. A laboratory-scale silo prototype was built and validated the congruent transient finite element analysis (FEA) model. The performance of a commercial-scale silo was then characterized using the validated model. The commercial-scale model predicted a storage efficiency above 95% after 5 days of storage with a design storage temperature of 1200 degrees C. Insulation material and concrete temperature limits were considered as well. The validation of the methodology means the FEA model can simulate a range of scenarios for future applications. This work supports the development of a promising LDES technology with implications for grid-scale electrical energy storage, but also for thermal energy storage for industrial process heating applications.

clean energy↗

Evaluation of Nominal Energy Storage at Existing Hydropower Reservoirs in the US

Long-term planning and operation of hydropower reservoirs require an understanding of both water and energy storage. As energy storage needs of the evolving grid increase, we must account for the water and energy storage potential of these reservoirs. Given the limitations of current data on existing hydropower, we compile statistics related to storage volume and hydraulic head from publicly available data sets and examine differences in descriptions of US hydropower storage. Assembled characteristics are used to calculate nominal energy storage capacity, a simple measure of potential to generate power from a given volume of water, not factoring in detailed constraints. Inventory-based estimates of energy storage are calculated at 2,075 dams, which helps put the potential for US hydropower to support energy storage in context with similar evaluations in other regions and with other energy storage technologies. The national energy storage capacity ranges between 34.5 and 45.1 TWh depending on the information used, with 52% of energy storage located at the 10 largest reservoirs in the US. Energy storage capacities are also calculated at 236 dams with historical volume and elevation data. Finally, reservoir inflows provide context for the storage volumes and sensitivities to hydrologic variability. Larger reservoirs with greater storage volume to inflow ratios are concentrated in the Western US, but the majority of hydropower reservoirs store less than the annual inflow. We address several infrastructure and water resource informatics challenges and highlight remaining issues, including representing seasonal or shorter variability in water volumes and representing connected hydropower facilities.

13 HYDRO ENERGY↗

Demonstration of Single Axis Combined Attitude Control and Energy Storage Using Two Flywheels

The energy storage and attitude control subsystems of the typical satellite are presently distinct and separate. Energy storage is conventionally provided by batteries, either NiCd or NiH, and active attitude control is accomplished with control moment gyros (CMGs) or reaction wheels. An overall system mass savings can be realized if these two subsystems are combined using multiple flywheels for simultaneous kinetic energy storage and momentum transfer. Several authors have studied the control of the flywheels to accomplish this and have published simulation results showing the feasibility and performance. This paper presents the first experimental results showing combined energy storage and momentum control about a single axis using two flywheels.

Kenny, Barbara H.↗

Multifunctional energy storage composites

Described here is a multifunctional energy storage (MES) composite comprising (a) a stack of energy storage materials and (b) one or more structural facesheets sandwiching the stack of energy storage materials, wherein the stack of battery materials is perforated by (c) one or more reinforcements, and wherein the reinforcements are bonded to the structural facesheets. Also described here is a MES composite comprising (a) a stack of energy storage materials, (b) one or more structural facesheets sandwiching the stack of energy storage materials, and (c) one or more reinforcements perforated by the stack of energy storage materials, wherein the reinforcements are bonded to the structural facesheets.

25 ENERGY STORAGE↗

Exploring the Future Energy Value of Long-Duration Energy Storage

Long-duration energy storage is commonly viewed as a key technology for providing flexibility to the grid and broader energy systems over a multidecadal time frame. However, prior work has typically used present-day grid infrastructures to characterize the relationship between the duration and arbitrage value of storage in electricity markets. This study leverages established National Renewable Energy Laboratory grid planning and operations tools, analysis, and data to execute a price-taker model of an energy storage system for several 8760 h price series representative of current and future contiguous United States grid infrastructures with varying shares of variable renewable energy (VRE). We find that the total value of energy storage typically increases with VRE shares, but any increase in the relative value of longer storage durations over time depends on the region and grid mix. Some regions see incremental value increasing notably, up to 20–40 h in 2050, while others do not. The negative effect of lower roundtrip efficiency on value is also found to be scenario-dependent, with the energy value in higher VRE scenarios being less sensitive to roundtrip efficiency and more supportive of longer storage durations. Long-duration storage value and deployment potential are a function of evolving electricity sector infrastructure, markets, and policy, making it critical to consistently revisit potential long-duration storage contributions to the grid.

14 SOLAR ENERGY↗

Solar applications analysis for energy storage

The role of energy storage as it relates to solar energy systems is considered. Storage technologies to support solar energy applications, the status of storage technologies, requirements and specifications for storage technologies, and the adequacy of the current storage research and development program to meet these requirements are among the factors discussed. Emphasis is placed on identification of where the greatest potential exists for energy storage in support of those solar energy systems which could have a significant impact on the U.S. energy mix.

