Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy prices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

U.S. Solar Photovoltaic System and Energy Storage Cost Benchmarks, With Minimum Sustainable Price Analysis: Q1 2022

NREL's bottom-up cost models can be used to assess the minimum sustainable price (MSP) and modeled market price (MMP) of PV and storage systems having various configurations. MSP can be used to estimate future potential cost-reduction opportunities for PV and PV-plus-storage systems, thus helping guide research and development aimed at advancing cost-effective system configurations. MMP can be used to understand the cost of systems under recent market conditions. The MSP data in this annual benchmarking report will be used to inform the formulation of, and track progress toward, the Solar Energy Technologies Office's Government Performance and Reporting Act cost targets.

14 SOLAR ENERGY↗

Investigating the effects of cooperative transmission expansion planning on grid performance during heat waves with varying spatial scales

There is growing recognition of the advantages of interregional transmission capacity to decarbonize electricity grids. A less explored benefit is potential performance improvements during extreme weather events. This study examines the impacts of cooperative transmission expansion planning using an advanced modeling chain to simulate power grid operations of the United States Western Interconnection in 2019 and 2059 under different levels of collaboration between transmission planning regions. Two historical heat waves in 2019 with varying geographical coverage are replayed under future climate change in 2059 to assess the transmission cooperation benefits during grid stress. The results show that cooperative transmission planning yields the best outcomes in terms of reducing wholesale electricity prices and minimizing energy outages both for the whole interconnection and individual transmission planning regions. Compared to individual planning, cooperative planning reduces wholesale electricity prices by 64.3 % and interconnection-wide total costs (transmission investments + grid operations) by 34.6 % in 2059. It also helps decrease greenhouse gas emissions by increasing renewable energy utilization. However, the benefits of cooperation diminish during the widespread heat wave when all regions face extreme electricity demand due to higher space cooling needs. Despite this, cooperative transmission planning remains advantageous, particularly for California Independent System Operator with significant diurnal solar generation capacity. This study suggests that cooperation in transmission planning is crucial for reducing costs and increasing reliability both during normal periods and extreme weather events. It highlights the importance of optimizing the strategic investments to mitigate challenges posed by wider-scale extreme weather events of the future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

Tunisia Air Conditioner Market Assessment

Air conditioners contribute significantly to peak power demand during Tunisia's hot summers. In 2021, the Tunisian Electricity and Gas Company (STEG) recorded a peak demand of 4,472 megawatts in August, estimating that 44% of that demand was due to the operation of air conditioners. The Tunisian government, through its Agence Nationale pour la Maitrise de L'Energie (ANME) and all of its partners, is called on to take advantage of the significant potential for energy efficiency and to achieve the objectives it has set for itself by accelerating the implementation of programs that expand the adoption of efficient appliances, including air conditioners. This report aims to assess the Tunisian market for air conditioners, particularly in terms of energy performance. The report provides an overview of the size and characteristics of the AC market in Tunisia, including product types, origins, and proportion of imports to locally manufactured units; an estimation of the informal market; energy performance; and price.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cybersecurity concerns for the energy sector in the maritime domain

The world has seen a number of high-profile maritime disasters in recent months and years, and has felt the impact of them. At the same time, the world has also seen a number of high-profile cyberattacks. It has felt their impact, as well. And, likely no sector has been more affected by the maritime and cyber incidents than the energy sector, as fuel prices often spike or trough, and access to energy resources can become an instant source of concern, tension, or even conflict. As energy sectors—in all their forms—continue to rely on the maritime domain or even increase that reliance, they must be mindful that traditional maritime threats—like piracy, theft, and weather events—are not the only threats they face today. Maritime cybersecurity concerns are among the most potentially disruptive to energy-sector interests and, yet, are among the least understood and least addressed. This paper identifies nine areas in which the energy sector faces harmful cyber vulnerabilities in the maritime domain, to provide enough insight and examples to allow for action to be taken to reduce the risk of harm from these different vulnerabilities. The paper develops the example of offshore wind energy to model how to assess cyber considerations more fully. Ultimately, it concludes with a series of recommendations that offer policymakers, energy-sector actors, and security and law-enforcement professionals steps to minimize the exposure of the maritime energy sector to harmful cyberattacks.