Blanchard, T.↗

Beyond short-duration energy storage

Long-duration energy storage technologies can be a solution to the intermittency problem of wind and solar power but estimating technology costs remains a challenge. New research identifies cost targets for long-duration storage technologies to make them competitive against different firm low-carbon generation technologies.

25 ENERGY STORAGE↗

Principles and Options for Designing Battery Energy Storage Zoning Ordinances

Deployment of battery energy storage (BESS) systems, both standalone and as part of hybrid systems paired with generation, has rapidly increased in the United States in recent years as utilities and communities have deployed storage to improve electric grid reliability and act as a cost-effective alternative to larger grid infrastructure. The modular nature of BESS technologies means systems may be built near other existing land uses, creating the potential for conflicts with neighboring landowners that can be managed and mitigated through zoning and permitting requirements established by local jurisdictions. While many cities and counties have adopted ordinances specific to BESS into their local zoning codes, these ordinances vary significantly in their requirements and level of detail. Meanwhile, many other jurisdictions, including those home to proposed or existing BESS projects, lack any specific language related to BESS in their zoning codes. Local planning and zoning officials have limited capacity and may lack the familiarity with BESS technologies needed to develop ordinances or otherwise make reasonable zoning decisions that balance safety, community impacts, and other goals. The resulting uncertainty at the local zoning level has led developers to withdraw projects in some areas and has spurred moratoria or bans on energy storage projects in others. This report intends to provide practical resources for practitioners interested in reasonable and effective local regulation of battery energy storage. It does not present a model zoning ordinance, but rather is intended to complement model ordinances developed by others by providing additional context and analysis regarding the structure of energy storage zoning ordinances and the decision points for local officials. Zoning ordinances at the city, town, and county level across the U.S. were surveyed alongside two template model ordinances to identify common elements and options for regulating the zoning and siting of BESS. Common elements identified and analyzed include definitions and general requirements, including cutoffs or tiers used to apply regulations to different system sizes and the permitted zones where jurisdictions allow BESS to be sited; visual, noise, and aesthetic requirements, including property line setbacks, fencing and visual screening, noise, and lighting requirements; and safety and planning requirements, such as site plans, decommissioning plans or funds, and requirements for access by emergency services. The report also summarizes some of the more unique regulations, including those that place additional restrictions on BESS at the local level.

25 ENERGY STORAGE↗

Defining Safe and Efficient Interconnection Policies for Energy Storage and Solar + Storage to Improve Integration and Reduce Costs

Energy storage has a unique and pivotal role to play in the transition to a low-carbon economy because it can help the electric grid accommodate more renewable energy. However, a number of barriers currently impede the process of connecting energy storage systems to the distribution grid. The Toolkit and Guidance for the Interconnection of Energy Storage and Solar-Plus-Storage (the “BATRIES Toolkit”), which is the publication subject to this Final Technical / Scientific Report, provides vetted solutions to eight regulatory and technical barriers to the interconnection of standalone storage and solar-plus-storage systems (referred to as “energy storage”) to the distribution grid. These recommendations are based on over a year of research and analysis by utility and industry experts. The BATRIES Toolkit also includes model language that utilities and utility regulators can use to update state interconnection rules to reduce the costs and time to safely interconnect energy storage and solar-plus-storage systems. The solutions are nationally applicable and can be applied in diverse states and markets across the U.S.

14 SOLAR ENERGY↗

Development of a Test-Bed for Testing and Refining EarthEn’s Supercritical CO 2 Based Energy Storage System

EarthEn’s energy storage concept leverages supercritical carbon dioxide (sCO 2 ) as a working fluid and relies on compact, high-performance components operating at elevated pressures and temperatures. To accelerate component development and reduce technical risk prior to larger-scale demonstrations, Oak Ridge National Laboratory (ORNL) developed a 100 kW-scale sCO 2 test-bed under a Cooperative Research and Development Agreement with EarthEn (CRADA NO. NFE-24-10050). The objective of the work was to design and construct a flexible experimental facility capable of reproducing key thermodynamic state points and heat-transfer conditions relevant to EarthEn’s thermal energy storage (TES) cycle, with particular emphasis on enabling development and evaluation of next-generation heat exchangers and TES concepts. The test-bed consists of a closed-loop sCO 2 circulation system housed within an open-topped enclosure. In its as-installed configuration, dense-phase sCO 2 is recirculated through a printed circuit recuperator, an electrically heated section, a throttling device used to simulate turbine expansion, and a water-cooled printed circuit heat exchanger that rejects heat to the building chilled-water system before returning to the pump. The pump is driven by a variable frequency drive, enabling controlled adjustment of flow and operating point. A comprehensive instrumentation suite was integrated to support both safe operation and high-quality data collection. Installed sensors include Coriolis flow meters for sCO 2 flow rate and density, resistance temperature detectors and thermocouples distributed throughout the loop (including the heated section and key heat exchanger ports), and pressure transducers for absolute and differential pressure measurements. The facility was designed to support high-pressure (19 MPa nominal) and high-temperature (575°C nominal) operation with credited overpressure protection provided by a rupture disk. Nominal operating conditions were selected to support 100 kW-class testing while maintaining flexibility for non-heated and heated shakedown, control development, and future integration of advanced TES test sections. In parallel with facility development, a system-level thermal-hydraulic model was created using Modelica-based tools to support component sizing, anticipate performance over targeted test conditions, and establish a framework for future model calibration against experimental data. At the conclusion of the project performance period, the facility was in final assembly, and the pressure boundary was nearly completed. However, several practical challenges associated with high-pressure/high-temperature systems and specialized component procurement impacted schedule and prevented initial pump-driven operation and full commissioning within the available resources. This report documents the as-built design, operating capabilities, and instrumentation, and it summarizes key lessons learned related to heater fabrication and testing, first-of-a-kind assembly factors, specialty flange supply constraints, and fill pump corrective actions. Finally, it outlines a phased plan for future commissioning and experimental campaigns, including control and instrumentation shakedown, heater characterization, model calibration, and testing at state points representative of EarthEn’s TES cycle.