99 GENERAL AND MISCELLANEOUS↗

IDAES-PSE Software Tools for Optimizing Energy Systems and Market Interactions

Modern power grids coordinate electricity production and consumption via multi-scale wholesale energy markets. Historically, levelized cost metrics were the de facto standard for techno-eco-nomic analyses of energy systems and comparison of technology options. However, these metrics neglect the complexity of energy infrastructure including the time-varying value of electricity. An emerging alternative is multi-period optimization, which considers the locational marginal price of electricity as input data (parameters). In this work, we present a general interface for multi-period optimization with time-varying energy prices to facilitate rapid analysis and comparison of potential energy systems models. The PriceTakerModel class is written in the IDAES-PSE platform and allows users to generate a multi-period, price-taker model instance, as well as automatically generate common operational constraints for their model, such as start-up and shutdown. We show this interface successfully generates multi-period price-taker models, facilitates model discrimination, and aids in analyzing various technologies for deployment in unique energy markets.

Laky, Daniel↗

Agent-Based Simulation of Price-Demand Dynamics in Multi-Service Charging Station

As the adoption of electric vehicles and hydrogen fuel-cell vehicles grows, understanding how dynamic pricing strategies influence charging and refueling behaviors becomes crucial for optimizing local energy markets. This paper proposes a simulation-based analysis of a hydrogen-electricity integrated charging station that serves both types of vehicles. A multi-agent simulation framework is developed to model the interactions between vehicles and the station, incorporating price- and delay-sensitive behaviors in decision-making. The station can dynamically adjust energy prices, while vehicles optimize their charging or refueling choices based on their utility values. A series of sensitivity analyses are conducted to evaluate how electricity pricing, infrastructure capacity, and waiting behavior impact station performance. Results highlight that moderate electricity prices maximize user participation without sacrificing profit, infrastructure should be right-sized to demand to avoid over- or underutilization, and delay-toleration also affects service outcomes, which may reach the maximum service coverage at the threshold of 45 minutes.

Wang, Xudong [University of Tennessee, Knoxville (↗

Let's Get Greedy: The L-Prize Invites Innovators to 'Have It All'

LEDs have arrived. They’re long-lasting, energy-efficient, and priced competitively with the products they’re replacing. Case closed and let’s move on, right? And yet… transformative lighting has the capacity do more, with excellent energy and application efficiency, data-driven functionality, material sustainability, and the ability to make buildings better places to work, live, learn, and heal – for people in all communities. This article on the DOE L-Prize invites competitors to participate in the $12.2 million L-Prize competition. The competition sets ambitious innovation goals for efficacy, quality of light, connectivity, material sustainability, and diversity, equity, and inclusion. LED lighting offers the opportunity to address all of these - to "have it all". The article will be published in the August edition of Lighting Design and Application (LD&A) magazine.

LED Lighting, Efficacy, Lighting Quality, Connecte↗

Applying Non-Energy Impacts from Other Jurisdictions in Cost-Benefit Analyses of Energy Efficiency Programs: Resources for States for Utility Customer-Funded Programs

Avoided energy and capacity costs are the primary yardstick utilities use to determine which energy efficiency programs are cost-effective for their customers. But sometimes "non-energy impacts" — not commonly recognized as directly associated with energy generation, transmission and distribution — represent substantial benefits, such as improving comfort, air quality and public health. Considering whether and how to include non-energy impacts is an important part of cost-benefit analyses for these programs. This report offers practical considerations for deciding which non-energy impacts to include and how to apply values or methods from other jurisdictions. Researchers reviewed studies quantifying non-energy impacts used in 30 states and applied a five-point system to indicate transferability of a value or method from each study for 16 categories of non-energy impacts: Water resource costs and benefits; Other fuels costs and benefits; Avoided environmental compliance costs; Environmental impacts; Productivity; Health and safety; Asset value; Energy and/or capacity price suppression effects; Avoided costs of compliance with Renewable Portfolio Standard requirements; Avoided credit and collection costs; Avoided ancillary services; Comfort; Economic development and job impacts; Public health impacts; Energy security impacts; Increased reliability. The U.S. Department of Energy’s Building Technologies Office supported this work.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DSO+T: Transactive Energy Coordination Framework (DSO+T Study: Volume 3)

This report describes a transactive energy coordination scheme designed to integrate into existing day-ahead and real-time wholesale energy markets. This scheme was evaluated in the Distribution System Operator with Transactive (DSO+T) study to assess the engineering and economic performance of the transactive energy coordination of a large-scale deployment of distributed energy resources (DER). Transactive agents were developed for a range of DERs (heating, ventilation, and air conditioning units, water heaters, batteries, and electric vehicles) that optimize flexibility over a 48-hour horizon and adjust their strategy in response to changes in real-time prices. A transactive energy coordination scheme, executed by a DSO retail market operator, aggregates these DER bids from participating customers and clears them against a DSO supply curve using a double auction market mechanism. The process of constructing the price-quantity DSO supply curve includes distribution-level transportation constraints (for example, substation congestion limits) and forecast locational marginal price of the DSO’s connected transmission node. The resulting day-ahead and real-time quantities are then bid into a competitive wholesale market operated by an independent system operator. This report also details additional capabilities for proper marketplace simulation such as wholesale price, weather, and load forecasting. The report concludes with a discussion of lessons learned and key design features required to ensure successful operation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Price Formation and Grid Operation Impacts from Variable Renewable Energy Resources

Increasing amounts of Variable Renewable Energy Resources (VREs) impact electricity markets and their operation. VREs are intermittent, zero marginal cost resources that tend to displace emissions-intensive generators in electricity dispatch, reducing emissions, but impacting price formation, revenue sufficiency, reliability, and market power mitigation processes of electricity markets. But VREs are not the only factor that affects operational and financial challenges in electricity markets. Declining natural gas prices, changing resource mixes, as well as different electricity market designs and regulatory policies all factor into the challenges both electricity market participants and operators face in today’s electricity markets. With this in-depth examination of electricity markets and related literature review, we aim to inform on key challenges of market design and operation for successful integration of large amounts of zero marginal cost resources. We’ve identified several areas, including VREs impact on price formation, revenue sufficiency, reliability, market power monitoring and mitigation, as well as how state-level incentives and market design impact VREs and these challenges. With each key challenge, we survey the literature to answer the question: To what extent is the problem, and how has it evolved over time? We first conduct a thorough review of ongoing challenges in electricity markets to understand the problem and review the empirical literature to capture important findings on how VREs, specifically, impact the problem. From this review, we highlight metrics that are important to understanding VRE integration and how market designs and outcomes are evolving with increasing levels of VREs. We propose several empirical models for future research to determine the impact of VREs on these identified challenges.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Managed Fast-Charging Model for Electric Vehicle Fleets with High Utilization and Multiple Charge-Acceptance Curves

A predictive control/scheduling optimization model is proposed for managed charging of an electric vehicle (EV) fleet - under time-of-use energy and demand prices, high vehicle utilization frequency (short dwell times), multiple charge- acceptance curves (configurable charging rates), and flexible vehicle demand. This context is particularly relevant for flight schools (small electric aircraft) or other commercial facilities where an EV fleet performs multiple operating and fast-charging sessions on the same day. The proposed model performs both the operational and charging scheduling of the vehicles, which is not typically done for residential managed charging and significantly increases problem complexity. The problem is formulated as a MILP model and a case study of a small fast-charging station is presented. Results demonstrate a significant reduction in operating cost, mainly from peak shaving during high demand price periods, achieved by coordinating the operation of different vehicles, chargers and charging rates.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

An Atlas of Current Customer-Facing Utility Program Designs and Pricing

The National Renewable Energy Laboratory (NREL) and Kevala conducted a targeted literature review and leveraged extensive expertise, including team members with four decades of experience in the utility sector, to characterize utility programs and rate designs. This analysis delves into the motivations behind these programs and the various hurdles they face. Through this in-depth study, the team provides critical insights into the operational dynamics of utility programs, identifying key drivers and barriers that influence their effectiveness and implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermoelectric heat pump water heater priced for mass market deployment with 30% energy savings

This project, a Cooperative Research and Development Agreement (CRADA) partnership between A. O. Smith and Oak Ridge National Laboratory (ORNL), was initiated to develop a heat pump water heater (HPWH) based on thermoelectric (TE) heat pump technology capable of seeing widespread market adoption by having a one-year payback versus electric resistance options.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi‐Decadal Decarbonization Pathways for U.S. Freight Rail