25 ENERGY STORAGE↗

Particle-based high-temperature thermochemical energy storage reactors

Solar and other renewable energy driven gas-solid thermochemical energy storage (TCES) technology is a promising solution for the next generation energy storage systems due to its high operating temperature, efficient energy conversion, ultra-long storage duration, and potential high energy density. Experimental and theoretical studies suggest that the respective gravimetric and volumetric TCES energy storage densities vary from 200 to 3000 kJ kg –1 and 1–3 GJ m –3 . Solar radiation or heat generated from electric furnaces powered by renewable electricity can be stored in the form of chemical energy through endothermic reactions, while the stored chemical energy can be converted to thermal energy via an exothermic reaction when needed. The design of highly effective reactors requires a deep understanding of materials, thermodynamics, chemical kinetics, and transport phenomena. At time of writing, TCES reactors are yet to be deployed at commercially relevant scales, leaving a substantial gap between development efforts and commercial feasibility. Therefore, this review aims to examine the state-of-the-art design and performance of particle-based TCES reactors with different reactive materials. Fundamentals related to TCES reactive materials, reaction conditions, thermodynamics and kinetics, and transport phenomena are reviewed in detail to provide a comprehensive understanding of the reactor design and operation. Five major types of TCES reactors have been comprehensively reviewed and compared, including fixed, moving, rotary, fluidized, and entrained bed reactors. Most reported prototype reactors in the literature operate at lab scale with thermal inputs below 40 kW, and scaled TCES reactors (e.g., at megawatt level) are yet to be demonstrated. The nominal reactor operating temperatures range from 300 to 1500 °C, depending on the selected chemistry, reactive material, and heat sources. To evaluate their designs, the reactors are assessed in aspects of performance, cost, and durability. Discrepancies in performance indicators of energy storage density, extent of reaction, and various energy efficiencies are highlighted. The scale-up of reactors and power block integration, which hold the key to the successful commercialization of TCES systems, are critically analyzed. Furthermore, advanced materials (both reactive materials and ceramic reactor housing materials), effective particle flow control, advanced modeling tools, and novel system design may bring significant improvement to the energy efficiency, storage density and cost competitiveness of particle-based TCES reactors.

25 ENERGY STORAGE↗

A hierarchical framework for aggregating grid-interactive buildings with thermal and battery energy storage

The behind-the-meter (BTM) thermal and battery energy storage can help improve energy efficiency, reduce energy costs, and enhance energy resilience, particularly in rural areas and for disadvantaged communities. Aggregating numerous BTM energy storage systems can act as a price influencer with a significant source of load shifting and peak demand reduction. An integrated and scalable control mechanism is required to effectively utilize energy storage systems and flexible building loads to maximize the economic benefits, considering various distribution system constraints. Here, this paper presents an innovative hierarchical coordination framework for energy storage and flexible load in buildings, considering various factors such as electricity prices, thermal comfort, and distribution system modeling and constraints. At the upper level, a distribution system operator optimizes the power flow to minimize its power procurement costs from the electricity wholesale market, while at the lower level, aggregators determine the optimal dispatch of battery and thermal energy storage systems in multiple buildings on behalf of end-users to minimize operating costs according to the power prices. These problems are solved using a game-theoretic approach through negotiations between the distribution system operator and aggregators as a bi-level decision model. Simulation case studies have been performed for a test distribution network with a number of building end-users using energy storage systems to quantify the performance of aggregators. The results demonstrate that the proposed strategy can reduce peak load for a reliable electricity distribution network while saving electricity bills for customers.

25 ENERGY STORAGE↗