A‐STEP is a first‐of‐its‐kind, integrated, open‐source software tool aimed at guiding freight rail decarbonization decision‐making. It has tools for studying energy use details for individual trains, networks of trains, battery and hydrogen charging stations, national energy sourcing and pricing, and overall decarbonization costs and environmental impacts. It gives analysts an ability to study the challenges of making such change happen. Completely amenable to analyst specified inputs and parameter values, it can be customized to provide outputs for a wide variety of assumptions about future energy conditions and technological advances. Written in Python, C++, and VB.Net, A‐STEP can be implemented on both Windows and Linux‐based platforms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Jijak Gises Project

The Match-E-Be-Nash-She-Wish Band of Pottawatomi Indians, d.b.a. Gun Lake Tribe (Gun Lake Tribe/Tribe), installed a grid connected 68.87 kW solar photovoltaic array at the Tribe’s Jijak Property located in Hopkins, MI. The array generated 95,070 kWh its first year of operation, 7,014 kWh more than projected. The Jijak Gises solar array saved $\$$12,214 during the first year of production including $\$$6,022 in generation credit and $\$$6,192 in offset electrical cost. The array will save the Tribe more than $\$$312,000 with increasing electric rates during the normal life of the system reducing Gun Lake Tribe’s reliance on other energy resources. Competitive pricing allowed the Tribe to install a second smaller array to power the Jijak Garden. The 4.85kW Jijak Garden Array produced 6,643.96 kWh during its first year of production, 475.95 kwh more than projected saving $\$$1,126 during year one of production including invoice credits and offset energy consumption. Over the first 20 years of the array, it is expected to produce 132,879 kWh of electrical energy, saving over $26,000 over the life of the system.

14 SOLAR ENERGY↗

Impact of Glen Canyon Generation Loss

Colorado River Basin hydropower generation has faced challenges due to droughts and ecological and social water requirements. Specifically, Glen Canyon hydropower generation fluctuates substantially with recent extreme weather trends. Further, the western grid evolves with higher wind and solar share, and Glen Canyon hydropower's contribution to grid flexibility services is essential. The Western Area Power Administration (WAPA) markets and schedules electricity production at GCD, and the loss of this power could have significant financial consequences for the WAPA Colorado River Storage Project's (CRSP) Office because it may need to purchase relatively large amounts of energy to serve its firm electrical obligations. In addition, GCD provides grid reliability services for the WAPA Colorado-Missouri (WACM) balancing authority (BA). Both WAPA and DOE's Water & Power Technology Office (WPTO) are interested in researching how these drier hydrological conditions will impact federal electrical energy production, the Western Electricity Coordinating Council (WECC) power grid, and the value of hydropower in the face of lower production. We study multiple hydrologic and power grid scenarios to understand the grid impacts of the loss of Glen Canyon generation. The study uses a production cost model, water resources planning models, water-centric grid models, and various data analytic techniques. The study progress presentation discusses the selection of probable CRSP' hydropower scenarios and power grid scenarios to understand the impacts of Glen Canyon generation, which includes technologies that compensate the Glen Canyon energy and ancillary services contributions, transmission availability, and energy local marginal prices at interested grid locations of WAPA operation.

droughts↗

Solar and Wind Forecast Error Reserve Sharing in a Multi-Utility Region

As electricity systems transition to higher levels of solar and wind generation, electric system operators will likely need to hold additional reserves to manage the forecast error associated with these resources. Because wind and solar forecast errors tend to be poorly correlated across space, system operators can reduce their reserve requirements by sharing reserves. This paper examines the value of forecast error reserve sharing among balancing areas in the Southeast United States. It finds that forecast error reserve requirements increase linearly with growth in solar and wind generation capacity but that reserve sharing can significantly reduce physical (MW) reserve requirements (from 25%-26% to 18%-19% of average load in high solar scenarios). It finds that the value of forecast error reserve sharing declines with higher levels of solar and wind generation, due to lower wholesale energy and reserve prices. Even with declines in wholesale prices, forecast error reserve sharing can still provide substantial value (as much as $\$$400 million per year in a high solar scenario), though with higher levels of solar, wind, and electricity storage, this value is increasingly tied to avoiding scarcity prices. The results suggest the importance of coordinated capacity expansion planning for forecast error reserve sharing.

14 SOLAR ENERGY↗